1.The SMAD-Pathway Mediates HMGB1-Induced Proliferation and Metastatic Progression in Cutaneous Squamous Cell Carcinoma Cells
De-De LIAN ; Xue Mei LI ; Yu-Xi JIA ; Ming-Wei ZHOU ; Xiang-Ru CHEN ; Yang-Yang TIAN ; Min LI ; Ming-Hui SUN ; Ye ZHAO ; Hong-Jun LI ; Qing-Ling ZHANG
Annals of Dermatology 2026;38(1):51-58
Background:
High-mobility group box protein 1 (HMGB1) is a chromatin-binding protein involved in arthritis, ischemia, sepsis, atherosclerosis, neurodegenerative disorders, meningitis, and cancer. HMGB1 exhibits dual roles in cancer, acting as either a tumor suppressor or oncoprotein depending on context.
Objective:
This research aimed to elucidate HMGB1’s functional significance in cutaneous squamous cell carcinoma (cSCC).
Methods:
We overexpressed HMGB1 in cSCC cell lines using recombinant adenovirus and examined its effects on cell proliferation, colony formation, and cell migration.
Results:
Immunohistochemical analysis revealed elevated HMGB1 expression levels in cSCC tissue relative to normal epidermis. To assess the influence of HMGB1, we employed recombinant adenoviruses expressing HMGB1 to transduce SCC cell lines (SCC12 and SCC13). Enhanced HMGB1 expression significantly promoted cellular proliferation and colony formation capacity.Notably, HMGB1 overexpression elevated the levels of proliferation regulators, including P63, SOX2, CDK4 and CDK6. Furthermore, HMGB1 overexpression substantially enhanced tumor invasiveness, accompanied by upregulation of epithelial-mesenchymal transition (EMT) biomarkers. Mechanistically, overexpression of HMGB1 enhanced transforming growth factor-β signaling by increasing phosphorylation of SMAD2/3, the key mediators of EMT.
Conclusion
These data imply that HMGB1 acts as a tumor-promoting factor in cSCC.
2.Reactive and Enzyme-activated Probe Strategies for Imaging Acute Kidney Injury
Ru-Long CHEN ; Ting-Fei XIE ; Jin-Xin ZHANG ; Jia-Ting CHEN ; Jie LI ; Peng-Fei ZHANG ; Ji-Hong CHEN ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(6):1622-1637
Acute kidney injury (AKI) is a prevalent and life-threatening clinical syndrome characterised by a rapid decline in renal function and diverse pathological etiologies. The condition has been demonstrated to be associated with elevated mortality rates and an increased risk of progression to chronic kidney disease. At present, clinicians depend heavily on conventional functional markers, such as serum creatinine and urine output, for the diagnosis and staging of the disease. It is evident that these conventional indicators characteristically manifest a considerable temporal delay and only undergo modification subsequent to considerable tissue damage. This severely restricts the timeframe for early detection and timely therapeutic intervention. Furthermore, standard markers fail to provide specific biological information regarding the underlying cellular injury mechanisms. The utilisation of advanced probe technologies in molecular imaging offers a robust alternative to overcome these inherent diagnostic limitations.This comprehensive review systematically evaluates recent progress in the design and application of two primary categories of molecular imaging tools for acute kidney disease, specifically reactive probes and enzyme-activated probes. Reactive probes are engineered to specifically interact with redox-active chemical species, including hydrogen peroxide, peroxynitrite, hypochlorous acid, and sulfur dioxide. Because oxidative stress constitutes a primary early event in acute renal tubular damage, these probes enable researchers and clinicians to visualize early cellular injury and radical accumulation well before global renal functional decline becomes evident. We discuss the application of these reactive probes across multiple imaging modalities including fluorescence imaging, magnetic resonance imaging (MRI), positron emission tomography (PET), and photoacoustic techniques. Photoacoustic imaging combines high spatial resolution with deep tissue penetration and has successfully demonstrated the ability to provide diagnostic alerts up to 12 h before any detectable rise in serum creatinine levels. Additionally, specific reactive probes have shown promising translational potential when tested by high-throughput screening in clinical human urine samples. Enzyme-activated probes target the specific catalytic activity of disease-relevant enzymes. These include well-documented renal tubular structural biomarkers such as NAG, GGT, and ALP, along with apoptosis-related caspases and specific nitroreductases. By responding only to enzymatic cleavage, these tools provide highly specific and pathology-directed imaging readouts. Recent structural design strategies in this field have advanced significantly beyond single-enzyme detection. Researchers are now focusing on sophisticated dual-target recognition to minimize background noise, multimodal integration to cross-validate imaging signals, and theranostic applications where probes simultaneously deliver diagnostic feedback and therapeutic agents to injured tissues. Nanotechnology serves as a fundamental enabler for realizing these advanced probe functions. By precisely optimizing nanoparticle parameters such as hydrodynamic size, surface charge, and targeting ligands, researchers can achieve amplified signal output, highly precise kidney delivery, and protection against premature degradation in the systemic circulation. For example, modifying surface charges can significantly enhance the active uptake of nanoprobes by damaged renal tubular epithelial cells.While preclinical probe development has progressed rapidly, moving these technologies into routine clinical practice remains a major challenge. We analyze the translational feasibility and current obstacles from biological, technological, and regulatory perspectives. Although biological targets such as KIM-1, FAP, and ALP have been validated in extensive patient cohorts, practical barriers severely limit their immediate clinical application. These obstacles involve complex changes in in vivo pharmacokinetics. During an acute injury episode, the extreme drop in the glomerular filtration rate alters probe clearance and can cause unwanted systemic accumulation or confusing background imaging signals. Other major hurdles include a lack of comprehensive long-term toxicity data and the absence of standardized manufacturing protocols to ensure batch-to-batch consistency. Future successful translation will require rigorous multi-center clinical studies to confirm the true diagnostic value of these probes over traditional markers. Researchers must also establish strict standardization of imaging procedures and comprehensive safety evaluations. Ultimately, this review provides a thorough reference framework for designing clinically translatable molecular probes and building a precision diagnostic imaging system for acute kidney injury.
3.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
4.Endoplasmic reticulum stress and autophagy interaction in pathogenesis of postmenopausal osteoporosis
Ru-na CHEN ; Li-wei WEI ; Shuang CHAI ; Hong ZHANG ; Na QIN
Chinese Pharmacological Bulletin 2025;41(4):626-631
The endoplasmic reticulum is an important organelle responsible for the synthesis,folding and processing of proteins.When the endoplasmic reticulum protein folding ability is affect-ed,internal unfolded proteins or misfolded proteins accumulate in the endoplasmic reticulum accumulation,leading to endoplasmic reticulum structural dysfunction resulting in endoplasmic reticu-lum stress.Autophagy is the process by which cells selectively remove stress endoplasmic reticulum and error proteins.Under stress,the endoplasmic reticulum can maintain normal physiolog-ical functions through unfolded protein responses and autophagy.Postmenopausal osteoporosis is mainly due to an imbalance be-tween bone resorption by osteoclasts and bone formation by oste-oblasts.Endoplasmic reticulum stress and autophagy both modu-late bone cells status with consequences for bone homeostasis.This article provides a review of the progress of research on en-doplasmic reticulum stress and autophagy interaction in the path-ogenesis of postmenopausal osteoporosis.
5.Research on coagulation effect of cold atmospheric plasma jet device and its mechanism of action
Yan LI ; Hong-ye ZHENG ; Ao-xi XU ; Ya-jun ZHAO ; Shan-shan JIN ; Xu ZHANG ; Yu-fan WEI ; Yi-heng ZHANG ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(6):20-27
Objective To investigate the coagulation effect of a cold atmospheric plasma(CAP)jet device with helium as the working gas and to study its coagulation mechanism preliminarily.Methods A CAP jet device treatment group,a helium airflow treatment group,a hot air treatment group(60℃)and a natural coagulation group were formed according to the treatment modes of the blood samples,with 10 μL of blood samples involved in each group,in order to validate the coagulation effect of the CAP jet device in vitro;the coagulation mechanism of the CAP jet device was explored by its application to the treatment of anticoagulated whole blood,platelet-rich plasma and platelet-depleted plasma;the coagulation effect of the CAP jet device in vivo was verified with a mouse liver punctate hemorrhage model and a rabbit mesenteric hemorrhage model.Results The CAP jet device can significantly accelerate the coagulation of anticoagulated blood droplets,and the coagulation time of anticoagulated blood droplets in the CAP jet device-treated group was shortened from 28 min in the natural coagulation group to(23±1.56)s,with the difference statistically significant(P<0.05),and the CAP jet device treatment group gained advantages significantly over the helium airflow treatment group(P<0.05)and the hot air(60℃)treatment group(P<0.05)in coagulation-promoting effect;the procoagulant effect of the CAP jet device rose with the increase of platelet content in blood droplets,and the coagulation effect of platelet-rich blood droplets was significantly better than that of whole blood(P<0.05),while no coagulation was observed in platelet-poor droplets.The CAP jet device could rapidly stop hemostasis of punctate hemorrhage in mouse liver and mesenteric hemorrhage in rabbits without delayed hemorrhage occurring within 10 min,and no obvious structural abnormality of the liver and thermal damage of the tissue were found microscopically.Conclusion The CAP jet device plays procoagulant and hemostatic effects in vivo and in vitro,and its effect is not dependent on temperature and airflow evaporation effects and is considered to be related to platelet activation,with low thermal damage to living tissue.[Chinese Medical Equipment Journal,2025,46(6):20-27]
6.Research on coagulation effect of cold atmospheric plasma jet device and its mechanism of action
Yan LI ; Hong-ye ZHENG ; Ao-xi XU ; Ya-jun ZHAO ; Shan-shan JIN ; Xu ZHANG ; Yu-fan WEI ; Yi-heng ZHANG ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(6):20-27
Objective To investigate the coagulation effect of a cold atmospheric plasma(CAP)jet device with helium as the working gas and to study its coagulation mechanism preliminarily.Methods A CAP jet device treatment group,a helium airflow treatment group,a hot air treatment group(60℃)and a natural coagulation group were formed according to the treatment modes of the blood samples,with 10 μL of blood samples involved in each group,in order to validate the coagulation effect of the CAP jet device in vitro;the coagulation mechanism of the CAP jet device was explored by its application to the treatment of anticoagulated whole blood,platelet-rich plasma and platelet-depleted plasma;the coagulation effect of the CAP jet device in vivo was verified with a mouse liver punctate hemorrhage model and a rabbit mesenteric hemorrhage model.Results The CAP jet device can significantly accelerate the coagulation of anticoagulated blood droplets,and the coagulation time of anticoagulated blood droplets in the CAP jet device-treated group was shortened from 28 min in the natural coagulation group to(23±1.56)s,with the difference statistically significant(P<0.05),and the CAP jet device treatment group gained advantages significantly over the helium airflow treatment group(P<0.05)and the hot air(60℃)treatment group(P<0.05)in coagulation-promoting effect;the procoagulant effect of the CAP jet device rose with the increase of platelet content in blood droplets,and the coagulation effect of platelet-rich blood droplets was significantly better than that of whole blood(P<0.05),while no coagulation was observed in platelet-poor droplets.The CAP jet device could rapidly stop hemostasis of punctate hemorrhage in mouse liver and mesenteric hemorrhage in rabbits without delayed hemorrhage occurring within 10 min,and no obvious structural abnormality of the liver and thermal damage of the tissue were found microscopically.Conclusion The CAP jet device plays procoagulant and hemostatic effects in vivo and in vitro,and its effect is not dependent on temperature and airflow evaporation effects and is considered to be related to platelet activation,with low thermal damage to living tissue.[Chinese Medical Equipment Journal,2025,46(6):20-27]
7.Establishment of a rapid fluorescence immunochromatographic assay for avian influenza virus subtype H5N6
Hui LI ; Li LIU ; Yi-sheng ZHOU ; Zhi-hong ZHANG ; Qian-qian SI ; Ru-xia WANG ; Zhi-qiang DENG ; Yi-bing FAN ; Liang JIN ; Jie SUN ; Chun-hua YANG
Chinese Journal of Zoonoses 2025;41(3):243-248,283
In view of the characteristics of H5N6 subtype avian influenza virus(AIV)that it has both high pathogenicity and the risk of cross-species transmission,posing a serious threat to the poultry farming industry and public health security,in order to effectively prevent and control the spread of H5N6 avian influenza,a rapid,sensitive and specific detection technolo-gy was established in this study.The specific monoclonal antibodies against the neuraminidase N6 protein of avian influenza A virus subtype H5N6 were obtained through hybridoma and monoclonal antibody technology.These antibodies were coupled and labeled with carboxyl-functionalized fluorescent quantum dots,along with previously prepared specific antibodies against the hemagglutinin H5 protein.A rapid fluorescence immunochromatographic detection method for the H5N6 subtype of avian influ-enza virus was established according to the principle of double-antibody sandwich immunochromatography.This method a-chieved a detection sensitivity of 1 ng/mL for recombinant hemagglutinin H5 subtype protein and 0.1 ng/mL for recombinant neuraminidase N6 subtype protein.Moreover,the method exhibited no cross-reactivity with other influenza subtypes or patho-gens,such as Newcastle disease(ND),infectious bronchitis(IB),and infectious laryngotracheitis(ILT),thus demonstrating good specificity.The method effectively identified the highly pathogenic avian influenza virus H5 subtype and directly distin-guished the H5N6 subtype with good accuracy.The fluorescent quantum dot immunochromatographic typing detection method established herein met the sensitivity,specificity,and accuracy requirements for H5N6 subtype detection,and can be further used for rapid detection of the H5 and H5N6 subtypes of avian influenza virus.
8.Association between insulin resistance and idiopathic central precocious puberty in girls and the diagnostic value of insulin resistance
Jin-Bo LI ; Ya XIAO ; Shu-Qin JIANG ; Xiang-Yang LUO ; Hong-Ru ZHANG ; Jun SUN ; Wen-Hui SHI ; Ying YANG ; Wei WANG
Chinese Journal of Contemporary Pediatrics 2025;27(12):1487-1492
Objective To explore the relationship between insulin resistance and idiopathic central precocious puberty(ICPP)in girls and the diagnostic value of insulin resistance.Methods Clinical data of 245 girls aged 4 to 7.5 years with low luteinizing hormone(LH)levels(0.2-0.83 IU/L),normal body weight(body mass index standard deviation score between-2 and+2),and early breast development who visited the Department of Pediatric Endocrinology,Henan Provincial Maternal and Child Health Hospital from January 2022 to March 2025 were retrospectively analyzed.According to the Expert Consensus on the Diagnosis and Treatment of Central Precocious Puberty(2022),patients were assigned to an ICPP group(n=123)or a control group(n=122).Correlations between the homeostasis model assessment of insulin resistance(HOMA-IR)and selected indices were assessed.Multivariable logistic regression was used to evaluate the association between HOMA-IR and ICPP,and the diagnostic performance of various indices for ICPP was evaluated.Results HOMA-IR was higher in the ICPP group than in the control group(P<0.001)and was positively correlated with LH peak(rs=0.467,P<0.05)and the LH peak/FSH peak ratio(rs=0.444,P<0.05).The multivariable logistic regression model including age,BMI,and basal LH showed that HOMA-IR was closely associated with ICPP(OR=2.756,95%CI:1.940-3.913).Receiver operating characteristic curve analysis showed that the areas under the curve for basal LH,HOMA-IR,and their combination in diagnosing ICPP were 0.735,0.735,and 0.805,respectively(P<0.05),and the combined model had a greater area under the curve than either basal LH or HOMA-IR alone(both P<0.05).Conclusions HOMA-IR is closely associated with ICPP in girls with low LH and normal body weight,and combining HOMA-IR with basal LH improves early identification and diagnostic efficiency in this population.
9.Study of debridement effects of multi shapes of plasma scalpels in explosion injury model
Hong-ye ZHENG ; Yu LI ; Zi-heng XU ; Yu-fan WEI ; Bo-ya ZHANG ; Yan LI ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(2):31-38
Objective To explore the debridement effects of 3 types of plasma scalpels for the animal model of explosion injury,and to compare them with the steel scalpel and high-frequency electrosurgical scalpel.Methods Firstly,blast wounds were constructed in the right inguinal regions of 9 Landrace pigs by high-pressure gas impact combined with preset metal shrapnel.Secondly,debridement was carried out in experimental groups with wide-,arrow-or needle-type plasma scalpel and in control groups with steel and high-frequency electrisurgical scalpel,with the operating temperature and debridement time recorded during the procedure and trauma specimens analyzed pathologically after the debridement;comparisons were performed among the five types of scalpels in terms of debridement effect,and among the four ones in terms of maximum operating temperature and depth of tissue thermal damage under electrocutaneous cutting and electrocoagulation modes with the steel scalpel excluded because it did not generate any heat.GraphPad Prism 9.5.1 software was used for statistical analysis.Results There were no significant differences in debridement effect found between the three plasma scalpels and the steel and high-frequency electrosurgical scalpels(P>0.05).The three types of plasma scalpels had the maximum operating temperature lower significantly than that of the high-frequency electrosurgical scalpel during debridement(P<0.05).Under electrosection and electrocoagulation modes the three plasma scalpels had the depths of tissue thermal damage statistically less than that by the high-frequency electrosurgical scalpel under electrosection and electrocoagulation modes(P<0.05).The depths of tissue thermal damage by the four scalpels under electrocoagulation mode were obviously greater than those under electrosection mode(P<0.05).Conclusion Multi shapes of plasma scalpels behave well in debridement with low operating temperature,little tissue thermal damage and high efficiency for wound protection and the same efficacy with the steel scalpel and high-frequency electrosur-gical scalpel.[Chinese Medical Equipment Journal,2025,46(2):31-38]
10.Association between insulin resistance and idiopathic central precocious puberty in girls and the diagnostic value of insulin resistance
Jin-Bo LI ; Ya XIAO ; Shu-Qin JIANG ; Xiang-Yang LUO ; Hong-Ru ZHANG ; Jun SUN ; Wen-Hui SHI ; Ying YANG ; Wei WANG
Chinese Journal of Contemporary Pediatrics 2025;27(12):1487-1492
Objective To explore the relationship between insulin resistance and idiopathic central precocious puberty(ICPP)in girls and the diagnostic value of insulin resistance.Methods Clinical data of 245 girls aged 4 to 7.5 years with low luteinizing hormone(LH)levels(0.2-0.83 IU/L),normal body weight(body mass index standard deviation score between-2 and+2),and early breast development who visited the Department of Pediatric Endocrinology,Henan Provincial Maternal and Child Health Hospital from January 2022 to March 2025 were retrospectively analyzed.According to the Expert Consensus on the Diagnosis and Treatment of Central Precocious Puberty(2022),patients were assigned to an ICPP group(n=123)or a control group(n=122).Correlations between the homeostasis model assessment of insulin resistance(HOMA-IR)and selected indices were assessed.Multivariable logistic regression was used to evaluate the association between HOMA-IR and ICPP,and the diagnostic performance of various indices for ICPP was evaluated.Results HOMA-IR was higher in the ICPP group than in the control group(P<0.001)and was positively correlated with LH peak(rs=0.467,P<0.05)and the LH peak/FSH peak ratio(rs=0.444,P<0.05).The multivariable logistic regression model including age,BMI,and basal LH showed that HOMA-IR was closely associated with ICPP(OR=2.756,95%CI:1.940-3.913).Receiver operating characteristic curve analysis showed that the areas under the curve for basal LH,HOMA-IR,and their combination in diagnosing ICPP were 0.735,0.735,and 0.805,respectively(P<0.05),and the combined model had a greater area under the curve than either basal LH or HOMA-IR alone(both P<0.05).Conclusions HOMA-IR is closely associated with ICPP in girls with low LH and normal body weight,and combining HOMA-IR with basal LH improves early identification and diagnostic efficiency in this population.


Result Analysis
Print
Save
E-mail