1.Biomechanical mechanism of sports-related patellar tendinitis
Caihong ZHONG ; Xiaoge XIAO ; Ming LI ; Jianhong LIN ; Jing HONG
Chinese Journal of Tissue Engineering Research 2026;30(6):1417-1423
BACKGROUND:Patellar tendonitis can present as tendon degeneration that fails to heal due to tissue overload and incomplete recovery.Patellar tendonitis is a predisposition to high jumping and its pathogenesis has not been clearly defined.OBJECTIVE:To explore the stress-strain relationship of patellar tendon in the take-off technique of high jump through the finite element model with accurate human anatomical structure,so as to provide ideas for the prevention and rehabilitation of patellar tendinitis.METHODS:Based on the CT and MRI imaging data of the lower extremity(including the knee and ankle)of one subject(22 years old,183 cm height,70 kg body mass),a three-dimensional finite element model of the lower extremity was reconstructed using medical imaging software,reverse engineering software and modeling software.The plantar pressure of the take-off leg was collected in eight subjects by gait testing system,and the technical action of high jump take-off was collected by motion capture system.The captured data were imported into human sports biomechanics software for analysis,and kinematic and kinetic data were obtained as the boundary conditions of finite element model for finite element simulation analysis.RESULTS AND CONCLUSION:The force borne by the patellar tendon reached 3.29 times of its own body mass when the subjects took off.In the take-off stage,the peak values of normal equivalent stress,strain and shear stress of the patellar tendon were 127.76 MPa,0.81 and 37.69 MPa,respectively,which were in the nonlinear region of the stress-strain curve,and the peak values were distributed in the proximal and posterior parts of patellar tendon.To conclude,the high patellar tendon force,strain and shear stress caused by the load of 3.29 times its own body mass during take-off are related to the induction of patellar tendinitis.
2.Strategic Optimization of CHO Cell Expression Platforms for Biopharmaceutical Manufacturing
Rui-Ming ZHANG ; Meng-Lin LI ; Hong-Wei ZHU ; Xing-Xiao ZHANG
Progress in Biochemistry and Biophysics 2026;53(2):327-341
Chinese hamster ovary (CHO) cells are the most established and versatile mammalian expression system for the large-scale production of recombinant therapeutic proteins, owing to their genetic stability, adaptability to serum-free suspension culture, and ability to perform human-like post-translational modifications. More than 70% of biologics approved by the U.S. Food and Drug Administration rely on CHO-based production platforms, underscoring their central role in modern biopharmaceutical manufacturing. Despite these advantages, CHO systems continue to face three persistent bottlenecks that limit their potential for high-yield, reproducible, and cost-efficient production: excessive metabolic burden during high-density culture, heterogeneity of glycosylation patterns, and progressive loss of long-term expression stability. This review provides an integrated analysis of recent advances addressing these challenges and proposes a forward-looking framework for constructing intelligent and sustainable CHO cell factories. In terms of metabolic regulation, excessive lactate and ammonia accumulation disrupts energy balance and reduces recombinant protein synthesis efficiency. Optimization of culture parameters such as temperature, pH, dissolved oxygen, osmolarity, and glucose feeding can effectively alleviate metabolic stress, while supplementation with modulators including sodium butyrate, baicalein, and S-adenosylmethionine promotes specific productivity (qP) by modulating apoptosis and chromatin structure. Furthermore, genetic engineering strategies—such as overexpression of MPC1/2, HSP27, and SIRT6 or knockout of Bax, Apaf1, and IGF-1R—have demonstrated significant improvements in cell viability and product yield. The combination of multi-omics metabolic modeling with artificial intelligence (AI)-based prediction offers new opportunities for building self-regulating CHO systems capable of dynamic adaptation to environmental stress. Regarding glycosylation uniformity, which determines therapeutic efficacy and immunogenicity, gene editing-based glycoengineering (e.g., FUT8 knockdown or ST6Gal1 overexpression) has enabled the humanization of CHO glycan profiles, minimizing non-human sugar residues and enhancing drug stability. Process-level strategies such as galactose or manganese co-feeding and fine control of temperature or osmolarity further allow rational regulation of glycosyltransferase activity. Additionally, in vitro chemoenzymatic remodeling provides a complementary route to construct human-type glycans with defined structures, though industrial applications remain constrained by cost and scalability. The integration of model-driven process design and AI feedback control is expected to enable real-time prediction and correction of glycosylation deviations, ensuring batch-to-batch consistency in continuous biomanufacturing. Long-term expression stability, another critical challenge, is often impaired by promoter silencing, chromatin condensation, and random genomic integration. Molecular optimization—such as the use of improved promoters (CMV, EF-1α, or CHO endogenous promoters), Kozak and signal peptide refinement, and incorporation of chromatin-opening elements (UCOE, MAR, STAR)—helps maintain durable transcriptional activity, while site-specific integration systems including Cre/loxP, Flp/FRT, φC31, and CRISPR/Cas9 can enable single-copy, position-independent gene insertion at genomic safe-harbor loci, ensuring stable, predictable expression. Collectively, this review highlights a paradigm shift in CHO system optimization driven by the convergence of genome editing, synthetic biology, and artificial intelligence. The transition from empirical optimization to rational, data-driven design will facilitate the development of programmable CHO platforms capable of autonomous regulation of metabolic flux, glycosylation fidelity, and transcriptional activity. Such intelligent cell factories are expected to accelerate the transformation from laboratory-scale research to industrial-scale, high-consistency, and economically sustainable biopharmaceutical manufacturing, thereby supporting the next generation of efficient and customizable biologics manufacturing.
3.Strategic Optimization of CHO Cell Expression Platforms for Biopharmaceutical Manufacturing
Rui-Ming ZHANG ; Meng-Lin LI ; Hong-Wei ZHU ; Xing-Xiao ZHANG
Progress in Biochemistry and Biophysics 2026;53(2):327-341
Chinese hamster ovary (CHO) cells are the most established and versatile mammalian expression system for the large-scale production of recombinant therapeutic proteins, owing to their genetic stability, adaptability to serum-free suspension culture, and ability to perform human-like post-translational modifications. More than 70% of biologics approved by the U.S. Food and Drug Administration rely on CHO-based production platforms, underscoring their central role in modern biopharmaceutical manufacturing. Despite these advantages, CHO systems continue to face three persistent bottlenecks that limit their potential for high-yield, reproducible, and cost-efficient production: excessive metabolic burden during high-density culture, heterogeneity of glycosylation patterns, and progressive loss of long-term expression stability. This review provides an integrated analysis of recent advances addressing these challenges and proposes a forward-looking framework for constructing intelligent and sustainable CHO cell factories. In terms of metabolic regulation, excessive lactate and ammonia accumulation disrupts energy balance and reduces recombinant protein synthesis efficiency. Optimization of culture parameters such as temperature, pH, dissolved oxygen, osmolarity, and glucose feeding can effectively alleviate metabolic stress, while supplementation with modulators including sodium butyrate, baicalein, and S-adenosylmethionine promotes specific productivity (qP) by modulating apoptosis and chromatin structure. Furthermore, genetic engineering strategies—such as overexpression of MPC1/2, HSP27, and SIRT6 or knockout of Bax, Apaf1, and IGF-1R—have demonstrated significant improvements in cell viability and product yield. The combination of multi-omics metabolic modeling with artificial intelligence (AI)-based prediction offers new opportunities for building self-regulating CHO systems capable of dynamic adaptation to environmental stress. Regarding glycosylation uniformity, which determines therapeutic efficacy and immunogenicity, gene editing-based glycoengineering (e.g., FUT8 knockdown or ST6Gal1 overexpression) has enabled the humanization of CHO glycan profiles, minimizing non-human sugar residues and enhancing drug stability. Process-level strategies such as galactose or manganese co-feeding and fine control of temperature or osmolarity further allow rational regulation of glycosyltransferase activity. Additionally, in vitro chemoenzymatic remodeling provides a complementary route to construct human-type glycans with defined structures, though industrial applications remain constrained by cost and scalability. The integration of model-driven process design and AI feedback control is expected to enable real-time prediction and correction of glycosylation deviations, ensuring batch-to-batch consistency in continuous biomanufacturing. Long-term expression stability, another critical challenge, is often impaired by promoter silencing, chromatin condensation, and random genomic integration. Molecular optimization—such as the use of improved promoters (CMV, EF-1α, or CHO endogenous promoters), Kozak and signal peptide refinement, and incorporation of chromatin-opening elements (UCOE, MAR, STAR)—helps maintain durable transcriptional activity, while site-specific integration systems including Cre/loxP, Flp/FRT, φC31, and CRISPR/Cas9 can enable single-copy, position-independent gene insertion at genomic safe-harbor loci, ensuring stable, predictable expression. Collectively, this review highlights a paradigm shift in CHO system optimization driven by the convergence of genome editing, synthetic biology, and artificial intelligence. The transition from empirical optimization to rational, data-driven design will facilitate the development of programmable CHO platforms capable of autonomous regulation of metabolic flux, glycosylation fidelity, and transcriptional activity. Such intelligent cell factories are expected to accelerate the transformation from laboratory-scale research to industrial-scale, high-consistency, and economically sustainable biopharmaceutical manufacturing, thereby supporting the next generation of efficient and customizable biologics manufacturing.
4.Biomechanical mechanism of sports-related patellar tendinitis
Caihong ZHONG ; Xiaoge XIAO ; Ming LI ; Jianhong LIN ; Jing HONG
Chinese Journal of Tissue Engineering Research 2026;30(6):1417-1423
BACKGROUND:Patellar tendonitis can present as tendon degeneration that fails to heal due to tissue overload and incomplete recovery.Patellar tendonitis is a predisposition to high jumping and its pathogenesis has not been clearly defined.OBJECTIVE:To explore the stress-strain relationship of patellar tendon in the take-off technique of high jump through the finite element model with accurate human anatomical structure,so as to provide ideas for the prevention and rehabilitation of patellar tendinitis.METHODS:Based on the CT and MRI imaging data of the lower extremity(including the knee and ankle)of one subject(22 years old,183 cm height,70 kg body mass),a three-dimensional finite element model of the lower extremity was reconstructed using medical imaging software,reverse engineering software and modeling software.The plantar pressure of the take-off leg was collected in eight subjects by gait testing system,and the technical action of high jump take-off was collected by motion capture system.The captured data were imported into human sports biomechanics software for analysis,and kinematic and kinetic data were obtained as the boundary conditions of finite element model for finite element simulation analysis.RESULTS AND CONCLUSION:The force borne by the patellar tendon reached 3.29 times of its own body mass when the subjects took off.In the take-off stage,the peak values of normal equivalent stress,strain and shear stress of the patellar tendon were 127.76 MPa,0.81 and 37.69 MPa,respectively,which were in the nonlinear region of the stress-strain curve,and the peak values were distributed in the proximal and posterior parts of patellar tendon.To conclude,the high patellar tendon force,strain and shear stress caused by the load of 3.29 times its own body mass during take-off are related to the induction of patellar tendinitis.
5.The SMAD-Pathway Mediates HMGB1-Induced Proliferation and Metastatic Progression in Cutaneous Squamous Cell Carcinoma Cells
De-De LIAN ; Xue Mei LI ; Yu-Xi JIA ; Ming-Wei ZHOU ; Xiang-Ru CHEN ; Yang-Yang TIAN ; Min LI ; Ming-Hui SUN ; Ye ZHAO ; Hong-Jun LI ; Qing-Ling ZHANG
Annals of Dermatology 2026;38(1):51-58
Background:
High-mobility group box protein 1 (HMGB1) is a chromatin-binding protein involved in arthritis, ischemia, sepsis, atherosclerosis, neurodegenerative disorders, meningitis, and cancer. HMGB1 exhibits dual roles in cancer, acting as either a tumor suppressor or oncoprotein depending on context.
Objective:
This research aimed to elucidate HMGB1’s functional significance in cutaneous squamous cell carcinoma (cSCC).
Methods:
We overexpressed HMGB1 in cSCC cell lines using recombinant adenovirus and examined its effects on cell proliferation, colony formation, and cell migration.
Results:
Immunohistochemical analysis revealed elevated HMGB1 expression levels in cSCC tissue relative to normal epidermis. To assess the influence of HMGB1, we employed recombinant adenoviruses expressing HMGB1 to transduce SCC cell lines (SCC12 and SCC13). Enhanced HMGB1 expression significantly promoted cellular proliferation and colony formation capacity.Notably, HMGB1 overexpression elevated the levels of proliferation regulators, including P63, SOX2, CDK4 and CDK6. Furthermore, HMGB1 overexpression substantially enhanced tumor invasiveness, accompanied by upregulation of epithelial-mesenchymal transition (EMT) biomarkers. Mechanistically, overexpression of HMGB1 enhanced transforming growth factor-β signaling by increasing phosphorylation of SMAD2/3, the key mediators of EMT.
Conclusion
These data imply that HMGB1 acts as a tumor-promoting factor in cSCC.
6.Orthopedic manipulation combined with percutaneous reduction and Kirschner wire internal fixation for Sanders typeⅡand Ⅲ calcaneal fractures.
Feng DAI ; Jin-Tao LIU ; Zhi-Gang ZHANG ; Xue-Qiang SHEN ; Li-Ming WU ; Peng-Fei YU ; Hong JIANG
China Journal of Orthopaedics and Traumatology 2025;38(3):306-310
OBJECTIVE:
To explore clinical effects of bone setting manipulation combined with pry reduction and Kirschner needle internal fixation in treating SandersⅡ-Ⅲ calcaneal fracture.
METHODS:
Clinical data of 52 patients with types Sanders Ⅱand Ⅲ calcaneal fracture (foot) treated with bone-setting manipulation combined with pry reduction and Kirscher needle internal fixation from July 2017 to July 2019 were retrospectively analyzed, including 43 males and 9 females, aged from 31 to 72 years old with an average of (50.83±10.48) years old; 15 patients with Sanders typeⅡ and 37 patients with Sanders type Ⅲ. The changes of Bühler angle, Gissane angle, calcaneus width and calcaneus height before operation and 24 months after operation were compared, and Maryland foot function score was performed to evaluate clinical effects.
RESULTS:
All patients were followed up from 24 to 60 months with an average of (41.50±9.86)months. The fracture healed normally and the healing time was (11.00±0.95) weeks. Bühler angle, Gissane angle, calcaneal bone width and calcaneal bone height were increased from (16.37±8.36)°, (96.27±9.62)°, (46.82±4.67) mm, (38.41±3.58) mm before operation to (31.48±8.24)°, (111.62±8.69)°, (42.06±4.83) mm, (44.21±3.82) mm at 24 months after operation, and the difference were statistically significant (P<0.01). Postoperative Maryland score at 24 months was (93.04±8.83), 40 patients got excellent result, 7 good and 5 fair.
CONCLUSION
Orthopedic manipulation combined with percutaneous reduction and Kirschner wire internal fixation could significantly improve Bühler angle, Gissane angle, width, and height of Sanders typeⅡ and Ⅲ calcaneal fractures, and the curative effect is satisfactory.
Humans
;
Male
;
Female
;
Calcaneus/surgery*
;
Middle Aged
;
Fracture Fixation, Internal/methods*
;
Adult
;
Aged
;
Fractures, Bone/therapy*
;
Retrospective Studies
;
Bone Wires
;
Manipulation, Orthopedic/methods*
7.Single-position O-arm X-ray navigation assisted oblique lateral interbody fusion combined with minimally invasive percutaneous pedicle nail internal fixation for lumbar spondylolisthesis.
Kai-Kai TU ; Hui FEI ; Yu-Liang LOU ; Can-Feng WANG ; Chang-Ming LI ; Li-Shen ZHOU ; Feng HONG
China Journal of Orthopaedics and Traumatology 2025;38(5):447-453
OBJECTIVE:
To investigate the early clinical efficacy of single-position O-arm navigation-assisted oblique lateral interbody fusion(OLIF) combined with minimally invasive percutaneous pedicle screw fixation(PPS) in the treatment of lumbar spondylolisthesis.
METHODS:
A retrospective analysis was conducted on 22 patients with lumbar spondylolisthesis who underwent OLIF-PPS surgery including 11 males and 11 females with a mean age of (64.6±1.5) years old ranging from 49 to 80 years old between April 2021 and June 2023. All patients presented with lumbosacral pain, lower limb radiating pain, numbness, and had poor responses to conservative treatment. Surgical time, intraoperative blood loss, hospital stay, and postoperative complications were recorded. Clinical outcomes were evaluated using the visual analogue scale(VAS) and Oswestry disability index(ODI) preoperatively at 3 days after operation and the final follow-up. Standing lumbar anteroposterior and lateral X-rays were performed to measure disc height(DH), slippage degree, vertebral reduction rate, pedicle screw accuracy, and cage subsidence.
RESULTS:
All surgeries were successfully completed with a mean follow-up of (27.1±2.2) months (range 18 to 36 months). The mean surgical time was (76.1±12.2) min (range 60 to 93 min), intraoperative blood loss was (86.3±32.2) ml (range 40 to 113 ml), and hospital stay was (7.1±1.2) days. Postoperative VAS significantly improved from (7.2±0.7) preoperatively to (2.3±0.5) at 3 days after operation and (1.7±0.2) at the final follow-up (P<0.05). ODI decreased from (68.5±7.2)% preoperatively to (30.3±3.1)% at 3 days after operation and (16.6±1.6)% at the final follow-up (P<0.05). DH increased from (8.5±1.7) mm preoperatively to (18.1±1.4) mm at 3 days after operation and (17.2±1.1) mm at the final follow-up (P<0.05). Slippage degree improved from (24.1±4.6)% preoperatively to (10.3±4.2)% at 3 days after operation and (10.1±3.2)% at the final follow-up (P<0.05). A total of 88 pedicle screws were implanted with an excellent rate of 98% (86/88). Complications included transient left hip flexion weakness (2 cases) and left anteromedial thigh pain (1 case), all resolved during follow-up. No incision hematoma, infection, screw loosening, or cage subsidence occurred.
CONCLUSION
Single-position O-arm navigation-assisted OLIF combined with PPS demonstrates satisfactory early clinical efficacy for lumbar spondylolisthesis, with advantages including minimal invasiveness, significant pain relief, effective vertebral reduction, and low complication rates.
Humans
;
Male
;
Female
;
Spondylolisthesis/diagnostic imaging*
;
Middle Aged
;
Aged
;
Spinal Fusion/methods*
;
Lumbar Vertebrae/diagnostic imaging*
;
Minimally Invasive Surgical Procedures/methods*
;
Pedicle Screws
;
Aged, 80 and over
;
Retrospective Studies
8.Effect of lumbar manipulation for lumbar disc herniation at different protrusion locations based on Michigan State University grading.
Shuai PEI ; Jie YU ; Ming-Hui ZHUANG ; Hong JIANG ; Yu-Wei LI
China Journal of Orthopaedics and Traumatology 2025;38(8):786-791
OBJECTIVE:
To study the efficacy of lumbar oblique manipulation in the treatment of lumbar disc herniation with different herniation locations based on MSU classification.
METHODS:
A total of 272 patients with lumbar disc herniation who were treated from June 2023 to December 2023 were divided into central type group, paracentral type group, and far lateral type group. Among them, there were 73 cases in the central type group, including 41 males and 32 females, with an age of (46.39±6.89) years;161 cases in the paracentral type group, including 88 males and 73 females, with an age of (37.14±5.89) years;and 38 cases in the far lateral type group, including 22 males and 16 females, with an age of (28.56±4.89) years. The visual analogue scale (VAS) and straight leg raising angle of the three groups of patients before treatment, after treatment, and at 1 and 3 months after treatment were recorded, and inter-group, intra-group, and correlation comparisons were made.
RESULTS:
A total of 272 patients were followed up, with a follow-up time of (3.0±0.2) months. The VAS score of central type patients after treatment was 2(2, 3) points, which was lower than 4(3, 5) points before treatment, and the difference was statistically significant (P<0.05). There was no statistically significant difference between 1 month and 3 months after treatment and before treatment (P>0.05). The VAS score of paracentral type patients after treatment 2(2, 3) points and 1 month after treatment 3(2, 4) points were lower than that before treatment 5(4, 6) points, and the differences were statistically significant (P<0.05). There was no statistically significant difference in VAS between 3 months after treatment and before treatment (P>0.05). There were no statistically significant differences in VAS scores of far lateral type patients before treatment, after treatment, and at 1 and 3 months after treatment (P>0.05). The straight leg raising angle of central type patients after treatment 64(58, 69) and 1 month after treatment 58(52, 65) were significantly different from that before treatment 44(40, 51) (P<0.05);there was no statistically significant difference between 3 months after treatment and before treatment (P>0.05). The straight leg raising angle of paracentral type patients after treatment 61(55, 67)°, 1 month after treatment 61(53, 66)°, and 3 months after treatment 47(41, 56)° were significantly different from that before treatment 44(36, 52)° (P<0.05). There were no statistically significant differences in the straight leg raising angle of far lateral type patients before treatment, after treatment, and at 1 and 3 months after treatment (P>0.05). There was a correlation between VAS and straight leg raising angle in the three groups of patients, but there was no linear relationship.
CONCLUSION
Lumbar oblique manipulation has a better effect in treating patients with central and paracentral lumbar disc herniation, but a poor effect in treating far lateral type;after treatment, the curative effect of paracentral type patients lasts longer than that of central type patients.
Humans
;
Male
;
Female
;
Intervertebral Disc Displacement/physiopathology*
;
Adult
;
Lumbar Vertebrae/physiopathology*
;
Middle Aged
;
Manipulation, Spinal
9.Comparison of application and efficacy of domestic HURWA and imported Smith & Nephew Cori robots in total knee arthroplasty.
Ming-You WANG ; Zhuo-Dong TANG ; Yu-Ping LAN ; Heng XIAO ; Ming-Li WANG ; Xun-Zhou SONG ; Hong-Ping WANG
China Journal of Orthopaedics and Traumatology 2025;38(10):1027-1036
OBJECTIVE:
Investigation on the clinical application of HURWA robot and Smith & Nephew Cori robot in total knee arthroplasty(TKA).
METHODS:
A retrospective analysis was performed on 84 patients with knee osteoarthritis who underwent robotic-assisted TKA (RATKA) between June 2023 and March 2025. According to the different robotic systems used, the patients were divided into the domestic HUARUN robotic-assisted total knee arthroplasty group (HRATKA group) and the Smith & Nephew Cori robotic-assisted total knee arthroplasty group (CRATKA group). There were 42 patients in the HRATKA group, including 16 males and 26 females; the age ranged from 56 to 73 years old, with an average of (64.70±8.30) years old;the body mass index (BMI) was (25.10±2.30) kg·m-2;21 cases were on the right side and 21 cases on the left side;in terms of Kellgren-Lawrence(K-L) classification, there were 15 cases of Grade Ⅲ and 27 cases of Grade Ⅳ;the disease duration ranged from 3 to 25 years, with an average of (15.5±7.5) years. The CRATKA group also included 42 patients, with 14 males and 28 females;the age ranged from 58 to 74 years old, with an average of (65.60±7.50) years old;the BMI was (24.50±2.70) kg·m-2; 20 cases were on the right side and 22 cases on the left side;regarding K-L classification, there were 11 cases of Grade Ⅲ and 31 cases of Grade Ⅳ;the disease duration ranged from 2 to 26 years, with an average of (16.5±8.8) years. Collect general data of all patients, including age, gender, height, weight, surgical site, K-L classification, incision length, and operation time. To evaluate prosthesis position, compare the frontal tibia component (FTC) angle, lateral femoral component (LFC) angle, lateral tibia component (LTC) angle, and frontal femoral component angle between the two groups of patients after surgery. Measure the deviation of the hip-knee-ankle (HKA) angle to assess lower limb alignment. Additionally, compare the following indicators between the two groups:Knee Society Score (KSS), Visual Analogue Scale (VAS) for pain, knee range of motion (ROM), hemoglobin (HB) level, hematocrit (HCT) level, complication rate, and in-hospital satisfaction.
RESULTS:
All patients successfully completed the surgery as scheduled, and all were followed up after the operation. The follow-up period ranged from 5 to 17 months with an average of (11.2±6.1) months. There were 4 cases of venous thrombosis in the HRATKA group and 3 cases in the CRATKA group;each group had 2 cases of wound exudation. No mechanical-related complications, pulmonary embolism, or other severe complications occurred. Comparison of the incision length and hospital stay between the HRATKA group and the CRATKA group showed no statistically significant difference (P>0.05). The operation time in the HRATKA group was (96.80±7.10) minutes, which was longer than that in the CRATKA group (90.10±8.80) minutes, and the difference was statistically significant (P<0.05). In the HRATKA group, the HKA angle was (178.93±1.11) degree, the FFC angle was (89.00±0.91)°, and the LFC angle was (7.31±2.17) degree;the corresponding values in the CRATKA group were (178.05±1.34)°, (87.88±1.74)°, and (10.60±2.84) degree respectively. The differences in these three indicators between the two groups were all statistically significant (P<0.05). However, there were no statistically significant differences in the FTC angle or LTC angle between the two groups (P>0.05). There was also no statistically significant difference in the total perioperative blood loss between the two groups (P>0.05). At 3 days after surgery, the VAS score for movement in the HRATKA group (5.95±1.45) points was higher than that in the CRATKA group (4.50±0.97) points, with a statistically significant difference (P<0.05);at 90 days after surgery, there was no statistically significant difference in the movement VAS score between the two groups (P>0.05). Additionally, no statistically significant differences were observed between the two groups in the KSS, ROM at 3 and 90 days after surgery, or satisfaction degree during hospitalization (all P>0.05).
CONCLUSION
The domestic HURWA robot demonstrates excellent performance in osteotomy efficiency and lower limb alignment recovery. The Smith & Nephew Cori robot has a significant advantage in soft tissue assessment and joint stability optimization. Both robotic systems offer high-quality surgical treatments that significantly improve short-term knee function.
Humans
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Aged
;
Middle Aged
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Osteoarthritis, Knee/surgery*
10.Preliminary efficacy observation of 3D printed functional spinal external fixation brace combined with McKenzie therapy in the treatment of lumbar disc herniation.
Ning-Xia WANG ; Ping CHEN ; Hai-Dong WANG ; Jing JI ; Fang-Hong NIAN ; Xin LIU ; Chong-Fei JIN ; Duo-Ming ZHAO ; Hao-Lin LI ; Wei-Gang CHENG ; Gui-Lin LAI ; Guo-Biao WU
China Journal of Orthopaedics and Traumatology 2025;38(10):1047-1054
OBJECTIVE:
To observe the clinical efficacy of 3D printing spinal external fixator combined with McKenzie therapy for patients with lumbar dics herniation (LDH).
METHODS:
Sixty patients with LDH between January 2022 and January 2023 were enrolled. Among them, 30 patients were given McKinsey training. According to different treatment methods, all patients were divided into McKenzie group and McKenzie + 3D printing group, 30 patients in each group. The McKenzie group provided McKenzie therapy. The McKenzie + 3D printing group were treated with 3D printing spinal external fixation brace on the basis of McKenzie therapy. Patients in both groups were between 25 and 60 years of age and had their first illness. In the McKenzie group, there were 19 males and 11 females, with an average age of (48.57±5.86) years old, and the disease duration was (7.03 ±2.39) months. The McKenzie + 3D printing group, there were 21 males and 9 females, with an average age of (48.80±5.92) years old, and the disease duration was(7.30±2.56) months. Pain was evaluated using the visual analogue scale (VAS), and lumbar spine function was assessed using the Oswestry disability index (ODI) and the Japanese Orthopaedic Association (JOA) score. VAS, ODI and JOA scores were compared between two groups before treatment and at 1, 3, 6, 9 and 12 months after treatment.
RESULTS:
All patients were followed up for 12 months. The VAS for the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(6.533±0.860), (5.133±1.008), (3.933±0.868), (2.900±0.759), (2.067±0.640), (1.433±0.504), respectively. In the McKenzie group, the corresponding scores were (6.467±0.860), (5.067±1.048), (4.600±0.968), (3.533±1.008), (2.567±0.728), (1.967±0.809), respectively. The ODI of the McKenzie group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were (41.033±6.810)%, (37.933±6.209)%, (35.467±6.962)%, (27.567±10.081)%, (20.800±7.531)%, (13.533±5.158)%, respectively. For the McKenzie combined with 3D printing group, the corresponding ODI were(38.033±5.605)%, (33.000±6.192)%, (28.767±7.045)%, (22.200±5.517)%, (17.700±4.836)%, (11.900±2.771)%, respectively. The JOA scores of the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(8.900±2.074), (13.133±2.330), (15.700±3.583), (20.400±3.480), (22.267±3.084), (24.833±2.640), respectively. In the McKenzie group, the corresponding scores were(9.200±2.091), (12.267±2.406), (15.333±3.198), (18.467±2.240), (20.133±2.751), (22.467±2.849), respectively. Before the initiation of treatment, no statistically significant differences were observed in the VAS, ODI, and JOA scores between two groups (P>0.05). At 3, 6, 9, and 12 months post-treatment, the VAS in the McKenzie combined with 3D printing group was significantly lower than that in the McKenzie group, and the difference was statistically significant (P<0.05). The comparison of ODI between two groups at 1, 3, 6, 9, and 12 months post-treatment revealed statistically significant differences (P<0.05). At 6, 9, and 12 months post-treatment, the JOA score in the McKenzie combined with 3D printing group was significantly higher than that in the McKenzie-only group, and the difference was statistically significant (P<0.05).
CONCLUSION
The combination of 3D printed functional spinal external fixation brace with McKenzie therapy can significantly improve and maintain lumbar function in patients with LDH.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Intervertebral Disc Displacement/surgery*
;
External Fixators
;
Lumbar Vertebrae/surgery*
;
Adult
;
Braces
;
Treatment Outcome

Result Analysis
Print
Save
E-mail