1.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*
2.Comparison of variable pressure mattress and thermoplastic mold in cone beam CT-guided radiotherapy of abdominal and pelvic cancer for setup error and effect of body mass index on setup reproducibility
Ling-xiao MIAO ; Jin-ye ZHAO ; Heng LI ; Feng-jiao SHAN ; Cui-hong ZHANG
Chinese Medical Equipment Journal 2025;46(7):45-50
Objective To explore the variable pressure matress and thermoplastic mold applied to cone beam CT-guided radiotherapy of abdominal and pelvic cancer in terms of translation error,rotation angle error and setup reproducibility of patients with different body mass indexes(BMIs),so as to provide references for the selection of body fixation mode.Methods Totally 70 patients with abdominal and pelvic tumors admitted to some hospital from April 2021 to March 2022 were retrospectively selected,and divided into a variable pressure mattress group and a thermoplastic mold group according to the fixation method,with 35 patients in each group.All the patients in the two groups underwent examinations with cone beam computed tomography(CBCT)at the first radiotherapy treatment and during the course of the treatment,and the image registration was carried out between validation images and planning images.The two groups were compared in terms of rotation angle error and thranlation error at the directoins of x axis(lateral directions),y axis(cranial-caudal)and z axis(ventral-dorsal).Taking the center point image of the initial positioning as the reference,the errors of the center points of the two groups at z and y axes(Δz and Δy)were compared.The setup reproducibility was set as Δz≤5 mm and Δy≤3 mm,and the setup reproducibility rates of the two groups were summarized.All the patients were categorized into non-overweight ones(BMI<25 kg/m2)and overweight ones(BMI≥25 kg/m2),and the setup reproducibility rates of the patients with different BMIs were counted.SPSS 26.0 software was used for statistical analysis.Results The two groups had no significant differences in translation error at the directions of x and y axes(P>0.05).The variable pressure mattress group had the translation error at the direction of z axis statistically lower than that of the thermoplastic mold group(P<0.05).There were no significant differences between the two groups in rotation angle error(P=0.219 3).The two groups had significant differences in setup reproducibility(P=0.033 4).The non-overweight patients had the setup reproducibility rate being 40.00%in the variable pressure mattress group,and 77.14%in the thermoplastic mold group;the overweight patients had the setup reproducibility rate being 25.71%in the variable pressure mattress group and only 2.86%in the thermoplastic mold group,with the differences between the two groups being statistically significant(P=0.002 9).Conclusion The variable pressure mattress and thermoplastic mold both result in low setup errors when applied to fixation during the radiotherapy of abdominal and pelvic cancer,the thermoplastic mold fixation can be used for the patients with BMIs lower than 25 kg/m2 with decreased translation errors at the direction of z axis,and the variable pressure mattress fixation was suitable for the patients with BMIs not lower than 25 kg/m2.[Chinese Medical Equipment Journal,2025,46(7):45-50]
3.Comparison of variable pressure mattress and thermoplastic mold in cone beam CT-guided radiotherapy of abdominal and pelvic cancer for setup error and effect of body mass index on setup reproducibility
Ling-xiao MIAO ; Jin-ye ZHAO ; Heng LI ; Feng-jiao SHAN ; Cui-hong ZHANG
Chinese Medical Equipment Journal 2025;46(7):45-50
Objective To explore the variable pressure matress and thermoplastic mold applied to cone beam CT-guided radiotherapy of abdominal and pelvic cancer in terms of translation error,rotation angle error and setup reproducibility of patients with different body mass indexes(BMIs),so as to provide references for the selection of body fixation mode.Methods Totally 70 patients with abdominal and pelvic tumors admitted to some hospital from April 2021 to March 2022 were retrospectively selected,and divided into a variable pressure mattress group and a thermoplastic mold group according to the fixation method,with 35 patients in each group.All the patients in the two groups underwent examinations with cone beam computed tomography(CBCT)at the first radiotherapy treatment and during the course of the treatment,and the image registration was carried out between validation images and planning images.The two groups were compared in terms of rotation angle error and thranlation error at the directoins of x axis(lateral directions),y axis(cranial-caudal)and z axis(ventral-dorsal).Taking the center point image of the initial positioning as the reference,the errors of the center points of the two groups at z and y axes(Δz and Δy)were compared.The setup reproducibility was set as Δz≤5 mm and Δy≤3 mm,and the setup reproducibility rates of the two groups were summarized.All the patients were categorized into non-overweight ones(BMI<25 kg/m2)and overweight ones(BMI≥25 kg/m2),and the setup reproducibility rates of the patients with different BMIs were counted.SPSS 26.0 software was used for statistical analysis.Results The two groups had no significant differences in translation error at the directions of x and y axes(P>0.05).The variable pressure mattress group had the translation error at the direction of z axis statistically lower than that of the thermoplastic mold group(P<0.05).There were no significant differences between the two groups in rotation angle error(P=0.219 3).The two groups had significant differences in setup reproducibility(P=0.033 4).The non-overweight patients had the setup reproducibility rate being 40.00%in the variable pressure mattress group,and 77.14%in the thermoplastic mold group;the overweight patients had the setup reproducibility rate being 25.71%in the variable pressure mattress group and only 2.86%in the thermoplastic mold group,with the differences between the two groups being statistically significant(P=0.002 9).Conclusion The variable pressure mattress and thermoplastic mold both result in low setup errors when applied to fixation during the radiotherapy of abdominal and pelvic cancer,the thermoplastic mold fixation can be used for the patients with BMIs lower than 25 kg/m2 with decreased translation errors at the direction of z axis,and the variable pressure mattress fixation was suitable for the patients with BMIs not lower than 25 kg/m2.[Chinese Medical Equipment Journal,2025,46(7):45-50]
4.Exosomal miRNA-222 Alerts shRNA-PCSK9 Induction Brain Tau Hyperphosphorylation
Lei WANG ; Qian JIANG ; Hong WANG ; Ling YUAN ; Nan LYU ; Di HAO ; Xiaoxue CUI ; Zi WANG
Chinese Journal of Modern Applied Pharmacy 2024;41(5):636-643
OBJECTIVE
To investigate whether the microRNA-222(miRNA-222) carried by plasma exosomes can serve as an early warning marker for cognitive impairment induced by shRNA-PCSK9.
METHODS
The high-fat diet(HFD) was used to prepare a hypercholesterolemic mouse model group. The model group mice were divided into HFD-shRNA control group and HFD-shRNA-PCSK9 group. The shRNA-PCSK9 was constructed, injected intravenously into the body, and the expression of PCSK9 mRNA was detected by real-time PCR(RT-PCR). Tau protein and phosphorylation in brain tissue were observed by immunohistochemistry (IHC). Western blotting was used to detect Tau protein and P-Tau protein. Serum amyloid Aβ1-42Ab levels were determined by ELISA. The kits extracted plasma exosomes step by step, identify the exosome morphology by negative staining electron microscopy, and determined the size of exosomes by NTA technology. RT-PCR technique was used to detect the expression level of miRNA-222 carried in plasma exosomes.
RESULTS
The model mouse were prepared by feeding HFD for 13 weeks, whose total cholesterol(TC) and low-density lipoprotein(LDL-C) contents in serum were significantly increased. At the same time, the expression of PCSK9 mRNA in the brain tissue of model group was significantly increased. After shRNA-PCSK9 lentivirus interference, PCSK9 mRNA expression was inhibited, and IHC observed that shRNA-PCSK9 induced abnormal expression and hyperphosphorylation of Tau protein in brain tissue, indicating that the pathological changes of neurofibrillary tangles had occurred. However, at this time, serum Aβ1-42Ab had not been significantly increased, and it had not yet been of significance for the diagnosis of cognitive impairment. The miRNA in plasma exosomes was extracted, and RT-PCR results showed that the expression of miRNA-222 carried in the exosomes of the HFD-shRNA-PCSK9 group was significantly lower than that of the HFD-shRNA control group.
CONCLUSION
Plasma exosomes carried miRNA-222 provides an early warning marker for shRNA-PCSK9- induced cognitive impairment.
5.Latent tuberculosis infection among close contacts of positive etiology pul-monary tuberculosis in Chongqing
Rong-Rong LEI ; Hong-Xia LONG ; Cui-Hong LUO ; Ben-Ju YI ; Xiao-Ling ZHU ; Qing-Ya WANG ; Ting ZHANG ; Cheng-Guo WU ; Ji-Yuan ZHONG
Chinese Journal of Infection Control 2024;23(3):265-270
Objective To investigate the current situation and influencing factors of latent tuberculosis infection(LTBI)among close contacts of positive etiology pulmonary tuberculosis(PTB)patients,provide basis for formula-ting intervention measures for LTBI.Methods A multi-stage stratified cluster random sampling method was used to select close contacts of positive etiology PTB patients from 39 districts and counties in Chongqing City as the study objects.Demographic information was collected by questionnaire survey and the infection of Mycobacterium tuberculosis was detected by interferon gamma release assay(IGRA).The influencing factors of LTBI were analyzed by x2 test and binary logistic regression model.Results A total of 2 591 close contacts were included,the male to female ratio was 0.69∶1,with the mean age of(35.72±16.64)years.1 058 cases of LTBI were detected,Myco-bacterium tuberculosis latent infection rate was 40.83%.Univariate analysis showed that the infection rate was dif-ferent among peoples of different age,body mass index(BMI),occupation,education level,marital status,wheth-er they had chronic disease or major surgery history,whether they lived together with the indicator case,and whether the cumulative contact time with the indicator case ≥250 hours,difference were all statistically significant(all P<0.05);infection rate presented increased trend with the increase of age and BMI(both P<0.001),and decreased trend with the increase of education(P<0.05).Logistic regression analysis showed that age 45-54 years old(OR=1.951,95%CI:1.031-3.693),age 55-64 years old(OR=2.473,95%CI:1.279-4.781),other occupations(OR=0.530,95%CI:0.292-0.964),teachers(OR=0.439,95%CI:0.242-0.794),students(OR=0.445,95%CI:0.233-0.851),junior high school education or below(OR=1.412,95%CI:1.025-1.944),BMI<18.5 kg/m2(OR=0.762,95%CI:0.586-0.991),co-living with indicator cases(OR=1.621,95%CI1.316-1.997)and cumu-lative contact time with indicator cases ≥250 hours(OR=1.292,95%CI:1.083-1.540)were the influential fac-tors for LTBI(all P<0.05).Conclusion The close contacts with positive etiology PTB have a high latent infection rate of Mycobacterium tuberculosis,and it is necessary to pay attention to close contacts of high age,farmers,and frequent contact with patients,and take timely targeted interventions to reduce the risk of occurrence of disease.
6.The Uptake and Distribution Evidence of Nano-and Microplastics in vivo after a Single High Dose of Oral Exposure
Tao HONG ; Wei SUN ; Yuan DENG ; Da Jian LYU ; Hong Cui JIN ; Long Ying BAI ; Jun NA ; Rui ZHANG ; Yuan GAO ; Wei Guo PAN ; Sen Zuo YANG ; Jun Ling YAN
Biomedical and Environmental Sciences 2024;37(1):31-41
Objective Tissue uptake and distribution of nano-/microplastics was studied at a single high dose by gavage in vivo.Methods Fluorescent microspheres (100 nm, 3 μm, and 10 μm) were given once at a dose of 200 mg/(kg·body weight). The fluorescence intensity (FI) in observed organs was measured using the IVIS Spectrum at 0.5, 1, 2, and 4 h after administration. Histopathology was performed to corroborate these findings.Results In the 100 nm group, the FI of the stomach and small intestine were highest at 0.5 h, and the FI of the large intestine, excrement, lung, kidney, liver, and skeletal muscles were highest at 4 h compared with the control group (P < 0.05). In the 3 μm group, the FI only increased in the lung at 2 h (P < 0.05). In the 10 μm group, the FI increased in the large intestine and excrement at 2 h, and in the kidney at 4 h (P < 0.05). The presence of nano-/microplastics in tissues was further verified by histopathology. The peak time of nanoplastic absorption in blood was confirmed.Conclusion Nanoplastics translocated rapidly to observed organs/tissues through blood circulation;however, only small amounts of MPs could penetrate the organs.
7.Evaluation of drug local tolerance testing and analysis of common problems
Mei-Ling CHEN ; Qing-Li WANG ; Hong-Mei GUANG ; Lan CUI ; Xiao-Dong ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(1):139-143
Conducting local tolerance testing on parentaral drugs is of great significance for evaluating the clinical medication risks of drugs.Although relevant domestic and international guidelines provide detailed instructions on how to conduct local tolerance testing,it was found that some products still provide non-standard application materials,which affects the efficiency of drug development.This article summarizes the information on domestic and international guidance related to the local tolerance testing and elaborates on common problems based on specific application cases,with the aim of of providing reference for related work.
8.Discussion of the methodology and implementation steps for assessing the causality of adverse event
Hong FANG ; Shuo-Peng JIA ; Hai-Xue WANG ; Xiao-Jing PEI ; Min LIU ; An-Qi YU ; Ling-Yun ZHOU ; Fang-Fang SHI ; Shu-Jie LU ; Shu-Hang WANG ; Yue YU ; Dan-Dan CUI ; Yu TANG ; Ning LI ; Ze-Huai WEN
The Chinese Journal of Clinical Pharmacology 2024;40(2):299-304
The assessment of adverse drug events is an important basis for clinical safety evaluation and post-marketing risk control of drugs,and its causality assessment is gaining increasing attention.The existing methods for assessing the causal relationship between drugs and the occurrence of adverse reactions can be broadly classified into three categories:global introspective methods,standardized methods,and probabilistic methods.At present,there is no systematic introduction of the operational details of the various methods in the domestic literature.This paper compares representative causality assessment methods in terms of definition and concept,methodological steps,industry evaluation and advantages and disadvantages,clarifies the basic process of determining the causality of adverse drug reactions,and discusses how to further improve the adverse drug reaction monitoring and evaluation system,with a view to providing a reference for drug development and pharmacovigilance work in China.
9.Preparation of Metal Organic Framework-derived Microflower-Like NiO-In2O3 Composite Structure and Its Detection Performance for Ultra-Low Concentration of Formaldehyde Gas
Cui-Xian LUO ; Jiao-Hong HOU ; Wen-Tao JIA ; Da-Ming WANG ; Ling-Rong XUE
Chinese Journal of Analytical Chemistry 2024;52(8):1141-1151
Formaldehyde is a prevalent organic solvent in industrial and indoor environment,which can seriously harm human health,so it is of great significance to develop highly sensitive formaldehyde sensors with fast response,low detection limit and long life.In this study,the NiO-In2O3 composite structure was prepared using indium-based metal organic framework(In-MOF)as the precursor,and the formaldehyde gas sensor was constructed with In2O3 and NiO-In2O3 composite structure as the sensitive material.The results demonstrated that the In2O3 material had a microflower-like structure,while the NiO-In2O3 composite structure was composed of NiO nanoparticles attached to the surface of In2O3.The sensor exhibited excellent detection performance for formaldehyde in the environment of relative humidity of 33%and 75%,especially the response characteristic of the NiO-In2O3 composite structure sensor to formaldehyde was considerably better than that of the In2O3 sensor under the same test conditions,which was closely related to the catalytic effect of NiO and the heterogeneous structure formed between NiO and In2O3.The NiO-In2O3 composite structure sensor had a response value of 21.3 and 12.6 to 10 μL/L formaldehyde when the relative humidity was 33%and 75%at 200℃.The response/recovery time was 4/6 s and 7/10 s,and the limit of detection(LOD)was 1.2×10-7 μL/L and 4.1×10-5 μL/L respectively.Meanwhile,the sensor had excellent selectivity and long-term stability.This sensor showed a wide application prospect in the field of high-performance detection of low concentration of formaldehyde gas.
10.Predictive performance of the variation rate of the driving pressure on the outcome of invasive mechanical ventilation in patients with acute respiratory distress syndrome
Hui-Dan JING ; Jun-Ying TIAN ; Wei LI ; Bing-Ling HE ; Hong-Chao LI ; Fu-Xia JIAN ; Cui SHANG ; Feng SHEN
Chinese Journal of Traumatology 2024;27(2):107-113
Purpose::To assess the value of the driving pressure variation rate (ΔP%) in predicting the outcome of weaning from invasive mechanical ventilation in patients with acute respiratory distress syndrome.Methods::In this case-control study, a total of 35 patients with moderate-severe acute respiratory distress syndrome were admitted to the intensive care unit between January 2022 and December 2022 and received invasive mechanical ventilation for at least 48 h were enrolled. Patients were divided into successful weaning group and failed weaning group depending on whether they could be removed from ventilator support within 14 days. Outcome measures including driving pressure, PaO 2:FiO 2, and positive end-expiratory pressure, etc. were assessed every 24 h from day 0 to day 14 until successful weaning was achieved. The measurement data of non-normal distribution were presented as median (Q 1, Q 3), and the differences between groups were compared by Wilcoxon rank sum test. And categorical data use the Chi-square test or Fisher's exact test to compare. The predictive value of ΔP% in predicting the outcome of weaning from the ventilator was analyzed using receiver operating characteristic curves. Results::Of the total 35 patients included in the study, 17 were successful vs. 18 failed in weaning from a ventilator after 14 days of mechanical ventilation. The cut-off values of the median ΔP% measured by Operator 1 vs. Operator 2 in the first 4 days were ≥ 4.17% and 4.55%, respectively ( p < 0.001), with the area under curve of 0.804 (sensitivity of 88.2%, specificity of 64.7%) and 0.770 (sensitivity of 88.2%, specificity of 64.7%), respectively. There was a significant difference in mechanical ventilation duration between the successful weaning group and the failure weaning group (8 (6, 13) vs. 12 (7.5, 17.3), p = 0.043). The incidence of ventilator-associated pneumonia in the successful weaning group was significantly lower than in the failed weaning group (0.2‰ vs. 2.3‰, p = 0.001). There was a significant difference noted between these 2 groups in the 28-day mortality (11.8% vs. 66.7%, p = 0.003). Conclusion::The median ΔP% in the first 4 days of mechanical ventilation showed good predictive performance in predicting the outcome of weaning from mechanical ventilation within 14 days. Further study is needed to confirm this finding.


Result Analysis
Print
Save
E-mail