1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Research progress on autophagy in optic nerve injury
International Eye Science 2025;25(10):1604-1610
The damage and death of retinal ganglion cells(RGCs)are central pathological events in optic nerve injury, leading to irreversible visual impairment. Autophagy, a regulated process of cellular degradation and death, is involved in the pathogenesis of various diseases, including tumors, neurological damage, and autoimmune disorders. Current research indicates that autophagy is significantly upregulated following optic nerve injury, exhibiting a dual role: while it may mediate cellular damage in the early stages, it tends to promote neuroprotection and axonal regeneration in later phases. Moreover, the activation of autophagy in microglia may play a crucial role in regulating their activation phenotype and neuroinflammation. Precisely modulating autophagy to promote RGCs survival and improve visual function has become a key challenge in the treatment of optic nerve injury. This review summarizes the role of autophagy in optic nerve injury and its therapeutic interventions.
7.Identification of novel pathogenic variants in genes related to pancreatic β cell function: A multi-center study in Chinese with young-onset diabetes.
Fan YU ; Yinfang TU ; Yanfang ZHANG ; Tianwei GU ; Haoyong YU ; Xiangyu MENG ; Si CHEN ; Fengjing LIU ; Ke HUANG ; Tianhao BA ; Siqian GONG ; Danfeng PENG ; Dandan YAN ; Xiangnan FANG ; Tongyu WANG ; Yang HUA ; Xianghui CHEN ; Hongli CHEN ; Jie XU ; Rong ZHANG ; Linong JI ; Yan BI ; Xueyao HAN ; Hong ZHANG ; Cheng HU
Chinese Medical Journal 2025;138(9):1129-1131
8.Thiotepa-containing conditioning for allogeneic hematopoietic stem cell transplantation in children with inborn errors of immunity: a retrospective clinical analysis.
Xiao-Jun WU ; Xia-Wei HAN ; Kai-Mei WANG ; Shao-Fen LIN ; Li-Ping QUE ; Xin-Yu LI ; Dian-Dian LIU ; Jian-Pei FANG ; Ke HUANG ; Hong-Gui XU
Chinese Journal of Contemporary Pediatrics 2025;27(10):1240-1246
OBJECTIVES:
To evaluate the safety and efficacy of thiotepa (TT)-containing conditioning regimens for allogeneic hematopoietic stem cell transplantation (HSCT) in children with inborn errors of immunity (IEI).
METHODS:
Clinical data of 22 children with IEI who underwent HSCT were retrospectively reviewed. Survival after HSCT was estimated using the Kaplan-Meier method.
RESULTS:
Nine patients received a traditional conditioning regimen (fludarabine + busulfan + cyclophosphamide/etoposide) and underwent peripheral blood stem cell transplantation (PBSCT). Thirteen patients received a TT-containing modified conditioning regimen (TT + fludarabine + busulfan + cyclophosphamide), including seven PBSCT and six umbilical cord blood transplantation (UCBT) cases. Successful engraftment with complete donor chimerism was achieved in all patients. Acute graft-versus-host disease occurred in 12 patients (one with grade III and the remaining with grade I-II). Chronic graft-versus-host disease occurred in one patient. The incidence of EB viremia in UCBT patients was lower than that in PBSCT patients (P<0.05). Over a median follow-up of 36.0 months, one death occurred. The 3-year overall survival (OS) rate was 100% for the modified regimen and 88.9% ± 10.5% for the traditional regimen (P=0.229). When comparing transplantation types, the 3-year OS rates were 100% for UCBT and 93.8% ± 6.1% for PBSCT (P>0.05), and the 3-year event-free survival rates were 100% and 87.1% ± 8.6%, respectively (P>0.05).
CONCLUSIONS
TT-containing conditioning for allogeneic HSCT in children with IEI is safe and effective. Both UCBT and PBSCT may achieve high success rates.
Humans
;
Retrospective Studies
;
Transplantation Conditioning/methods*
;
Thiotepa/therapeutic use*
;
Hematopoietic Stem Cell Transplantation/adverse effects*
;
Male
;
Female
;
Child, Preschool
;
Infant
;
Child
;
Transplantation, Homologous
;
Graft vs Host Disease
;
Adolescent
9.Impact of sutureless dorsal venous complex combined with robotic-assisted laparoscopic prostatectomy on sexual function in patients with prostatic cancer.
Wei ZHENG ; Xin-Mian HUANG ; Xiao-Bo XU ; Ke-Bing YANG ; Xiao-Long QI ; Da-Hong ZHANG
National Journal of Andrology 2025;31(9):807-811
OBJECTIVE:
To evaluate the impact of sutureless approach to the dorsal venous complex (DVC) combined with robotic-assisted laparoscopic prostatectomy on sexual function of patients with prostatic cancer.
METHODS:
This study included 114 prostate cancer patients who underwent robot-assisted laparoscopic radical prostatectomy at our hospital from January 2021 to January 2024. The patients were randomly divided into a control group (n=57) and an observation group (n=57). The control group received conventional "figure-of-eight" suture ligation of the dorsal venous complex (DVC), while the observation group underwent direct DVC transection using monopolar electrocautery scissors after increasing pneumoperitoneum pressure.Surgical duration, intraoperative blood loss, positive surgical margin rates, and positive apical margin rates were recorded. The continence rates and rates of morning erections at 1, 3 and 6 months after the operation were compared between groups. Sexual function was assessed pre-operatively and at 6 months post-operation by using the IIEF-5 and PEDT.
RESULTS:
The operative time in the observation group was significantly longer than that in the control group ([115.71 ± 19.42] min vs [103.42 ± 12.78] min, P<0.05). While no significant differences were observed in intraoperative blood loss, positive surgical margin rate, or positive apical margin rate between the two groups (P>0.05). At 3 and 6 months after the operation, the observation group exhibited higher urinary continence rates and morning erection recovery rates compared to the control group (P<0.05). Furthermore, at 6 months postoperatively, the observation group demonstrated significantly higher IIEF-5 scores and lower PEDT scores than those of control group(P<0.05).
CONCLUSION
The use of a sutureless DVC technique in robotic-assisted laparoscopic radical prostatectomy protects the post-operative sexual function in patients.
Humans
;
Male
;
Prostatectomy/methods*
;
Laparoscopy/methods*
;
Prostatic Neoplasms/surgery*
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Operative Time
;
Aged

Result Analysis
Print
Save
E-mail