1.Safety and efficacy of immunoadsorption therapy for rheumatoid arthritis:a network meta-analysis and systematic review
Yin ZHENG ; Zhenhua WU ; Cheng ZHANG ; Kexin RUAN ; Xiaolin GANG ; Hong JI
Chinese Journal of Tissue Engineering Research 2026;30(5):1260-1268
OBJECTIVE:To evaluate the efficacy and safety of different immunosorbent columns in the treatment of rheumatoid arthritis through a network meta-analysis,and provide evidence-based basis for clinical diagnosis and treatment.METHODS:By computer,the databases of VIP,WanFang,CNKI,PubMed,CBM,CochraneLibrary,and Web of Science were searched for published cohort studies of immunosorbent column for the treatment of rheumatoid arthritis,with a time limit until August 2024.The quality of the included randomized controlled trials was assessed using the Cochrane5.4 manual.The quality of retrospective cohort studies were evaluated via the Newcastle-Ottawa Scale(NOS).Bayesian network meta-analysis was performed using R4.1.1 software.RESULTS:A total of 13 studies were included,with a total sample size of 891 cases,and 4 immunosorbent columns were included.The results of the network meta-analysis showed that the top three orders that reduce C-reactive protein level:HA280 adsorption column+conventional Western medicine>PH-350 adsorption column+conventional Western medicine>A protein adsorption column;the top three orders that reduce erythrocyte sedimentation rates:leukocyte adsorption column>HA280 adsorption column+conventional Western medicine>PH-350 adsorption column+conventional western medicine;the top three orders that reduce swollen joint count:leukocyte adsorption column>A protein adsorption column+conventional western medicine>PH-350 type adsorption column+conventional Western medicine;the top three orders that reduce tenderness joint counts:leukocyte adsorption column>A protein adsorption column+conventional western medicine>PH-350 adsorption column+conventional Western medicine;the top three orders that reduce patients' disease activity evaluation:PH-350 adsorption column+conventional western medicine>leukocyte adsorption column>A protein adsorption column;the top three orders that reduce visual analogue scale scores:PH-350 adsorption column+conventional Western medicine>A protein adsorption column>leukocyte adsorption column;the top three orders that reduce physician's disease activity assessment:PH-350 adsorption column+conventional Western medicine>leukocyte adsorption column>conventional Western medicine.CONCLUSION:Based on the 13 articles,in terms of reducing C-reactive protein level,HA280 adsorption column and conventional Western medicine are the preferred choice.In terms of reducing erythrocyte sedimentation rate,swollen joint count,and tender joint count,leukocyte adsorption column is the preferred choice.In terms of reducing patient's disease activity evaluation,physician's disease activity evaluation and visual analogue scale scores,PH-350 adsorption column and conventional Western medicine are the first choice.Different immunosorbent columns can be reasonably and accurately selected according to the patient's specific conditions.
2.Safety and efficacy of immunoadsorption therapy for rheumatoid arthritis:a network meta-analysis and systematic review
Yin ZHENG ; Zhenhua WU ; Cheng ZHANG ; Kexin RUAN ; Xiaolin GANG ; Hong JI
Chinese Journal of Tissue Engineering Research 2026;30(5):1260-1268
OBJECTIVE:To evaluate the efficacy and safety of different immunosorbent columns in the treatment of rheumatoid arthritis through a network meta-analysis,and provide evidence-based basis for clinical diagnosis and treatment.METHODS:By computer,the databases of VIP,WanFang,CNKI,PubMed,CBM,CochraneLibrary,and Web of Science were searched for published cohort studies of immunosorbent column for the treatment of rheumatoid arthritis,with a time limit until August 2024.The quality of the included randomized controlled trials was assessed using the Cochrane5.4 manual.The quality of retrospective cohort studies were evaluated via the Newcastle-Ottawa Scale(NOS).Bayesian network meta-analysis was performed using R4.1.1 software.RESULTS:A total of 13 studies were included,with a total sample size of 891 cases,and 4 immunosorbent columns were included.The results of the network meta-analysis showed that the top three orders that reduce C-reactive protein level:HA280 adsorption column+conventional Western medicine>PH-350 adsorption column+conventional Western medicine>A protein adsorption column;the top three orders that reduce erythrocyte sedimentation rates:leukocyte adsorption column>HA280 adsorption column+conventional Western medicine>PH-350 adsorption column+conventional western medicine;the top three orders that reduce swollen joint count:leukocyte adsorption column>A protein adsorption column+conventional western medicine>PH-350 type adsorption column+conventional Western medicine;the top three orders that reduce tenderness joint counts:leukocyte adsorption column>A protein adsorption column+conventional western medicine>PH-350 adsorption column+conventional Western medicine;the top three orders that reduce patients' disease activity evaluation:PH-350 adsorption column+conventional western medicine>leukocyte adsorption column>A protein adsorption column;the top three orders that reduce visual analogue scale scores:PH-350 adsorption column+conventional Western medicine>A protein adsorption column>leukocyte adsorption column;the top three orders that reduce physician's disease activity assessment:PH-350 adsorption column+conventional Western medicine>leukocyte adsorption column>conventional Western medicine.CONCLUSION:Based on the 13 articles,in terms of reducing C-reactive protein level,HA280 adsorption column and conventional Western medicine are the preferred choice.In terms of reducing erythrocyte sedimentation rate,swollen joint count,and tender joint count,leukocyte adsorption column is the preferred choice.In terms of reducing patient's disease activity evaluation,physician's disease activity evaluation and visual analogue scale scores,PH-350 adsorption column and conventional Western medicine are the first choice.Different immunosorbent columns can be reasonably and accurately selected according to the patient's specific conditions.
3.Expert consensus on visualized tele-round and quality control management based on the improvement of clinical practice ability
Wanhong YIN ; Xiaoting WANG ; Ran ZHOU ; Dawei LIU ; Yan KANG ; Yaoqing TANG ; Xiaochun MA ; Jianguo LI ; Zhenjie HU ; Haitao ZHANG ; Wei HE ; Lixia LIU ; Wenjin CHEN ; Ran ZHU ; Jun WU ; Hongmin ZHANG ; Lina ZHANG ; Wenzhao CHAI ; Shihong ZHU ; Wangbin XU ; Rongqing SUN ; Xiangyou YU ; Tianjiao SONG ; Ying ZHU ; Hong REN ; Ai SHANMU ; Qing ZHANG ; Wei FANG ; Xiuling SHANG ; Liwen LYU ; Shuhan CAI ; Xin DING ; Heng ZHANG ; Guang FENG ; Lipeng ZHANG ; Bo HU ; Dong ZHANG ; Weidong WU ; Feng SHEN ; Xiaojun YANG ; Zhenguo ZENG ; Qibing HUANG ; Xueying ZENG ; Tongjuan ZOU ; Milin PENG ; Yulong YAO ; Mingming CHEN ; Hui LIAN ; Jingmei WANG ; Yong LI ; Feng QU ; Gang YE ; Rongli YANG ; Xiukai CHEN ; Suwei LI ; Juxiang WANG ; Yangong CHAO
Chinese Journal of Internal Medicine 2025;64(2):101-109
Turning to critical illness is a common stage of various diseases and injuries before death. Patients usually have complex health conditions, while the treatment process involves a wide range of content, along with high requirements for doctor′s professionalism and multi-specialty teamwork, as well as a great demand for time-sensitive treatments. However, this is not matched with critical care professionals and the current state of medical care in China. Telemedicine, which shortens the distance of medical professionals and the gap of disease diagnosis and treatments in various regions through electronic information, can effectively solve the current problem. Therefore, there is an urgent need to develop a standardized, high-quality visualization telemedicine round system .Therefore, experts have been organized to search domestic and foreign literature on telemedicine round for critically ill patients and to form this consensus based on clinical experiences so as to further improve the level of critical care treatments in regions.
4.Evaluation of chemical constituent consistency in formula granules and traditional decoctions of Gouteng Jiangya Formula
Qing-gang ZHANG ; Dai-liang ZHANG ; Hong QI ; Shu-wen DING ; Yu-zhuo WANG ; Yun-lun LI ; Ji-fu HE ; Huan-ying GUO ; Gui-yun CAO ; Zhao-qing MENG
Chinese Traditional Patent Medicine 2025;47(11):3555-3565
AIM To evaluate the chemical constituent consistency in formula granules and traditional decoctions of Gouteng Jiangya Formula.METHODS HPLC characteristic chromatograms were established,the analysis was performed on a 30 ℃ thermostatic YMC-Triart C18 column(4.6 mm× 250 mm,5 μm),with the mobile phase comprising of acetonitrile-0.2%phosphoric acid flowing at 1.0 mL/min in a gradient elution manner,and the detection wavelength was set at 240 nm.Puerarin was used as an internal standard to calculate the relative correction factors of 3'-methoxy puerarin,puerarin apioside,magnolflorine,paeoniflora,daidzin,baicalin,palmatine,berberine,wogonoside and benzoylpaeoniflorin,after which the content detemination was made by quantitative analysis of multi-components by single-marker(QAMS).RESULTS The characteristic chromatograms of 9 batches of formula granules and 15 bacthes of traditional decoctions demonstrated the similarities of more than 0.90 at the detection wavelengths of 192,210,240,260,280,300,320,360 nm,along with similar total peak areas.Eleven constituents showed good linear relationships within their own ranges(r>0.999 0),whose average recoveries were 97.27%-101.64%with the RSDs of 0.36%-1.11%,the result obtained by QAMS and external standard method demonstrated no significant differences(P>0.05).The contents of various constituents in the formula granules approximated those in the traditional decoctions.CONCLUSION The consistent kinds and contents of various constituents are obversable in formula granules and traditional decoctions of Gouteng Jiangya Formula,which can provide a reference for the reasonable clinical application of this formula.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Expert consensus on imaging diagnosis and analysis of early correction of childhood malocclusion.
Zitong LIN ; Chenchen ZHOU ; Ziyang HU ; Zuyan ZHANG ; Yong CHENG ; Bing FANG ; Hong HE ; Hu WANG ; Gang LI ; Jun GUO ; Weihua GUO ; Xiaobing LI ; Guangning ZHENG ; Zhimin LI ; Donglin ZENG ; Yan LIU ; Yuehua LIU ; Min HU ; Lunguo XIA ; Jihong ZHAO ; Yaling SONG ; Huang LI ; Jun JI ; Jinlin SONG ; Lili CHEN ; Tiemei WANG
International Journal of Oral Science 2025;17(1):21-21
Early correction of childhood malocclusion is timely managing morphological, structural, and functional abnormalities at different dentomaxillofacial developmental stages. The selection of appropriate imaging examination and comprehensive radiological diagnosis and analysis play an important role in early correction of childhood malocclusion. This expert consensus is a collaborative effort by multidisciplinary experts in dentistry across the nation based on the current clinical evidence, aiming to provide general guidance on appropriate imaging examination selection, comprehensive and accurate imaging assessment for early orthodontic treatment patients.
Humans
;
Malocclusion/diagnostic imaging*
;
Child
;
Consensus
10.Expert consensus on the prevention and treatment of radiochemotherapy-induced oral mucositis.
Juan XIA ; Xiaoan TAO ; Qinchao HU ; Wei LUO ; Xiuzhen TONG ; Gang ZHOU ; Hongmei ZHOU ; Hong HUA ; Guoyao TANG ; Tong WU ; Qianming CHEN ; Yuan FAN ; Xiaobing GUAN ; Hongwei LIU ; Chaosu HU ; Yongmei ZHOU ; Xuemin SHEN ; Lan WU ; Xin ZENG ; Qing LIU ; Renchuan TAO ; Yuan HE ; Yang CAI ; Wenmei WANG ; Ying ZHANG ; Yingfang WU ; Minhai NIE ; Xin JIN ; Xiufeng WEI ; Yongzhan NIE ; Changqing YUAN ; Bin CHENG
International Journal of Oral Science 2025;17(1):54-54
Radiochemotherapy-induced oral mucositis (OM) is a common oral complication in patients with tumors following head and neck radiotherapy or chemotherapy. Erosion and ulcers are the main features of OM that seriously affect the quality of life of patients and even the progress of tumor treatment. To date, differences in clinical prevention and treatment plans for OM have been noted among doctors of various specialties, which has increased the uncertainty of treatment effects. On the basis of current research evidence, this expert consensus outlines risk factors, clinical manifestations, clinical grading, ancillary examinations, diagnostic basis, prevention and treatment strategies and efficacy indicators for OM. In addition to strategies such as basic oral care, anti-inflammatory and analgesic agents, anti-infective agents, pro-healing agents, and photobiotherapy recommended in previous guidelines, we also emphasize the role of traditional Chinese medicine in OM prevention and treatment. This expert consensus aims to provide references and guidance for dental physicians and oncologists in formulating strategies for OM prevention, diagnosis, and treatment, standardizing clinical practice, reducing OM occurrence, promoting healing, and improving the quality of life of patients.
Humans
;
Chemoradiotherapy/adverse effects*
;
Consensus
;
Risk Factors
;
Stomatitis/etiology*

Result Analysis
Print
Save
E-mail