1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Efficacy and safety of proximal gastrectomy versus total gastrectomy for Siewert type Ⅱ and Ⅲ adenocarcinoma of the esophagogastric junction: A systematic review and meta-analysis
Yingjie LU ; Ziqiang HONG ; Hongchao LI ; Gang JIN ; Wenhao WANG ; Yi YANG ; Bin LIU ; Zijiang ZHU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(05):693-699
Objective To systematically evaluate the efficacy and safety of proximal gastrectomy (PG) versus total gastrectomy (TG) for the treatment of Siewert type Ⅱ/Ⅲ adenocarcinoma of the esophagogastric junction (AEG). Methods PubMed, The Cochrane Library, Web of Science, EMbase, CNKI, Wanfang, and VIP databases were searched for literature comparing the efficacy and safety of PG and TG for the treatment of Siewert type Ⅱ/Ⅲ AEG. The search period was from database inception to March 2023. Meta-analysis was performed using Review Manager 5.4 software. Results A total of 23 articles were included, including 16 retrospective cohort studies, 5 prospective cohort studies, and 2 randomized controlled trials. The total sample size was 2 826 patients, with 1 389 patients undergoing PG and 1 437 patients undergoing TG. Meta-analysis results showed that compared with TG, PG had less intraoperative blood loss [MD=−19.85, 95%CI (−37.20, −2.51), P=0.02] and shorter postoperative hospital stay [MD=−1.23, 95%CI (−2.38, −0.08), P=0.04]. TG had a greater number of lymph nodes dissected [MD=−6.20, 95%CI (−7.68, −4.71), P<0.001] and a lower incidence of reflux esophagitis [MD=3.02, 95%CI (1.24, 7.34), P=0.01]. There were no statistically significant differences between the two surgical approaches in terms of operative time, postoperative survival rate (1-year, 3-year, 5-year), and postoperative overall complications (P>0.05). Conclusion PG has advantages in terms of intraoperative blood loss and postoperative hospital stay, while TG has advantages in terms of the number of lymph nodes dissected and the incidence of reflux esophagitis. There is no significant difference in long-term survival between the two surgical approaches.
7.Clinical efficacy of endocrinotherapy combined with Shenqi Pills on patients with hormone-sensitive prostate cancer.
Yu-Hong XIE ; Gang YI ; Xiao-Wen YI ; Tong-Lin SUN ; Qun-Fang LIN ; Jun ZHOU ; Xin-Jun LUO ; Fang-Zhi FU ; Biao WANG ; Qin-Zheng WANG ; Lie ZHANG ; Yang YANG ; Rui-Song GAO ; Qing ZHOU
National Journal of Andrology 2025;31(4):341-348
OBJECTIVE:
The aim of this study is to explore the clinical efficacy and safety of endocrinotherapy combined with Shenqi Pills on hormone-sensitive prostate cancer (HSPC).
METHODS:
Eighty patients who were diagnosed with HSPC and renal-yang deficiency at the First Affiliated Hospital of Hunan University of Traditional Chinese Medicine and the Hospital of Traditional Chinese Medicine of Mayang Miao Autonomous County from 1st April 2021 to 30th April 2024 were randomly divided into 2 groups. The patients in the control group were treated with androgen deprivation therapy (ADT). And the patients in treatment group were treated with Shenqi Pills orally on the basis of the control group. The baseline data of the two groups were analyzed. After 36 months of treatment, the differences between the two groups were compared in terms of overall survival (OS), prostate-specific antigen (PSA) level, PSA response rate, Functional Assessment Scale for Prostate Cancer Therapy (FACT-P), Chinese medicine evidence scores, testosterone level and safety.
RESULTS:
A total of 80 study subjects were included in this study, including 42 cases in the treatment group and 38 cases in the control group. There was no statistical difference in the baseline data between the two groups before treatment (P>0.05). At the end of the observation period, a statistically significant difference in OS was found in the treatment group compared to the control group in the subgroup of patients with a disease duration ranged of 0-6 months (P<0.05). There was no statistically significant difference in PSA levels in the treatment group at 3 months (P>0.05). And the differences in the proportion of PSA50 (98.1% vs 91.4%), PSA90 (92.9% vs 84.6%) and the proportion of decrease in PSA (56.7% vs 33.8%) in the treatment group were found compared to those in the control group after 6 months of tre atment. After 12 months of treatment, the scores of FACT-4 and renal-yang deficiency in the treatment group were (95.28±7.93) and (15.73±5.70) respectively, compared to the scores in the control group ([85.46±10.12] and [18.20±4.27] (P<0.05). However, there was no significant difference in serum testosterone ([0.60±0.24] nmol/L vs [1.09±2.10] nmol/L) between the two groups (P>0.05). After 24 months of treatment, there were significant differences in in the FACT-4 total score ([97.95±7.54] vs [80.33±8.58]), renal-yang deficiency syndrome score ([14.64±5.15] vs [24.94±8.75]) between the treatment group and the control group (P<0.05). However, there was no significant difference in serum testosterone ( [0.73±1.01] nmol/L vs [0.59±0.25] nmol/L) between the two groups (P> 0.05). Better therapeutic results were showed in the treatment group in terms of total FACT-P score, physical situation score, social and family situation score, emotional state score, functional state score, additional score and renal-yang deficiency symptom score (P<0.05). After treatment, there was no serious adverse reaction in the course of treatment, and no obvious abnormality was found in the liver and kidney function of the patients from two groups.
CONCLUSION
Endocrinotherapy combined with Shenqi Pills is safe and effective in HSPC and can reduce the risk of death in HSPC patients, and the earlier the intervention, the longer the overall survival of the patients. In addition, this treatment regimen can increase the PSA response rate, improve patients' quality of life, and reduce the renal-yang deficiency syndrome score without the risk of elevating serum testosterone levels.
Humans
;
Male
;
Drugs, Chinese Herbal/therapeutic use*
;
Prostatic Neoplasms/drug therapy*
;
Androgen Antagonists/therapeutic use*
;
Prostate-Specific Antigen/blood*
;
Aged
;
Middle Aged
;
Treatment Outcome
;
Testosterone
8.Qingda Granule Attenuates Hypertension-Induced Cardiac Damage via Regulating Renin-Angiotensin System Pathway.
Lin-Zi LONG ; Ling TAN ; Feng-Qin XU ; Wen-Wen YANG ; Hong-Zheng LI ; Jian-Gang LIU ; Ke WANG ; Zhi-Ru ZHAO ; Yue-Qi WANG ; Chao-Ju WANG ; Yi-Chao WEN ; Ming-Yan HUANG ; Hua QU ; Chang-Geng FU ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(5):402-411
OBJECTIVE:
To assess the efficacy of Qingda Granule (QDG) in ameliorating hypertension-induced cardiac damage and investigate the underlying mechanisms involved.
METHODS:
Twenty spontaneously hypertensive rats (SHRs) were used to develope a hypertension-induced cardiac damage model. Another 10 Wistar Kyoto (WKY) rats were used as normotension group. Rats were administrated intragastrically QDG [0.9 g/(kg•d)] or an equivalent volume of pure water for 8 weeks. Blood pressure, histopathological changes, cardiac function, levels of oxidative stress and inflammatory response markers were measured. Furthermore, to gain insights into the potential mechanisms underlying the protective effects of QDG against hypertension-induced cardiac injury, a network pharmacology study was conducted. Predicted results were validated by Western blot, radioimmunoassay immunohistochemistry and quantitative polymerase chain reaction, respectively.
RESULTS:
The administration of QDG resulted in a significant decrease in blood pressure levels in SHRs (P<0.01). Histological examinations, including hematoxylin-eosin staining and Masson trichrome staining revealed that QDG effectively attenuated hypertension-induced cardiac damage. Furthermore, echocardiography demonstrated that QDG improved hypertension-associated cardiac dysfunction. Enzyme-linked immunosorbent assay and colorimetric method indicated that QDG significantly reduced oxidative stress and inflammatory response levels in both myocardial tissue and serum (P<0.01).
CONCLUSIONS
Both network pharmacology and experimental investigations confirmed that QDG exerted its beneficial effects in decreasing hypertension-induced cardiac damage by regulating the angiotensin converting enzyme (ACE)/angiotensin II (Ang II)/Ang II receptor type 1 axis and ACE/Ang II/Ang II receptor type 2 axis.
Animals
;
Drugs, Chinese Herbal/therapeutic use*
;
Hypertension/pathology*
;
Renin-Angiotensin System/drug effects*
;
Rats, Inbred SHR
;
Oxidative Stress/drug effects*
;
Male
;
Rats, Inbred WKY
;
Blood Pressure/drug effects*
;
Myocardium/pathology*
;
Rats
;
Inflammation/pathology*
9.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*
10.Determination of Anlotinib in Human Plasma by UPLC-MS/MS and Its Clinical Application
Jiang LOU ; Hong JIANG ; Junjie LAO ; Ling CHEN ; Cheng YI ; Xinmei WU ; Jing WANG ; Gang WANG
Chinese Journal of Modern Applied Pharmacy 2024;41(11):1515-1523
OBJECTIVE
To establish a ultra-high-performance liquid chromatography-mass spectrum/mass spectrum(UPLC-MS/MS) method for the determination of anlotinib in human plasma and assessment of clinical application.
METHODS
Zanubrutinib was used as internal standard and the extraction process was performed through protein precipitation method using acetonitrile, followed by separation on an Ultimate XB-C18(100 mm×2.1 mm, 3.0 μm) column using acetonitrile and 10 mmol·L−1 ammonium acetate-0.1% formic acid step-elution gradient. The flow rate was 0.6 mL·min−1 and injection volume was 5 μL. The mass analysis was performed by positive ion electrospray ionization in multiple-reaction monitoring mode, and the mass spectrometer was set at m/z 408.1→339.1 for anlotinib and m/z 472.2→290.1 for internal standard, respectively. The specificity, standard curve and lower limit of quantification, precision and recovery, matrix effect and stability of the method and clinical application were investigated.
RESULTS
The method was validated over the concentration range of 1.0−100.0 ng·mL−1, with R2=0.998 4. The precision RSD was<9%, the recovery and matrix effect were 104.81%−107.32% and 102.54%−105.26%, respectively, and this method had good stability and was not affected by matrix effect. The method had been used for determined 52 advanced non-small cell lung cancer patients treated with anlotinib. The trough plasma concentration (Ctrough) was measured on day 43 after initiation of anlotinib treatment. Anlotinib Ctrough were higher than lower limit of quantitation (1.0 ng·mL−1) from 52 patients. The plasma concentration of anlotinib Ctrough was (11.38±4.29)ng·mL−1 with 37.66% coefficients of variation, which were shown large inter-patient variability.
CONCLUSION
This method is high sensitivity, specificity and accurate, and suitable for determination of anlotinib in human plasma.


Result Analysis
Print
Save
E-mail