1.Comparative Study on Effect of Jingui Shenqiwan and Liuwei Dihuangwan on Reproductive Ability and Brain Function of Normal Mice
Hong SUN ; Fan LEI ; Chenggong LI ; Rui LUO ; Shixian HU ; Bin REN ; Juan HAO ; Yi DING ; Lijun DU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(2):1-14
ObjectiveTo explore the effects of Jingui Shenqiwan (JSW) and Liuwei Dihuangwan (LDW) on the reproductive ability and brain function of normal mice and compare the actions of the two medications. MethodsSeven groups of female and male mice were divided at a ratio of 2∶1. Except for the control group, the other six groups were as follows: a group of both males and females receiving JSW (3.0 g·kg-1), a group of both males and females receiving LDW (4.5 g·kg-1), a group of males receiving water and females receiving JSW, a group of males receiving water while females receiving LDW, a group of females receiving water while males receiving JSW, and a group of females receiving water while males receiving LDW. Each group was administered the drug for 14 days and then caged together at a 2∶1 (female∶male) ratio to detect the number of pregnant mice and calculate the pregnancy rate. Pregnant mice continued receiving the drug until they naturally gave birth, which was followed by the observation of newborn mice, calculation of their average number, and the measurement of the offspring's preference for sugar water and neonatal recognition index. At the end of the experiment, the weights of the thymus and spleen were measured to calculate the organ coefficients, and mRNA or protein expression was analyzed in the brain and testes or ovaries. A 1% sucrose solution was used to examine the euphoria of their brain reward systems, while novel object recognition test (NOR) was applied to assess their memory capabilities. mRNA expression was detected using real-time quantitative polymerase chain reaction (Real-time PCR) assay, and protein expression was analyzed with Western blot. ResultsCompared with the control group, oral administration of JSW to both male and female mice for 14 days significantly increased the pregnancy rate of female mice on day 2 after being caged together (P<0.05), while LDW showed a trend but no statistical significance. Additionally, compared with the control group, JSW could upregulate the gene expression of gonadotropin-releasing hormone (GnRH) in the thalamus, as well as reproductive stem cell factor (SCF) and tyrosine kinase receptor (c-Kit) in the testes and reproductive stem cell marker mouse vasa homologue (MVH) in the ovaries, upregulate the expression of proteins influencing neuronal functional activity, such as brain-derived neurotrophic factor (BDNF), in hippocampal neurons (P<0.05), and enhance sucrose preference in male mice (P<0.05). Compared with the control group, JSW significantly increased sucrose preference and novel object recognition index in offspring mice (P<0.05), which was related to the upregulation of hippocampal dopamine D1 receptor (D1R) and N-methyl-D-aspartate receptor (Nmdar) gene expression. Compared with the control group, both JSW and LDW could upregulate the protein expression of glucocorticoid receptor (GR), BDNF, and tyrosine kinase receptor B (TrkB) in the hippocampus of offspring mice (P<0.05). ConclusionJSW significantly enhances the reproductive ability of normal mice, which is not only related to the release of gonadotropin but also associated with its regulation of brain function. Additionally, JSW has a certain regulatory effect on the brain function of the offspring mice.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Research and application implementation of the Internet of Things scheme for intensive care unit medical equipment.
Hong LIANG ; Jipeng SUN ; Yong FAN ; Desen CAO ; Kunlun HE ; Zhengbo ZHANG ; Zhi MAO
Journal of Biomedical Engineering 2025;42(1):65-72
The intensive care unit (ICU) is a highly equipment-intensive area with a wide variety of medical devices, and the accuracy and timeliness of medical equipment data collection are highly demanded. The integration of the Internet of Things (IoT) into ICU medical devices is of great significance for enhancing the quality of medical care and nursing, as well as for the advancement of digital and intelligent ICUs. This study focuses on the construction of the IOT for ICU medical devices and proposes innovative solutions, including the overall architecture design, devices connection, data collection, data standardization, platform construction and application implementation. The overall architecture was designed according to the perception layer, network layer, platform layer and application layer; three modes of device connection and data acquisition were proposed; data standardization based on Integrating the Healthcare Enterprise-Patient Care Device (IHE-PCD) was proposed. This study was practically verified in the Chinese People's Liberation Army General Hospital, a total of 122 devices in four ICU wards were connected to the IoT, storing 21.76 billion data items, with a data volume of 12.5 TB, which solved the problem of difficult systematic medical equipment data collection and data integration in ICUs. The remarkable results achieved proved the feasibility and reliability of this study. The research results of this paper provide a solution reference for the construction of hospital ICU IoT, offer more abundant data for medical big data analysis research, which can support the improvement of ICU medical services and promote the development of ICU to digitalization and intelligence.
Intensive Care Units
;
Internet of Things
;
Humans
;
Internet
;
Data Collection
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Effect of Shenge Bushen Capsules and Its Polysaccharides and Flavonoids on Precocious Puberty in Young Mice
Hong SUN ; Fan LEI ; Chenggong LI ; Shixian HU ; Weihua WANG ; Bin REN ; Juan HAO ; Rui LUO ; Lijun DU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(1):95-103
ObjectiveTo explore the effect of Shenge Bushen Capsules (SBC) on sexual development in normal 3-week-old mice. MethodsThe experiment consisted of two parts. In the first part, mice were divided into four groups: The control group and the low, medium, and high-dose SBC groups (234.7, 469.4, 938.7 mg·kg-1, respectively). In the second part, mice were divided into four groups: Control group, Pseudostellariae Radix polysaccharide (PRP) group, total flavonoids group, and SBC group, all receiving a dose of 469.4 mg·kg-1. After 7 days of administration, the vaginal opening of female mice and the descent of testes and scrotum in male mice, as well as the ovarian and testicular organ indices, were observed. After 4 weeks of administration, female and male mice were housed together for 2 days, and the pregnancy rate of females was monitored. After delivery, the pregnant female mice continued receiving the treatment for 4 weeks, and the sexual development of their offspring, including vaginal opening, testicular descent, and organ indices of ovaries and testes, was observed. Serum sex hormones were measured by enzyme-linked immunosorbent assay (ELISA), and the expression of gonadotropin-releasing hormone (GnRH) and growth hormone (GH) proteins in the hypothalamus was assessed by Western blot. ResultsCompared with the control group, there was no significant effect on the vaginal opening of female mice or the descent of testes in male mice after 7 days of SBC administration. After 4 weeks of administration, the pregnancy rate in the low-dose group was significantly reduced (P<0.05), but no significant effects were observed in the other groups. The three doses of SBC did not significantly affect the ovarian or testicular organ indices, and there was no significant upregulation in the expression of GnRH or GH in the hypothalamus. The primary component of SBC, Pseudostellariae Radix polysaccharide, significantly reduced the vaginal opening in female mice after 7 days of administration (P<0.05). After 4 weeks, the serum estradiol levels of non-pregnant female mice were decreased (P<0.05), but there was no significant effect on the expression of GnRH or GH proteins in the hypothalamus of either male or female mice. Additionally, there were no significant effects on precocious puberty indicators, such as vaginal opening and testicular descent, in the offspring mice. ConclusionSBC does not significantly promote precocious puberty in young mice, and it does not have any noticeable effects on the pregnancy rate of adult mice or the sexual development of their offspring.
8.Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture-dislocation in adults (version 2025)
Qingde WANG ; Tongwei CHU ; Jian DONG ; Liangjie DU ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Yong HAI ; Da HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Fang LI ; Feng LI ; Li LI ; Weishi LI ; Fangcai LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Xuhua LU ; Keya MAO ; Xuexiao MA ; Yong QIU ; Limin RONG ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Bing WANG ; Linfeng WANG ; Yu WANG ; Qinghe WANG ; Jigong WU ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Yong YANG ; Qiang YANG ; Cao YANG ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Zezhang ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Yan ZENG ; Dingjun HAO ; Baorong HE ; Wei MEI
Chinese Journal of Trauma 2025;41(3):243-252
Cervical spinal cord injury without fracture-dislocation (CSCIWFD) is referred to as a special type of cervical spinal cord injury characterized by traumatic spinal cord dysfunction and no significant bony structural abnormalities on imagines. Duo to the high risk of missed diagnosis during the initial consultation, CSCIWFD may lead to progressive neurological deterioration or even complete paralysis, severely impacting patients′ prognosis. Currently, there are no established consensuses over the diagnosis and treatment of CSCIWFD, such as the lack of evidence-based standards for indications of non-surgical treatment and risk of secondary neurological injury, as well as debates over the optimal timing for surgical intervention and indications for different surgical approaches. To address these issues, the Spine Trauma Group of the Orthopedic Branch of the Chinese Medical Doctor Association organized experts in the relevant fields to formulate Diagnosis and treatment guideline for acute cervical spinal cord injury without fracture- dislocation in adults ( version 2025) . Based on evidence-based medicine and the principles of scientific rigor and clinical applicability, the guidelines proposed 11 recommendations covering terminology, diagnosis, evaluation treatment, and rehabilitation, etc., aiming to standardize the management of CSCIWFD.
9.Expert consensus on intraoperative repositioning for patients with spine fracture and dislocation (version 2025)
Dongmei BIAN ; Ke SUN ; Ningbo CHEN ; Caixia BAI ; Miao WANG ; Yafeng QIAO ; Fei WANG ; Hong WANG ; Feng TIAN ; Mei YAN ; Meng BAI ; Linjuan ZHANG ; Liyan ZHAO ; Yaqing CUI ; Xue JIANG ; Leling FENG ; Ning NING ; Junqin DING ; Lan WEI ; Yonghua ZHAI ; Yu ZENG ; Zengmei ZHANG ; Jiqun HE ; Fenggui BIE ; Hong CHEN ; Zengyan WANG ; Li LI ; Li ZHANG ; Yaying ZHOU ; Bing SHAO ; Ying WANG ; Caixia XIE ; Yanfeng YAO ; Jingjing AN ; Wen SHI ; Xiongtao LIU ; Xiaoyan AN ; Ning NAN ; Lan LI ; Xiaohui GOU ; Qiaomei LI ; Xiuting WU ; Yuqin ZHANG ; Jing LIU ; Fusen XIANG ; Xu XU ; Na MEI ; Jiao ZHOU ; Shan FAN ; Qian WANG ; Shuixia LI
Chinese Journal of Trauma 2025;41(2):138-147
Spine fracture and dislocation are common traumatic spinal conditions that often require surgical intervention due to compromised spinal stability. Surgical approaches include anterior, posterior, and combined anterior-posterior spinal procedures. According to the specific surgical requirements, patients may be placed in the prone position or repositioned between prone and supine positions during surgery. Intraoperative repositioning has become an essential step in patient positioning. However, during repositioning, patients with spinal fracture and dislocation are at increased risk for complications such as hemodynamic instability, nerve injury, and pressure injuries to the skin and soft tissue. Notably, due to the instability of the spinal cord, even minor manipulations can further exacerbate the damage, potentially leading to severe outcomes like paraplegia. Although the current clinical guidelines provide instructive recommendations for standard position, there remains no specific protocols for intraoperative repositioning in patients with spine fracture and dislocation. With a concern for the lack of clinical studies on positioning techniques, risk prevention, and operational norms for special patients, no applicable guidelines or standards are available. A consensus was required to provide clinical reference, meet the requirements of surgical treatment, and minimize the safety risks of patients caused by improper placement of positions. Professional Committee of Operating Room Nursing of Shaanxi Nursing Association organized experts in nursing management and operating room nursing from major hospitals across China to formulate Expert consensus on intraoperative repositioning for patients with spinal fracture and dislocation ( version 2025). The consensus provides 11 recommendations covering pre-repositioning preparation, intraoperative maneuvers, and post-repositioning observation, aiming to provide references for clinical standardization of the intraoperative repositioning process and protection of patients′ safety.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail