1.Engineered Bacteriophages for The Treatment of Multidrug-resistant Bacterial Infections
Yu-Ying CHEN ; Chun-Mei HUANG ; Jin-Zhi PAN ; De-Liang LIU ; Yang ZHOU ; Gui-Qin DAI ; Peng-Fei ZHAO ; Hong-Zhou LU ; Ming-Bin ZHENG
Progress in Biochemistry and Biophysics 2026;53(6):1581-1596
Multidrug-resistant (MDR) bacterial infections have emerged as a serious challenge of global public health crisis. The overuse and misuse of conventional antibiotics have dramatically accelerated the emergence, evolution and worldwide spread of drug-resistant bacterial strains, necessitating urgent exploration of novel antibacterial strategies. Bacteriophages serve as natural bacterial predators offering distinct advantages including high host specificity, autonomous self-replication capabilities and cost-effective large-scale production. However, wild-type phages present significant clinical limitations due to their narrow host ranges, susceptibility to rapid immune clearance and poor penetration of bacterial biofilms, which severely restrict their therapeutic applications. The convergence of synthetic biology, nanotechnology and advanced gene editing technologies has accelerated the development of engineered bacteriophage platforms, providing programmable, scalable and clinically translatable pathways to overcome these inherent biological constraints. Here, we systematically delineate four fundamental strategies for engineered bacteriophage development. Chemical modification utilizes reactive functional groups such as amino, carboxyl and thiol moieties on capsid proteins through esterification, amidation or click chemistry reactions to achieve precise drug conjugation and surface functionalization. In vivo editing encompasses ultraviolet or chemical mutagenesis for random mutation induction, homologous recombination for targeted genetic alterations, recombineering methodologies including electroporation-mediated bacteriophage recombination engineering, and CRISPR-Cas systems for precise genome editing to enable exact genetic reconstruction and host range reprogramming. In vitro synthesis leverages genome engineering platforms where intact phage genomes are transferred into yeast or host bacteria to facilitate highly efficient homologous recombination, enabling large DNA fragment assembly and cross-gene host range expansion without bacterial toxicity constraints. Directed evolution combines artificial selection through mutation library screening with rational design approaches involving chimeric receptor binding protein construction or site-specific mutagenesis, effectively balancing the discovery of unknown adaptive pathways with targeted host specificity modification. Moreover, we comprehensively discuss therapeutic applications across diverse clinical scenarios. Engineered bacteriophage effectively disrupt bacterial biofilms through sophisticated functionalized delivery platforms including nanozyme-conjugated phages, phage-liposome nanoconjugates and bio-responsive hydrogels, demonstrating significantly enhanced bactericidal efficiency compared to unmodified free phages. These bioengineered vectors attenuate bacterial virulence and resensitize pathogens to antibiotics by delivering CRISPR-Cas systems or base editors to disrupt critical virulence factors such as pili, capsule synthesis machineries and quorum sensing systems, or by inactivating antibiotic resistance determinants including beta-lactamase genes. As an intelligent nanomedicine delivery platform, engineered bacteriophage enable precise pathogen elimination an through photocatalytic reactive oxygen species generation, immunomodulatory interventions, or controlled release of antibacterial drugs. Furthermore, oral administration of engineered bacteriophage facilitates microbiota modulation, which selectively eliminate intestinal pathogens while preserve beneficial commensal microbiota, thereby restoring microbial community balance and preventing complications associated with dysbiosis. Finally, we critically analyze persistent challenges including host strain matching complexity, evolution of bacterial resistance mechanisms, pharmacokinetic optimization requirements, optimal administration route selection, large-scale production quality control standards and clinical dosing determination protocols. Through multidisciplinary integration of synthetic biology, infectious disease medicine and immunology, future translational medicine studies of bacteriophage should establish comprehensive technical platforms encompassing rapid phage screening, intelligent rational design, rigorous in vivo evaluation and standardized clinical validation processes, ultimately advancing engineered bacteriophage from laboratory innovations to clinically approved therapeutics for effectively combating MDR bacterial infections.
2.Clinical Application of Multimodal MRI in Cognitive Impairment Associated with Cerebral Small Vessel Disease
Hong XU ; Mao-hua HUANG ; Quan-zhi ZHAO ; Meng-pan HUANG ; Bao LIAO
Progress in Modern Biomedicine 2025;25(17):2820-2826
Objective:To explore the clinical application value of multimodal Magnetic Resonance Imaging(MRI)in cognitive impairment related to Cerebral Small Vessel Disease(CSVD).Methods:This study was a retrospective analysis of 60 CSVD patients,who were divided into cognitive impairment group(n=32)and normal group(n=28)based on Montreal Cognitive Assessment scale(MoCA).Compare the general information and MRI parameters of two groups of patients,use correlation analysis and logistic regression analysis to investigate the relationship between MRI parameters and cognitive dysfunction,and use receiver operating characteristic curve(ROC)to explore the value of MRI parameters in diagnosing cognitive dysfunction in cerebral small vessel disease.Results:Compared with the cognitively normal group,the cognitive impairment group had older age,higher apparent diffusion coefficient(ADC),lower anisotropy score(FA),and an overall increase in microbleeds(P<0.05).Age(r=-0.510),ADC value(r=-0.591),and overall number of microbleeds(r=-0.369)were significantly negatively correlated with MoCA score(P<0.05),while FA value(r=0.262)was significantly positively correlated with MoCA score(P<0.05).The logistic regression results indicate that age,overall microbleeds,ADC value,and FA value are influencing factors for cognitive impairment in patients with cerebral small vessel disease.ROC curve analysis showed that the combination of age,ADC,FA,and microbleeds significantly improved diagnostic efficacy(AUC=0.990,95%CI=0.974-1.000).Conclusion:The joint analysis of multimodal MRI parameters can provide important imaging evidence for the early identification of cognitive dysfunction in CSVD.
3.Clinical Application of Multimodal MRI in Cognitive Impairment Associated with Cerebral Small Vessel Disease
Hong XU ; Mao-hua HUANG ; Quan-zhi ZHAO ; Meng-pan HUANG ; Bao LIAO
Progress in Modern Biomedicine 2025;25(17):2820-2826
Objective:To explore the clinical application value of multimodal Magnetic Resonance Imaging(MRI)in cognitive impairment related to Cerebral Small Vessel Disease(CSVD).Methods:This study was a retrospective analysis of 60 CSVD patients,who were divided into cognitive impairment group(n=32)and normal group(n=28)based on Montreal Cognitive Assessment scale(MoCA).Compare the general information and MRI parameters of two groups of patients,use correlation analysis and logistic regression analysis to investigate the relationship between MRI parameters and cognitive dysfunction,and use receiver operating characteristic curve(ROC)to explore the value of MRI parameters in diagnosing cognitive dysfunction in cerebral small vessel disease.Results:Compared with the cognitively normal group,the cognitive impairment group had older age,higher apparent diffusion coefficient(ADC),lower anisotropy score(FA),and an overall increase in microbleeds(P<0.05).Age(r=-0.510),ADC value(r=-0.591),and overall number of microbleeds(r=-0.369)were significantly negatively correlated with MoCA score(P<0.05),while FA value(r=0.262)was significantly positively correlated with MoCA score(P<0.05).The logistic regression results indicate that age,overall microbleeds,ADC value,and FA value are influencing factors for cognitive impairment in patients with cerebral small vessel disease.ROC curve analysis showed that the combination of age,ADC,FA,and microbleeds significantly improved diagnostic efficacy(AUC=0.990,95%CI=0.974-1.000).Conclusion:The joint analysis of multimodal MRI parameters can provide important imaging evidence for the early identification of cognitive dysfunction in CSVD.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Histaminergic Innervation of the Ventral Anterior Thalamic Nucleus Alleviates Motor Deficits in a 6-OHDA-Induced Rat Model of Parkinson's Disease.
Han-Ting XU ; Xiao-Ya XI ; Shuang ZHOU ; Yun-Yong XIE ; Zhi-San CUI ; Bei-Bei ZHANG ; Shu-Tao XIE ; Hong-Zhao LI ; Qi-Peng ZHANG ; Yang PAN ; Xiao-Yang ZHANG ; Jing-Ning ZHU
Neuroscience Bulletin 2025;41(4):551-568
The ventral anterior (VA) nucleus of the thalamus is a major target of the basal ganglia and is closely associated with the pathogenesis of Parkinson's disease (PD). Notably, the VA receives direct innervation from the hypothalamic histaminergic system. However, its role in PD remains unknown. Here, we assessed the contribution of histamine to VA neuronal activity and PD motor deficits. Functional magnetic resonance imaging showed reduced VA activity in PD patients. Optogenetic activation of VA neurons or histaminergic afferents significantly alleviated motor deficits in 6-OHDA-induced PD rats. Furthermore, histamine excited VA neurons via H1 and H2 receptors and their coupled hyperpolarization-activated cyclic nucleotide-gated channels, inward-rectifier K+ channels, or Ca2+-activated K+ channels. These results demonstrate that histaminergic afferents actively compensate for Parkinsonian motor deficits by biasing VA activity. These findings suggest that targeting VA histamine receptors and downstream ion channels may be a potential therapeutic strategy for PD motor dysfunction.
Animals
;
Histamine/metabolism*
;
Male
;
Oxidopamine/toxicity*
;
Rats
;
Ventral Thalamic Nuclei/physiopathology*
;
Rats, Sprague-Dawley
;
Disease Models, Animal
;
Parkinson Disease/metabolism*
;
Neurons/physiology*
;
Humans
;
Optogenetics
10.Expert consensus on management of instrument separation in root canal therapy.
Yi FAN ; Yuan GAO ; Xiangzhu WANG ; Bing FAN ; Zhi CHEN ; Qing YU ; Ming XUE ; Xiaoyan WANG ; Zhengwei HUANG ; Deqin YANG ; Zhengmei LIN ; Yihuai PAN ; Jin ZHAO ; Jinhua YU ; Zhuo CHEN ; Sijing XIE ; He YUAN ; Kehua QUE ; Shuang PAN ; Xiaojing HUANG ; Jun LUO ; Xiuping MENG ; Jin ZHANG ; Yi DU ; Lei ZHANG ; Hong LI ; Wenxia CHEN ; Jiayuan WU ; Xin XU ; Jing ZOU ; Jiyao LI ; Dingming HUANG ; Lei CHENG ; Tiemei WANG ; Benxiang HOU ; Xuedong ZHOU
International Journal of Oral Science 2025;17(1):46-46
Instrument separation is a critical complication during root canal therapy, impacting treatment success and long-term tooth preservation. The etiology of instrument separation is multifactorial, involving the intricate anatomy of the root canal system, instrument-related factors, and instrumentation techniques. Instrument separation can hinder thorough cleaning, shaping, and obturation of the root canal, posing challenges to successful treatment outcomes. Although retrieval of separated instrument is often feasible, it carries risks including perforation, excessive removal of tooth structure and root fractures. Effective management of separated instruments requires a comprehensive understanding of the contributing factors, meticulous preoperative assessment, and precise evaluation of the retrieval difficulty. The application of appropriate retrieval techniques is essential to minimize complications and optimize clinical outcomes. The current manuscript provides a framework for understanding the causes, risk factors, and clinical management principles of instrument separation. By integrating effective strategies, endodontists can enhance decision-making, improve endodontic treatment success and ensure the preservation of natural dentition.
Humans
;
Root Canal Therapy/adverse effects*
;
Consensus
;
Root Canal Preparation/adverse effects*

Result Analysis
Print
Save
E-mail