1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Junctophilin-2 MORN-Helix Domain: Structural Basis for Membrane Binding and Hypertrophic Cardiomyopathy-associated Mutations
Jing-Xin WANG ; Zhi-Wei LI ; Wei LIU ; Wen-Qing ZHANG ; Jian-Chao LI
Progress in Biochemistry and Biophysics 2025;52(8):2103-2116
ObjectiveJunctophilin-2 (JPH2) is an essential structural protein that maintains junctional membrane complexes (JMCs) in cardiomyocytes by tethering the plasma membrane to the sarcoplasmic reticulum, thereby facilitating excitation-contraction (E-C) coupling. Mutations in JPH2 have been associated with hypertrophic cardiomyopathy (HCM), but the molecular mechanisms governing its membrane-binding properties and the functional relevance of its membrane occupation and recognition nexus (MORN) repeat motifs remain incompletely understood. This study aimed to elucidate the structural basis of JPH2 membrane association and its implications for HCM pathogenesis. MethodsA recombinant N-terminal fragment of mouse JPH2 (residues1-440), encompassing the MORN repeats and an adjacent helical region, was purified under near-physiological buffer conditions.X-ray crystallography was employed to determine the structure of the JPH2 MORN-Helix domain. Sequence conservation analysis across species and junctophilin isoforms was performed to assess the evolutionary conservation of key structural features. Functional membrane-binding assays were conducted using liposome co-sedimentation and cell-based localization studies in COS7 and HeLa cells. In addition, site-directed mutagenesis targeting positively charged residues and known HCM-associated mutations, including R347C, was used to evaluate their effects on membrane interaction and subcellular localization. ResultsThe crystal structure of the mouse JPH2 MORN-Helix domain was resolved at 2.6 Å, revealing a compact, elongated architecture consisting of multiple tandem MORN motifs arranged in a curved configuration, forming a continuous hydrophobic core stabilized by alternating aromatic residues. A C-terminal α-helix further reinforced structural integrity. Conservation analysis identified the inner groove of the MORN array as a highly conserved surface, suggesting its role as a protein-binding interface. A flexible linker segment enriched in positively charged residues, located adjacent to the MORN motifs, was found to mediate direct electrostatic interactions with negatively charged phospholipid membranes. Functional assays demonstrated that mutation of these basic residues impaired membrane association, while the HCM-linked R347C mutation completely abolished membrane localization in cellular assays, despite preserving the overall MORN-Helix fold in structural modeling. ConclusionThis study provides structural insight into the membrane-binding mechanism of the cardiomyocyte-specific protein JPH2, highlighting the dual roles of its MORN-Helix domain in membrane anchoring and protein interactions. The findings clarify the structural basis for membrane targeting via a positively charged linker and demonstrate that disruption of this interaction—such as that caused by the R347C mutation—likely contributes to HCM pathogenesis. These results not only enhance current understanding of JPH2 function in cardiac E-C coupling but also offer a structural framework for future investigations into the assembly and regulation of JMCs in both physiological and disease contexts.
7.Study on HPLC fingerprint and quantitative analysis of multi-components by single-marker content determination method for Shechuan naolitong granules
Xiaoyan ZHANG ; Kairu DING ; Hong ZHANG ; Wenbing ZHI ; Shengnan JIANG ; Zongren XU ; Ni CUI ; Xiangfeng WEI ; Yang LIU
China Pharmacy 2025;36(19):2409-2414
OBJECTIVE To provide a reference for optimizing and promoting the quality standards of Shechuan naolitong granules. METHODS Fifteen batches of Shechuan naolitong granules were used as samples to establish HPLC fingerprints using the Similarity Evaluation System for Chromatographic Fingerprint of Traditional Chinese Medicine (2012 edition). Similarity evaluation and common peak identification were performed, and orthogonal partial least squares discriminant analysis (OPLS-DA) was used to assess quality differences among different batches and to screen quality differential components. Using salvianolic acid B(SAB) as the internal reference, quantitative analysis of multi-components by single-marker (QAMS) was developed to simultaneously determine geniposidic acid (GA), chlorogenic acid (CA), vaccarin (VA), ferulic acid (FA) and senkyunolide I (SI). The results were compared with those obtained by the external standard method. RESULTS A total of 13 common peaks were identified in the HPLC fingerprints of 15 batches of samples, and the similarities of the spectra were all above 0.96. Seven chromatographic peaks were identified as GA (peak 3), CA (peak 6), VA (peak 8), FA (peak 9), SI (peak 11), SAB(peak 12) and TA(peak 13). OPLS-DA indicated that the differential quality markers among 15 batches were peaks 5, 11 (SI), and 12 (SAB).Using SAB as the internal reference, the relative correction factors for GA, CA, VA, FA and SI were calculated as 1.058 4, 0.594 3, 0.643 3, 0.342 7 and 0.262 8, respectively. The mean content of GA, CA, VA, FA, SI and SAB across the 15 batches of samples were 0.155 0, 0.085 4, 0.140 3, 0.071 8, 0.072 7, 1.276 3 mg/g, respectively, showing no significant difference compared with the ESM (P>0.05). CONCLUSIONS The established HPLC fingerprint and QAMS are simple, efficient and economical, providing a reference for the quality control and further development of Shechuan naolitong granules.
8.Ginkgo biloba extract activates Nrf2/ARE pathway to improve vascular endothelial dysfunction induced by chronic intermittent hypoxia in rats
Sheng-Yong SI ; Hong-Man LI ; Si-Si MIAO ; Xiao HAN ; Zhi-Jing LI ; Chao-Jun WEI ; Da-Nan LIU
Chinese Pharmacological Bulletin 2024;40(10):1837-1844
Aim To investigate the effects of Ginkgo biloba extract(GBE)on vascular endothelial dysfunc-tion induced by chronic intermittent hypoxia(CIH)in rats and its related mechanisms.Methods The CIH rat model was established,and 50 and 100 mg·kg-1 GBE was administered by intragastric administration.The systolic blood pressure(SBP)of the tail artery was detected in each group.HE staining was used to detect the morphology of aorta tissue.DAF-FM DA staining and nitric reductase assay were used to detect NO levels.ELISA was used to detect serum ET-1,TNF-α and IL-6 levels.DHE staining was used to de-tect reactive oxygen species(ROS)levels of aortic tis-sue.Kits were used to detect the serum levels of MDA,SOD and GSH-Px.Western blot was used to detect the levels of VCAM-1,ICAM-1,nucleus Nrf2,HO-1 and NQO1 of aortic tissue.Results GBE sig-nificantly decreased the levels of SBP,ET-1,ROS,MDA,VCAM-1,ICAM-1,TNF-α and IL-6,and sig-nificantly increased the levels of NO,SOD,GSH-Px,nuclear Nrf2,HO-1 and NQO1 in CIH rats.GBE sig-nificantly improved the histomorphology of aorta in CIH rats.Conclusions GBE can improve vascular endo-thelial dysfunction and reduce blood pressure in CIH model rats.The mechanism may be related to the acti-vation of Nrf2/ARE pathway and the inhibition of oxi-dative stress and inflammation by GBE.
9.Hydrogen sulfide and neuroinflammation-mediated neurodegenerative diseases
Yu-Lian SHUI ; Zhi-Qiong REN ; Yi-Jie HE ; Bin-Bin CHEN ; Jia HONG ; Ke-Ting LIU ; Li XIAO
Journal of Regional Anatomy and Operative Surgery 2024;33(6):551-554
Hydrogen sulfide,as a third gas signal molecule and neurotransmitter,can play a neuroprotective role by anti-oxidative stress,anti-inflammatory response,metabolic inhibition and other mechanisms.It is of great significance for the occurrence and development of neurodegenerative diseases including Alzheimer's disease(AD)and Parkinson's disease(PD)mediated by neuroinflammation.This article reviews the research progress of hydrogen sulfide and neuroinflammation and its mediated neurodegenerative diseases,so as to provide new ideas for the treatment of neurodegenerative diseases.
10.Diagnostic value of 62-slice spiral CT and its post-processing techniques for tibial plateau fracture and its classification
Xiu LIU ; Shuang JIA ; Zhi-Jiao ZHOU ; Yang YANG ; Wei LUO ; Hong-Jie TANG
Journal of Regional Anatomy and Operative Surgery 2024;33(11):995-998
Objective To investigate the diagnostic value of 62-slice spiral CT and its post-processing techniques for tibial plateau fracture(TPF)and its influence on treatment regimens selection.Methods A total of 173 TPF patients diagnosed and treated in our hospital from January 2021 to December 2022 were included,and the diagnostic accuracy,classification diagostic accuracy and fracture collapse degree accuracy of X-ray and CT scans were compared,with surgical and pathological diagnosis as the gold standard.Results CT and its post-processing technique can more clearly show the direction of fracture line,the displacement direction of fracture fragments and the collapse degree of articular surface than X-ray.The fracture morphology of 171 patients seen during the operation was consistent with CT and its post-processing images.The diagnostic accuracy of X-ray for TPF was 93.64%,which was lower than that of CT and its post-processing techniques(98.84% ),and the difference was statistically significant(χ2=6.474,P=0.011).The overall accuracy of X-ray in evaluating the degree of fracture collapse was significantly lower than that of CT 3D reconstruction(65.32% vs.90.75%;χ2=32.644,P<0.001).The total accuracy of CT and its post-processing techniques for TPF Schatzker classification(97.69% )was higher than that of X-ray(88.44% ),and the difference was statistically significant(χ2=11.462,P=0.001).Different CT reconstruction models had statistically significant difference on the total accuracy of TPF Schatzker classification diagnosis(χ2=40.647,P<0.001),and the diagnosis accuracy of volume reconstruction was the highest(96.53% ).Conclusion The application of CT and its post-processing techniques can effectively evaluate TPF,articular surface collapse and fracture classification,and provide imaging reference for clinical decision-making.

Result Analysis
Print
Save
E-mail