1.Combination Therapy with Betulinic Acid and TRAIL Increases ROS-Dependent Cytotoxicity and Inhibits PI3K/Akt Signaling in Human Bladder Cancer Cells
Cheol PARK ; Hee-Jae CHA ; Su Hyun HONG ; Heui-Soo KIM ; Sun-Hee LEEM ; Jung-Hyun SHIM ; Gi-Young KIM ; Kyoung Ah KANG ; Jin Won HYUN ; Yung Hyun CHOI
Biomolecules & Therapeutics 2026;34(3):641-651
Tumor necrosis factor-related apoptosis-inducing ligand (TRAIL) is a cytokine that selectively targets cancer cells and induces apoptosis. However, many cancers, including bladder cancer, develop resistance to TRAIL, limiting the efficacy of TRAIL-based therapies. This study investigated whether betulinic acid (BA), a pentacyclic triterpenoid with anticancer and chemosensitizing properties, increases TRAIL-mediated apoptosis in TRAIL-resistant human bladder cancer cells. Combination treatment with BA and TRAIL significantly increased cytotoxicity and apoptosis compared to either treatment alone. This combination treatment also increased reactive oxygen species (ROS) production, increased Bax expression and Bid cleavage (tBid formation), and downregulated Bcl-2 levels. These effects were accompanied by caspase activation via extrinsic and intrinsic pathways, leading to cytochrome c release via mitochondrial membrane destabilization, thereby contributing to increased apoptosis. Furthermore, the combination treatment inhibited phosphoinositide 3-kinase (PI3K) and Akt phosphorylation; this effect was amplified by a PI3K inhibitor but abrogated by ROS inhibition. Collectively, our results suggest that BA sensitizes bladder cancer cells to TRAILinduced apoptosis via ROS-dependent activation of the apoptotic pathway and inhibition of PI3K/Akt signaling. Therefore, the BA and TRAIL combination exhibits potential to overcome TRAIL resistance in human bladder cancer.
2.Stress Accelerates Depressive-Like Behaviors through Increase of Notch2 Expression in N141I Mutation Presenilin-2 Transgenic Mice
Seung Sik YOO ; Sun Mi GU ; Kyung Tak NAM ; Jeong Soon CHOI ; Yong Sun LEE ; In Jun YEO ; Ji Eun YU ; Sanghyeon KIM ; Dong Won LEE ; Hyeon Joo HAM ; Ju Young CHANG ; Jaesuk YUN ; Dong Ju SON ; Sang-Bae HAN ; Jin Tae HONG
Biomolecules & Therapeutics 2026;34(3):544-555
Alzheimer’s disease (AD) is characterized by progressive cognitive deterioration and significant depression. However, the mechanisms linking depression to AD pathology remain unclear. Here, we investigated whether Notch2 signaling mediates depressionlike behaviors in presenilin-2 (PS2) N141I mutant mice, an early-onset AD model. PS2 wild-type (WT) and mutant (MT) mice aged 12-15 months were subjected to unpredictable chronic mild stress (UCMS) for 4 weeks, followed by sucrose preference, tail-hanging, and forced swimming tests. Behavioral assessments showed that UCMS exacerbated anhedonia and immobility only in PS2 MT mice. Molecular analysis revealed concomitant increases in plasma corticosterone, hippocampal γ-secretase activity, and Notch2 expression, and elevated total and phosphorylated glucocorticoid receptor levels in PS2 MT-UCMS mice. Gene expression profiling of human hippocampal datasets confirmed upregulation of NOTCH2 in Alzheimer’s disease and depression.Pharmacological inhibition of γ-secretase and Notch signaling with DAPT normalizes depressive behavior, reduces corticosterone release, attenuates GR phosphorylation, and inhibits Notch2 signaling in PS2 MT mice. These findings identify Notch2 as a pivotal mediator linking chronic stress to molecular changes associated with depression and AD, and suggest that targeting Notch2 signaling may provide therapeutic benefits for comorbid mood and neurodegenerative disorders.
3.Effects of Prior Exercise Habits and Adherence on Cognitive Function, Physical Fitness, and Vascular Health in Older Adults: An Exploratory Exercise-Based Intervention Trial
Da Ae KIM ; Muncheong CHOI ; Buongo CHUN ; Kyunghwa SUN ; So Young MOON ; Hong-Sun SONG ; Sun Min LEE
Dementia and Neurocognitive Disorders 2026;25(1):54-68
Background:
and Purpose: Given the irreversible nature of dementia, this study examined the effects of a 20-week exercise-based dementia prevention program in community-dwelling older adults, focusing on prior exercise experience and program adherence.
Methods:
In this exploratory, non-randomized trial, 55 older adults (65–79 years) were allocated to an intervention (n=26) or control (n=29) group, and blinding was not feasible.The intervention comprised supervised rhythmic aerobic exercise with cognitive-motor components performed three times per week. Cognition was the primary outcome, and secondary outcomes included physical fitness, blood pressure, and blood biomarkers.Subgroup analyses classified participants by prior exercise experience and intervention exposure: G1 and G2 comprised control subgroups with no intervention exposure, whereas G3 and G4 comprised intervention-exposed subgroups stratified by adherence.
Results:
No significant group-by-time interactions were observed for cognitive outcomes.Participants with prior exercise experience and low adherence (G2) showed significant improvement on the Korean Mini-Mental State Examination (β=1.66, p=0.024) despite declines in physical fitness, whereas higher adherence in G3–G4 was associated with stable or favorable physical performance, with G4 showing a positive trend in the 30-second sit-tostand test. Systolic blood pressure decreased significantly in G2–G4.
Conclusions
Although overall cognitive gains were modest and not group specific, prior exercise experience and sustained adherence were associated with favorable changes in physical fitness and vascular outcomes, suggesting that tailored multicomponent exercise programs and long-term engagement may help promote cognitive health in older adults.
4.Exploring the Association Between Physical Fitness Components and Cognitive Function in Older Korean Adults: The SUPERBRAIN Exploratory Sub-study
Da Ae KIM ; Buongo CHUN ; Muncheong CHOI ; Kyunghwa SUN ; Jee Hyang JEONG ; Yoo Kyoung PARK ; Chang Hyung HONG ; Hae Ri NA ; Seong Hye CHOI ; So Young MOON ; Hong-sun SONG ; Sun Min LEE
Dementia and Neurocognitive Disorders 2026;25(1):13-24
Background:
and Purpose: Tailored physical exercise interventions have the potential to promote cognitive health in older adults and offer significant advantages for those more vulnerable to decline. The specific relationship between physical fitness and cognition among the elderly has not been clearly established. The purpose of this investigation was to assess the relationship between physical fitness and cognitive function in older Korean adults.
Methods:
Eighty-four community-dwelling older adults (mean age: 70.7±5.3 years; 81.0% female) completed a standardized physical fitness battery assessing handgrip strength, sit-and-reach, 30-second sit-to-stand, 2-minute stationary march, 3-m sit-walk-and-return, figure-8-walk, and T-wall response time. Cognitive function was evaluated using the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS). Descriptive statistics, partial correlation analyses, and stepwise multiple linear regression were conducted.
Results:
Slower T-wall response time was significantly correlated with lower RBANS total index, immediate memory, and delayed memory scores. In regression models, slower T-wall response time was independently associated with lower RBANS total index (β=−0.234, p=0.026) and delayed memory scores (β=−0.295, p=0.029). The regression model for immediate memory was not statistically significant overall; therefore, no predictive conclusion was drawn for this domain. Higher education showed a significant positive association with cognitive performance.
Conclusions
Coordination, as measured by T-wall response time, emerged as the only physical fitness component consistently associated with cognitive performance in older adults. Coordination-related fitness may be an important correlate of cognitive function in older adults and a promising target for future exercise interventions.
5.Structured Integration of an Artificial Intelligence-Based System for the Optical Diagnosis of Colorectal Polyps
Hae Yeon KANG ; Soonwhan KANG ; Goh Eun CHUNG ; Dong Hoon BAEK ; Hong Sub LEE ; Jinbae PARK ; Sun Young YANG ; Seon Hee LIM ; Ji Min CHOI ; Jung KIM ; Jung Ho BAE
Gut and Liver 2026;20(1):86-96
Background/Aims:
Recent advances in computer-aided diagnosis (CADx) systems have demonstrated expert-level accuracy in the optical diagnosis of colorectal polyps. High-confidence (HC) diagnoses have been defined as those made within 3 seconds without hesitation, and these systems have been shown to improve diagnostic accuracy. We aimed to evaluate the performance of endoscopists with varying levels of experience in diagnosing colorectal polyps with the assistance of a new CADx system applying the 3-second rule and without artificial intelligence assistance.
Methods:
In this multicenter ex vivo study, 35 endoscopists assessed 100 polyps (51 adenomas, 39 hyperplastic polyps, 10 sessile serrated lesions) using narrow-band imaging video clips on an online platform. Assessments consisted of individual endoscopist diagnosis and CADx-assisted diagnosis. HC assignments followed the 3-second rule in both phases. Performance metrics included HC accuracy, HC rate, and adherence to the Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) and Simple Optical Diagnosis Accuracy (SODA) thresholds.
Results:
HC diagnostic accuracy improved from 78.3% (95% confidence interval [CI], 76.6% to 80.0%) to 89.8% (95% CI, 88.6% to 90.9%) with CADx assistance (p<0.001). The proportion of HC predictions increased from 64.2% to 75.4% (p<0.001). Novice endoscopists showed marked improvement with CADx (74.1% vs 88.8%; p<0.001). CADx-assisted diagnoses nearly met SODA and PIVI thresholds under the 3-second rule. Additional analysis demonstrated that CADx assistance significantly improved interobserver agreement and ground truth, particularly for novices (κ=0.37 to κ=0.65; p<0.001).
Conclusions
Integrating CADx with the 3-second rule significantly enhances the performance of endoscopists in the optical diagnosis of colorectal polyps, with the greatest benefit observed among novice endoscopists.
6.Molecular determinants of outcome to gemcitabine, cisplatin, and nab-paclitaxel in patients with advanced biliary tract cancer
Daeseong KIM ; Nam Suk SIM ; Seonjeong WOO ; Min Hwan KIM ; Choong-kun LEE ; Seung Soo HONG ; Sung Hyun KIM ; Ho Kyoung HWANG ; Chang Moo KANG ; Woo Jung LEE ; Jung Hyun JO ; Taek CHUNG ; Sohyun HWANG ; Beodeul KANG ; Jung Sun KIM ; Chang-Il KWON ; Sangwoo KIM ; Hong Jae CHON ; Chang Gon KIM ; Young Nyun PARK ; Hye Jin CHOI
Clinical and Molecular Hepatology 2026;32(2):721-736
Background/Aims:
Biliary tract cancer (BTC) is a rare malignancy with poor prognosis. We investigated genomic determinants of clinical benefit from gemcitabine, cisplatin, and nab-paclitaxel (GAP) versus gemcitabine and cisplatin (GC) in advanced BTC.
Methods:
Clinical and genomic data using TruSight Oncology 500 were analyzed from patients treated with GAP (N=198) or GC (N=89) as first-line therapy.
Results:
With a median follow-up of 33.0 months, GAP modestly improved progression-free survival (PFS) (hazard ratio [HR] 0.764; 95% confidence interval [CI] 0.591–0.989) without significant overall survival (OS) difference compared to GC. Genomic profiling revealed frequent alterations in TP53 (35.2%), KRAS (16.4%), SMAD4 (10.5%), and TNFRSF14 (10.5%), involving RTK/RAS (44.3%), TP53 (41.8%), and PI3K (20.2%) pathways. Single-gene mutations did not predict treatment benefit. However, pathway-level analysis identified PI3K pathway activation as significantly associated with inferior PFS (HR 2.148; 95% CI 1.478–3.124) and OS (HR 2.096; 95% CI 1.413–3.109) in patients receiving GAP, an effect not observed with GC. Importantly, GAP conferred clinical benefit only in patients without PI3K pathway activation, while no survival advantage was seen in those with such alterations (Pinteraction=0.023 for PFS, Pinteraction=0.003 for OS). Similar results were obtained in the independent validation cohort treated with GAP (N=103) or GC (N=64) for BTC.
Conclusions
Genomic profiling using next-generation sequencing identified PI3K pathway activation as key molecular determinant that differentiates patient outcomes between GAP and GC treatments in advanced BTC.
7.Fully automated artificial intelligence– based echocardiographic analysis substantially reduces workflow time while preserving measurement accuracy: a pilot study
Jonghee SUN ; Yeonyee E. YOON ; Jiyeon LEE ; Ganghan LEE ; Minjung BAK ; Jiesuck PARK ; Hong‑Mi CHOI ; In‑Chang HWANG ; Goo‑Yeong CHO
Journal of Cardiovascular Imaging 2026;34(1):10-
Background:
Transthoracic echocardiography (TTE) requires time-intensive integration of quantitative measure‑ ments and qualitative visual assessment. Fully automated artificial intelligence (AI)-based analysis may reduce total analysis time while preserving accuracy, but systematic real-world validation remains limited.
Methods:
This prospective, single-center pilot study enrolled 40 TTE examinations. Identical deidentified DICOM datasets were independently provided to a trained cardiac sonographer and a fully automated AI system comprising quantitative and qualitative visual interpretation modules. All outputs were compared with a cardiologist-adjudicated reference standard. Primary endpoints were total analysis time and noninferiority of AI-derived left ventricular ejection fraction (LVEF) versus the reference standard, with a prespecified margin of 3 percentage points (one-sided α = 0.025).
Results:
Median analysis time was 94 s (interquartile range [IQR], 82–106 s) for the AI workflow versus 490 s (IQR, 438–626 s) for the human workflow (P < 0.001). AI-derived LVEF met the noninferiority criterion (mean difference, 0.00 percentage points; upper one-sided 95% confidence bound, 1.41 percentage points; P < 0.001), with an intraclass correlation coefficient (ICC) of 0.902 (95% confidence interval, 0.822–0.947). ICCs for secondary quantitative indi‑ ces ranged from 0.625 to 0.989. For aortic regurgitation severity grading, AI’s overall accuracy was 75.0% (quadratic weighted κ = 0.762), compared with 82.5% for human interpretation (κ = 0.812, McNemar P = 0.579).
Conclusions
Fully automated AI-assisted TTE analysis substantially reduced total analysis time while maintaining noninferior LVEF accuracy and acceptable performance across secondary quantitative and qualitative indices. These findings support the use of AI as a practical workflow accelerator in routine echocardiography.
8.Risk Factors of Complications in Patients With Persistent or Long-Standing Persistent Atrial Fibrillation/Atrial Flutter Who Underwent Electrical Cardioversion:A Multicenter Cardioversion Registry
Ki-Hun KIM ; Junbeom PARK ; Donghwan KU ; Jino PARK ; Seunghwan KIM ; Dong-Kie KIM ; Doo-Il KIM ; Sun Gyu CHOI ; Pil-Sung YANG ; Ju Youn KIM ; Jaemin SHIM ; Jinhee AHN ; Sung Ho LEE ; Sung Il IM ; Hong Euy LIM
Journal of Korean Medical Science 2026;41(1):e19-
Background:
Identifying the risks related to the complications of electrical cardioversion (ECV) can alert the determinaton of rhythm control in patients with atrial fibrillation (AF).
Methods:
We retrospectively reviewed 1,058 patients who underwent ECV for persistent or long-standing persistent AF/atrial flutter (AFL) from multiple centers. Patients were classified into the no-complication (1,023 patients) and complication (35 patients) groups based on the following major complications: stroke and/or systemic embolism (SSE), myocardial infarction, major bleeding, implantation of cardiac implantable electronic devices, ventricular tachycardia/fibrillation, and death at 1 year follow-up after ECV.
Results:
Compared with the no-complication group, the complication group exhibited a higher proportion of female patients (37% vs. 22%), as well as a higher proportion of patients with older age (67 ± 11 vs. 61 ± 10 years), diabetes mellitus (DM) (49% vs. 24%), heart failure (HF) (49% vs. 30%), SSE (23% vs. 9%), high CHA 2 DS 2 -VASc (CV) score (3.6 ± 1.8 vs.2.2 ± 1.4), low left ventricular ejection fraction (LVEF) (50 ± 16% vs. 58 ± 21%), and high left atrial volume index (LAVI) (51 ± 26 vs. 40 ± 20 mL/m 2 ). Class I and III antiarrhythmics were less prescribed in the complication group than in the no-complication group (57% vs.76%). Univariate analysis for complications revealed age (≥ 65 years), female sex, DM, HF, SSE, LVEF (< 50%), LAVI (≥ 40 mL/m 2 ), CV score (≥ 3), bradycardia on Holter (< 60/min), and no antiarrhythmics as risk factors. Among these, multivariate analysis revealed clinical significance of female sex and SSE.
Conclusion
Female sex and a history of SSE were the most important risk factors of complications in patients with persistent or long-standing persistent AF/AFL who underwent ECV.
9.Effect of scan body geometric configuration and library design on digital implant impression accuracy
Hong Seok MOON ; Ahreum CHOI ; Kyung Chul OH ; Minji SUN ; Jaeyoung KIM
The Journal of Advanced Prosthodontics 2026;18(1):55-66
PURPOSE:
. The purpose of this in vitro study was to evaluate how variations in scan body geometry, specifically body height and the length of the flat indexing surface (FIS), affect linear and angular accuracy when combined with truncated or full-geometry library files.
MATERIALS AND METHODS:
. Nine scan body geometries were fabricated by combining three body heights (4, 5, and 6 mm) with three FIS lengths (1, 2, and 3 mm). Digital impressions were superimposed onto truncated or full-geometry library files. Linear deviation (ΔD) and angular deviation (ΔA) were calculated by comparing aligned scan bodies with coordinate measuring machine references. Linear and angular deviations were compared between library types using the Mann–Whitney U test, and differences among body heights and FIS lengths were evaluated using the Kruskal–Wallis test with Dunn’s post-hoc test (α = .05).
RESULTS:
. Linear deviation remained within a comparable range, and most geometry–library comparisons did not show a significant difference from body height, FIS length, or library morphology (P > .05). Angular deviation demonstrated geometry-dependent behavior, increasing only in the 4-mm body paired with larger FIS lengths, particularly when fullgeometry libraries were used. No significant angular differences were observed in the 5-mm or 6-mm body groups.
CONCLUSION
. Digital implant registration remained stable across most configurations. Shortened scan bodies performed reliably when FIS dimensions were preserved. Angular accuracy was more sensitive to geometry-library interactions, with truncated libraries improving stability.
10.Asparaginase-Associated Pancreatitis and Pancreatic Pseudocyst Managed with Endoscopic Cystogastrostomy in Adult Acute Lymphoblastic Leukemia
Gyewon PARK ; Eun Sun KIM ; Hyuk Soon CHOI ; Bora KEUM ; Yoon Tae JEEN ; Hoon Jai CHUN ; Hong Sik LEE ; Jae Min LEE
Korean Journal of Pancreas and Biliary Tract 2025;30(1):31-35
Anticancer treatment for acute lymphocytic leukemia is based on drugs such as methotrexate, 6-mercaptopurine, vincristine, and asparaginase. Asparaginase-related pancreatitis is known to have an incidence of up to 18%, and is a major cause of discontinuation of anticancer treatment for leukemia due to acute onset and chronic complications. There were various cases of treatment of peripancreatic fluid retention caused by anticancer drugs in leukemia patients. Use of lumen-apposing metal stents (LAMS) for walled-off necrosis (WON) drainage has recently increased. The electrocautery-enhanced delivery system allowed simpler and faster stent placement, streamlining the overall procedure and potentially reducing procedure time. Therefore, favorable outcomes have been reported with the use of LAMS for endoscopic drainage of various conditions. In this paper, we discuss a case in which hot-system LAMS was performed to treat L-asparaginase-induced acute pancreatitis and pancreatic pseudocyst in an adult patient with acute lymphoblastic leukemia.

Result Analysis
Print
Save
E-mail