1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Regenerative endodontic procedures for a prematurely erupted maxillary premolar with immature roots and chronic apical periodontitis: a case report and literature review
WANG Xiao ; XIA Shang ; LIU Yan ; YANG Yu' ; e ; LI Hong
Journal of Prevention and Treatment for Stomatological Diseases 2025;33(8):666-671
Objective:
To investigate treatment strategies for chronic periapical periodontitis in prematurely erupted premolars and provide guidance for managing pulp and periapical diseases in young permanent teeth with immature roots.
Methods:
A regenerative endodontic procedure (REP) was performed on a prematurely erupted maxillary left first premolar (tooth 24) at Nolla stage Ⅶ with chronic apical periodontitis, following standardized protocols including root canal irrigation, disinfection, and coronal sealing. The case was followed up, and a literature review was conducted.
Results:
Clinical resolution of symptoms was observed on tooth 24, with sustained root development. After a 20-month follow-up, the tooth had restored biological function. Literature synthesis revealed that periapical infections in prematurely erupted permanent teeth predominently arise from pulp exposure and bacterial infection, with retrograde infection being rare. For young permanent teeth with necrotic pulp, regenerative endodontic procedures has been established as the treatment of choice to promote apical closure and root maturation. The critical steps of regenerative endodontic procedures include thorough disinfection, induced bleeding to form a fibrin scaffold, and coronal sealing to facilitate stem cell recruitment and differentiation.
Conclusion
Regenerative endodontic procedures represents an effective and viable treatment option for prematurely erupted young permanent teeth with chronic periapical periodontitis.
3.A SINGLE CASE OF COINFECTION WITH SEVERE FEVER WITH THROMBOCYTOPENIA SYNDROME AND SCRUB TYPHUS IN DALIAN,CHINA
Ke-Ya WU ; Ling-Yan KONG ; Jun XING ; Wei PANG ; Yi ZHOU ; Yu-Hong LIANG ; Sheng-Hao JIN ; Shang QI
Acta Parasitologica et Medica Entomologica Sinica 2025;32(1):48-51
This article reports a first case of combined infection with severe fever with thrombocytopenia syndrome(SFTS)and scrub typhus in Dalian City.The patient was admitted to the hospital due to recurrent fever for 7 days and loss of consciousness for 1 day.Pathogen metagenomic sequencing(mNGS),SFTSV quantitative PCR,and enzyme-linked immunosorbent assay(ELISA)IgM tests were performed,showing positive results for Orientia tsutsugamushi and SFTSV nucleic acids.Based on clinical manifestations and epidemiological history,the patient was diagnosed with combined infections.
4.Urethral Sparing versus Trans-Vesical Robot-Assisted Simple Prostatectomy:A Comparative Analysis of Perioperative, Postoperative Outcomes, and Ejaculation Preservation
Yu Seob SHIN ; Shang Weon PAK ; Wonku HWANG ; Seon Beom JO ; Jong Wook KIM ; Mi Mi OH ; Hong Seok PARK ; Du Geon MOON ; Sun Tae AHN
The World Journal of Men's Health 2025;43(2):387-395
Purpose:
To compare the perioperative and postoperative outcomes between traditional trans-vesical robot-assisted simple prostatectomy (TV-RASP) and the newly introduced urethral-sparing (US) RASP.
Materials and Methods:
We retrospectively reviewed 42 patients who underwent TV-RASP (n=22) or US-RASP (n=20) performed by two experienced surgeons at two tertiary centers. Perioperative outcomes including operation time, estimated blood loss, length of hospital stay, and catheterization time were assessed. Postoperative outcomes were evaluated using the International Prostate Symptom Score (IPSS), quality of life (QoL), uroflowmetry parameters, Male Sexual Health Questionnaire-Ejaculation Dysfunction-Short Form (MSHQ-EjD-SF) scores, and maintenance of anterograde ejaculation.
Results:
This study analyzed 22 and 20 patients who underwent TV-RASP and US-RASP, respectively. Except for the TV-RASP group being older (70.0 years) than the US-RASP group (64.5 years) (p=0.028), no differences among other baseline characteristics existed. Perioperative outcomes indicated that hospital stay and catheterization time were significantly shorter in the US-RASP group than in the TV-RASP group (p<0.001). At postoperative month 1, the median IPSS and QoL scores were significantly better in the US-RASP group than in the TV-RASP group (p=0.001 and p=0.002, respectively). However, at months 6 and 12, no significant differences were noted in IPSS, QoL, maximum flow rate, and postvoid residual urine between the two groups. Sexually active patients in the US-RASP group maintained postoperative MSHQ-EjD functional and bother scores, whereas the TV-RASP group experienced a decline. Notably, 75.0% of patients in the US-RASP group preserved antegrade ejaculation, compared to only 20.0% in the TV-RASP group (p<0.001).
Conclusions
US-RASP is not inferior to TV-RASP in terms of functional outcomes. In addition, US-RASP yielded more rapid symptom improvements and preserved antegrade ejaculation than TV-RASP. However, larger prospective studies are required to confirm these findings and to further investigate the long-term efficacy and safety of US-RASP.
5.Rapid On-site Analysis of Four Prohibited Sex Hormones in Cosmetics Using Online Derivatization Reaction and A Miniature Mass Spectrometer
Li-Li TONG ; Yan-Hong HU ; Ren-You YANG ; Yue-Guang LYU ; Yu-Han SHANG ; Qing LYU ; Qing ZHANG ; Qiang WANG ; Xiang-Yu GUO
Chinese Journal of Analytical Chemistry 2025;53(10):1623-1630
Due to the poor ionization efficiency and the weak mass spectrometry(MS)intensity of weakly polar substances,direct analysis using the traditional electrospray ionization mass spectrometry(ESI-MS)is a big challenge.In this study,a novel rapid on-site detection method of four prohibited sex hormones in cosmetics was proposed using online derivatization strategy coupled with a miniature mass spectrometer.The target substances in the samples were extracted by a custom-made polyaniline/multi-walled carbon nanotube solid-phase microextraction(SPME)probe.The stirring speed was 200 r/min,the extraction temperature was 40℃,and the extraction time was 2 min.A pulled dual-channel θ borosilicate glass capillary emitter was used as the nano-ESI ion source.The SPME probe was inserted into the channel containing methanol in theθborosilicate glass capillary.When the spray voltage was applied,the four sex hormones were desorbed and formed spray microdroplets,which then collided with the hydroxylamine microdroplets generated from the other channel.The microdroplets of reaction product entered into the miniature mass spectrometer for direct analysis.The limits of detection(LOD)and limits of quantification(LOQ)for the four sex hormones were 10-20 ng/mL and 20-50 ng/mL,respectively.The recoveries were from 84.6%to 107.8%with the relative standard deviations(RSD)from 4.1%to 11.6%.Compared to detection without derivatization,the MS signals of the four target substances were increased by 3 to 15 times.This method was simple,rapid,highly efficient and sensitive,and suitable for on-site rapid analysis of weakly polar sex hormones in cosmetics.
6.Visualization analysis on research literature about Taohong Siwu Decoction based on CiteSpace
Shang LIU ; Yan CHEN ; Kanjana THANA ; Can WANG ; Ziqiong LONG ; Xingyue CHEN ; Xiaoxiao ZHANG ; Yitong HONG
International Journal of Traditional Chinese Medicine 2025;47(3):380-386
Objective:To understand the current research status, hot issues, and development trends of Taohong Siwu Decoction.Methods:Research literature about Taohong Siwu Decoction was retrieved from Wanfang Data, CBM, CNKI, and Chongqing VIP from January 1, 2014, to August 13, 2024. Excel 2024 software was used to analyze the annual number of publications, the source journals, literature types and the distribution of diseases and syndromes. CiteSpace 6.3.R3 software was used for visualization analysis on the authors, research institutions and key words.Results:A total of 2 519 articles were included, and the annual publication volume showed a fluctuating growth trend. There were 396 source journals, of which Medicine and Health published the most (80 articles); 208 authors were involved, and the core authors included Peng Daiyin of Anhui University of Chinese Medicine, Zhu Fuping of the First Affiliated Hospital of Hunan University of Chinese Medicine, Sun Shaoqiu of the Second Affiliated Hospital of Hunan University of Chinese Medicine and so on. The main research institutions in this field included Hunan University of Chinese Medicine and its affiliated hospitals. The high-frequency keywords included fracture, irregular menstruation, clinical efficacy, chloasma, Wuling Powder, experience of famous doctors, elderly, etc. Keywords could be clustered into 11 modules.Conclusions:The current research hotspots of Taohong Siwu Decoction mainly focus on the exploration of multi-system disease treatment, individualized syndrome differentiation and treatment, pharmacology and metabolic mechanism of Chinese materia medica, etc. Among them, the in-depth study of drug composition and metabolism, network pharmacology and mechanism is the research frontier in this field.
7.Translational Research of Electromagnetic Fields on Diseases Related With Bone Remodeling: Review and Prospects
Peng SHANG ; Jun-Yu LIU ; Sheng-Hang WANG ; Jian-Cheng YANG ; Zhe-Yuan ZHANG ; An-Lin LI ; Hao ZHANG ; Yu-Hong ZENG
Progress in Biochemistry and Biophysics 2025;52(2):439-455
Electromagnetic fields can regulate the fundamental biological processes involved in bone remodeling. As a non-invasive physical therapy, electromagnetic fields with specific parameters have demonstrated therapeutic effects on bone remodeling diseases, such as fractures and osteoporosis. Electromagnetic fields can be generated by the movement of charged particles or induced by varying currents. Based on whether the strength and direction of the electric field change over time, electromagnetic fields can be classified into static and time-varying fields. The treatment of bone remodeling diseases with static magnetic fields primarily focuses on fractures, often using magnetic splints to immobilize the fracture site while studying the effects of static magnetic fields on bone healing. However, there has been relatively little research on the prevention and treatment of osteoporosis using static magnetic fields. Pulsed electromagnetic fields, a type of time-varying field, have been widely used in clinical studies for treating fractures, osteoporosis, and non-union. However, current clinical applications are limited to low-frequency, and research on the relationship between frequency and biological effects remains insufficient. We believe that different types of electromagnetic fields acting on bone can induce various “secondary physical quantities”, such as magnetism, force, electricity, acoustics, and thermal energy, which can stimulate bone cells either individually or simultaneously. Bone cells possess specific electromagnetic properties, and in a static magnetic field, the presence of a magnetic field gradient can exert a certain magnetism on the bone tissue, leading to observable effects. In a time-varying magnetic field, the charged particles within the bone experience varying Lorentz forces, causing vibrations and generating acoustic effects. Additionally, as the frequency of the time-varying field increases, induced currents or potentials can be generated within the bone, leading to electrical effects. When the frequency and power exceed a certain threshold, electromagnetic energy can be converted into thermal energy, producing thermal effects. In summary, external electromagnetic fields with different characteristics can generate multiple physical quantities within biological tissues, such as magnetic, electric, mechanical, acoustic, and thermal effects. These physical quantities may also interact and couple with each other, stimulating the biological tissues in a combined or composite manner, thereby producing biological effects. This understanding is key to elucidating the electromagnetic mechanisms of how electromagnetic fields influence biological tissues. In the study of electromagnetic fields for bone remodeling diseases, attention should be paid to the biological effects of bone remodeling under different electromagnetic wave characteristics. This includes exploring innovative electromagnetic source technologies applicable to bone remodeling, identifying safe and effective electromagnetic field parameters, and combining basic research with technological invention to develop scientifically grounded, advanced key technologies for innovative electromagnetic treatment devices targeting bone remodeling diseases. In conclusion, electromagnetic fields and multiple physical factors have the potential to prevent and treat bone remodeling diseases, and have significant application prospects.
8.Finite element analysis of three internal fixation modalities for treatment of Pauwels type Ⅲ femoral neck fractures under different loading conditions
Zhenggang LI ; Xuehong SHANG ; Zhang WU ; Hong LI ; Chaojun SUN ; Huadong CHEN ; Zhe SUN ; Yi YANG
Chinese Journal of Tissue Engineering Research 2025;29(3):455-463
BACKGROUND:There is still no consensus on the optimal internal fixation for the treatment of Pauwels Ⅲ femoral neck fracture,and most of the related finite element analyses have been performed using a single simplified loading condition,and the biomechanical properties of commonly used internal fixation devices need to be further investigated. OBJECTIVE:To analyze the biomechanical characteristics of Pauwels Ⅲ femoral neck fractures treated with cannulated compression screw,dynamic hip screw,and femoral neck system by finite element method under different loading conditions of single-leg standing loads and sideways fall loads. METHODS:The DICOM data of healthy adult femur were obtained by CT scanning,imported into Mimics 15.0 software to obtain the rough model of bone tissue.The data exported from Mimics were optimized by Geomagics software,and then three internal fixation models were built and assembled with the femur model according to the parameters of the clinical application of the cannulated compression screw,dynamic hip screw,and femoral neck system by using Pro/E software.Finally,the three internal fixation models were imported into Ansys software for loading and calculation to analyze the stress distribution and displacement of the femur and the internal fixation under different working conditions of single-leg standing loads and sideways fall loads,as well as the stress characteristics of the calcar femorale and Ward's triangle. RESULTS AND CONCLUSION:(1)Under the single-leg standing load and the sideways fall load,the proximal femoral stress of the three internal fixation models was mainly distributed above the fracture end of the femoral neck.The peak stress of the proximal femoral end,fracture end,Ward triangle,and calcar femorale of the three internal fixation models were the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(2)Under the single-leg standing load and the sideways fall load,the peak displacement of the proximal femur of the three internal fixation models was all located at the top of the femoral head,and the peak displacement was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(3)The peak displacement of the three internal fixation models was all located at the top of the internal fixation device under the single-leg standing and sideways fall loading conditions,and the peak displacement values were the smallest in the femoral neck system internal fixation model and the largest in the cannulated compression screw internal fixation model.(4)The internal fixation stress of the three internal fixation models was mainly distributed in the area near the fracture end of the internal fixation device under the single-leg standing and sideways fall loads,and the peak value of internal fixation stress was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(5)These results suggest that the mechanical stability of the femoral neck system is the best,but there may be a risk of stress shielding of the fracture end and calcar femorale.The stress of the internal fixation device of the femoral neck system is more dispersed,and the risk of internal fixation break is lower.
9.Role and mechanism of platelet-derived growth factor BB in repair of growth plate injury
Hongcheng PENG ; Guoxuan PENG ; Anyi LEI ; Yuan LIN ; Hong SUN ; Xu NING ; Xianwen SHANG ; Jin DENG ; Mingzhi HUANG
Chinese Journal of Tissue Engineering Research 2025;29(7):1497-1503
BACKGROUND:In the initial stage of growth plate injury inflammation,platelet-derived growth factor BB promotes the repair of growth plate injury by promoting mesenchymal progenitor cell infiltration,chondrogenesis,osteogenic response,and regulating bone remodeling. OBJECTIVE:To elucidate the action mechanism of platelet-derived growth factor BB after growth plate injury. METHODS:PubMed,VIP,WanFang,and CNKI databases were used as the literature sources.The search terms were"growth plate injury,bone bridge,platelet-derived growth factor BB,repair"in English and Chinese.Finally,66 articles were screened for this review. RESULTS AND CONCLUSION:Growth plate injury experienced early inflammation,vascular reconstruction,fibroossification,structural remodeling and other pathological processes,accompanied by the crosstalk of chondrocytes,vascular endothelial cells,stem cells,osteoblasts,osteoclasts and other cells.Platelet-derived growth factor BB,as an important factor in the early inflammatory response of injury,regulates the injury repair process by mediating a variety of cellular inflammatory responses.Targeting the inflammatory stimulation mediated by platelet-derived growth factor BB may delay the bone bridge formation process by improving the functional activities of osteoclasts,osteoblasts,and chondrocytes,so as to achieve the injury repair of growth plate.Platelet-derived growth factor BB plays an important role in angiogenesis and bone repair tissue formation at the injured site of growth plate and intrachondral bone lengthening function of uninjured growth plate.Inhibition of the coupling effect between angiogenesis initiated by platelet-derived growth factor BB and intrachondral bone formation may achieve the repair of growth plate injury.
10.Urethral Sparing versus Trans-Vesical Robot-Assisted Simple Prostatectomy:A Comparative Analysis of Perioperative, Postoperative Outcomes, and Ejaculation Preservation
Yu Seob SHIN ; Shang Weon PAK ; Wonku HWANG ; Seon Beom JO ; Jong Wook KIM ; Mi Mi OH ; Hong Seok PARK ; Du Geon MOON ; Sun Tae AHN
The World Journal of Men's Health 2025;43(2):387-395
Purpose:
To compare the perioperative and postoperative outcomes between traditional trans-vesical robot-assisted simple prostatectomy (TV-RASP) and the newly introduced urethral-sparing (US) RASP.
Materials and Methods:
We retrospectively reviewed 42 patients who underwent TV-RASP (n=22) or US-RASP (n=20) performed by two experienced surgeons at two tertiary centers. Perioperative outcomes including operation time, estimated blood loss, length of hospital stay, and catheterization time were assessed. Postoperative outcomes were evaluated using the International Prostate Symptom Score (IPSS), quality of life (QoL), uroflowmetry parameters, Male Sexual Health Questionnaire-Ejaculation Dysfunction-Short Form (MSHQ-EjD-SF) scores, and maintenance of anterograde ejaculation.
Results:
This study analyzed 22 and 20 patients who underwent TV-RASP and US-RASP, respectively. Except for the TV-RASP group being older (70.0 years) than the US-RASP group (64.5 years) (p=0.028), no differences among other baseline characteristics existed. Perioperative outcomes indicated that hospital stay and catheterization time were significantly shorter in the US-RASP group than in the TV-RASP group (p<0.001). At postoperative month 1, the median IPSS and QoL scores were significantly better in the US-RASP group than in the TV-RASP group (p=0.001 and p=0.002, respectively). However, at months 6 and 12, no significant differences were noted in IPSS, QoL, maximum flow rate, and postvoid residual urine between the two groups. Sexually active patients in the US-RASP group maintained postoperative MSHQ-EjD functional and bother scores, whereas the TV-RASP group experienced a decline. Notably, 75.0% of patients in the US-RASP group preserved antegrade ejaculation, compared to only 20.0% in the TV-RASP group (p<0.001).
Conclusions
US-RASP is not inferior to TV-RASP in terms of functional outcomes. In addition, US-RASP yielded more rapid symptom improvements and preserved antegrade ejaculation than TV-RASP. However, larger prospective studies are required to confirm these findings and to further investigate the long-term efficacy and safety of US-RASP.


Result Analysis
Print
Save
E-mail