1.Mechanism study of SIRT3 alleviating oxidative-stress injury in renal tubular cells by promoting mitochondrial biogenesis via regulating mitochondrial redox balance
Yaojun LIU ; Jun ZHOU ; Jing LIU ; Yunfei SHAN ; Huhai ZHANG ; Pan XIE ; Liying ZOU ; Lingyu RAN ; Huanping LONG ; Lunli XIANG ; Hong HUANG ; Hongwen ZHAO
Organ Transplantation 2026;17(1):86-94
Objective To elucidate the molecular mechanism of sirtuin-3 (SIRT3) in regulating mitochondrial biogenesis in human renal tubular epithelial cells. Methods Cells were stimulated with different concentrations of H2O2 and divided into four groups: control (NC), 50 μmol/L H2O2, 110 μmol/L H2O2 and 150 μmol/L H2O2. SIRT3 protein expression was then measured. SIRT3 was knocked down with siRNA, and cells were further assigned to five groups: control (NC), negative-control siRNA (NCsi), SIRT3-siRNA (siSIRT3), NCsi+H2O2, and siSIRT3+H2O2. After 24 h, cellular adenosine triphosphate (ATP) and mitochondrial superoxide anion (O2•−) levels were determined, together with mitochondrial expression of SIRT3, peroxisome proliferator-activated receptor γ coactivator-1α (PGC-1α), nuclear respiratory factor 1 (NRF1), mitochondrial transcription factor A (TFAM), superoxide dismutase 2 (SOD2), acetylated-SOD2 and adenosine monophosphate activated protein kinase α1 (AMPKα1). Results The 110 and 150 μmol/L H2O2 decreased SIRT3 protein (both P<0.05). ATP and mitochondrial O2•− did not differ between NC and NCsi groups (both P>0.05). Compared to the NCsi group, the siSIRT3 group exhibited elevated O2•− level, decreased SIRT3 protein and increased expression levels of SOD2 and acetylated SOD2 protein (all P<0.05). Compared to the NCsi group, the NCsi+H2O2 group exhibited decreased cellular ATP levels, elevated mitochondrial O2•− levels, and reduced protein expression levels of SIRT3, SOD2, TFAM, AMPKα1, PGC-1α and NRF1 (all P<0.05). Compared with the siSIRT3 group, the siSIRT3+H2O2 group showed a decrease in cellular ATP levels, an increase in mitochondrial O2•− levels, a decrease in SIRT3, SOD2, TFAM, AMPKα1, PGC-1α and NRF1 protein expression levels and a decrease in acetylated SOD2 protein expression levels (all P<0.05). Compared with the NCsi+H2O2 group, the siSIRT3+H2O2 group showed a decrease in cellular ATP levels, an increase in mitochondrial O2•− levels, a decrease in SIRT3, AMPKα1, PGC-1α and NRF1, TFAM protein expression levels, and an increase in SOD2 and acetylated SOD2 protein expression levels (all P<0.05). Conclusions SIRT3 promotes mitochondrial biogenesis in tubular epithelial cells via the AMPK/PGC-1α/NRF1/TFAM axis, representing a key mechanism through which SIRT3 ameliorates oxidative stress-induced mitochondrial dysfunction.
2.Clinical Advantages of Traditional Chinese Medicine in Treatment of Childhood Simple Obesity: Insights from Expert Consensus
Qi ZHANG ; Yingke LIU ; Xiaoxiao ZHANG ; Guichen NI ; Heyin XIAO ; Junhong WANG ; Liqun WU ; Zhanfeng YAN ; Kundi WANG ; Jiajia CHEN ; Hong ZHENG ; Xinying GAO ; Liya WEI ; Qiang HE ; Qian ZHAO ; Huimin SU ; Zhaolan LIU ; Dafeng LONG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(6):238-245
Childhood simple obesity has become a significant public health issue in China. Modern medicine primarily relies on lifestyle interventions and often suffers from poor long-term compliance, while pharmacological options are limited and associated with potential adverse effects. Traditional Chinese Medicine (TCM) has a long history in the prevention and management of this condition, demonstrating eight distinct advantages, including systematic theoretical foundation, diversified therapeutic approaches, definite therapeutic efficacy, high safety profile, good patient compliance, comprehensive intervention strategies, emphasis on prevention, and stepwise treatment protocols. Additionally, TCM is characterized by six distinctive features: the use of natural medicinal substances, non-invasive external therapies, integration of medicinal dietetics, simple exercise regimens, precise syndrome differentiation, and diverse dosage forms. By combining internal and external treatments, TCM facilitates individualized regimen adjustment and holistic regulation, demonstrating remarkable effects in improving obesity-related metabolic indicators, regulating constitutional imbalance, and promoting healthy behaviors. However, challenges remain, such as inconsistent operational standards, insufficient high-quality clinical evidence, and a gap between basic research and clinical application. Future efforts should focus on accelerating the standardization of TCM diagnosis and treatment, conducting multicenter randomized controlled trials, and fostering interdisciplinary integration, so as to enhance the scientific validity and international recognition of TCM in the prevention and treatment of childhood obesity.
3.Quality evaluation of Qingwen hufei granules based on fingerprints combined with multi-component content determination
Huiying ZHOU ; Yuan WANG ; Yani WANG ; Yun YANG ; Bo WANG ; Shuanzhu YANG ; Liping CAO ; Hong ZHANG ; Kaihua LONG
China Pharmacy 2026;37(3):338-343
OBJECTIVE To provide a scientific basis for the quality evaluation and clinical application of Qingwen hufei granules. METHODS Fourteen batches of Qingwen hufei granules were used as samples to establish high-performance liquid chromatography (HPLC) fingerprints using the Similarity Evaluation System for Chromatographic Fingerprint of Traditional Chinese Medicine (2012 Edition). The chromatographic peaks were identified and the similarity was evaluated. Cluster analysis (CA), principal component analysis (PCA), and orthogonal partial least squares-discriminant analysis (OPLS-DA) were used to conduct chemical pattern recognition analysis on the 14 batches of samples. Meanwhile, the contents of neochlorogenic acid (NGA), chlorogenic acid (CHA), cryptochlorogenic acid (CGA), forsythoside A (FTA), 3,5-O-dicaffeoylquinic acid (3,5-O- DA), 4,5-O-dicaffeoylquinic acid (4,5-O-DA), and angoroside C (AGC) in the samples were determined by HPLC. RESULTS The methodological investigation results of both the fingerprint and the content determination complied with the relevant requirements. Fourteen common peaks were indicated in the HPLC fingerprints of the 14 batches of samples, and 7 of them were identified [NGA (peak 2), CHA (peak 3), CGA (peak 5), FTA (peak 11), 3,5-O-DA (peak 12), 4,5-O-DA (peak 13), and AGC (peak 14)]; the similarity of each sample was greater than 0.94. The results of CA and PCA showed that the samples could be classified into 3 categories; the results of OPLS-DA indicated that peak 4 (unknown), peak 11 (FTA), peak 8 (unknown), peak 9 (unknown), and peak 1 (unknown) were the differential components. The content ranges of NGA, CHA, CGA, 3,5-O-DA, FTA, 4,5-O-DA and AGC in the 14 batches of samples were 0.210 4-0.458 7, 0.269 1-0.506 3, 0.228 1-0.461 1, 0.443 9-1.044 6, 0.066 7-0.155 7, 0.062 8-0.143 8, and 0.057 4-0.105 7 mg/g, respectively. CONCLUSIONS The HPLC fingerprint and multi-component content determination methods established in this study are efficient and reliable, and can be used for the quality evaluation of Qingwen hufei granules.
4.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
5.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
6.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
7.Efficient Loading and Targeted Delivery of Plant Exosomes
Meng XU ; Long-Jiao ZHU ; Jie LI ; Chong-Bin LEI ; Yang-Zi ZHANG ; Hong-Tao TIAN ; Wen-Tao XU
Progress in Biochemistry and Biophysics 2026;53(6):1597-1608
Plant-derived extracellular vesicles (PDEVs) are nanoscale extracellular vesicles secreted by plant cells, characterized by a lipid bilayer structure. These vesicles carry a variety of bioactive molecules, including proteins, nucleic acids, and lipids, and play essential roles in intercellular communication and physiological regulation in plants. Compared to animal-derived extracellular vesicles, PDEVs offer several advantages, such as a broad range of sources, high biocompatibility, low immunogenicity, and low production costs. Furthermore, PDEVs have demonstrated remarkable potential as natural nanocarriers for drug delivery, due to their ability to efficiently traverse biological barriers, such as the blood-brain barrier, making them promising candidates for drug delivery systems. This review systematically elaborates on the complex composition of PDEVs, which consists of lipids, proteins, and nucleic acids, the typical structural characteristics of their lipid bilayers ranging from 30 to 150 nm, and their versatile loading capabilities as drug carriers, efficiently encapsulating various types of therapeutic agents such as hydrophilic small molecules, hydrophobic drugs, nucleic acids, and proteins. We systematically summarize the recent advancements in strategies for enhancing the loading efficiency of PDEVs, which include methods such as co-incubation, ultrasound-assisted loading, electroporation, freeze-thaw cycles, and microfluidic technology. These techniques are evaluated based on their underlying principles, suitable drug types, and their respective advantages. In addition to loading strategies, we focus on the engineered approaches to achieve targeted delivery using PDEVs, such as genetic engineering modifications, chemical ligand conjugation, membrane fusion technology, and polyethylene glycol (PEG) modification. We discuss the mechanisms of these strategies in enhancing targeting efficiency, prolonging in vivo circulation time, and improving therapeutic efficacy. Further, this review highlights the application of PDEVs in various disease models, including tumor, skin inflammation, metabolic disorders, and neurodegenerative diseases, showcasing their therapeutic potential as multifunctional delivery platforms. The ability of PDEVs to encapsulate diverse therapeutic agents and target specific tissues or cells opens up new avenues for the treatment of complex diseases, offering advantages over conventional drug delivery systems. However, despite the promising applications of PDEVs, several challenges remain in their development and clinical translation. These challenges include variability in source materials, standardization of preparation processes, quality control, scalability of production, and the need for clinical validation. To overcome these obstacles, the integration of advanced technologies such as artificial intelligence-assisted design and multi-omics analysis is proposed as a way to facilitate the precise development of PDEVs. These emerging technologies hold the potential to further enhance the precision and effectiveness of plant-based drug delivery systems, ultimately advancing the field of precision medicine. In conclusion, the use of PDEVs as a platform for drug delivery represents a promising area of research with the potential to revolutionize therapeutic strategies. Their ability to encapsulate and deliver a wide variety of bioactive molecules, along with their inherent advantages in biocompatibility and versatility, makes them a valuable tool in the development of more efficient and targeted therapeutic interventions. Continued research and innovation in this field will pave the way for the clinical implementation of PDEVs in the treatment of various diseases, offering new hope for more effective and sustainable therapeutic options.
8.Reactive and Enzyme-activated Probe Strategies for Imaging Acute Kidney Injury
Ru-Long CHEN ; Ting-Fei XIE ; Jin-Xin ZHANG ; Jia-Ting CHEN ; Jie LI ; Peng-Fei ZHANG ; Ji-Hong CHEN ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(6):1622-1637
Acute kidney injury (AKI) is a prevalent and life-threatening clinical syndrome characterised by a rapid decline in renal function and diverse pathological etiologies. The condition has been demonstrated to be associated with elevated mortality rates and an increased risk of progression to chronic kidney disease. At present, clinicians depend heavily on conventional functional markers, such as serum creatinine and urine output, for the diagnosis and staging of the disease. It is evident that these conventional indicators characteristically manifest a considerable temporal delay and only undergo modification subsequent to considerable tissue damage. This severely restricts the timeframe for early detection and timely therapeutic intervention. Furthermore, standard markers fail to provide specific biological information regarding the underlying cellular injury mechanisms. The utilisation of advanced probe technologies in molecular imaging offers a robust alternative to overcome these inherent diagnostic limitations.This comprehensive review systematically evaluates recent progress in the design and application of two primary categories of molecular imaging tools for acute kidney disease, specifically reactive probes and enzyme-activated probes. Reactive probes are engineered to specifically interact with redox-active chemical species, including hydrogen peroxide, peroxynitrite, hypochlorous acid, and sulfur dioxide. Because oxidative stress constitutes a primary early event in acute renal tubular damage, these probes enable researchers and clinicians to visualize early cellular injury and radical accumulation well before global renal functional decline becomes evident. We discuss the application of these reactive probes across multiple imaging modalities including fluorescence imaging, magnetic resonance imaging (MRI), positron emission tomography (PET), and photoacoustic techniques. Photoacoustic imaging combines high spatial resolution with deep tissue penetration and has successfully demonstrated the ability to provide diagnostic alerts up to 12 h before any detectable rise in serum creatinine levels. Additionally, specific reactive probes have shown promising translational potential when tested by high-throughput screening in clinical human urine samples. Enzyme-activated probes target the specific catalytic activity of disease-relevant enzymes. These include well-documented renal tubular structural biomarkers such as NAG, GGT, and ALP, along with apoptosis-related caspases and specific nitroreductases. By responding only to enzymatic cleavage, these tools provide highly specific and pathology-directed imaging readouts. Recent structural design strategies in this field have advanced significantly beyond single-enzyme detection. Researchers are now focusing on sophisticated dual-target recognition to minimize background noise, multimodal integration to cross-validate imaging signals, and theranostic applications where probes simultaneously deliver diagnostic feedback and therapeutic agents to injured tissues. Nanotechnology serves as a fundamental enabler for realizing these advanced probe functions. By precisely optimizing nanoparticle parameters such as hydrodynamic size, surface charge, and targeting ligands, researchers can achieve amplified signal output, highly precise kidney delivery, and protection against premature degradation in the systemic circulation. For example, modifying surface charges can significantly enhance the active uptake of nanoprobes by damaged renal tubular epithelial cells.While preclinical probe development has progressed rapidly, moving these technologies into routine clinical practice remains a major challenge. We analyze the translational feasibility and current obstacles from biological, technological, and regulatory perspectives. Although biological targets such as KIM-1, FAP, and ALP have been validated in extensive patient cohorts, practical barriers severely limit their immediate clinical application. These obstacles involve complex changes in in vivo pharmacokinetics. During an acute injury episode, the extreme drop in the glomerular filtration rate alters probe clearance and can cause unwanted systemic accumulation or confusing background imaging signals. Other major hurdles include a lack of comprehensive long-term toxicity data and the absence of standardized manufacturing protocols to ensure batch-to-batch consistency. Future successful translation will require rigorous multi-center clinical studies to confirm the true diagnostic value of these probes over traditional markers. Researchers must also establish strict standardization of imaging procedures and comprehensive safety evaluations. Ultimately, this review provides a thorough reference framework for designing clinically translatable molecular probes and building a precision diagnostic imaging system for acute kidney injury.
9.5G remote robot-assisted thoracoscopic lobectomy/segmentectomy for ten patients
Fan SHEN ; Jia HUANG ; Yu TIAN ; Hanbo PAN ; Jiantao LI ; Long JIANG ; Hong GUO ; Bentong YU ; Qingquan LUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(06):908-912
Objective To explore the safety and feasibility of 5G remote robot-assisted thoracoscopic anatomic lobectomy and segmentectomy. Methods A retrospective analysis was conducted on patients who underwent 5G remote robot-assisted thoracoscopic anatomic lobectomy or segmentectomy between July and September 2024. The surgeries were performed collaboratively by Shanghai Chest Hospital, Affiliated Hospital of Yangzhou University, and The First Affiliated Hospital of Nanchang University. Perioperative outcomes were recorded and analyzed. Results Ten patients were included, comprising 4 anatomic lobectomies and 6 segmentectomies. The median age was 61.0 (56.0, 72.0) years. The median intraoperative bi-directional network latency was 52.5 (39.0, 54.0) ms. There were no instances of network interruption, robot-related adverse events, or conversions to open thoracotomy. The median postoperative chest tube drainage volume was 500.0 (375.0, 600.0) mL, and the median hospital stay was 5.5 (4.0, 6.0) days. No complications of Clavien-Dindo grade Ⅱor higher occurred. All patients were recurrence-free and alive during the 6-month postoperative follow-up period. Conclusion 5G remote robot-assisted thoracoscopic surgery demonstrates high safety and operational stability. This technology shows promising potential for clinical application and is worthy of further development and utilization.
10.Population composition and seasonal distribution of mosquitoes in Laoshan District, Qingdao City
Zi-long TANG ; Na YU ; Yang YU ; Fan YIN ; Bing-hui LI ; Hong-yu WANG ; Ke-jia HUANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):114-120
Objective The study aimed to elucidate the population composition and seasonal distribution characteristics of mosquitoes in Laoshan District, Qingdao City, providing a scientific basis for the prevention and control of mosquito-borne infectious diseases. Methods Mosquito surveillance was conducted in Laoshan District in Qingdao City using light traps from April to November 2020-2022. Dominant mosquito species were identified using the Berger-Parker dominance index(I)and mosquito density was compared using the Kruskal-Wallis H test. The seasonal distribution characteristics of adult mosquitoes were analyzed using concentration and circular distribution method. Spearman rank correlation analysis was used to study the relationship between mosquito populations and meteorological factors with mean monthly temperature, mean monthly relative humidity, and mean monthly rainfall. Results The mean mosquito density for the trapping period was 9.771 females/(trap·night)in 2020,9.771 in 2021, and 9.427 in 2022. There was no statistically significant difference in mosquito density between different years(H = 0.095, P = 0.954). In total, 2 781 adult female mosquitoes comprising five species from four genera were captured over three years. Culex pipiens(I = 0.654), Aedes albopictus(I = 0.202), and Aedes aegypti(I = 0.118)were identified as dominant species. Seasonal fluctuations in the adult mosquitoes were unimodal, and primarily concentrated from June to September. The peak period of adult mosquito varied between years with statistical significance. (F = 3.838, P < 0.05). Mosquito density was highly correlated with mean monthly temperature, mean monthly relative humidity and mean monthly precipitation(P< 0.05). Conclusions Cx. pipiens pallens, Ae. albopictus, and Ar. inamoratus are the dominant mosquito species in the Laoshan District of Qingdao City. The activity of adult mosquitoes is seasonal, and primarily concentrated in summer and autumn, during which the risk of mosquito-borne diseases such as dengue fever is increased.


Result Analysis
Print
Save
E-mail