1.Medical Radiation Safety:Are We Doing It Right?
Journal of the Korean Society of Radiology 2024;85(6):1020-1034
In 2023, Korea had 104953 diagnostic radiological devices installed across 43529 medical institutions, with 398947394 examinations performed. The number of devices and examinations rank among the highest by OECD standards. The average medical radiation dose per individual was 3.13 mSv, representing an increase of approximately 27.2% compared to 2020, contrary to the global trend of decreasing radiation exposure. This study aimed to review various research activities by the Korean Society of Radiology, its members, and other researchers to reduce radiation exposure and explore additional strategies to further mitigate this issue.
2.Medical Radiation Safety:Are We Doing It Right?
Journal of the Korean Society of Radiology 2024;85(6):1020-1034
In 2023, Korea had 104953 diagnostic radiological devices installed across 43529 medical institutions, with 398947394 examinations performed. The number of devices and examinations rank among the highest by OECD standards. The average medical radiation dose per individual was 3.13 mSv, representing an increase of approximately 27.2% compared to 2020, contrary to the global trend of decreasing radiation exposure. This study aimed to review various research activities by the Korean Society of Radiology, its members, and other researchers to reduce radiation exposure and explore additional strategies to further mitigate this issue.
3.Medical Radiation Safety:Are We Doing It Right?
Journal of the Korean Society of Radiology 2024;85(6):1020-1034
In 2023, Korea had 104953 diagnostic radiological devices installed across 43529 medical institutions, with 398947394 examinations performed. The number of devices and examinations rank among the highest by OECD standards. The average medical radiation dose per individual was 3.13 mSv, representing an increase of approximately 27.2% compared to 2020, contrary to the global trend of decreasing radiation exposure. This study aimed to review various research activities by the Korean Society of Radiology, its members, and other researchers to reduce radiation exposure and explore additional strategies to further mitigate this issue.
4.Colon cancer: the 2023 Korean clinical practice guidelines for diagnosis and treatment
Hyo Seon RYU ; Hyun Jung KIM ; Woong Bae JI ; Byung Chang KIM ; Ji Hun KIM ; Sung Kyung MOON ; Sung Il KANG ; Han Deok KWAK ; Eun Sun KIM ; Chang Hyun KIM ; Tae Hyung KIM ; Gyoung Tae NOH ; Byung-Soo PARK ; Hyeung-Min PARK ; Jeong Mo BAE ; Jung Hoon BAE ; Ni Eun SEO ; Chang Hoon SONG ; Mi Sun AHN ; Jae Seon EO ; Young Chul YOON ; Joon-Kee YOON ; Kyung Ha LEE ; Kyung Hee LEE ; Kil-Yong LEE ; Myung Su LEE ; Sung Hak LEE ; Jong Min LEE ; Ji Eun LEE ; Han Hee LEE ; Myong Hoon IHN ; Je-Ho JANG ; Sun Kyung JEON ; Kum Ju CHAE ; Jin-Ho CHOI ; Dae Hee PYO ; Gi Won HA ; Kyung Su HAN ; Young Ki HONG ; Chang Won HONG ; Jung-Myun KWAK ;
Annals of Coloproctology 2024;40(2):89-113
Colorectal cancer is the third most common cancer in Korea and the third leading cause of death from cancer. Treatment outcomes for colon cancer are steadily improving due to national health screening programs with advances in diagnostic methods, surgical techniques, and therapeutic agents.. The Korea Colon Cancer Multidisciplinary (KCCM) Committee intends to provide professionals who treat colon cancer with the most up-to-date, evidence-based practice guidelines to improve outcomes and help them make decisions that reflect their patients’ values and preferences. These guidelines have been established by consensus reached by the KCCM Guideline Committee based on a systematic literature review and evidence synthesis and by considering the national health insurance system in real clinical practice settings. Each recommendation is presented with a recommendation strength and level of evidence based on the consensus of the committee.
5.Surgical Strategies for Partial Breast Reconstruction in Medial-Located Breast Cancer: A 12-Year Experience
Myeong Jae KANG ; Hyun Ki HONG ; Pil Seon EO ; Joon Seok LEE ; Jeong Woo LEE ; Jeeyeon LEE ; Ho Yong PARK ; Jung Dug YANG
Journal of Breast Cancer 2023;26(1):35-45
Purpose:
Partial breast reconstruction is challenging in medially located breast cancer, particularly in terms of achieving satisfactory aesthetic coverage. Thus, we aimed to investigate surgical strategies for filling medial defects resulting from breast-conserving surgery to improve patient satisfaction and aesthetic outcomes.
Methods:
We retrospectively evaluated 113 patients (114 cases) with medially located breast cancer between 2007 and 2018. We analysed the patient data, such as breast size, specimen weight, complications, and aesthetic results obtained using a questionnaire.
Results:
The mean body mass index and specimen weight were 23.43 kg/m2 (range, 18.5–26.8) and 83.29 g (range, 15–290 g), respectively. The tennis racket and round-block techniques were chosen for small defects (< 10%–15%) in small- and medium-sized breasts.The rotational and perforator flap techniques were used for medium-sized defects. The latissimus dorsi (LD) flap technique was used for large defects (> 30%). Hematoma was found in 1 case (0.96%), linear skin necrosis was found in 1 case (0.96%), seroma in the LD flaps was found in 8 cases (7.69%); fat necrosis in the rotational flaps was found in 2 cases (1.92%); and fat necrosis in an anterior intercostal artery perforator flap was found in 1 case (0.96%). 91 patients (87.5%) were satisfied with the aesthetic results.
Conclusion
The techniques used in this study for medially located breast cancer can produce fine aesthetic outcomes with regard to breast size and resection volume, with few complications.
6.Incidence of adverse drug reaction among 6 iodinated contrast media
Eunsil KOH ; Yu Jin KIM ; Noeul KANG ; Seong-Rye JIN ; Jin-Young LEE ; Hong EO ; Dong-Chull CHOI ; Byung-Jae LEE
Allergy, Asthma & Respiratory Disease 2021;9(2):84-92
Purpose:
Contrast media is one of the most common cause of adverse drug reaction (ADR) in adult. However, there was little data reported about differences in ADR ratio and severity among iodinated contrast media (ICM).
Methods:
Medical records of 627,049 patients who performed computed tomography scan using low-osmolar nonionic iodinated contrast media from January 2015 to December 2018 were retrospectively reviewed. A total of 6 ICMs including iomeprol, iohexol, iopromide, iobitridol, ioversol, and iopamidol were used in this period. The incidence of ADR was compared to their total usage and dosage between each contrast media.
Results:
The incidence of ADR of iopromide (1.36%) and iomeprol (1.27%) was the highest when compared with the average incidence of 1% of 6 ICMs. Ioversol (0.67%), iohexol, and iobitridol (0.74%) had the lower incidence of ADR. The order of results adjusted by actual administered dosage, the use of premedication, and the prior exposure history of ICMs was similar. The fraction of moderate and severe ADR in overall ADR was slightly different, but not proportional to the incidence of ADR.
Conclusion
The incidence of ADR among 6 low-osmolar nonionic ICMs was significantly different when compared by the total number of usage and the total volume of dose. The incidence of ADR varied by nearly 2-fold depending on ICMs. Further study might need to explore the reason for the difference of incidence.
7.Diagnostic Imaging for Physical Abuse in Children
Tae Yeon JEON ; So-Young YOO ; Hong EO ; Ji Hye KIM
Journal of the Korean Radiological Society 2020;81(4):832-851
Physical abuse is a significant cause of morbidity and mortality in the pediatric population. Young children, particularly in the first year of life, are most vulnerable to physical abuse. To evaluate suspected physical abuse, radiologists play a vital role by detecting radiological findings suggestive of physical abuse and differentiating them from other pathologies. This review focuses on radiologic findings, including those for fractures, abusive head trauma, spinal injury, and thoracoabdominal injury, commonly discovered in physically abused children, with special emphasis on biomechanical forces that produce injuries.
8.KSNM/KSID/KOSHIC Guidance for Nuclear Medicine Department Against the Coronavirus Disease 2019 (COVID-19) Pandemic
Ji-In BANG ; Ho-Young LEE ; Young Seok CHO ; Hongyoon CHOI ; Ari CHONG ; Jae Sun EO ; Ji Young KIM ; Tae Sung KIM ; Hyun-Woo KWON ; Eun Jeong LEE ; Eun Seong LEE ; Hye Lim PARK ; Soo Bin PARK ; Hye-kyung SHIM ; Bong-Il SONG ; Ik Dong YOO ; Kyung Jae LEE ; Hong Jae LEE ; Su Ha HAN ; Jin Seo LEE ; Jung Mi PARK ; Sung Hoon KIM
Nuclear Medicine and Molecular Imaging 2020;54(4):163-167
The dramatic spread of Coronavirus Disease 2019 (COVID-19) has profound impacts on every continent and life. Due to humanto-human transmission of COVID-19, nuclear medicine staffs also cannot escape the risk of infection from workplaces. Everystaff in the nuclear medicine department must prepare for and respond to COVID-19 pandemic which tailored to the characteristicsof our profession. This article provided the guidance prepared by the Korean Society of Nuclear Medicine (KSNM) incooperation with the Korean Society of Infectious Disease (KSID) and Korean Society for Healthcare-Associated InfectionControl and Prevention (KOSHIC) in managing the COVID-19 pandemic for the nuclear medicine department.We hope that thisguidance will support every practice in nuclear medicine during this chaotic period.
9.Recent Survey of Effective Doses of F-18 FDG Torso PET/CT in Korea and the Current Recommendations for CT Protocols of PET/CT
Ari CHONG ; Jung Mi PARK ; Kyoungjune PAK ; Yong-il KIM ; Hyun Woo KWON ; Eun Seong LEE ; Ki Pyo NAM ; Ho-Young LEE ; Hong Jae LEE ; Ik Dong YOO ; Jae Seon EO ; Ji Young KIM ; Joon-Kee YOON ; Kyeong Min KIM ; Seong Min KIM ; Tae-Sung KIM ; ;
Nuclear Medicine and Molecular Imaging 2020;54(5):224-232
Purpose:
This study aimed to construct a database of the effective doses (ED) from F-18 fluorodeoxyglucose (FDG) torso positron emission tomography/computed tomography (PET/CT) in Korea to provide data that supports the reduction of the CT dose of PET/CT and optimization of PET/CT protocols in Korea.
Methods:
We investigated data of ED and CT parameters of FDG PET/CT. The data were analyzed by body weight groups.
Results:
A total of 31 hospitals participated in the survey (99 adults). The mean total EDs (± SD) were 8.77 ± 2.76, 10.93 ± 3.14, and 12.57 ± 3.79 mSv for the 55-, 70-, and 85-kg groups, respectively. The FDG EDs were 4.80 ± 0.98, 6.05 ± 1.15, and 6.89 ± 1.52 mSv, and the CT EDs were 4.00 ± 2.12, 4.88 ± 2.51, and 5.68 ± 2.89 mSv, respectively. Of the enrolled hospitals, 54.5% used ultra-low-dose CT protocols, and their CT ED was significantly lower than low-dose CT group in all groups (2.9 ± 1.0, 3.2 ± 1.1, and 3.3 ± 1.0 mSv vs. 6.6 ± 1.6, 7.2 ± 2.1, and 7.9 ± 2.2 mSv, all p < 0.001, respectively). In the ultra-low-dose CT group, the CT ED with the iterative reconstruction was significantly lower than that of CT without iterative reconstruction in the 55-kg group (2.4 ± 0.9 vs. 3.3 ± 0.9, p = 0.04).
Conclusions
These results and current recommendations can be helpful for optimizing PET/CT diagnostic reference level (DRL) and reducing unnecessary PET/CT radiation exposure.
10.Delayed formation of sterile abscess after zygomaticomaxillary complex fracture treatment with bioabsorbable plates.
GyeongHyeon DOH ; Sujin BAHK ; Ki Yong HONG ; SooA LIM ; Kang Min HAN ; SuRak EO
Archives of Craniofacial Surgery 2018;19(2):143-147
We present a patient who showed a sterile abscess after facial bone fixation with bioabsorbable plates and screws. He had zygomaticomaxillary complex and periorbital fracture due to falling down. The displaced bones were treated by open reduction and internal fixation successfully using bioabsorbable plate system. However, at postoperative 11 months, abrupt painless swelling was noted on the previous operation sites, left lateral eyebrow and lower eyelid. By surgical exploration, pus-like discharge and degraded materials were observed and debrided. The pathologic analysis revealed foreign body reaction with sterile abscess. This complication followed by bioabsorbable device implantation on maxillofacial bone surgery has been rarely reported in which we call attention to the maxillofacial plastic surgeons.
Abscess*
;
Absorbable Implants
;
Accidental Falls
;
Eyebrows
;
Eyelids
;
Facial Bones
;
Foreign-Body Reaction
;
Humans
;
Plastics
;
Surgeons