1.Quality evaluation of Qingwen hufei granules based on fingerprints combined with multi-component content determination
Huiying ZHOU ; Yuan WANG ; Yani WANG ; Yun YANG ; Bo WANG ; Shuanzhu YANG ; Liping CAO ; Hong ZHANG ; Kaihua LONG
China Pharmacy 2026;37(3):338-343
OBJECTIVE To provide a scientific basis for the quality evaluation and clinical application of Qingwen hufei granules. METHODS Fourteen batches of Qingwen hufei granules were used as samples to establish high-performance liquid chromatography (HPLC) fingerprints using the Similarity Evaluation System for Chromatographic Fingerprint of Traditional Chinese Medicine (2012 Edition). The chromatographic peaks were identified and the similarity was evaluated. Cluster analysis (CA), principal component analysis (PCA), and orthogonal partial least squares-discriminant analysis (OPLS-DA) were used to conduct chemical pattern recognition analysis on the 14 batches of samples. Meanwhile, the contents of neochlorogenic acid (NGA), chlorogenic acid (CHA), cryptochlorogenic acid (CGA), forsythoside A (FTA), 3,5-O-dicaffeoylquinic acid (3,5-O- DA), 4,5-O-dicaffeoylquinic acid (4,5-O-DA), and angoroside C (AGC) in the samples were determined by HPLC. RESULTS The methodological investigation results of both the fingerprint and the content determination complied with the relevant requirements. Fourteen common peaks were indicated in the HPLC fingerprints of the 14 batches of samples, and 7 of them were identified [NGA (peak 2), CHA (peak 3), CGA (peak 5), FTA (peak 11), 3,5-O-DA (peak 12), 4,5-O-DA (peak 13), and AGC (peak 14)]; the similarity of each sample was greater than 0.94. The results of CA and PCA showed that the samples could be classified into 3 categories; the results of OPLS-DA indicated that peak 4 (unknown), peak 11 (FTA), peak 8 (unknown), peak 9 (unknown), and peak 1 (unknown) were the differential components. The content ranges of NGA, CHA, CGA, 3,5-O-DA, FTA, 4,5-O-DA and AGC in the 14 batches of samples were 0.210 4-0.458 7, 0.269 1-0.506 3, 0.228 1-0.461 1, 0.443 9-1.044 6, 0.066 7-0.155 7, 0.062 8-0.143 8, and 0.057 4-0.105 7 mg/g, respectively. CONCLUSIONS The HPLC fingerprint and multi-component content determination methods established in this study are efficient and reliable, and can be used for the quality evaluation of Qingwen hufei granules.
2.A Case Report of Pachydermoperiostosis by Multidisciplinary Diagnosis and Treatment
Jie ZHANG ; Yan ZHANG ; Li HUO ; Ke LYU ; Tao WANG ; Ze'nan XIA ; Xiao LONG ; Kexin XU ; Nan WU ; Bo YANG ; Weibo XIA ; Rongrong HU ; Limeng CHEN ; Ji LI ; Xia HONG ; Yan ZHANG ; Yagang ZUO
JOURNAL OF RARE DISEASES 2025;4(1):75-82
A 20-year-old male patient presented to the Department of Dermatology of Peking Union Medical College Hospital with complaints of an 8-year history of facial scarring, swelling of the lower limbs, and a 4-year history of scalp thickening. Physical examination showed thickening furrowing wrinkling of the skin on the face and behind the ears, ciliary body hirsutism, blepharoptosis, and cutis verticis gyrate. Both lower limbs were swollen, especially the knees and ankles. The skin of the palms and soles of the feet was keratinized and thickened. Laboratory examination using bone and joint X-ray showed periostosis of the proximal middle phalanges and metacarpals of both hands, distal ulna and radius, tibia and fibula, distal femurs, and metatarsals.Genetic testing revealed two variants in
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Changes and Trends in the microbiological-related standards in the Chinese Pharmacopoeia 2025 Edition
FAN Yiling ; ZHU Ran ; YANG Yan ; JIANG Bo ; SONG Minghui ; WANG Jing ; LI Qiongqiong ; LI Gaomin ; WANG Shujuan ; SHAO Hong ; MA Shihong ; CAO Xiaoyun ; HU Changqin ; MA Shuangcheng, ; YANG Meicheng
Drug Standards of China 2025;26(1):093-098
Objective: To systematically analyze the revisions content and technological development trends of microbiological standards in the Chinese Pharmacopoeia (ChP) 2025 Edition, and explore its novel requirements in risk-based pharmaceutical product lifecycle management.
Methods: A comprehensive review was conducted on 26 microbiological-related standards to summarize the revision directions and scientific implications from perspectives including the revision overview, international harmonization of microbiological standards, risk-based quality management system, and novel tools and methods with Chinese characteristics.
Results: The ChP 2025 edition demonstrates three prominent features in microbiological-related standards: enhanced international harmonization, introduced emerging molecular biological technologies, and established a risk-based microbiological quality control system.
Conclusion: The new edition of the Pharmacopoeia has systematically constructed a microbiological standard system, which significantly improves the scientificity, standardization and applicability of the standards, providing a crucial support for advancing the microbiological quality control in pharmaceutical industries of China.
8.Comparative analysis of isolated male epispadias: concealed versus nonconcealed cases in a Chinese tertiary hospital.
Jia-Yi LI ; Bo YU ; Meng-Cheng YANG ; Zong-Han LI ; Hong-Cheng SONG ; Wei-Ping ZHANG
Asian Journal of Andrology 2025;27(4):502-507
Isolated male epispadias typically presents with preputial defects and dorsal urethral dehiscence. A less common subtype, known as concealed epispadias, is distinguished by an intact prepuce. Despite its clinical relevance, there is limited literature on this variant. In this study, we retrospectively analyzed the clinical data of 86 pediatric patients with isolated male epispadias treated in Beijing Children's Hospital (Beijing, China) from May 2004 to July 2023, including 19 cases of concealed epispadias and 67 of nonconcealed epispadias. We compared clinical characteristics, preoperative diagnostics, surgical techniques, postoperative outcomes, and sexual function during follow-up between the concealed and nonconcealed groups. No significant differences were observed between the two groups regarding surgical methods, postoperative complications, or rates of urinary incontinence. However, notable distinctions were found in the age at initial diagnosis, timing of surgery, frequency of incontinence, location of the urethral meatus, and postoperative urinary incontinence scores (all P < 0.05). Given the absence of penopubic epispadias in concealed cases, we categorized glans and penile epispadias within nonconcealed epispadias as distal epispadias ( n = 40) and subsequently compared them with concealed epispadias cases. The postoperative urinary incontinence scores did not differ significantly between the concealed and distal epispadias groups. These findings suggest that concealed epispadias represents a relatively milder form of the condition, characterized by the absence of penopubic involvement, lower rates of urinary incontinence, and favorable surgical outcomes. However, the intact prepuce in concealed cases underscores the need for careful identification and early diagnosis.
Humans
;
Male
;
Retrospective Studies
;
Epispadias/classification*
;
China
;
Tertiary Care Centers
;
Child, Preschool
;
Child
;
Postoperative Complications/epidemiology*
;
Urinary Incontinence/epidemiology*
;
Urethra/surgery*
;
Infant
;
Penis/surgery*
;
Adolescent
;
Urologic Surgical Procedures, Male/methods*
;
East Asian People
9.Association between insulin resistance and uterine volume in girls with idiopathic central precocious puberty.
Hong-Ru ZHANG ; Ya XIAO ; Shu-Qin JIANG ; Jun SUN ; Wen-Hui SHI ; Jin-Bo LI ; Ying YANG ; Wei WANG
Chinese Journal of Contemporary Pediatrics 2025;27(4):404-409
OBJECTIVES:
To investigate the association between insulin resistance and uterine volume in girls with idiopathic central precocious puberty (ICPP).
METHODS:
A retrospective study was conducted involving 61 girls diagnosed with ICPP who visited the pediatric growth and development clinic of the Third Affiliated Hospital of Zhengzhou University between January 2022 and September 2024, designated as the ICPP group, and 61 normally developing girls as the control group. The differences in insulin resistance index (homeostasis model assessment of insulin resistance, HOMA-IR), uterine volume, and other indicators between the two groups were compared, and the relationship between insulin resistance and uterine volume in these girls was analyzed.
RESULTS:
The uterine volume and HOMA-IR level in the ICPP group were significantly higher than those in the control group (P<0.05). Correlation analysis revealed that there was a positive correlation between HOMA-IR level and uterine volume in the ICPP group (rs=0.643, P<0.001). Multiple linear regression analysis indicated that as HOMA-IR increased,uterine volume in the girls tended to increase (P<0.05).
CONCLUSIONS
There is an association between insulin resistance and uterine volume in girls with ICPP, and as HOMA-IR increases, uterine volume in the girls also increases.
Humans
;
Female
;
Insulin Resistance
;
Puberty, Precocious/metabolism*
;
Uterus/pathology*
;
Child
;
Retrospective Studies
;
Organ Size
;
Linear Models
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail