1.Prognostic significance of TRIM28 elevation in non-M3 acute myeloid leukemia
Siqi GONG ; Cong LI ; Mengmeng FAN ; Huiping WANG ; Wanqiu ZHANG ; Xue LIANG ; Qianshan TAO ; Qiang HONG ; Zhimin ZHAI
Acta Universitatis Medicinalis Anhui 2026;61(2):301-308
ObjectiveTo clarify the expression of TRIM28 in non-M3 acute myeloid leukemia (AML) and its correlation with clinical indicators and prognosis, and to further explore the effect of TRIM28 expression levels on the proliferation and apoptosis of AML cells using small interfering RNA. MethodsThe GSE34577 dataset was analyzed using R software to compare TRIM28 expression between healthy controls and non-M3 acute myeloid leukemia (AML) patients. Clinical samples from non-M3 AML patients were collected, with TRIM28 expression levels measured using real-time quantitative PCR (qPCR). The analysis focused on correlations between TRIM28 expression and various clinical indicators, treatment efficacy, and patient prognosis. Furthermore, small interfering RNA (siRNA) technology was employed to downregulate TRIM28 expression in human primary AML cells (HL60 cell line). The effects on cell proliferation and apoptosis were then assessed through CCK-8 assays and flow cytometry, respectively. ResultsThe results showed that TRIM28 was up-regulated in non-M3 AML of both online database GSE34577 and clinical samples (P<0.000 1), TRIM28 expression of new diagnosis group and relapsed refractory group was higher than iron deficiency anemia group (P<0.01), and there was no significance between different French-American-British classification systems subtype. TRIM28 expression was higher in non-M3 AML patients with a poor genetic prognosis stratified as moderate than in the good prognosis group, and TRIM28 expression was associated with NPM1 combined with the FLT3-ITD mutation, positively correlated with age, bone marrow blast, peripheral blood blast and white blood cell, negatively correlated with hemoglobin. In addition, interference TRIM28 greatly inhibited cell proliferation and promoted cell apoptosis. ConclusionThis study reveals that TRIM28 is highly expressed in non-M3 AML and associated with prognosis, and plays a key role in the proliferation and apoptosis of AML cells, suggesting that TRIM28 may serve as a novel therapeutic target for non-M3 AML.
2.Status and correlations of psychological distress, job satisfaction, and sleep quality among prehospital emergency medical personnel in Guangzhou
Jiarui LIANG ; Huilin JIANG ; Baoling WU ; Hanxiang GONG ; Jiangli WU ; Tongtong DENG ; Zhengyu CHEN ; Xiaohui CHEN
Journal of Environmental and Occupational Medicine 2026;43(5):614-620
Background Prehospital emergency medical personnel (PEMP) are exposed to long-term high-pressure work, which can exacerbate psychological distress and impair job satisfaction and sleep quality. However, in-depth research on the interactions among these factors is lacking. Objective To assess the status of psychological distress, job satisfaction, and sleep quality of PEMP in Guangzhou and to explore the mediating role of sleep quality in the relationship between psychological distress and job satisfaction. Methods From February to May 2025, 1085 PEMP from "120" emergency network hospitals in Guangzhou were selected using convenience sampling. Data were collected via the General Information Questionnaire, Kessler Psychological Distress Scale, Minnesota Satisfaction Questionnaire, and Pittsburgh Sleep Quality Index. Statistical analyses were performed using SPSS 25.0, and The mediation model of sleep quality in linking psychological distress and job satisfaction was constructed using AMOS 28.0. The bias-corrected Bootstrap method was employed to assessed the significance of the mediating effect. Results A total of 1063 valid responses were received (97.97% valid response rate). The mean scores were: psychological distress (27.99±10.75), job satisfaction (69.45±15.84), and sleep quality (9.82±4.47). Significant differences in the three scores were found across gender, age, monthly night shift frequency, and hospital grade (P<0.05). Higher job satisfaction was linked to lower psychological distress and better sleep quality and its dimensions, while psychological distress directly correlated with poorer sleep quality (P<0.01). Sleep quality partially mediated the relationship between psychological distress and job satisfaction, with a mediating effect of −0.195, accounting for 43.62% of the total effect. Conclusion The participants report moderate psychological distress, moderate-to-high job satisfaction, and poor sleep quality. Psychological distress directly affects job satisfaction and indirectly through its impact on sleep quality. Interventions aimed at improving sleep health and mental health are essential to improve personnel well-being and work efficiency.
3.Status and correlations of psychological distress, job satisfaction, and sleep quality among prehospital emergency medical personnel in Guangzhou
Jiarui LIANG ; Huilin JIANG ; Baoling WU ; Hanxiang GONG ; Jiangli WU ; Tongtong DENG ; Zhengyu CHEN ; Xiaohui CHEN
Journal of Environmental and Occupational Medicine 2026;43(5):614-620
Background Prehospital emergency medical personnel (PEMP) are exposed to long-term high-pressure work, which can exacerbate psychological distress and impair job satisfaction and sleep quality. However, in-depth research on the interactions among these factors is lacking. Objective To assess the status of psychological distress, job satisfaction, and sleep quality of PEMP in Guangzhou and to explore the mediating role of sleep quality in the relationship between psychological distress and job satisfaction. Methods From February to May 2025, 1085 PEMP from "120" emergency network hospitals in Guangzhou were selected using convenience sampling. Data were collected via the General Information Questionnaire, Kessler Psychological Distress Scale, Minnesota Satisfaction Questionnaire, and Pittsburgh Sleep Quality Index. Statistical analyses were performed using SPSS 25.0, and The mediation model of sleep quality in linking psychological distress and job satisfaction was constructed using AMOS 28.0. The bias-corrected Bootstrap method was employed to assessed the significance of the mediating effect. Results A total of 1063 valid responses were received (97.97% valid response rate). The mean scores were: psychological distress (27.99±10.75), job satisfaction (69.45±15.84), and sleep quality (9.82±4.47). Significant differences in the three scores were found across gender, age, monthly night shift frequency, and hospital grade (P<0.05). Higher job satisfaction was linked to lower psychological distress and better sleep quality and its dimensions, while psychological distress directly correlated with poorer sleep quality (P<0.01). Sleep quality partially mediated the relationship between psychological distress and job satisfaction, with a mediating effect of −0.195, accounting for 43.62% of the total effect. Conclusion The participants report moderate psychological distress, moderate-to-high job satisfaction, and poor sleep quality. Psychological distress directly affects job satisfaction and indirectly through its impact on sleep quality. Interventions aimed at improving sleep health and mental health are essential to improve personnel well-being and work efficiency.
4.Diagnostic value of exhaled volatile organic compounds in pulmonary cystic fibrosis: A systematic review
Xiaoping YU ; Zhixia SU ; Kai YAN ; Taining SHA ; Yuhang HE ; Yanyan ZHANG ; Yujian TAO ; Hong GUO ; Guangyu LU ; Weijuan GONG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(02):223-229
Objective To explore the diagnostic value of exhaled volatile organic compounds (VOCs) for cystic fibrosis (CF). Methods A systematic search was conducted in PubMed, EMbase, Web of Science, Cochrane Library, CNKI, Wanfang, VIP, and SinoMed databases up to August 7, 2024. Studies that met the inclusion criteria were selected for data extraction and quality assessment. The quality of included studies was assessed by the Newcastle-Ottawa Scale (NOS), and the risk of bias and applicability of included prediction model studies were assessed by the prediction model risk of bias assessment tool (PROBAST). Results A total of 10 studies were included, among which 5 studies only identified specific exhaled VOCs in CF patients, and another 5 developed 7 CF risk prediction models based on the identification of VOCs in CF. The included studies reported a total of 75 exhaled VOCs, most of which belonged to the categories of acylcarnitines, aldehydes, acids, and esters. Most models (n=6, 85.7%) only included exhaled VOCs as predictive factors, and only one model included factors other than VOCs, including forced expiratory flow at 75% of forced vital capacity (FEF75) and modified Medical Research Council scale for the assessment of dyspnea (mMRC). The accuracy of the models ranged from 77% to 100%, and the area under the receiver operating characteristic curve ranged from 0.771 to 0.988. None of the included studies provided information on the calibration of the models. The results of the Prediction Model Risk of Bias Assessment Tool (PROBAST) showed that the overall bias risk of all predictive model studies was high, and the overall applicability was unclear. Conclusion The exhaled VOCs reported in the included studies showed significant heterogeneity, and more research is needed to explore specific compounds for CF. In addition, risk prediction models based on exhaled VOCs have certain value in the diagnosis of CF, but the overall bias risk is relatively high and needs further optimization from aspects such as model construction and validation.
5.Exon Sequencing of HNF1β in Chinese Patients with Early-Onset Diabetes
Siqian GONG ; Hong LIAN ; Yating LI ; Xiaoling CAI ; Wei LIU ; Yingying LUO ; Meng LI ; Si-min ZHANG ; Rui ZHANG ; Lingli ZHOU ; Yu ZHU ; Qian REN ; Xiuying ZHANG ; Jing CHEN ; Jing WU ; Xianghai ZHOU ; Xirui WANG ; Xueyao HAN ; Linong JI
Diabetes & Metabolism Journal 2025;49(2):321-330
Background:
Maturity-onset diabetes of the young (MODY) due to variants of hepatocyte nuclear factor 1-beta (HNF1β) (MODY5) has not been well studied in the Chinese population. This study aimed to estimate its prevalence and evaluate the application of a clinical screening method (Faguer score) in Chinese early-onset diabetes (EOD) patients.
Methods:
Among 679 EOD patients clinically diagnosed with type 2 diabetes mellitus (age at diagnosis ≤40 years), the exons of HNF1β were sequenced. Functional impact of rare variants was evaluated using a dual-luciferase reporter system. Faguer scores ≥8 prompted multiplex ligation-dependent probe amplification (MLPA) for large deletions. Pathogenicity of HNF1β variants was assessed following the American College of Medical Genetics and Genomics (ACMG) guidelines.
Results:
Two rare HNF1β missense mutations (E105K and G454R) were identified by sequencing in five patients, showing functional impact in vitro. Another patient was found to have a whole-gene deletion by MLPA in 22 patients with the Faguer score above 8. Following ACMG guidelines, six patients carrying pathogenic or likely pathogenic variant were diagnosed with MODY5. The estimated prevalence of MODY5 in Chinese EOD patients was approximately 0.9% or higher.
Conclusion
MODY5 is not uncommon in China. The Faguer score is helpful in deciding whether to perform MLPA analysis on patients with negative sequencing results.
6.Enzyme-directed Immobilization Strategies for Biosensor Applications
Xing-Bao WANG ; Yao-Hong MA ; Yun-Long XUE ; Xiao-Zhen HUANG ; Yue SHAO ; Yi YU ; Bing-Lian WANG ; Qing-Ai LIU ; Li-He ZHANG ; Wei-Li GONG
Progress in Biochemistry and Biophysics 2025;52(2):374-394
Immobilized enzyme-based enzyme electrode biosensors, characterized by high sensitivity and efficiency, strong specificity, and compact size, demonstrate broad application prospects in life science research, disease diagnosis and monitoring, etc. Immobilization of enzyme is a critical step in determining the performance (stability, sensitivity, and reproducibility) of the biosensors. Random immobilization (physical adsorption, covalent cross-linking, etc.) can easily bring about problems, such as decreased enzyme activity and relatively unstable immobilization. Whereas, directional immobilization utilizing amino acid residue mutation, affinity peptide fusion, or nucleotide-specific binding to restrict the orientation of the enzymes provides new possibilities to solve the problems caused by random immobilization. In this paper, the principles, advantages and disadvantages and the application progress of enzyme electrode biosensors of different directional immobilization strategies for enzyme molecular sensing elements by specific amino acids (lysine, histidine, cysteine, unnatural amino acid) with functional groups introduced based on site-specific mutation, affinity peptides (gold binding peptides, carbon binding peptides, carbohydrate binding domains) fused through genetic engineering, and specific binding between nucleotides and target enzymes (proteins) were reviewed, and the application fields, advantages and limitations of various immobilized enzyme interface characterization techniques were discussed, hoping to provide theoretical and technical guidance for the creation of high-performance enzyme sensing elements and the manufacture of enzyme electrode sensors.
7.Design and application of auto-review program for data records in radiotherapy
Yaling HONG ; Shijie LI ; Zhengxin GAO ; Yunfeng WU ; Qiaoying HU ; Shen FU ; Qing GONG ; Wei XIE
China Medical Equipment 2025;22(2):170-174
Objective:To develop and design a during-treatment records auto-review program to comply the quality assurance(QA)requirement of radiotherapy chart auditing,and thereby improve the review efficiency and accuracy.Methods:Based on the items the guideline required,the Aria Oncology Information System database backup files was analyzed by Java,Vue,and etc.languages and the corresponding review logic was formulated.A total of 530 treatment records generated at Shanghai Concord Cancer Center from January to March 2024(10 weeks)were auto-reviewed and compared with the manual results for evaluating the accuracy and efficiency of the program.Results:The auto-review program was running smoothly.Overall with the above data,the sensitivity,specificity,accuracy and the error-miss rate were 73.4%,14.3%,87.7%and 12.3%respectively.For sub-set items,the source-skin distance(SSD)error detecting rate was 100%,the wrong session reporting was 100%correlated with the plans switching and the wrong fraction reporting was 100%related to plan revision.For the other items,auto and manual reviews gave out the same accuracy.Conclusion:The none-error results from the program are all true,so the manual rechecking could limit to those auto-review error records,which can reduce the workload by 73.4%,therefore improve the effectiveness and accuracy of the radiotherapy data review.
8.Changing prevalence and antibiotic resistance profiles of carbapenem-resistant Enterobacterales in hospitals across China:data from CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Wenxiang JI ; Tong JIANG ; Jilu SHEN ; Yang YANG ; Fupin HU ; Demei ZHU ; Yuanhong XU ; Ying HUANG ; Fengbo ZHANG ; Ping JI ; Yi XIE ; Mei KANG ; Chuanqing WANG ; Pan FU ; Yingchun XU ; Xiaojiang ZHANG ; Ziyong SUN ; Zhongju CHEN ; Yuxing NI ; Jingyong SUN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Yunsong YU ; Jie LIN ; Bin SHAN ; Yan DU ; Sufang GUO ; Lianhua WEI ; Fengmei ZOU ; Yunjian HU ; Xiaoman AI ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Chao YAN ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanping ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Hong ZHANG ; Chun WANG ; Wenhui HUANG ; Ruizhong WANG ; Hua FANG ; Bixia YU ; Yong ZHAO ; Ping GONG ; Kaizhen WENG ; Yirong ZHANG ; Jiangshan LIU ; Longfeng LIAO ; Hongqin GU ; Lin JIANG ; Wen HE ; Shunhong XUE ; Jiao FENG ; Chunlei YUE
Chinese Journal of Infection and Chemotherapy 2025;25(4):445-454
Objective To summarize the changing prevalence of carbapenem resistance in Enterobacterales based on the data of CHINET Antimicrobial Resistance Surveillance Program from 2015 to 2021 for improving antimicrobial treatment in clinical practice.Methods Antimicrobial susceptibility testing was performed using a commercial automated susceptibility testing system according to the unified CHINET protocol.The results were interpreted according to the breakpoints of the Clinical & Laboratory Standards Institute(CLSI)M100 31st ed in 2021.Results Over the seven-year period(2015-2021),the overall prevalence of carbapenem-resistant Enterobacterales(CRE)was 9.43%(62 342/661 235).The prevalence of CRE strains in Klebsiella pneumoniae,Citrobacter freundii,and Enterobacter cloacae was 22.38%,9.73%,and 8.47%,respectively.The prevalence of CRE strains in Escherichia coli was 1.99%.A few CRE strains were also identified in Salmonella and Shigella.The CRE strains were mainly isolated from respiratory specimens(44.23±2.80)%,followed by blood(20.88±3.40)%and urine(18.40±3.45)%.Intensive care units(ICUs)were the major source of the CRE strains(27.43±5.20)%.CRE strains were resistant to all the β-lactam antibiotics tested and most non-β-lactam antimicrobial agents.The CRE strains were relatively susceptible to tigecycline and polymyxins with low resistance rates.Conclusions The prevalence of CRE strains was increasing from 2015 to 2021.CRE strains were highly resistant to most of the antibacterial drugs used in clinical practice.Clinicians should prescribe antimicrobial agents rationally.Hospitals should strengthen antibiotic stewardship in key clinical settings such as ICUs,and take effective infection control measures to curb CRE outbreak and epidemic in hospitals.
9.Changing distribution and antibiotic resistance profiles of the respiratory bacterial isolates in hospitals across China:data from CHINET Antimicrobial Resistance Surveillance Program,2015-2021
Ying FU ; Yunsong YU ; Jie LIN ; Yang YANG ; Fupin HU ; Demei ZHU ; Yingchun XU ; Xiaojiang ZHANG ; Fengbo ZHANG ; Ping JI ; Yi XIE ; Mei KANG ; Chuanqing WANG ; Pan FU ; Yuanhong XU ; Ying HUANG ; Ziyong SUN ; Zhongju CHEN ; Yuxing NI ; Jingyong SUN ; Yunzhuo CHU ; Sufei TIAN ; Zhidong HU ; Jin LI ; Bin SHAN ; Yan DU ; Sufang GUO ; Lianhua WEI ; Fengmei ZOU ; Hong ZHANG ; Chun WANG ; Yunjian HU ; Xiaoman AI ; Chao ZHUO ; Danhong SU ; Dawen GUO ; Jinying ZHAO ; Hua YU ; Xiangning HUANG ; Wen'en LIU ; Yanming LI ; Yan JIN ; Chunhong SHAO ; Xuesong XU ; Chao YAN ; Shanmei WANG ; Yafei CHU ; Lixia ZHANG ; Juan MA ; Shuping ZHOU ; Yan ZHOU ; Lei ZHU ; Jinhua MENG ; Fang DONG ; Zhiyong LÜ ; Fangfang HU ; Han SHEN ; Wanqing ZHOU ; Wei JIA ; Gang LI ; Jinsong WU ; Yuemei LU ; Jihong LI ; Jinju DUAN ; Jianbang KANG ; Xiaobo MA ; Yanping ZHENG ; Ruyi GUO ; Yan ZHU ; Yunsheng CHEN ; Qing MENG ; Shifu WANG ; Xuefei HU ; Jilu SHEN ; Ruizhong WANG ; Hua FANG ; Bixia YU ; Yong ZHAO ; Ping GONG ; Kaizhen WENG ; Yirong ZHANG ; Jiangshan LIU ; Longfeng LIAO ; Hongqin GU ; Lin JIANG ; Wen HE ; Shunhong XUE ; Jiao FENG ; Chunlei YUE ; Wenhui HUANG
Chinese Journal of Infection and Chemotherapy 2025;25(4):431-444
Objective To characterize the changing species distribution and antibiotic resistance profiles of respiratory isolates in hospitals participating in the CHINET Antimicrobial Resistance Surveillance Program from 2015 to 2021.Methods Commercial automated antimicrobial susceptibility testing systems and disk diffusion method were used to test the susceptibility of respiratory bacterial isolates to antimicrobial agents following the standardized technical protocol established by the CHINET program.Results A total of 589 746 respiratory isolates were collected from 2015 to 2021.Overall,82.6%of the isolates were Gram-negative bacteria and 17.4%were Gram-positive bacteria.The bacterial isolates from outpatients and inpatients accounted for(6.0±0.9)%and(94.0±0.1)%,respectively.The top microorganisms were Klebsiella spp.,Acinetobacter spp.,Pseudomonas aeruginosa,Staphylococcus aureus,Haemophilus spp.,Stenotrophomonas maltophilia,Escherichia coli,and Streptococcus pneumoniae.Each microorganism was isolated from significantly more males than from females(P<0.05).The overall prevalence of methicillin-resistant S.aureus(MRSA)was 39.9%.The prevalence of penicillin-resistant S.pneumoniae was 1.4%.The prevalence of extended-spectrum β-lactamase(ESBL)-producing E.coli and K.pneumoniae was 67.8%and 41.3%,respectively.The overall prevalence of carbapenem-resistant E.coli,K.pneumoniae,Enterobacter cloacae,Pseudomonas aeruginosa,and Acinetobacter baumannii was 3.7%,20.8%,9.4%,29.8%,and 73.3%,respectively.The prevalence of β-lactamase was 96.1%in Moraxella catarrhalis and 60.0%in Haemophilus influenzae.The H.influenzae isolates from children(<18 years)showed significantly higher resistance rates to β-lactam antibiotics than the isolates from adults(P<0.05).Conclusions Gram-negative bacteria are still predominant in respiratory isolates associated with serious antibiotic resistance.Antimicrobial resistance surveillance should be strengthened in clinical practice to support accurate etiological diagnosis and appropriate antimicrobial therapy based on antimicrobial susceptibility testing results.
10.The safety and efficacy of boron neutron capture therapy (BNCT) in the treatment of recurrent malignant tumors
Junqiang HONG ; Xiaoyi LIN ; Youqun LAI ; Ye CAO ; Xiangquan KONG ; Yuanhao LIU ; Shuiying LUO ; Zhicheng XIONG ; Mei GONG ; Yalai LIN ; Qiaoyun CHEN ; Mingang YING ; Li HUO ; Xiaohua ZHU ; Xiaoping SUN ; Yiqiao DENG ; Diyun SHU ; Haige ZHANG ; Cheng HUANG ; Jianji PAN
Chinese Journal of Radiation Oncology 2025;34(10):985-992
Objective:To evaluate the safety and efficacy of accelerator-based boron neutron capture therapy (AB-BNCT) in the treatment of recurrent and refractory malignant tumors.Methods:The data of 14 patients admitted to Xiamen Humanity Hospital from September 2022 to April 2023 were prospectively collected, including 7 patients with primary brain malignancies and 7 patients with locally recurrent inoperable head and neck malignancies. All patients received intravenous infusion of boron drug (NBB-001, p-dihydroxyborylphe nylalanine, a patented freeze-dried formulation) at a total nominal dosage of 500 mg/kg (11 patients) or 750 mg/kg (3 patients), and were irradiated with neutrons (operating with NeuPex system). Adverse events after treatment were recorded and assessed. The primary efficacy endpoint was the 90 d objective response rate (ORR), while the secondary endpoints included progression-free survival (PFS) and complete response rate (CRR). Data were compiled and analyzed by SAS 9.4 software. The rate and 95% CI were calculated using Clopper-Pearson method. Results:The median dose delivered to 80% of the target volume (D 80%) was 16.80 GyE (range: 8.93-23.79 GyE). The most common adverse reactions were hyperamylasemia, alopecia, and hyperprolactinemia. Five patients experienced 8 cases of grade 3 or above adverse events, including 1 case of grade 4 acute kidney injury and 7 cases of grade 3 adverse events. All adverse events were recovered after observation or treatment. At 90 d after treatment, the ORR of all patients was 9/14 (64%, 95% CI: 35%-87%), disease control rate (DCR) was 10/14 (71%, 95% CI: 42%-92%), CRR was 2/14 (14%, 95% CI: 2%-42%); and the best overall response during the entire course included an ORR of 10/14 (71% ,95% CI: 42%-92%), DCR of 13/14 (93%, 95% CI: 66%-100%), and CRR of 3/14 (21% ,95% CI: 5%-51%). The 1-year survival rate for head and neck malignancies was 71.4%, and the 2-year survival rate was 42.8%. The 1-year survival rate for recurrent brain malignancies was 42.8%. Conclusion:AB-BNCT demonstrates favorable safety and promising efficacy in treating primary brain malignancies and recurrent/refractory head and neck malignancies, representing a potential therapeutic option.

Result Analysis
Print
Save
E-mail