1.Association of Age, Sex and Education With Access to the Intravenous Thrombolysis for Acute Ischemic Stroke
Yoona KO ; Beom Joon KIM ; Youngran KIM ; Jong-Moo PARK ; Kyusik KANG ; Jae Guk KIM ; Jae-Kwan CHA ; Tai Hwan PARK ; Kyungbok LEE ; Jun LEE ; Keun-Sik HONG ; Byung-Chul LEE ; Kyung-Ho YU ; Dong-Eog KIM ; Joon-Tae KIM ; Jay Chol CHOI ; Jee Hyun KWON ; Wook-Joo KIM ; Kyu Sun YUM ; Sung-Il SOHN ; Hyungjong PARK ; Sang-Hwa LEE ; Kwang-Yeol PARK ; Chi Kyung KIM ; Sung Hyuk HEO ; Moon-Ku HAN ; Anjail Z. SHARRIEF ; Sunil A. SHETH ; Hee-Joon BAE ;
Journal of Korean Medical Science 2025;40(13):e49-
Background:
Barriers to treatment with intravenous thrombolysis (IVT) for patients with acute ischemic stroke (AIS) in South Korea remain incompletely characterized. We analyze a nationwide prospective cohort to determine patient-level features associated with delayed presentation and non-treatment of potential IVT-eligible patients.
Methods:
We identified consecutive patients with AIS from 01/2011 to 08/2023 from a multicenter and prospective acute stroke registry in Korea. Patients were defined as IVT candidates if they presented within 4.5 hours from the last known well, had no lab evidence of coagulopathy, and had National Institute of Health Stroke Scale (NIHSS) ≥ 4. Multivariable generalized linear mixed regression models were used to investigate the associations between their characteristics and the IVT candidates or the use of IVT among the candidates.
Results:
Among 84,103 AIS patients, 41.0% were female, with a mean age of 69 ± 13 years and presentation NIHSS of 4 [interquartile range, 1–8]. Out of these patients, 13,757 (16.4%) were eligible for IVT, of whom 8,179 (59.5%) received IVT. Female sex (adjusted risk ratio [RR], 0.90; 95% confidence interval [CI], 0.86–0.94) and lower years of education (adjusted RR, 0.90; 95% CI, 0.84–0.97 for 0–3 years, compared to ≥ 13 years) were associated with a decreased likelihood of presenting as eligible for IVT after AIS; meanwhile, young age (adjusted RR, 1.12; 95% CI, 1.01–1.24 for ≤ 44 years, compared to 75–84 years) was associated with an increased likelihood of being an IVT candidate. Among those who were eligible for IVT, only age was significantly associated with the use of IVT (adjusted RR, 1.09; 95% CI, 1.03–1.16 for age 65–74 and adjusted RR, 0.83; 95% CI, 0.76–0.90 for ≥ 85 years, respectively).
Conclusion
Most patients with AIS present outside IVT eligibility in South Korea, and only 60% of eligible patients were ultimately treated. We identified increased age, female sex and lower education as key features on which to focus interventions for improving IVT utilization.
2.Prediction of 5-Year Survival Rate After Hip Fracture Surgery Using a Comprehensive Geriatric Assessment-Based Frailty Score Model
Jung-Yeon CHOI ; Jung-Wee PARK ; Kwang-il KIM ; Young-Kyun LEE ; Cheol-Ho KIM
Journal of Korean Medical Science 2025;40(12):e40-
Background:
Hip fractures (HFs) are major osteoporotic injuries associated with morbidity, loss of independence, increased mortality, and an increased socioeconomic burden.The total number of HFs is increasing owing to an aging population. While studies have focused on 30-day or 1-year mortality after HF surgery, studies reporting long-term mortality are lacking. Our study bridges this knowledge gap by exploring the relationship between frailty, postoperative complications, and the 5-year mortality after HF surgery.This study aimed to identify the risk factors associated with 5-year mortality after HF surgery. The impact of the Hip-Multidimensional Frailty Score (Hip-MFS) and postoperative complications on 5-year mortality was compared.
Methods:
This retrospective study included 536 individuals aged 65 years and older with HFs who underwent surgery between 2009 and 2014. The Hip-MFS was calculated using the comprehensive geriatric assessment. Patients whose Hip-MFS score above 8 considered as frail. Postoperative complications included pneumonia, urinary tract infection, delirium, pulmonary thromboembolism, and unplanned intensive care unit admission after surgery.The primary outcome was 5-year mortality. Univariate and multivariate cox-regression, Kaplan–Meier analysis and log-rank tests were used to assess predictive value of frailty and postoperative complications on 5-year mortality.
Results:
The mean age was 80.5 ± 7.0 years and 71.3% (n = 382) were women. Overall, 48.3% (n = 259) were diagnosed with femoral neck fractures, and 51.7% (n = 277) were diagnosed with intertrochanteric fractures. A total of 223 (41.6%) patients experienced postoperative complications. The overall mortality rate was 60.4% (n = 324), with 1-year and 5-year mortality rates after HF surgery being 13.8% (n = 74) and 43.8% (n = 235), respectively. In the multivariate regression analysis, after adjusting for clinical and demographic factors, the high-risk Hip-MFS group and the group with postoperative complications had hazard ratios for 5-year survival of 1.513 (95% confidence interval [CI], 1.105–2.017; P = 0.010) and 1.470 (95% CI, 1.117–1.936;P = 0.006), respectively. Patients who had postoperative complications with a low Hip-MFS showed better 5-year survival than those without postoperative complications with a high Hip-MFS in the Kaplan–Meier curve (P = 0.013).
Conclusion
A high Hip-MFS risk and postoperative complications were associated with an increased 5-year mortality rate. In comparison to the occurrence of postoperative complications, the frailty status evaluated using the Hip-MFS had a more significant impact on long-term mortality after HF surgery.
3.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
4.Comparing Stability, Gait, and Functional Score after 40-mm Dual-Mobility Hip Arthroplasty to 36-mm Head Hip Arthroplasty in Elderly Hip Fracture Patients
Yonghan CHA ; Sang-Yeob LEE ; Ji-Ho BAE ; Yang Jae KANG ; Ji-Hoon BAEK ; Joon Soon KANG ; Chan Ho PARK ; Shinjune KIM ; Jun-Il YOO
Clinics in Orthopedic Surgery 2025;17(1):62-70
Background:
This study aimed to compare the intraoperative stability and early clinical outcomes of 40-mm diameter dual mobility (DM)-total hip arthroplasty (THA) with 36-mm ceramic head (large head) THA in active elderly patients with hip fractures.
Methods:
A prospective randomized controlled trial was conducted from May 2022 to December 2022. Inclusion criteria were as follows: age ≥ 60 years, displaced femoral neck fracture, Koval grade 1 or 2, planned 54-mm acetabular component, and over 1-year follow-up. Intraoperative stability tests were performed on all patients (internal rotation at 45°, 60°, and 90° of hip fracture). Functional outcomes (Harris Hip Score and University of California, Los Angeles [UCLA] Score) were evaluated at 6 weeks and 3 months postoperatively. Gait analysis using artificial intelligence (AI) techniques was conducted at 3 months postoperatively.
Results:
The study included 36 DM-THA patients (mean age, 69.6 ± 2.2 years; 44% women) and 37 large head THA patients (mean age, 69.6 ± 1.2 years; 64% women). No statistically significant differences were observed in functional outcomes and hip range of motion between the 2 groups. However, there was a significant difference in the gait speed and stance-swing phase of the large head THA group and the DM-THA group: the DM-THA group demonstrated superior gait speed (2.85 ± 0.83 kph vs. 2.04 ± 1.04 kph, p = 0.003) and higher stance phase ratios (operated side: 63.57% ± 3.82% vs. 48.19% ± 5.50%, p < 0.001; opposite side: 62.77% ± 2.27% vs. 49.93% ± 6.94%, p < 0.001). In the stability test at 90° of hip flexion, the DM-THA group had a measurement of 48.40° ± 5.17°, while the large head THA group had a measurement of 30.94° ± 2.98° (p = 0.012). Despite the lack of statistical significance, the intraoperative stability test showed the dislocation angle was notably different between the groups in the hip flexion position of 60° (51.60° ± 6.09° in the DM-THA group and 40.00° ± 2.80° in the large head THA group, p = 0.072).
Conclusions
Superior results were observed in the intraoperative stability test and early recovery of gait after DM-THA compared to large head THA. We believe that DM-THA can be a useful surgical option for THA in elderly patients with hip fractures.
5.Knee Morphology and Proximal Tibial Bone Quality around the Posterior Cruciate Ligament Insertion Site Affect Injury Patterns
Young Tak CHO ; Jong Hwa LEE ; Jun Hyeok YOON ; Seok Ho HONG ; Joong Il KIM
Clinics in Orthopedic Surgery 2025;17(3):400-407
Background:
Several studies have investigated the morphological risk factors contributing to posterior cruciate ligament (PCL) injury. However, no study has focused on the injury patterns of intrasubstance tears or tibial avulsion fractures in relation to morphologies and regional bone quality. This study aimed to investigate the impact of the knee morphology and regional bone quality of the proximal tibia on the PCL injury pattern.
Methods:
This retrospective study compared the radiological features of 76 patients with PCL injuries (PI group) and 76 matched patients with normal PCL (control group). The PI group was divided into 2 subgroups: PCL avulsion fracture (PAF subgroup; n = 43) and PCL intrasubstance tear (PIT subgroup; n = 33). Measurements included the coronal notch width index, coronal tibial slope, medial and lateral posterior tibial slopes, and medial tibial depth. Three Hounsfield unit average measurements were taken from the proximal tibia around the PCL insertion site to create a summative measure of overall bone quality.
Results:
The medial tibial depth and coronal notch width index were significantly lower in the PI group than those in the control group (medial tibial depth: 2.04 ± 0.77 vs. 3.02 ± 1.04, p = 0.017; coronal notch width index: 0.21 ± 0.03 vs. 0.24 ± 0.03, p = 0.041). In the subgroup analysis, medial tibial depth and Hounsfield unit were significantly lower in the PAF subgroup than in the PIT subgroup (medial tibial depth: 1.74 ± 0.66 vs. 2.43 ± 0.77, p = 0.008, Hounsfield unit: 89.48 ± 31.73 vs. 120.15 ± 29.24, p = 0.004). Binary logistic regression analysis showed that medial tibial depth (odds ratio [OR], 0.161; p < 0.001) and Hounsfield unit (OR, 0.950;p < 0.001) were independent risk factors for PCL tibial avulsion fractures.
Conclusions
Lower notch width index and medial tibial depth are associated with PCL injuries. Shallower medial tibial depth and lower Hounsfield unit measurements around the PCL insertion site were associated with an increased incidence of PCL avulsion fractures. These findings may assist clinicians in identifying patients at risk of distinct PCL injury patterns.
6.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
7.Clinical Practice Guidelines for Dementia: Recommendations for Cholinesterase Inhibitors and Memantine
Yeshin KIM ; Dong Woo KANG ; Geon Ha KIM ; Ko Woon KIM ; Hee-Jin KIM ; Seunghee NA ; Kee Hyung PARK ; Young Ho PARK ; Gihwan BYEON ; Jeewon SUH ; Joon Hyun SHIN ; YongSoo SHIM ; YoungSoon YANG ; Yoo Hyun UM ; Seong-il OH ; Sheng-Min WANG ; Bora YOON ; Sun Min LEE ; Juyoun LEE ; Jin San LEE ; Jae-Sung LIM ; Young Hee JUNG ; Juhee CHIN ; Hyemin JANG ; Miyoung CHOI ; Yun Jeong HONG ; Hak Young RHEE ; Jae-Won JANG ;
Dementia and Neurocognitive Disorders 2025;24(1):1-23
Background:
and Purpose: This clinical practice guideline provides evidence-based recommendations for treatment of dementia, focusing on cholinesterase inhibitors and N-methyl-D-aspartate (NMDA) receptor antagonists for Alzheimer’s disease (AD) and other types of dementia.
Methods:
Using the Population, Intervention, Comparison, Outcomes (PICO) framework, we developed key clinical questions and conducted systematic literature reviews. A multidisciplinary panel of experts, organized by the Korean Dementia Association, evaluated randomized controlled trials and observational studies. Recommendations were graded for evidence quality and strength using Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology.
Results:
Three main recommendations are presented: (1) For AD, cholinesterase inhibitors (donepezil, rivastigmine, galantamine) are strongly recommended for improving cognition and daily function based on moderate evidence; (2) Cholinesterase inhibitors are conditionally recommended for vascular dementia and Parkinson’s disease dementia, with a strong recommendation for Lewy body dementia; (3) For moderate to severe AD, NMDA receptor antagonist (memantine) is strongly recommended, demonstrating significant cognitive and functional improvements. Both drug classes showed favorable safety profiles with manageable side effects.
Conclusions
This guideline offers standardized, evidence-based pharmacologic recommendations for dementia management, with specific guidance on cholinesterase inhibitors and NMDA receptor antagonists. It aims to support clinical decision-making and improve patient outcomes in dementia care. Further updates will address emerging treatments, including amyloid-targeting therapies, to reflect advances in dementia management.
8.A Rare Case of Isolated Central Nervous System Neoplasm With Histiocytic Features
Yoonsoo CHOI ; Yujin LEE ; Young Il KIM ; Seung Ho YANG
Dementia and Neurocognitive Disorders 2025;24(1):23-28
This paper discusses a rare case of a 49-year-old female diagnosed with a central nervous systemisolated neoplasm with histiocytic features, classified as histiocytic neoplasm, not otherwise specified (NOS). Despite comprehensive histopathological and genetic studies, accurately diagnosing the case proved challenging. Initial surgical findings and frozen biopsy suggested a low-grade glioma; however, subsequent immunohistochemistry and genetic analysis excluded known histiocytic subtypes such as ALK-positive histiocytosis and Erdheim-Chester disease. The patient’s condition improved following occupational rehabilitation therapy for right upper motor weakness, as well as anticonvulsant and radiation therapy, and her neurological condition remains stable. This case underscores the diagnostic challenges of Histiocytic Neoplasms and the necessity for interdisciplinary collaboration and sophisticated diagnostic techniques.
9.Mock communities to assess biases in nextgeneration sequencing of bacterial species representation
Younjee HWANG ; Ju Yeong KIM ; Se Il KIM ; Ji Yeon SUNG ; Hye Su MOON ; Tai-Soon YONG ; Ki Ho HONG ; Hyukmin LEE ; Dongeun YONG
Annals of Clinical Microbiology 2025;28(1):3-
Background:
The 16S rRNA-targeted next-generation sequencing (NGS) has been widely used as the primary tool for microbiome analysis. However, whether the sequenced microbial diversity absolutely represents the original sample composition remains unclear. This study aimed to evaluate whether 16S rRNA gene-targeted NGS accurately captures bacterial community composition.
Methods:
Mock communities were constructed using equal amounts of DNA from 18 bacterial strains in three formats: genomic DNA, recombinant plasmids, and polymerase chain reaction (PCR) templates. The V3V4 region of the 16S rRNA gene was amplified and sequenced using the Illumina MiSeq.
Results:
Data regression analysis revealed that the recombinant plasmid produced more accurate and precise correlation curve than that by the gDNA and PCR products, with a slope closest to 1 (1.0082) and the highest R² value (0.9975). Despite the same input amount of bacterial DNA, the NGS read distribution varied across all three mock communities. Using multiple regression analysis, we found that the guanine-cytosine (GC) content of the V3V4 region, 16S rRNA gene, size of gDNA, and copy number of 16S rRNA were significantly associated with the NGS output of each bacterial species.
Conclusion
This study demonstrated that recombinant plasmids are the preferred option for quality control and that NGS output is biased owing to certain bacterial characteristics, such as %GC content, gDNA size, and 16S rRNA gene copy number. Further research is required to develop a system that compensates for NGS process biases using mock communities.
10.A Rare Case of Isolated Central Nervous System Neoplasm With Histiocytic Features
Yoonsoo CHOI ; Yujin LEE ; Young Il KIM ; Seung Ho YANG
Brain Tumor Research and Treatment 2025;13(1):23-28
This paper discusses a rare case of a 49-year-old female diagnosed with a central nervous systemisolated neoplasm with histiocytic features, classified as histiocytic neoplasm, not otherwise specified (NOS). Despite comprehensive histopathological and genetic studies, accurately diagnosing the case proved challenging. Initial surgical findings and frozen biopsy suggested a low-grade glioma; however, subsequent immunohistochemistry and genetic analysis excluded known histiocytic subtypes such as ALK-positive histiocytosis and Erdheim-Chester disease. The patient’s condition improved following occupational rehabilitation therapy for right upper motor weakness, as well as anticonvulsant and radiation therapy, and her neurological condition remains stable. This case underscores the diagnostic challenges of Histiocytic Neoplasms and the necessity for interdisciplinary collaboration and sophisticated diagnostic techniques.

Result Analysis
Print
Save
E-mail