1.Tuberculous and Malignant Pleural Effusions With Adenosine Deaminase Levels of 40–70 IU/L: Trends in New Cases Over Time and Differentiation Between Groups
Jaehee LEE ; Jongmin PARK ; Jae Kwang LIM ; Ji Eun PARK ; Yong Hoon LEE ; Sun Ha CHOI ; Hyewon SEO ; Seung Soo YOO ; Shin Yup LEE ; Seung-Ick CHA ; Jae Yong PARK ; Chang Ho KIM
Journal of Korean Medical Science 2025;40(13):e35-
Background:
The diagnosis of tuberculous pleural effusion (TPE) often relies on pleural fluid adenosine deaminase (ADA) levels. The diagnostic utility of ADA, however, is influenced by the prevalence of tuberculosis (TB) in local populations. Malignant pleural effusion (MPE) cases can exhibit moderately elevated ADA levels comparable to those seen in TPE. As population aging potentially impacts ADA levels, global TB incidence is decreasing whereas the burden of malignancy is on the rise. Consequently, epidemiological shifts and temporal changes in ADA distribution complicate the differential diagnosis between TPE and MPE when ADA levels are within the 40–70 IU/L range. Nonetheless, data specific to this subset are scarce.
Methods:
This retrospective study included consecutive patients aged > 18 years with confirmed TPE and MPE, spanning from 2012 to 2023. ADA levels in pleural fluid were categorized into three groups: < 40 IU/L, 40–70 IU/L, and > 70 IU/L. The study examined annual trends in the frequency of new cases and ADA level distributions over time and identified discriminating factors between TPE and MPE in cases with ADA levels of 40–70 IU/L.
Results:
In total, 297 TPE and 369 MPE cases were included in this study. Over the study period, the frequency of TPE progressively declined, while that of MPE increased. In the most recent four-year period, new TPE and MPE cases with ADA levels of 40–70 IU/L occurred at comparable numbers. Multivariable analysis identified pleural fluid carcinoembryonic antigen (CEA) levels and the number of focal pleural nodules as independent predictors for MPE. Specifically, the presence of either CEA levels > 15.7 ng/mL or more than eight pleural nodules yielded the highest diagnostic accuracy with a sensitivity of 88%, specificity of 100%, and an area under the curve of 0.95.
Conclusion
The differential diagnosis between TPE and MPE with pleural ADA levels of 40–70 IU/L has become increasingly critical due to evolving epidemiological patterns and ADA distribution changes over time. Pleural fluid CEA levels and the characteristics of pleural nodules may offer valuable guidance in distinguishing between TPE and MPE within this diagnostic gray zone.
2.Delayed Diagnosis of Imported Cystic Echinococcosis and Successful Treatment With Percutaneous Drainage and Albendazole in Korea: A Case Report
Won Jun CHOI ; Hanna JIN ; Hyeon Jae JO ; Chan Mi LEE ; Chang Kyung KANG ; Pyoeng Gyun CHOE ; Wan Beom PARK ; Nam Joong KIM ; Min-Ho CHOI
Journal of Korean Medical Science 2025;40(4):e88-
Echinococcosis, caused by the tapeworm Echinococcus, is rare in Korea and is primarily imported from endemic areas. We report a case of a 37-year-old Korean man with multiple large hepatic cysts, initially diagnosed as simple cysts at a local clinic in 2018. The patient had lived in Oman, an endemic area, for several months in 2016. Upon referral to a tertiary hospital in 2023, due to progressive cyst enlargement, liver magnetic resonance imaging revealed three large cysts with a water lily sign. Serum IgG against Echinococcus was positive by enzyme-linked immunosorbent assay. After diagnosis of echinococcosis, treatment with albendazole and puncture-aspiration-injection-reaspiration (PAIR) was performed.Microscopic and molecular analysis of cyst aspirates confirmed Echinococcus granulosus infection. Follow-up computed tomography demonstrated a reduction in cyst size, yet the emergence of a new right pleural effusion and consolidation in the left lower lobe of the lung necessitated the continuation of albendazole therapy. This case highlights the importance of thorough travel history, imaging findings, and the effectiveness of PAIR combined with albendazole in treating imported echinococcosis.
3.Prediction of Hemifacial Spasm Re-Appearing Phenomenon after Microvascular Decompression Surgery in Patients with Hemifacial Spasm Using Dynamic Susceptibility Contrast Perfusion Magnetic Resonance Imaging
Seung Hoon LIM ; Xiao-Yi GUO ; Hyug-Gi KIM ; Hak Cheol KO ; Soonchan PARK ; Chang-Woo RYU ; Geon-Ho JAHNG
Journal of Korean Neurosurgical Society 2025;68(1):46-59
Objective:
: Hemifacial spasm (HFS) is treated by a surgical procedure called microvascular decompression (MVD). However, HFS re-appearing phenomenon after surgery, presenting as early recurrence, is experienced by some patients after MVD. Dynamic susceptibility contrast (DSC) perfusion magnetic resonance imaging (MRI) and two analytical methods : receiver operating characteristic (ROC) curve and machine learning, were used to predict early recurrence in this study.
Methods:
: This study enrolled 60 patients who underwent MVD for HFS. They were divided into two groups : group A consisted of 32 patients who had early recurrence and group B consisted of 28 patients who had no early recurrence of HFS. DSC perfusion MRI was undergone by all patients before the surgery to obtain the several parameters. ROC curve and machine learning methods were used to predict early recurrence using these parameters.
Results:
: Group A had significantly lower relative cerebral blood flow than group B in most of the selected brain regions, as shown by the region-of-interest-based analysis. By combining three extraction fraction (EF) values at middle temporal gyrus, posterior cingulate, and brainstem, with age, using naive Bayes machine learning method, the best prediction model for early recurrence was obtained. This model had an area under the curve value of 0.845.
Conclusion
: By combining EF values with age or sex using machine learning methods, DSC perfusion MRI can be used to predict early recurrence before MVD surgery. This may help neurosurgeons to identify patients who are at risk of HFS recurrence and provide appropriate postoperative care.
4.Incidence and Clinical Course of Post-infectious Irritable Bowel Syndrome in Patients Admitted to University Hospitals: 1-year Prospective Follow-up Study
Jae Gon LEE ; Sang Pyo LEE ; Hyun Joo JANG ; Sea Hyub KAE ; Woon Geon SHIN ; Seung In SEO ; Hyun LIM ; Ho Suk KANG ; Jae Seung SOH ; Chang Seok BANG ; Young Joo YANG ; Gwang Ho BAIK ; Jin Bae KIM ; Yu Jin KIM ; Chang Kyo OH ; Hallym Gastrointestinal Study Group
Journal of Neurogastroenterology and Motility 2025;31(1):110-118
Background/Aims:
Post-infectious irritable bowel syndrome (PI-IBS) is characterized by chronic gastrointestinal symptoms that arise following an episode of infectious enteritis. The incidence rates vary, ranging from 5% to 32% and the risk factors are not well known. We aim to investigate the incidence and risk factors of PI-IBS in enteritis patients admitted to university hospitals in Korea.
Methods:
This multi-center prospective study was conducted in patients hospitalized for infectious enteritis. Each patient underwent 1 outpatient visit and 3 telephone surveys during the first year after discharge to determine if PI-IBS occurred within the follow-up period.
Results:
In the 3-month survey, 7 out of 354 patients (2%) were diagnosed with PI-IBS, and after 1 year, only 1 patient met the criteria for IBS.No statistically significant difference was found between the PI-IBS group and the non-PI-IBS group in terms of age, sex, underlying diseases, medication history, gastrointestinal symptoms, enteritis location, causative strain, hospitalization and treatment periods, and laboratory findings. Female sex (P = 0.003), enteropathogenic Escherichia coli (EPEC) infection (P = 0.044), and a longer total treatment period (P = 0.018) were independent risk factors for diarrhea lasting ≥ 3 months after enteritis.
Conclusions
The incidence of PI-IBS in Korea was relatively low, and most cases improved over time. No risk factors associated with the development of PI-IBS were found. However, persistent diarrhea after enteritis was associated with female sex, EPEC infection, and severe or long-lasting enteritis. IBS symptoms may persist after severe enteritis but usually improve with time.
5.Role of ultrasonography in the diagnosis and management of chronic recurrent sialadenitis with sialendoscopy
Hyun-Soo JUNG ; In-Seo CHANG ; Jae-yeon KIM ; In-Seok SONG ; Bo-Yeon HWANG ; Sang-Ho JUN
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(2):117-122
Chronic recurrent sialadenitis is characterized by repeated inflammation of the salivary glands, leading to ductal structural abnormalities and salivary stasis, often resulting in megaducts. This study evaluates the efficacy of ultrasonography as a diagnostic and follow-up tool for the management of chronic recurrent sialadenitis. Three patients underwent sialendoscopy, which involved ductal dilation, removal of mucous plugs, and steroid administration. Ultrasonography was used postoperatively to monitor changes in ductal structure, including megaduct size, and to assess clinical outcomes.All three cases showed marked improvement in clinical symptoms after treatment. Ultrasonography demonstrated a reduction in megaduct size and provided real-time visualization of ductal and glandular changes. Compared to traditional imaging methods such as magnetic resonance imaging or sialography, ultrasonography offered a practical and safe option for follow-up assessment. This study highlights the utility of ultrasonography as an accessible, non-invasive, and effective tool for evaluating treatment outcomes in chronic recurrent sialadenitis. By offering detailed visualization of ductal changes and facilitating longitudinal follow-up, ultrasonography can optimize the management of this condition.
6.Morphologic Analysis of Fracture Patterns in the Anterior Region of Femoral Intertrochanteric Fractures Using Computed Tomography
Jae-Suk CHANG ; Seonggeun CHU ; Ji-Wan KIM ; Chul-Ho KIM
The Journal of the Korean Orthopaedic Association 2025;60(1):38-45
Purpose:
Intertrochanteric fractures often involve comminuted fractures, particularly around the intertrochanteric ridge, including the greater and lesser trochanters. In cases with comminuted fractures in the posterior region, maintaining a stable reduction of the anteriormedial region of the fracture surface is essential. Therefore, this study examined the morphologic features of the anterior femur for stable reduction by analyzing the anterior region of intertrochanteric fractures using three-dimensional computed tomography.
Materials and Methods:
This retrospective study analyzed the imaging data of 51 patients aged 60 years and older who underwent a surgical treatment for intertrochanteric fractures at a single institution from April 2013 to March 2023. The sample contained 15 male patients with an average age of 81.9 years and 36 female patients with an average age of 83.7 years. Forty patients (78.4%) had two or more comorbidities. The bone mineral density was assessed in all cases except for five (9.8%).
Results:
In 49 cases (96.1%), the anterior fracture line followed the intertrochanteric line and passed through two bony prominences.In two cases (3.9%), the fracture line ran below the intertrochanteric line and involved a large fragment of the lesser trochanter. As the fracture line passed through the inferior medial bony prominence, it exhibited an S-shaped pattern rather than a straight line. The inferior medial bony prominence consisted of cortical bone, with an average thickness of 6.4±1.4 mm, which was significantly thicker than the surrounding average cortical bone thickness (1.5±0.6 mm) but thinner than the cortical bone thickness of the femoral shaft (7.3±1.3 mm).The fracture line in the superior lateral region of the intertrochanteric line included cancellous bone with a cortical bone thickness of 1.1±0.6 mm, which was thin.
Conclusion
The anterior fracture line followed the femoral intertrochanteric line and curves as it passed through the inferior medial bony prominence. The inferior medial bony prominence, consisting of cortical bone, was significantly thicker than the surrounding average cortical bone.
7.Effect of regional COVID-19 outbreak to emergency department response on acute myocardial infarction: a multicenter retrospective study
Young Wook KIM ; Sungbae MOON ; Hyun Wook RYOO ; Jae Yun AHN ; Jung Bae PARK ; Dong Eun LEE ; Sang Hun LEE ; Sangchan JIN ; You Ho MUN ; Jung Ho KIM ; Tae Chang JANG
Journal of the Korean Society of Emergency Medicine 2025;36(2):72-82
Objective:
The Daegu region experienced the first wave of the pandemic at the beginning of the coronavirus disease 2019 (COVID-19) outbreak in Korea. Other non-COVID-19-related treatments during a community outbreak, such as cardiovascular diseases, were expected to impact emergency departments. In acute myocardial infarctions, time is an important factor affecting the patient outcome. This study examined how community COVID-19 outbreak affected STsegment elevated myocardial infarction (STEMI) care in emergency departments.
Methods:
A retrospective analysis was performed on patients visiting five emergency departments in the Daegu area who were diagnosed with STEMI from February 18 to April 17 each year from 2018 to 2020. The demographic characteristics, prehospital variables, in-hospital time variables, and treatment results were collected. The cases were divided into the pre-COVID period and the COVID period for comparison.
Results:
The study included 254 patients (194 pre-COVID, 60 during COVID). The symptom-to-door time did not differ. Although the door-to-first doctor time was shortened (4 min vs. 2 min, P=0.01), the rate of coronary angiogram along with the door-to-angiogram time and the door-to-balloon time did not change. The length of stay in the emergency department was delayed during COVID-19 (median, 136 min vs. 404 min; P<0.01). The in-hospital length of stay and mortality were similar in both groups.
Conclusion
The time to treat STEMI was not delayed significantly during the first wave of the COVID-19 outbreak in the Daegu area compared with the pre-pandemic period. Mortality did not change. The length of stay was elongated significantly in the emergency department but not in the hospital.
8.Comparative Study of 3-Dimensional-Printed Poly-L-Lactic Acid/Bone Morphogenetic Protein (BMP)/Collagen Bone Substitute and Commercial Hydroxyapatite/BMP for Bone Regeneration Efficacy Using a Mouse Calvarial Model
Tae Ho KIM ; Yu Ri HONG ; Jeong Ok LIM ; Chang-Wug OH
Clinics in Orthopedic Surgery 2025;17(2):340-345
Background:
Bone substitutes such as hydroxyapatite (HA) ceramic and recombinant bone morphogenetic protein-2 (BMP-2) are essential in treating bone defects. However, the challenges of controlled and localized BMP-2 delivery necessitate the development of advanced bone graft substitutes. This study introduces and evaluates an innovative, ready-to-use bone substitute employing 3-dimensional-printed poly-L-lactic acid (PLLA) scaffolds combined with BMP-2 to enhance bone regeneration efficiency.
Methods:
We conducted a comparative study using C57BL/6 mice to evaluate the efficacy of rhBMP-2-coated PLLA scaffolds against traditional HA-based bone graft materials. The PLLA scaffolds were coated with varying concentrations of BMP-2 using an alginate-catechol method. Bone regeneration was assessed through micro-computed tomography (CT) imaging and histological analysis 4 weeks after implantation. The statistical significance of bone mass and formation differences across groups was determined using Student t-test and analysis of variance.
Results:
Micro-CT analysis revealed substantial bone formation in the group with PLLA scaffolds containing 0.1% BMP-2, exhibiting a bone volume ratio of 11.1% ± 2.8%, significantly higher than all other groups (p = 0.008). Histological analysis corroborated these findings, showing dense collagen deposition and active osteoblast presence in this group, indicating enhanced bone regeneration.
Conclusions
The novel PLLA scaffold with alginate-catechol-coated BMP-2 significantly enhances bone regeneration compared to traditional bone graft materials. This innovative approach holds promising potential for clinical applications in orthopedics, particularly for treating bone defects.
9.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
10.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.