1.Effectiveness of combined anteversion angle technique in total hip arthroplasty for treatment of ankylosing spondylitis affecting hip joint.
Yuan WANG ; Fang PEI ; Feng WAN ; Zexuan WANG ; Xiaolei LIU ; Kaijin GUO
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):15-21
OBJECTIVE:
To explore the effectiveness of the combined anteversion angle technique in total hip arthroplasty (THA) for treating ankylosing spondylitis (AS) affecting the hip joint.
METHODS:
A retrospective analysis was conducted on the clinical data of 73 patients with AS affecting the hip joint who underwent THA between August 2018 and August 2021. According to whether the combined anteversion angle technique was used in THA, the patients were divided into study group (37 cases, combined anteversion angle technique was used in THA) and control group (36 cases, traditional THA). There was no significant difference in baseline data such as gender, age, body mass index, disease duration, preoperative Harris score, range of motion (ROM), acetabular anteversion angle, acetabular abduction angle, femoral anteversion angle, and combined anteversion angle between the two groups ( P>0.05). The operation time, hospital stay, and complications of the two groups were recorded and compared. The Harris score and hip ROM were compared between the two groups before operation, at 1, 3, 6, 12 months after operation, and at last follow-up. The acetabular component anteversion angle, femoral component anteversion angle, acetabular component abduction angle, and component combined anteversion angle were measured postoperatively.
RESULTS:
The operation time in the study group was significantly shorter than that in the control group ( P<0.05), and there was no significant difference in hospital stay between the two groups ( P>0.05). There was no intraoperative complication such as acetabular and proximal femoral fractures, neurovascular injuries in both groups, and the incisions healed by first intention. All patients were followed up 2-3 years, with an average of 2.4 years; there was no significant difference in the follow-up time between the two groups ( P>0.05). During the follow-up period, there was no complication such as hip dislocation, wound infection, delayed wound healing, deep venous thrombosis, and hip dislocation in both groups. The hip Harris score and ROM of the two groups gradually increased with time after operation, and the differences were significant when compared with those before operation ( P<0.05); the above two indicators of the study group were significantly better than those of the control group at each time point after operation ( P<0.05). Extensive bone ingrowth on the surface of the components could be observed in the anteroposterior X-ray films of the hip joint of the two groups at 12 months after operation, and the acetabular components was stable without femoral stem subsidence, osteolysis around the components, and heterotopic ossification. At last follow-up, the acetabular component anteversion angle, femoral component anteversion angle, and component combined anteversion angle in the study group were significantly superior to those in the control group ( P<0.05), except that there was no significant difference in the acetabular component abduction angle between the two groups ( P>0.05).
CONCLUSION
For patients with AS affecting the hip joint, the use of the combined anteversion angle technique during THA effectively promotes the recovery of hip joint function and enhances the postoperative quality of life of patients when compared to traditional THA.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Dislocation/surgery*
;
Spondylitis, Ankylosing/surgery*
;
Retrospective Studies
;
Quality of Life
;
Treatment Outcome
;
Hip Joint/surgery*
;
Hip Prosthesis
2.Single Kocher-Langenbeck approach combined with anterograde channel screw technique in treatment of acetabular transverse and posterior wall fractures.
Xuepeng XU ; Jinhui LIU ; Lincong FEI ; Junwu YE
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):35-39
OBJECTIVE:
To assess the effectiveness of the single Kocher-Langenbeck approach combined with anterograde channel screw technique for the treatment of acetabular transverse and posterior wall fractures.
METHODS:
Between March 2020 and October 2022, 17 cases of acetabular transverse and posterior wall fractures were treated with the single Kocher-Langenbeck approach combined with anterograde channel screw technique. There were 11 males and 6 females, with an average age of 53.6 years (range, 42-64 years). Causes of injury included traffic accident in 12 cases, and falling from height in 5 cases. The time from injury to operation ranged from 4 to 16 days with an average of 8.8 days. The operation time, intraoperative blood loss, and fluoroscopy frequency were recorded; X-ray films were reviewed regularly after operation to observe the fracture healing, and postoperative complications were recorded. At last follow-up, Matta score was used to evaluate the reduction of fracture, Harris score and modified Merle D'Aubigné-Postel scores system were used to evaluate the hip joint function.
RESULTS:
The operation time was 150-230 minutes (mean, 185.9 minutes), the intraoperative blood loss was 385-520 mL (mean, 446.2 mL), and the fluoroscopy frequency was 18-34 times (mean, 27.5 times). Postoperative fat liquefaction occurred in 1 case and the other incisions healed by first intention; 3 cases had limb numbness after operation, and the symptoms disappeared after active symptomatic treatment; no urogenital system and intestinal injury occurred. All patients were followed up 12-28 months (mean, 19.9 months). Bone union was achieved in all cases with an average healing time of 10.8 weeks (range, 8-14 weeks). There was no complication such as loosening and breakage of internal fixators. At last follow-up, according to Matta score, 12 cases achieved anatomic reduction, 3 satisfactory reduction, and 2 fair reduction, the satisfactory rate was 88.2%; according to Harris hip function score, 12 cases were excellent, 3 good, and 2 fair, the excellent and good rate was 88.2%; according to the modified Merle D'Aubign Aubigné-Postel scoring system, the results were excellent in 11 cases, good in 3 cases, and fair in 3 cases, with an excellent and good rate of 82.4%.
CONCLUSION
The single Kocher-Langenbeck approach combined with anterograde channel screw technique is a minimally invasive method for the treatment of acetabular transverse and posterior wall fractures with less complications, simple operation, and satisfactory effectiveness.
Male
;
Female
;
Humans
;
Middle Aged
;
Blood Loss, Surgical
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
;
Fractures, Bone/surgery*
;
Acetabulum/injuries*
;
Bone Screws
;
Hip Fractures/surgery*
;
Retrospective Studies
3.Relationship between the gross motor function classification system and hip and lumbar spine development in children with spastic cerebral palsy.
Gang LIU ; Li LIU ; Lin XU ; Chao MA ; Bo-Wen DENG ; Sheng-Yuan JIANG ; Rui-Qin YU ; Yi ZHAO ; Xiao-Hong MU
China Journal of Orthopaedics and Traumatology 2023;36(1):79-85
OBJECTIVE:
To investigate the relationship among the gross motor function classification system (GMFCS)and the development of hip joint and lumbar spine in children with spastic cerebral palsy.
METHODS:
The clinical data of 125 children with spastic cerebral palsy admitted from January 2018 to July 2021 were retrospectively analyzed. There were 85 males and 40 females, aged from 4 to 12 years old with an average of (8.4±2.9) years. According to GMFCS, the patients were divided into gradeⅠ, Ⅱ, Ⅲ and Ⅳ groups. There were 27 cases in gradeⅠgroup, 40 cases in gradeⅡgroup, 35 cases in grade Ⅲ group and 23 cases in grade Ⅳ group. The migration percentage(MP), central edge angle(CE), neck-shaft angle(NSA), acetabular index(AI) were measured by the radiograph of pelvis, abnormal parameters were selected to evaluate the relationship between different GMFCS grades and hip joint development. Lumbar sagittal Cobb angle, lumbar sacral angle, lumbar lordosis index and apical distance were measured by lateral lumbar radiographs to evaluate the relationship between different GMFCS grades and lumbar spine development.
RESULTS:
①Among the 125 spastic cerebral palsy children, there were 119 cases of pelvic radiographs that met the measurement standards. In the four groups with gradeⅠ, Ⅱ, Ⅲ, Ⅳ, MP was (22.72±3.88), (26.53±4.36), (33.84±4.99), and (49.54±7.87)%, CE was(30.10±6.99) °, ( 22.92±4.19) °, ( 17.91±5.50) °, and (-0.70±17.33)°, AI was (16.41±2.77) °, (20.46±4.63) °, (23.76±5.10) °, and ( 29.15±7.35)°, respectively, there were significant differences between the two comparisons (P<0.05). And the higher GMFCS grade, the greater MP and AI, and the smaller CE.The NSA was(142.74±10.03) °, (148.66±9.09) °, (151.66±10.52) °, and (153.70±8.05)° in four groups with gradeⅠ, Ⅱ, Ⅲ, Ⅳ, respectively. The differences between the two comparisons of the GMFCS gradeⅠgroup and the other three groups were statistically significant (P<0.05). NSA of GMFCSⅠgroup was significantly lower than that of the others, there was no significant difference among other groups(P>0.05). ② Among the 125 spastic cerebral palsy children, there were 88 cases of lumbar spine radiographs that met the measurement standards. ③The lumbar sagittal Cobb angle was(32.62±11.10) °, (29.86±9.90) °, (31.70±11.84) °, and (39.69±6.80)° in the four groups with gradeⅠ, Ⅱ, Ⅲ, Ⅳ, respectively;GMFSS of grade Ⅳ group was significantly higher than that of other three groups, there was significant difference between the two comparisons (P<0.05);there were no significant differences between other groups (P>0.05). In the four groups with gradeⅠ, Ⅱ, Ⅲ, Ⅳ, the lumbosacral angle was (31.02±9.91) °, ( 26.57±9.41) °, (28.08±8.56) °, and ( 27.31±11.50)°, the lumbar lordosis index was (4.14±12.89), (8.83±13.53), (13.00±11.78), and (10.76±9.97) mm, the arch apex distance was (9.50±6.80), (6.68±3.20), (7.16±4.94), and (6.62±4.13) mm, respectively, there were no significant differences between the two comparisons(P>0.05).
CONCLUSION
①In children with GMFCS gradeⅠ-Ⅳ, the higher the GMFCS grade, the worse the hip develops. ② Children with GMFCS grade Ⅲ-Ⅳ may be at greater risk for lumbar kyphosis.
Male
;
Female
;
Humans
;
Child
;
Child, Preschool
;
Lordosis
;
Retrospective Studies
;
Cerebral Palsy
;
Hip Dislocation
;
Lumbar Vertebrae/diagnostic imaging*
;
Muscle Spasticity
5.Surgical treatment for ipsilateral femoral neck and shaft fracture.
Bang DOU ; Wen-Qian MA ; Tao QIN ; Wei ZHU ; Ya-Hui DAI ; Xiao-Bin XU
China Journal of Orthopaedics and Traumatology 2023;36(3):203-208
OBJECTIVE:
To retrospectively analyze efficacy of single structure internal fixation and double structure internal fixation in the treatment of ipsilateral femoral shaft and neck fracture, and analyze their indications.
METHODS:
From June 2015 to December 2020, 21 patients with ipsilateral femoral shaft and femoral neck fracture were treated, including 14 males and 7 females, aged 23 to 69 years old with an average of(38.1±12.9) years old. According to different femoral shaft fracture sites, some patients were fixed with cephalomedullary implant for both femoral neck and the femoral shaft(single structure, InterTan or PFNA Ⅱ), some patients were fixed with cannulated screws for the femoral neck and a retrograde locking nail for the femoral shaft (dual structure), and postoperative function and complications were recorded during follow-up. In 10 cases of single-structure fixation, the femoral necks were all basicervical fractures, and the femoral shaft fractures were located in the proximal isthmus;11 cases were double-structure fixation, 9 cases in 11 were basal type of femoral neck, 2 cases in 11 were neck type, and the femoral shaft fractures were located in the isthmus and the distal isthmus.
RESULTS:
All patients were followed up for 12 to 27 months. No femoral head necrosis, deformity, delay or nonunion occurred in the patients with single-structure fixation, and no delayed union or nonunion occurred in femoral shaft fractures;At the final follow-up, Harris score of patients with single-structure fixation was 91.8±4.1, with 8 cases were excellent and 2 cases were good. The fractures of patients with dual-structure fixation achieved good union without femoral head necrosis, except 1 case of femoral shaft fracture had delayed union;At the final follow-up, Harris score of patients with dual-structure fixation was 92.4±5.9, 7 cases were excellent, 3 cases were good, and 1 case was fair.
CONCLUSION
Good reduction and fixation is the key to the treatment of such fractures. Both the single-structure fixation and the dual-structure fixation are good methods, and it should be selected according to the locations of femoral shaft and femoral neck fractures. Single-structure fixation is a good choice for femoral shaft fractures located at the proximal isthmus and basal femoral neck fractures. For isthmus and distal femoral shaft fractures combined with ipsilateral femoral neck fractures, dual-structure fixation is recommended.
Male
;
Female
;
Humans
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Femur Neck
;
Retrospective Studies
;
Femoral Neck Fractures/complications*
;
Femoral Fractures/complications*
;
Fracture Fixation, Internal/methods*
;
Femoral Fractures, Distal
;
Treatment Outcome
;
Fracture Fixation, Intramedullary/methods*
6.Application of 3D printing percutaneous guide plate in closed reduction and cannulated screw internal fixation of femoral neck fracture.
Qing-Ze WANG ; Ming-Xing LUO ; Shuai ZENG ; Jun-Guo BAO ; Wen-Li LUO ; Kai-Zong YUAN ; Li-Feng LAO
China Journal of Orthopaedics and Traumatology 2023;36(3):209-215
OBJECTIVE:
To investigate the application of 3D printing percutaneous surgical guide plate in closed reduction and cannulated screw internal fixation of femoral neck fracture.
METHODS:
The clinical data of 12 patients with femoral neck fracture from March 2019 to March 2022 were retrospectively analyzed. Patients were divided into observation group and control group according to different operation plans, with 6 cases in each group. The observation group received percutaneous operation guide plate assisted closed reduction and hollow screw internal fixation, while the control group received closed reduction and hollow compression screw internal fixation. The operation time, intraoperative blood loss, fluoroscopy times, and Kirschner needle puncture times were compared between two groups. The location of screws were recordedon postoperative X-ray films, follow-up time, time of complete fracture healing, Harris score of hip joint and the incidence of complications were recorded on postoperative X-ray films.
RESULTS:
The operation time of observation group (32.17±6.18) min was shorter than that of control group (53.83±7.31) min (P<0.05). The amount of intraoperative bleeding in the observation group (18.33±2.94) ml was less than that in the control group (38.17±5.56) ml(P<0.05). The times of fluoroscopy in the observation group (7.50±1.05) were less than those in the control group (21.00±4.82) (P<0.05). The number of Kirschner needle punctures (8.00±0.63) in observation group was less than that in control group (32.67±3.08) (P<0.05). The follow-up time was(12.88±0.74) months in observation group and (12.83±0.72) months in control group, there was no significant difference between two groups (P>0.05). One year after operation, Harris score of hip joint in the observation group was(82.00±4.52) points, while that in the control group was(81.00±3.41) points, there was no significant difference between two groups(P>0.05). The time of complete fracture healing in the observation group was (7.50±1.05) months, while that in the control group was (7.67±1.21) months, there was no significant difference between two groups(P>0.05). The parallelism of the screws in the observation group was (0.50±0.11) ° and (0.76±0.15) °, which were lower than that in the control group (1.57±0.31) ° and (1.87±0.21) ° (P<0.05). The screw distribution area ratio (0.13±0.02) cm2 in the observation group was higher than that in the control group (0.08±0.01) cm2 (P<0.05). No complications such as necrosis of femoral head, nonunion of fracture, shortening of femoral neck and withdrawal of internal fixation occurred in both groups.
CONCLUSION
The application of 3D printing percutaneous surgical guide plate improves the accuracy and safety of closed reduction and cannulated screw internal fixation for femoral neck fracture. It has the advantages of minimally invasive, reducing radiation exposure, fast and accurate, shortening the operation time and reducing intraoperative bleeding.
Humans
;
Retrospective Studies
;
Treatment Outcome
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal
;
Bone Screws
;
Printing, Three-Dimensional
7.Disastrous triad of femoral head:femoral neck fracture meeting fracture-dislocation of femoral head.
China Journal of Orthopaedics and Traumatology 2023;36(3):216-221
Femoral head and ipsilateral femoral neck fractures are serious and complicated injuries, which usually yield unsatisfactory results using conventional hip-preserving surgery. The key point of the management and prognosis mainly lies in femoral neck fractures. An apparent and consecutive relationship exists between femoral neck fractures and femoral head fracture-hip dislocation in such injuries. It is believed that disastrous triad of femoral head (DTFH) could summarize these specific injuries, and reflect the injury mechanism and prognostic characteristics. Based on our clinical observation and literature review, DTFH could be divided into three subgroups:TypeⅠ, common DTFH, in which femoral neck fractures occur following femoral head fractures-hip dislocation due to the same trauma; TypeⅡ, iatrogenic DTFH, in which femoral neck fractures come out in the caring process of femoral head fractures-hip dislocation; Type Ⅲ, stressed DTFH, in which femoral neck fractures occur after the management of femoral head fractures-hip dislocation. In the scenario, the line of femoral neck fractures locates distally to the femoral head fractures. Herein, we will discuss clinical characteristics of these types of DTFH.
Humans
;
Femoral Fractures/complications*
;
Femoral Neck Fractures/complications*
;
Femur Head/injuries*
;
Fracture Dislocation
;
Fracture Fixation, Internal/methods*
;
Hip Dislocation/surgery*
;
Prognosis
8.Comparison of curative effect between Tianji robot assisted screw placement and traditional cannulated screw internal fixation for femoral neck fracture.
De-Xin NIE ; Wen-Gao SUN ; Xiao-Qiang WANG ; Ming-Jun WANG ; Jin-Bo SUN ; Chun CHEN
China Journal of Orthopaedics and Traumatology 2023;36(3):221-225
OBJECTIVE:
To investigate the clinical efficacy and advantages of Tianji orthopedic robot assisted cannulated screw internal fixation for femoral neck fracture.
METHODS:
The clinical data of 41 patients with femoral neck fracture who underwent internal fixation with cannulated screws from January 2019 to January 2022 were retrospectively analyzed. According to different surgical methods, they were divided into Tianji robot group and traditional cannulated screw fixation group (traditional operation group). Among them, there were 18 patients in Tianji robot group including 8 males and 10 females with age of (56.00±4.22) years old, Garden typeⅠ (4 cases), type Ⅱ (11 cases), type Ⅲ (2 cases), and type Ⅳ (1 case). There were 23 patients in the traditional operation group, including 10 males and 13 females, aged (54.87±4.81) years old;there were 5 cases of Garden typeⅠ, 14 cases of type Ⅱ, 3 cases of type Ⅲ and 1 case of type Ⅳ. The operation time, intraoperative blood loss, fluoroscopy times, guide needle placement times, operation costs and other indicators were observed and compared between two groups. Harris score was used to evaluate hip joint function 12 months after operation.
RESULTS:
The wounds of all patients healed in Grade A without complications. There were significant differences between two groups in terms of operation time, times of intraoperative fluoroscopy, times of guide needle placement, amount of intraoperative bleeding, and operation cost (P<0.05). All 41 patients were followed up for at least 12 months. The fractures of both groups were healed. There was no infection, screw loosening, fracture displacement and femoral head necrosis in Tianji robot group during follow-up;Screw loosening occurred in 2 patients in the traditional operation group during follow-up. At 12 months after operation, Harris hip joint function score of Tianji robot group was higher than that of traditional operation group in daily activity, lameness, joint activity score and total score (P<0.05).
CONCLUSION
Tianji robot assisted nail placement is a better method for the treatment of femoral neck fracture, which improves the surgical efficiency, is more accurate, has higher success rate of one-time nail placement, shorter operation time, less radiation, and has better hip joint function recovery after surgery.
Male
;
Female
;
Humans
;
Middle Aged
;
Robotics
;
Retrospective Studies
;
Femoral Neck Fractures/surgery*
;
Bone Screws
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
9.Comparison of curative effect between percutaneous compression plate and cannulated compression screw in the treatment of displaced femoral neck fractures in young and middle-aged patients.
Xue-Liang CUI ; He LI ; Liu SHI ; Wen-Jun XIE ; Hui CHEN
China Journal of Orthopaedics and Traumatology 2023;36(3):226-231
OBJECTIVE:
To compare the efficacy of percutaneous compression plate and cannulated compression screw in the treatment of displaced femoral neck fractures in young and middle-aged patients.
METHODS:
From January 2015 to July 2020, 68 young and middle-aged patients with displaced femoral neck fracture were retrospectively analyzed. Among them, 31 cases were fixed by percutaneous compression plate (PCCP), and 37 cases were fixed by cannulated compression screw (CCS). General data such as gender, age, cause of injury, comorbidities, fracture classification and cause of injury of two groups were collected. The operation time, intraoperative blood loss, hospital stay, full weight bearing time, fracture healing time, visual analogue scale(VAS), Harris hip score and complications were compared between two groups.
RESULTS:
Patients in both groups were followed up for more than 2 years. There were no significant differences in operation time, intraoperative blood loss, fracture reduction quality, hospital stay and VAS between two groups. The fracture healing time in PCCP group was significantly shorter than that in CCS group (t=-4.404, P=0.000). The complete weight bearing time of PCCP group was significantly shorter than that of CCS group (t=-9.011, P=0.000). Harris score of hip joint in PCCP group was better than that in CCS group 2 years after operation (P=0.002). Complications occurred in 3 cases (9.68%) in PCCP group, while 11 cases (29.72%) in CCS group, with a statistically significant difference (P=0.042).
CONCLUSION
Both PCCP and CCS can be used for the treatment of displaced femoral neck fractures in young and middle-aged people. Compared with CCS, PCCP fixation can achieve shorter fracture healing time and create conditions for early full weight bearing. PCCP results in higher hip score and lower complications.
Middle Aged
;
Humans
;
Treatment Outcome
;
Blood Loss, Surgical
;
Retrospective Studies
;
Fracture Fixation, Internal/methods*
;
Femoral Neck Fractures/surgery*
;
Bone Screws
10.Comparison of effect between internal fixation and total hip replacement in the treatment of displaced femoral neck fracture in middle age patients.
Zhi-Yuan WANG ; Fan LUO ; Ying-Qi ZHANG ; Jia LIU ; Xiao-Zhong ZHU ; Zhi-Tao RAO
China Journal of Orthopaedics and Traumatology 2023;36(3):232-235
OBJECTIVE:
To analyze and compare the clinical efficacy of internal fixation and total hip replacement in the treatment of displaced femoral neck fracture from 55 to 65 years.
METHODS:
From September 2016 to August 2020, 86 patients with Garden type Ⅲ or Ⅳ femoral neck fracture were divided into two groups according to different surgical methods. Among them, 38 patients were treated with lag screws for internal fixation, there were 26 males and 12 females, aged 55 to 64 years old with an average of(60.2±3.1) years;the other 48 patients were treated with total hip replacement, including 28 males and 20 females, aged from 57 to 65 years old with an average of(61.3±3.8) years. The time from injury to operation ranged from 1 to 3 days. The reoperation rate, incidence of deep infection, Harris score of hip joint function, visual analogue scale(VAS) of pain and patients reported outcome scores(European five-dimensional Health Questionnaire, EQ-5D) were compared between two groups.
RESULTS:
All patients were followed up for 24 to 54 months with an average of (35.8±10.3) months. There was significant difference in reoperation rate between two groups (P<0.05). There was no significant difference on the incidence of deep infection, hip Harris score and VAS between two groups(P>0.05) . The postoperative EQ-5D score of patients with internal fixation was lower than that of total hip replacement, and the difference was statistically significant(P<0.05).
CONCLUSION
Both the surgery of internal fixation and total hip replacement have similar effect in short-and medium term among the patients aged 55 to 65 years old. However, for the reoperation rate, the group of internal fixation was higher than that of total hip replacement. For the subjective functional score of patients, the group of internal fixation was lower than that of total hip replacement.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Arthroplasty, Replacement, Hip/methods*
;
Treatment Outcome
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;