1.Automatic measurement of acetabular cup anteversion angle using an accurate recognition technology based on improved Otsu algorithm and feature point.
Qian LIU ; Yunqing MA ; Bo WU ; Yao ZHANG ; Jingwen QI ; Yuqian MEI
Journal of Biomedical Engineering 2025;42(3):592-600
The orientation of the acetabular cup in hip joint anteroposterior radiograph is a key factor in evaluating the postoperative outcomes of total hip arthroplasty (THA). Currently, measurement of the acetabular cup anteversion angle primarily relies on manual drawing of auxiliary lines by orthopedic surgeons and calculations using scientific calculators. This study proposes an automated computer-aided measurement method for the acetabular cup anteversion angle based on hip joint anteroposterior radiograph. The proposed method segments hip prosthesis images using an improved Otsu algorithm, identifies feature points at the acetabular cup opening by combining circle-fitting theory and the cup's geometric characteristics, and fits an ellipse to the cup opening to calculate the anteversion angle. A total of 104 hip joint anteroposterior radiographs, including 71 right-sided and 81 left-sided prostheses, were analyzed. Two orthopedic surgeons independently measured the postoperative anteversion angles, and the results were compared with computer-generated measurements for correlation analysis. Spearman and Pearson correlation analyses demonstrated significant correlations between the proposed method and manual measurements for both the right group ( r = 0.795, P < 0.01) and the left group ( r = 0.859, P < 0.01). This method provides a reliable reference for orthopedic surgeons to assess postoperative prognosis.
Humans
;
Acetabulum/anatomy & histology*
;
Arthroplasty, Replacement, Hip/methods*
;
Algorithms
;
Hip Prosthesis
;
Hip Joint/diagnostic imaging*
;
Radiography
;
Image Processing, Computer-Assisted/methods*
2.Study on assessment methods for acetabular cup size in total hip arthroplasty.
Jinzi WANG ; Wenju CHANG ; Pei ZHANG ; Xiang LI ; Yong ZHANG ; Shuoshuo ZHANG ; Hai DING
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):163-167
OBJECTIVE:
To evaluate precise assessment methods for predicting the optimal acetabular cup size in total hip arthroplasty (THA).
METHODS:
A clinical data of 73 patients (80 hips) who underwent primary THA between December 2022 and July 2024 and met the inclusion criteria was analyzed. There were 39 males and 34 females with an average age of 66.3 years (range, 56-78 years). Among them, 66 cases were unilateral THA and 7 were bilateral THAs. There were 29 patients (34 hips) of osteoarthritis, 35 patients (35 hips) of femoral neck fractures, and 9 patients (11 hips) of osteonecrosis of the femoral head. Based on anteroposterior pelvic X-ray films, three methods were employed to predict acetabular cup size, including preoperative template planning, radiographic femoral head diameter (FHD) measurement, and intraoperative FHD measurement. The predicted acetabular cup sizes from these methods were compared with the actual implanted sizes.
RESULTS:
The predicted acetabular cup sizes using the preoperative template planning, radiographic FHD measurement, and intraoperative FHD measurement were (51.25±2.81), (49.72±3.11), and (49.90±2.74) mm, respectively, compared to the actual implanted cup size of (50.57±2.74) mm, with no significant difference ( P>0.05). Regarding agreement with the actual implanted cup size, the preoperative template planning achieved exact matches in 35 hips (43.75%), one-size deviation in 41 hips (51.25%), and two-size deviations in 4 hips (5%); the radiographic FHD measurement achieved exact matches in 12 hips (15%), one-size deviation in 57 hips (71.25%), and two-size deviations in 11 hips (13.75%); and the intraoperative FHD measurement achieved exact matches in 26 hips (32.5%), one-size deviation in 52 hips (65%), and two-size deviations in 2 hips (2.5%). There were significant differences in agreement distributions between the three methods and the actual implanted cup sizes ( H=18.579, P<0.001).
CONCLUSION
The intraoperative FHD measurement, as a simple, cost-effective, and accurate method, effectively guides acetabular cup selection, reduces the risk of prosthesis wear, enhances postoperative joint stability.
Humans
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Male
;
Female
;
Middle Aged
;
Acetabulum/diagnostic imaging*
;
Aged
;
Hip Prosthesis
;
Prosthesis Design
;
Femur Head/surgery*
;
Osteoarthritis, Hip/surgery*
;
Radiography
;
Femoral Neck Fractures/surgery*
;
Femur Head Necrosis/surgery*
3.Effectiveness validation of a novel comprehensive classification for intertrochanteric fractures.
Lukuan CUI ; Hao LIU ; Jiangjing WANG ; Huanhuan FAN ; Dapeng WANG ; Shuhui WANG ; Chi SONG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):417-422
OBJECTIVE:
To validate the effectiveness of a novel comprehensive classification for intertrochanteric fracture (ITF).
METHODS:
The study included 616 patients with ITF, including 279 males (45.29%) and 337 females (54.71%); the age ranged from 23 to 100 years, with an average of 72.5 years. Two orthopaedic residents (observers Ⅰ and Ⅱ) and two senior orthopaedic surgeons (observers Ⅲ and Ⅳ) were selected to classify the CT imaging data of 616 patients in a random order by using the AO/Orthopaedic Trauma Association (AO/OTA) classification of 1996/2007 edition, the AO/OTA classification of 2018 edition, and the novel comprehensive classification method at an interval of 1 month. Kappa consistency test was used to evaluate the intra-observer and inter-observer consistency of the three ITF classification systems.
RESULTS:
The inter-observer consistency of the three classification systems evaluated by 4 observers twice showed that the 3 classification systems had strong inter-observer consistency. Among them, the κ value of the novel comprehensive classification was higher than that of the AO/OTA classification of 1996/2007 edition and 2018 edition, and the experience of observers had a certain impact on the classification results, and the inter-observer consistency of orthopaedic residents was slightly better than that of senior orthopaedic surgeons. The intra-observer consistency of two evaluations of three classification systems by 4 observers showed that the consistency of the novel comprehensive classification was better for the other 3 observers, except that the consistency of observer Ⅳ in the AO/OTA classification of 2018 version was slightly higher than that of the novel comprehensive classification. The results showed that the novel comprehensive classification has higher repeatability, and the intra-observer consistency of senior orthopaedic surgeons was better than that of orthopaedic residents.
CONCLUSION
The novel comprehensive classification system has good intra- and inter-observer consistency, and has high validity in the classification of CT images of ITF patients; the experience of observers has a certain impact on the results of the three classification systems, and those with more experiences have higher intra-observer consistency.
Male
;
Female
;
Humans
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Observer Variation
;
Reproducibility of Results
;
Hip Fractures/surgery*
;
Tomography, X-Ray Computed/methods*
;
Radiography
4.Treatment of femoral periprosthetic fracture of Vancouver type B1 and C with bridge combined internal fixation system.
Yi-Ping WENG ; Zhong-Jie YU ; Rong-Bin SUN ; Nan-Wei XU ; Yu ZHANG
China Journal of Orthopaedics and Traumatology 2020;33(4):371-375
OBJECTIVE:
To evaluate the clinical effect of bridge combined internal fixation system in the treatment of periprosthesis fracture of femur after hip replacement.
METHODS:
From October 2016 to June 2018, 5 patients of periprosthesis fractures of femur classified type B1 and type C in Vancouver were treated by open reduction and bridging combined with internal fixation, including 2 males and 3 females, with ages of 68, 70, 74, 75, 79 years;type B1 fractures in 4 and type C fractures in 1. Causes of injury:1 case of traffic injury, 4 cases of fall. After the operation, the patients were followed up for complications and fracture healing time by clinical and imaging examination, and Parker activity score was performed.
RESULTS:
The wounds of 5 patients healed without infection. One case of DVT was confirmed by venography. Five patients were followed up, and the durations were 2, 8, 9, 10, 15 months. One patient died of myocardial infarction 2 months after operation. The average healing time was 12.5 weeks. No loss of reduction or failure of internal fixation was found. Two patients could walk without protection and 1 patient needed to rely on single crutch. One case of periprosthetic fracture had to walk with a single crutch before operation and move indoors with two crutches after operation. The average Parker activity score was 51.8% before operation.
CONCLUSION
The bridge combined internal fixation system can be used to fix the fracture after hip replacement with stable femoral prosthesis.
Aged
;
Arthroplasty, Replacement, Hip
;
Bone Plates
;
Female
;
Femoral Fractures
;
surgery
;
Fracture Fixation, Internal
;
Fracture Healing
;
Humans
;
Male
;
Periprosthetic Fractures
;
surgery
;
Radiography
;
Reoperation
;
Retrospective Studies
;
Treatment Outcome
5.Application of soft tissue loosening and acetabular reconstruction in hip replacement for patients with severe femoral head necrosis.
Shuai LI ; Wei ZHU ; Zhengxiao OUYANG ; Dan PENG
Journal of Central South University(Medical Sciences) 2019;44(7):790-794
To explore the effect of application of soft tissue loosening and acetabular reconstruction in hip replacement for patients with severe femoral head necrosis on joint function.
Methods: From June 2012 to August 2016, 68 patients with severe femoral head necrosis (Ficat III, IV) underwent total hip replacement with soft tissue release and acetabular reconstruction at the Second Xiangya Hospital of Central South University. Total hip replacement is performed by the posterolateral approach. The acetabulum was rebuilt and the length of the affected limb was prolonged after clearing the scar tissue, proliferating the epiphysis, releasing the abductor muscle group and the adductor muscle group, dissecting the soft tissue around the acetabulum. One year after surgery, Harris score, X-ray positive lateral radiograph for the affected side and full-length X-ray examination for both lower extremities were performed to evaluate the curative effect.
Results: The postoperative follow-up time ranged from 1.0 to 5.5 years. All patients' femoral heads returned to normal anatomical position and the affected limb length was restored to 1.5-3.5 cm; all patients did not damage the sciatic nerve. The Harris scores for 68 patients increased from 38.6±7.5 to 78.2±5.7 (P=0.029) in the first year after surgery.
Conclusion: During hip replacement surgery for severe femoral head necrosis, soft tissue dissection and acetabular reconstruction can be used to ensure anatomical reconstruction for the acetabular fossa and to improve abductor function.
Acetabulum
;
Arthroplasty, Replacement, Hip
;
Femur Head
;
Femur Head Necrosis
;
surgery
;
Follow-Up Studies
;
Humans
;
Radiography
;
Treatment Outcome
6.The Frequency of Occult Intertrochanteric Fractures among Individuals with Isolated Greater Trochanteric Fractures
Jongho NOH ; Kee Haeng LEE ; Sehoon JUNG ; Sunwook HWANG
Hip & Pelvis 2019;31(1):23-32
PURPOSE: Isolated greater trochanteric (GT) fractures are often identified using plain radiography of patients with post-traumatic hip pain. In many cases, the fracture extends to form an occult intertrochanteric fracture. We conducted a study to determine the frequency of occult intertrochanteric fractures in patients diagnosed with isolated GT fractures using plain radiographs. MATERIALS AND METHODS: Among 3,017 individuals who visited our emergency department with a trauma-induced pertrochanteric femur fracture between July 2004 and March 2018, 100 patients diagnosed with isolated GT fractures using plain radiographs were retrospectively analyzed. Patients were divided into two groups, those with: i) isolated GT fractures (group A) and ii) occult intertrochanteric fractures (group B). In addition, plain radiographs, magnetic resonance imaging results, and treatment methods were further analyzed in each group. If surgery treatment was needed, it was performed by one surgeon, and in all cases, a 2-hole dynamic hip screw was used. RESULTS: Among the 100 cases of isolated GT fractures diagnosed using plain radiograph, additional examinations revealed that 10 (10.0%) were suffering from isolated GT fractures alone, while the remaining 90 (90.0%) were further diagnosed with occult intertrochanteric fracture. Gender, age, mechanism of injury, and bone mineral density did not correlate with fracture type. CONCLUSION: In our analysis, 90% of injuries initially diagnosed as isolated GT fractures were found to extend into occult intertrochanteric fractures upon further examination with additional imaging modalities. Therefore, additional evaluation should be performed to test for the potential presence of occult intertrochanteric fractures and to establish appropriate treatment plans.
Bone Density
;
Emergency Service, Hospital
;
Femur
;
Fractures, Closed
;
Hip
;
Hip Fractures
;
Humans
;
Magnetic Resonance Imaging
;
Radiography
;
Retrospective Studies
7.The earliest timing of ultrasound in screening for developmental dysplasia of the hips
Si Heng Sharon TAN ; Keng Lin WONG ; Andrew Kean Seng LIM ; James Hoipo HUI
Ultrasonography 2019;38(4):321-326
PURPOSE: The current study aimed to evaluate the results of ultrasound screening for developmental dysplasia of the hips (DDH) done at various weeks of life, to determine the earliest time that ultrasound screening can be performed reliably. METHODS: In this 17-year cohort study, all neonates who underwent ultrasound screening prior to the 12th week of life with subsequent follow-up radiography done at 1 year of life were included. The ultrasound images were evaluated according to the Graf classification, Harcke’s dynamic ultrasound screening method, and Terjesen’s femoral head coverage method. The radiographic images were evaluated according to the acetabular index and the femoral head position. The accuracy and correlation between the ultrasound findings from various weeks of life with the radiographic findings at 1 year of life were evaluated. RESULTS: A total of 348 neonates were included in the study, of whom 92 had abnormal ultrasound findings and 42 had abnormal radiographic findings at 1 year. Significant differences were identified between the findings of ultrasound screening examinations performed prior to the fourth week of life (day 21 and before) and the radiographic findings at 1 year of life (P<0.05). In contrast, no significant differences were identified when ultrasound screening was performed between the fourth and 12th weeks of life (day 22 and beyond) (P>0.05). The accuracy of ultrasound screening was 79.2% or higher when performed during or after the fourth week of life (day 22 and beyond). CONCLUSION: The earliest that ultrasound screening for DDH can be performed reliably is during the fourth week of life (day 22 and beyond).
Acetabulum
;
Classification
;
Cohort Studies
;
Follow-Up Studies
;
Head
;
Hip Dislocation
;
Hip
;
Humans
;
Infant, Newborn
;
Mass Screening
;
Methods
;
Radiography
;
Ultrasonography
8.Arthroscopic Treatment for Femoroacetabular Impingement with Extraspinal Diffuse Idiopathic Skeletal Hyperostosis
Jung Mo HWANG ; Deuk Soo HWANG ; Chan KANG ; Woo Yong LEE ; Gi Soo LEE ; Jeong Kil LEE ; Yun Ki KIM
Clinics in Orthopedic Surgery 2019;11(3):275-281
BACKGROUND: Patients with extraspinal diffuse idiopathic skeletal hyperostosis (DISH) involving the hip joint have symptoms like femoroacetabular impingement (FAI). To date, no reported study has determined the clinical outcomes of arthroscopic treatment in extraspinal DISH involving the hip joint. METHODS: A total of 421 hips with FAI that underwent arthroscopic treatment were reviewed retrospectively. We determined the extraspinal involvement of DISH with three-dimensional computed tomography (3D-CT) and simple radiography of the pelvis and hip joint. Clinical outcomes were evaluated at a minimum of 2 years postoperatively. The visual analog scale score (VAS), modified Harris hip score (MHHS), and hip outcome score–activity of daily living scale (HOS-ADL) were used, and hip range of motion (ROM) was evaluated pre- and postoperatively and at the time of the final follow-up. RESULTS: Among the 421 hips (372 patients) with FAI that underwent arthroscopic treatment, 17 hips (12 patients, 4.04%) had extraspinal DISH on the hip joints. The mean age of the patients was 51.5 years. The 3D-CT scans and simple radiographs showed extraspinal DISH on multiple points around the pelvis and hip joint. Nine of the 17 hips (seven of 12 patients) had spinal DISH. At the final follow-up, VAS, MHHS, and HOS-ADL improved significantly from 6.5, 65.3, and 66.6, respectively, to 1.2, 87.8, and 89.5, respectively, and hip flexion and internal rotation improved significantly from 97.7° and 7.9°, respectively, to 117.1° and 18.2°, respectively. CONCLUSIONS: This study has demonstrated that extraspinal DISH involving the hip joint could lead to FAI, and arthroscopic treatment could result in relief of symptoms, including pain and ROM limitation, in extraspinal DISH patients.
Arthroscopy
;
Femoracetabular Impingement
;
Follow-Up Studies
;
Hip
;
Hip Joint
;
Humans
;
Hyperostosis, Diffuse Idiopathic Skeletal
;
Pelvis
;
Radiography
;
Range of Motion, Articular
;
Retrospective Studies
;
Visual Analog Scale
9.Serum myostatin levels are associated with abdominal aortic calcification in dialysis patients
Su Mi LEE ; Seong Eun KIM ; Ji Young LEE ; Hyo Jin JEONG ; Young Ki SON ; Won Suk AN
Kidney Research and Clinical Practice 2019;38(4):481-489
BACKGROUND: Serum myostatin levels are increased according to renal function decline and myostatin may be a main mediator of chronic kidney disease–related sarcopenia. A previous study reported that serum myostatin level was negatively associated with abdominal aortic calcification (AAC) in older males. The aim of this study was to assess the association between serum myostatin level and AAC among dialysis patients of both sexes. In addition, we analyzed the relationship between serum myostatin level, muscle mass, and bone mineral density (BMD).METHODS: In this cross-sectional study, we evaluated AAC in the lateral lumbar spine using plain radiography and BMD in 71 patients undergoing dialysis. We classified patients into two groups according to the median value of myostatin as follows: those with high myostatin levels (≥ 5.0 ng/mL) and those with low myostatin levels (< 5.0 ng/mL).RESULTS: The proportion of patients with an AAC score of five points or more was higher among those with low myostatin levels. Myostatin level was negatively associated with AAC scores on plain radiography and had a positive association with skeletal muscle mass and T-scores for BMD measured at the total hip and femur neck. Lower myostatin levels were independently associated with higher AAC scores following adjustment for age, sex, diabetes mellitus, dialysis vintage, dialysis modality, and osteoprotegerin level.CONCLUSION: Lower serum myostatin levels were associated with higher AAC scores, lower muscle mass, and lower BMD in dialysis patients. Further, prospective studies and those with larger cohorts are necessary to validate these findings.
Bone Density
;
Cohort Studies
;
Cross-Sectional Studies
;
Diabetes Mellitus
;
Dialysis
;
Femur Neck
;
Hip
;
Humans
;
Kidney
;
Male
;
Muscle, Skeletal
;
Myostatin
;
Osteoprotegerin
;
Prospective Studies
;
Radiography
;
Sarcopenia
;
Spine
;
Vascular Calcification
10.Determinants of Hip and Femoral Deformities in Children With Spastic Cerebral Palsy.
Yoona CHO ; Eun Sook PARK ; Han Kyul PARK ; Jae Eun PARK ; Dong wook RHA
Annals of Rehabilitation Medicine 2018;42(2):277-285
OBJECTIVE: To find factors affecting hip and femoral deformities in children with spastic cerebral palsy (CP) by comparing various clinical findings with imaging studies including plain radiography and computed tomography (CT) imaging. METHODS: Medical records of 709 children with spastic CP who underwent thorough baseline physical examination and functional assessment between 2 to 6 years old were retrospectively reviewed. Fifty-seven children (31 boys and 26 girls) who had both plain radiography of the hip and three-dimensional CT of the lower extremities at least 5 years after baseline examination were included in this study. RESULTS: The mean age at physical examination was 3.6 years (SD=1.6; range, 2–5.2 years) and the duration of follow-up imaging after baseline examination was 68.4 months (SD=22.0; range, 60–124 months). The migration percentage correlated with motor impairment and the severity of hip adductor spasticity (R1 angle of hip abduction with knee flexion). The femoral neck and shaft angle correlated with the ambulation ability and severity of hip adductor spasticity (R1 and R2 angles of hip abduction with both knee flexion and extension). CONCLUSION: Hip subluxation and coxa valga deformity correlated with both dynamic spasticity and shortening of hip adductor muscles. However, we found no correlation between femoral deformities such as femoral anteversion, coxa valga, and hip subluxation.
Bone Anteversion
;
Cerebral Palsy*
;
Child*
;
Congenital Abnormalities*
;
Coxa Valga
;
Femur Neck
;
Follow-Up Studies
;
Hip Dislocation
;
Hip*
;
Humans
;
Knee
;
Lower Extremity
;
Medical Records
;
Muscle Spasticity*
;
Muscles
;
Physical Examination
;
Radiography
;
Retrospective Studies
;
Walking

Result Analysis
Print
Save
E-mail