1.Preliminary study on the relationship between the degree of transverse sinus stenosis and cerebral blood flow in normal adults based on four-dimensional flow MRI
Xu HAN ; Heyu DING ; Chihang DAI ; Xiaoyu QIU ; Yan HUANG ; Ruowei TANG ; Shusheng GONG ; Long JIN ; Zhenghan YANG ; Zhenchang WANG ; Pengfei ZHAO
Chinese Journal of Radiology 2025;59(3):269-276
Objective:To evaluate the relationship between transverse sinus stenosis (TSS) and cerebral blood flow in normal adults based on four-dimensional flow (4D Flow) MRI.Methods:The study was a cross-sectional study. Totally 81 normal volunteers who underwent magnetic resonance venography (MRV) and 4D Flow MRI were prospectively enrolled at Beijing Friendship Hospital, Capital Medical University from January 2020 to December 2022. Based on MRV evaluation of transverse sinus dysplasia, the volunteers were divided into a dysplasia group (26 cases) and a non-dysplasia group (55 cases); The area of the stenosis and the normal transverse sinus at the distal end were measured. The degree of TSS and the bilateral average transverse sinus stenosis (BA-TSS) were calculated. TSS was determined using TSS levels of 1/3, 1/2, and 2/3 as thresholds, and was divided into three groups: no TSS group, unilateral TSS group, and bilateral TSS group, with 28, 39, and 14 cases, 37, 37, and 7 cases, and 43, 36, and 2 cases, respectively. Based on 4D Flow MRI, the blood flow of the internal carotid artery, vertebral artery, superior sagittal sinus, straight sinus, and transverse sinus distal and proximal ends were measured. The cerebral blood flow (bilateral internal carotid artery blood flow+bilateral vertebral artery blood flow), venous sinus return blood flow 1 (superior sagittal sinus blood flow+straight sinus blood flow), return blood flow 2 (sum of bilateral transverse sinus distal end blood flow), return blood flow 3 (sum of bilateral transverse sinus proximal end blood flow), and the ratio of return blood flow to cerebral blood flow were calculated. Independent sample t-test was used to compare the differences between the group with and without transverse sinus dysplasia; Single factor analysis of variance was used to compare the differences between the TSS free group, unilateral TSS group, and bilateral TSS group. Based on single factor linear regression, the relationships between BA-TSS and blood flow parameters were analyzed.Results:There was no statistically significant difference in various blood flow parameters between the group with and without transverse sinus dysplasia (all P>0.05). When using 1/3, 1/2, and 2/3 as thresholds, there was no statistically significant difference in various blood flow parameters between the non TSS group, unilateral TSS group, and bilateral TSS group (all P>0.05). BA-TSS was linearly positively correlated with cerebral blood flow (β=0.986, 95% CI 0.108-1.865, P=0.028), but not linearly correlated with return blood flow 1, 2, and 3 (all P>0.05). The degree of BA-TSS was linearly negatively correlated with return blood flow 1/cerebral blood flow (β=-0.001, 95% CI -0.002-0, P=0.009) and return blood flow 2/cerebral blood flow (β=-0.001, 95% CI -0.002-0, P=0.018), but not with return blood flow 3/cerebral blood flow ( P=0.076). Conclusion:The BA-TSS degree in normal adults is positively correlated with cerebral blood inflow and negatively correlated with the proportion of venous sinus outflow.
2.A comparative study of ultra-high-resolution CT and multi-slice spiral CT showing the key sound transmission structures of the middle ear
Yufei SUN ; Ruowei TANG ; Heyu DING ; Ning XU ; Zhaohui ZHONG ; Zhenghan YANG ; Zhenchang WANG ; Pengfei ZHAO
Chinese Archives of Otolaryngology-Head and Neck Surgery 2025;32(4):225-228,233
OBJECTIVE To compare the ability of ultra-high-resolution CT(U-HRCT)and multi-slice spiral CT(MSCT)to display key vocal transmission structures in the middle ear.METHODS Subjects with normal middle ear structures who underwent 0.1 mm layer thickness U-HRCT and 0.625 mm layer thickness MSCT scans at the same time in Beijing Friendship Hospital affiliated to Capital Medical University from December 2019 to August 2024 were retrospectively enrolled.Two experienced head and neck radiologists reconstruct standard transsectional,coronal images based on the thinnest layer thickness.According to the 5-point method,16 key sound transmission structures of the middle ear,including malleus,incus and stapes,as well as joints,ligaments and tendons,were evaluated for image quality scoring.The standard deviation(SD)value,signal noise ratio(SNR),and contrast noise ratio(CNR)of bone in the malleus region and intratympanic gas were measured and calculated on the two examination images.RESULTS Thirty patients(47 sides)with normal middle ear structure were included,including 18 males and 12 females.The two physicians compared the results of U-HRCT in showing malleus head,malleus neck,malleus handle,incus body,long process,and short process,5 points accounted for 100%,and the 5-point scores of incudomalleolar joint space,incudostapedial joint space,stapes footplate and annular ligament were 100%,98.29%,75.83%and 77.83%,respectively,which were significantly higher than those of MSCT(P<0.001).In addition,U-HRCT showed higher scores for lenticular process,stapes head,anterior arch of stapes,posterior arch of stapes,annular ligament,stapes muscle,and tendo musculi tensoris tympani than MSCT(P<0.001),and the lenticular process showed a 100%display rate.There was no significant difference in the SNR between the two groups(P>0.05),but the SD value of the malleus in U-HRCT was 161.6±36.4,which was significantly lower than that in MSCT(297.8±128.1),and the difference was statistically significant(P<0.001).CONCLUSION U-HRCT can clearly visualize the key sound transmission structures of the middle ear,and its visualization ability is significantly better than that of MSCT.
3.New materials enable new functions:a review of the research progress of new ureteral stents from a fuctional perspective
Heyu YANG ; Weijun CHEN ; Yifeng XUE
Journal of Modern Urology 2025;30(8):712-715,725
As research on material functionality in ureteral stents continues to advance,novel ureteral stents not only effectively reduce the incidence of complications,but also exhibit a range of innovative functionalities.Novel ureteral stents with diverse functionalities have been developed through approaches such as replacing synthetic materials,applying new coatings,and modifying existing stent structures.These innovative designs include fiber-membrane composite stents,metal-nanomaterial stents,drug-eluting coated stents,and magnetic-tip stents.This article reviews the characteristics and current research status of ureteral stents based on their specialized applications,including the inhibition of bacterial infections,alleviation of stent-related symptoms,reduction of peri-stent calculi,assistance in the treatment of ureteral strictures,and other potential benefits.
4.New materials enable new functions:a review of the research progress of new ureteral stents from a fuctional perspective
Heyu YANG ; Weijun CHEN ; Yifeng XUE
Journal of Modern Urology 2025;30(8):712-715,725
As research on material functionality in ureteral stents continues to advance,novel ureteral stents not only effectively reduce the incidence of complications,but also exhibit a range of innovative functionalities.Novel ureteral stents with diverse functionalities have been developed through approaches such as replacing synthetic materials,applying new coatings,and modifying existing stent structures.These innovative designs include fiber-membrane composite stents,metal-nanomaterial stents,drug-eluting coated stents,and magnetic-tip stents.This article reviews the characteristics and current research status of ureteral stents based on their specialized applications,including the inhibition of bacterial infections,alleviation of stent-related symptoms,reduction of peri-stent calculi,assistance in the treatment of ureteral strictures,and other potential benefits.
5.Preliminary study on the relationship between the degree of transverse sinus stenosis and cerebral blood flow in normal adults based on four-dimensional flow MRI
Xu HAN ; Heyu DING ; Chihang DAI ; Xiaoyu QIU ; Yan HUANG ; Ruowei TANG ; Shusheng GONG ; Long JIN ; Zhenghan YANG ; Zhenchang WANG ; Pengfei ZHAO
Chinese Journal of Radiology 2025;59(3):269-276
Objective:To evaluate the relationship between transverse sinus stenosis (TSS) and cerebral blood flow in normal adults based on four-dimensional flow (4D Flow) MRI.Methods:The study was a cross-sectional study. Totally 81 normal volunteers who underwent magnetic resonance venography (MRV) and 4D Flow MRI were prospectively enrolled at Beijing Friendship Hospital, Capital Medical University from January 2020 to December 2022. Based on MRV evaluation of transverse sinus dysplasia, the volunteers were divided into a dysplasia group (26 cases) and a non-dysplasia group (55 cases); The area of the stenosis and the normal transverse sinus at the distal end were measured. The degree of TSS and the bilateral average transverse sinus stenosis (BA-TSS) were calculated. TSS was determined using TSS levels of 1/3, 1/2, and 2/3 as thresholds, and was divided into three groups: no TSS group, unilateral TSS group, and bilateral TSS group, with 28, 39, and 14 cases, 37, 37, and 7 cases, and 43, 36, and 2 cases, respectively. Based on 4D Flow MRI, the blood flow of the internal carotid artery, vertebral artery, superior sagittal sinus, straight sinus, and transverse sinus distal and proximal ends were measured. The cerebral blood flow (bilateral internal carotid artery blood flow+bilateral vertebral artery blood flow), venous sinus return blood flow 1 (superior sagittal sinus blood flow+straight sinus blood flow), return blood flow 2 (sum of bilateral transverse sinus distal end blood flow), return blood flow 3 (sum of bilateral transverse sinus proximal end blood flow), and the ratio of return blood flow to cerebral blood flow were calculated. Independent sample t-test was used to compare the differences between the group with and without transverse sinus dysplasia; Single factor analysis of variance was used to compare the differences between the TSS free group, unilateral TSS group, and bilateral TSS group. Based on single factor linear regression, the relationships between BA-TSS and blood flow parameters were analyzed.Results:There was no statistically significant difference in various blood flow parameters between the group with and without transverse sinus dysplasia (all P>0.05). When using 1/3, 1/2, and 2/3 as thresholds, there was no statistically significant difference in various blood flow parameters between the non TSS group, unilateral TSS group, and bilateral TSS group (all P>0.05). BA-TSS was linearly positively correlated with cerebral blood flow (β=0.986, 95% CI 0.108-1.865, P=0.028), but not linearly correlated with return blood flow 1, 2, and 3 (all P>0.05). The degree of BA-TSS was linearly negatively correlated with return blood flow 1/cerebral blood flow (β=-0.001, 95% CI -0.002-0, P=0.009) and return blood flow 2/cerebral blood flow (β=-0.001, 95% CI -0.002-0, P=0.018), but not with return blood flow 3/cerebral blood flow ( P=0.076). Conclusion:The BA-TSS degree in normal adults is positively correlated with cerebral blood inflow and negatively correlated with the proportion of venous sinus outflow.
6.Transverse sinus blood flow characteristics of pulsatile tinnitus with dehiscent sigmoid plate based on 4D flow MRI
Chihang DAI ; Heyu DING ; Han LYU ; Xiaoyu QIU ; Xiaoshuai LI ; Rong ZENG ; Guopeng WANG ; Zhenghan YANG ; Shusheng GONG ; Zhenchang WANG ; Pengfei ZHAO
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2024;59(9):897-901
Objective:To investigate the hemodynamic characteristics of transverse sinus with sigmoid sinus wall dehiscence (SSWD) of pulsatile tinnitus (PT) based on 4D flow MRI.Methods:Retrospective analysis was performed on all patients admitted to Beijing Friendship Hospital, Capital Medical University from January 2019 to January 2021 for dehiscent sigmoid plate pulsatile tinnitus. A total of 26 patients (sides) who met the criteria and underwent 4D flow MRI were included. A total of 26 subjects (46 sides), matched 1∶1 according to gender and age, were included in the normal healthy control group. Nonparametric rank sum test, Student′s t test, and ANOVA were performed by SPSS 19.0 software. Binary Logistic regression was applied to the data with statistical significance. Results:There were more patients with dominant drainage on the affected side in PT group than in control group (73.1% vs. 42.3%). The incidence of transverse with a focal intraluminal filling defect and tapered stenosis was higher than that in control group (21.7% vs. 69.2%; 17.4% vs. 42.3%). Average through-plane velocity and maximum through-plane velocity in PT group were higher than those in control group [(33.75±13.88) cm/s vs. (15.84±7.21) cm/s; (93.19±33.55) cm/s vs. (40.40±14.40) cm/s]. The middle part and proximal end of Flow avg (ml/s) in PT group were larger than those in control group [4.69 (2.87; 5.62) ml/s vs. 2.76 (1.67; 4.99) ml/s; 3.41 (2.16; 5.47) ml/s vs. 2.67 (1.68; 4.41) ml/s]. In control group, the velocity of transverse sinus changed relatively gently, while in PT group, the velocity of proximal sinus increased significantly. Binary Logistic regression showed that SSWD PT was independently correlated with proximal maximum flow velocity [ OR=1.086(1.029-1.146), P=0.003]. Conclusion:4D flow MRI showed that the dominant drainage and higher velocity at the proximal end of the transverse sinus might be an important hemodynamic characteristics of dehiscent sigmoid plate pulsatile tinnitus.
7.Establishment and application of an ORTCC model-based training system for orthopedic subspecialty nurses in the operating room
Heyu WU ; Ying YANG ; Qiong MA ; Shiyu ZHAO ; Juanjuan HU ; Qi ZHOU
Chinese Journal of Practical Nursing 2023;39(8):567-572
Objective:To explore the construction and clinical practice of the training system for nurses in operating room subspecialty based on ORTCC model (including objectives, rules, training, assessment and culture), and to provide theoretical and practical guidance for the development of nursing subspecialty in operating room.Methods:This was a quasi-experimental study. The Union Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology was convenient to select 23 operating room nurses who rotated in orthopedic surgery rooms from January 2019 to June 2020 as the control group, and the traditional training model for specialized nurses in operating rooms was adopted. From July 2020 to December 2021, the 24 operating room nurses rotating orthopedic surgery rooms were selected as the experimental group, and ORTCC teaching mode was adopted. The degree of mastery of theoretical knowledge, standardization of operation skills, correct rate of standard preventive implementation and satisfaction rate of doctors of operating room nurses under two different training methods were compared.Results:The theoretical score of operating room nurses increased from (84.71 ± 5.70) points in the control group to (92.68 ± 3.64) points in the experimental group, and the skill score increased from (90.17 ± 4.69) points in the control group to (95.43 ± 2.61) points in the experimental group, with statistical significance ( t = 13.76, 5.64, both P<0.01). The satisfaction rate of surgeons to nurses′ surgical cooperation ability communication, cooperation ability and emergency treatment ability increased from 82.61%(19/23), 73.91%(17/23) and 78.26%(18/23) in the control group to 100.00%(24/24), 95.83% (24/24) and 100.00% (24/24) in the experimental group, respectively, with statistically significant differences ( t = 4.56, 4.45, 5.84, all P<0.05). Conclusions:The training system of operating room subspecialty nurses based on ORTCC model is conducive to improving the theoretical knowledge mastery, standard operation skills and doctor satisfaction rate of operating room nurses to the specialty and subspecialty, providing training basis for the development of operating room subspecialty, and worthy of clinical promotion.
8.Lycorine alleviates oxaliplatin-induced chemotherapy induced pain in mice via reducing COX-2 /NLRP3 inflammatory signaling
Chenlu Guo ; Ji Wu ; Heyu Yang ; Min Xie ; Ling Liu
Acta Universitatis Medicinalis Anhui 2023;58(3):429-433,441
Objective:
To explore the effect and mechanism of lycorine on oxaliplatin ( OXA) induced chemotherapy pain in mice.
Methods :
40 mice were randomly divided into 4 groups,10 mice per group,which were respectively divided into control group,model group,administration group,and inhibitor group.A mouse model of chemotherapy induced pain was established by intraperitoneal injection of OXA for 5 consecutive days.Intrathecal administration of lycorine was performed.Behavioral changes and expression levels of inflammatory related proteins were detected .
Results :
Compared with control group,model group mice exhibited the increased number of spontaneous flinches,decreased mechanical nociceptive threshold,decreased movement distance and latency,and up-regulated expression levels of interleukin-1 β (IL-1 β) ,astrocytic marker glial fibrillary acidic protein ( GFAP) ,cyclooxygenase-2( COX-2) ,NOD-like receptor protein 3 ( NLRP3 ) ,cysteinyl aspartate and specific proteinase 1 ( Caspase- 1) .Compared with model group,lycorine administration reduced the number of spontaneous flinches,increased mechanical nociceptive threshold ,enhanced the movement distance and latency ,bound and reduced COX-2 expression,down-regulated the expression levels of IL-1 β , GFAP ,NLRP3 and Caspase-1.
Conclusion
Lycorine reduces COX-2 expression,inhibits NLRP3 inflammasome activation,suppresses spinal inflammation,consequently alleviates pain behaviors and improved motor ability of mice.
9.Influence factors and family burden analysis of bicycle injury among middle school students in Shanghai, 2017-2018
YANG Dongling, JI Heyu, ZHOU Yuefang, QU Shuangxiao, LUO Chunyan
Chinese Journal of School Health 2020;41(3):394-397
Objective:
To understand the influencing factors and family burden of bicycle injury among middle school students in Shanghai for bicycle injury prevention.
Methods:
Based on 1∶2 matched case-control design, students who were injured when cycling were selected from Shanghai student injury case reporting system during Sept. 2017 to Dec. 2018 as the case group. The same-sex control was selected from the same grade in the same school with the case. A total of 61 cases and 122 control were selected. Self-reported questionnaires were conducted by parents of children. Univariate and multivariate logistic regression were used to analyze the influencing factors of bicycle injury.
Results:
Poor eyesight (OR=2.27, 95%CI=1.02-5.07), lots of intersections near the residence (OR=2.00, 95%CI=1.00-3.98), and lots of cyclists near the residence (OR=2.15, 95%CI=1.06-4.36) were positively correlated with bicycle injuries among middle school students. About 34.43% and 8.20% of parents reckon bicycle injuries had a moderate impact on family economic, daily activities and recreational activities. Among the students with bicycle injury, 70.49% of the students were absent from school because of illness, and 36.07% of their parents missed work because of illness. The average absence time for school and working were 10.79 days and 3.03 days respectively. The total economic loss caused by the lack of work was 84 950 yuan, with an average of 1 393 yuan.
Conclusion
Bicycle injury of middle school students in Shanghai causes certain family burden. Poor eyesight, lots of intersections near the residence, lots of cyclists near the residence are positively correlated with bicycle injuries among middle school students.
10.High resolution CT in evaluation of anatomic relationship between labyrinth segment of facial canal and cochlea
Heyu DING ; Pengfei ZHAO ; Han LYU ; Xuehuan LIU ; Peng ZHANG ; Zheng WANG ; Mei JIN ; Hao WANG ; Zhenghan YANG ; Shusheng GONG ; Zhenchang WANG
Chinese Journal of Medical Imaging Technology 2018;34(3):331-334
Objective To investigate the value of high resolution CT (HRCT) in displaying the anatomic relationship between labyrinth segment of facial canal and cochlea.Methods Totally 110 patients (220 ears) who underwent HRCT were collected.The original images were transferred to workstation for image processing.MPR images were acquired.The anatomic relationship between labyrinth segment of facial canal and cochlea was observed in oblique coronal MPR images.The bony septum between labyrinth segment of facial canal and cochlea was assessed as definite defect (Type Ⅰ),doubtful defect (Type Ⅱ) or complete (Type Ⅲ),respectively.Results There were 71 ears (71/220,32.27%) of Type Ⅰ,diameters of bone fissure ranged from 0.3-1.3 mm (average diameters [0.64±0.26]mm),86 ears (86/220,39.09%) of Type Ⅱ and 63 ears (63/220,28.64%) of Type Ⅲ,with bony septum thickness ranged from 0.3-1.0 mm (average thickness [0.68±0.15]mm).No statistical difference of rates of the above three types was found between different genders,among age groups and between both side of ears (all P>0.05).Conclusion HRCT is a reliable method to show the anatomic relationship between labyrinth segment of facial canal and cochlea.


Result Analysis
Print
Save
E-mail