1.Advances in the regulation of orexigenic/anorexigenic neuropeptides and signaling pathways by metabolic bariatric surgery
Yangxingyun WANG ; Hengyu DUAN ; Ruibin LI
Chinese Journal of General Surgery 2025;34(10):2258-2264
Metabolic bariatric surgery is an effective intervention for obesity and related metabolic disorders.Beyond substantial weight reduction,it modulates orexigenic and anorexigenic neuropeptides and their signaling pathways to improve energy homeostasis and metabolic function.This review summarizes the regulatory effects of various bariatric procedures(such as Roux-en-Y gastric bypass and sleeve gastrectomy)on orexigenic neuropeptides and anorexigenic factors,highlighting the involvement of key signaling pathways including mTOR and AMPK.These mechanisms contribute to weight control,enhanced insulin sensitivity,and remission of metabolic diseases.By integrating central and peripheral regulatory processes,metabolic surgery provides new biological insights into individualized obesity management.Future research should focus on interindividual variability and long-term neuro-metabolic adaptations to optimize surgical outcomes and improve metabolic health.
2.Advances in the regulation of orexigenic/anorexigenic neuropeptides and signaling pathways by metabolic bariatric surgery
Yangxingyun WANG ; Hengyu DUAN ; Ruibin LI
Chinese Journal of General Surgery 2025;34(10):2258-2264
Metabolic bariatric surgery is an effective intervention for obesity and related metabolic disorders.Beyond substantial weight reduction,it modulates orexigenic and anorexigenic neuropeptides and their signaling pathways to improve energy homeostasis and metabolic function.This review summarizes the regulatory effects of various bariatric procedures(such as Roux-en-Y gastric bypass and sleeve gastrectomy)on orexigenic neuropeptides and anorexigenic factors,highlighting the involvement of key signaling pathways including mTOR and AMPK.These mechanisms contribute to weight control,enhanced insulin sensitivity,and remission of metabolic diseases.By integrating central and peripheral regulatory processes,metabolic surgery provides new biological insights into individualized obesity management.Future research should focus on interindividual variability and long-term neuro-metabolic adaptations to optimize surgical outcomes and improve metabolic health.
3.Research on calibration method of endoscopic liquid expansion pump
Jing HUANG ; Aowen DUAN ; Li YANG ; Xiaobo WEN ; Haijiang ZHU ; Anhai WEI ; Hengyu LONG ; Hehua ZHANG
China Medical Equipment 2024;21(10):194-197
A corresponding calibration method was proposed for the key performance parameters of the endoscopic liquid expansion pump,such as the pressure indication error,the flow rate indication error and the flow rate repeatability.4 different brands of endoscopic liquid expansion pumps in clinical use in the hospital were selected for calibration,and the feasibility of the calibration method was evaluated.In the pressure and flow range of the endoscope liquid expansion pump,3 calibration points of high,medium and low were selected,and each flow point was calibrated 3 times.The calibration results showed that the maximum error of pressure indication was 4.3%,the maximum error of flow indication was 9.3%,and the maximum repeatability of flow indication value was 0.8%,all of which met the technical requirements for the maximum allowable error of"Medical Endoscopes.Endoscope Functional Supply Units.Irrigation Pump"(YY/T 0864-2011)and"Calibration Specification for Syringe Pumps and Infusion Pumps"(JJF 1259-2018).The calibration method for endoscopic liquid expansion pump can improve the metrological traceability system of this type of equipment,ensure the accuracy and reliability of equipment values,improve product quality,and ensure medical safety.
4.Quality control testing and performance evaluation of polysomnography
Jing HUANG ; Li YANG ; Aowen DUAN ; Li XU ; Zhenwei DU ; Hengyu LONG ; Anhai WEI ; Kexin PAN
China Medical Equipment 2024;21(5):123-127
Objective:To research the quality control and testing methods of polysomnography and to ensure its safe and effective performance.Methods:A quality control testing method was designed for the main indicators of EEG signal,EMG signal,ECG signal,and pulse oxygen saturation of polysomnography.In August 2023,two polysomnography instruments of the same brand and different models(marked as Test Equipment A and Test Equipment B)in clinical use in Daping Hospital,Army Medical University were selected.The quality control testing of polysomnography instrument was conducted by using electroencephalogram calibration instrument and vital sign simulator to evaluate the reliability of the performance of polysomnography.Results:A quality control testing method was developed for quality control testing of polysomnography aiming at the repeatability of the indicated values of EEG signals,EMG signals,ECG signals,and pulse oxygen saturation of polysomnography.Except for the output value of 2 mV of the voltage measurement simulator of test equipment B,the relative error of the recorded data was-11%,and the parameters were out of tolerance,and the rest of the test data of test equipment A and test equipment B met the maximum limit output value of the national metrology verification regulations and the technical requirements of the equipment manufacturer.Conclusion:The quality control detection method of polysomnography can evaluate the performance parameters of the selected testing equipment A and testing equipment B,and provide technical support for the quality control detection and safe use of such equipment.
5.Research on calibration method of pressurization device of blood transfusion and infusion
Jing HUANG ; Han LUO ; Aowen DUAN ; Xiaobo WEN ; Haijiang ZHU ; Anhai WEI ; Hengyu LONG ; Yan HE
China Medical Equipment 2024;21(12):196-199
According to the parameters of main indicators of pressurization device of blood transfusion and infusion,the calibration method was designed based on key technical parameters,which included pressure indication error,pressure output velocity,pressure release velocity,pressure bag airtightness,and overpressure protection. Three used pressurization devices of blood transfusion and infusion with different brands (labeled as Test Equipment A,Test Equipment B,and Test Equipment C) were selected to conduct calibration in the hospital,so as to assess the feasibility of calibration method,and to provide technique reference for evaluating the parameters of the performance. The calibration methods of pressurization device of blood transfusion and infusion were formulated from five aspects:pressure indication error,pressure output velocity,pressure deflation velocity,pressure bag airtightness and overpressure protection of pressurization device of blood transfusion and infusion. The results showed that the calibration method for pressurization device of blood transfusion and infusion,and the pressure and time recorder equipped with standard instrument of calibration can effectively calibrate the performance parameters of pressurization device of blood transfusion and infusion. The recorded data can meet the maximum limit output value of the manufacturer's technical requirements. The calibration method of pressurization device of blood transfusion and infusion can improve the metrological traceability system of such equipment,and ensure the safety and effectiveness of equipment performance,and enhance product quality,and reduce risks of clinical use,and guarantee medical safety.
6.Research on calibration method of pressurization device of blood transfusion and infusion
Jing HUANG ; Han LUO ; Aowen DUAN ; Xiaobo WEN ; Haijiang ZHU ; Anhai WEI ; Hengyu LONG ; Yan HE
China Medical Equipment 2024;21(12):196-199
According to the parameters of main indicators of pressurization device of blood transfusion and infusion,the calibration method was designed based on key technical parameters,which included pressure indication error,pressure output velocity,pressure release velocity,pressure bag airtightness,and overpressure protection. Three used pressurization devices of blood transfusion and infusion with different brands (labeled as Test Equipment A,Test Equipment B,and Test Equipment C) were selected to conduct calibration in the hospital,so as to assess the feasibility of calibration method,and to provide technique reference for evaluating the parameters of the performance. The calibration methods of pressurization device of blood transfusion and infusion were formulated from five aspects:pressure indication error,pressure output velocity,pressure deflation velocity,pressure bag airtightness and overpressure protection of pressurization device of blood transfusion and infusion. The results showed that the calibration method for pressurization device of blood transfusion and infusion,and the pressure and time recorder equipped with standard instrument of calibration can effectively calibrate the performance parameters of pressurization device of blood transfusion and infusion. The recorded data can meet the maximum limit output value of the manufacturer's technical requirements. The calibration method of pressurization device of blood transfusion and infusion can improve the metrological traceability system of such equipment,and ensure the safety and effectiveness of equipment performance,and enhance product quality,and reduce risks of clinical use,and guarantee medical safety.