1.Regulating, implementing and evaluating AI in Singapore healthcare: AI governance roundtable's view.
Wilson Wen Bin GOH ; Cher Heng TAN ; Clive TAN ; Andrew PRAHL ; May O LWIN ; Joseph SUNG
Annals of the Academy of Medicine, Singapore 2025;54(7):428-436
INTRODUCTION:
An interdisciplinary panel, comprising professionals from medicine, AI and data science, law and ethics, and patient advocacy, convened to discuss key principles on regulation, implementation and evaluation of AI models in healthcare for Singapore.
METHOD:
The panel considered 14 statements split across 4 themes: "The Role and Scope of Regulatory Entities," "Regulatory Processes," "Pre-Approval Evaluation of AI Models" and "Medical AI in Practice". Moderated by a thematic representative, the panel deliberated on each statement and modified it until a majority agreement threshold is met. The roundtable meeting was convened in Singapore on 1 July 2024. While the statements reflect local perspectives, they may serve as a reference for other countries navigating similar challenges in AI governance in healthcare.
RESULTS:
Balanced testing approaches, differentiated regulatory standards for autonomous and assistive AI, and context-sensitive requirements are essential in regulating AI models in healthcare. A hybrid approach-integrating global standards with local needs to ensure AI comple-ments human decision-making and enhances clinical expertise-was recommended. Additionally, the need for patient involvement at multiple levels was underscored. There are active ongoing efforts towards development and refinement of AI governance guidelines and frameworks balancing between regulation and freedom. The statements defined therein provide guidance on how prevailing values and viewpoints can streamline AI implementation into healthcare.
CONCLUSION
This roundtable discussion is among the first in Singapore to develop a structured set of state-ments tailored for the regulation, implementation and evaluation of AI models in healthcare, drawing on interdisciplinary expertise from medicine, AI, data science, law, ethics and patient advocacy.
Singapore
;
Humans
;
Artificial Intelligence/standards*
;
Delivery of Health Care/organization & administration*
2.Psychological resilience among emergency medical teams in Singapore
Eunice Chan ; Jacqueline Tan ; David Teng ; Joy Quah ; Jimmy Lee ; Mathew Yeo ; Pek Jen Heng
Western Pacific Surveillance and Response 2025;16(3):11-15
Problem: Emergency medical teams (EMTs) responding to mass casualty incidents attend to casualties in a chaotic, high-pressure and resource-limited environment that is vastly different from their day-to-day work. The nature of mass casualty incidents and the work environment can impact psychological resilience, but the psychological resilience of members of EMTs has not been evaluated.
Context: In Singapore, EMTs are deployed from public hospitals, polyclinics and the Singapore Red Cross to disaster sites, where they triage, stabilize and treat casualties before evacuating them to public hospitals for further management.
Action: Twenty-four members of EMTs responded to a cross-sectional survey based on a psychological resilience tool developed for health-care rescuers involved in mass casualty incidents to evaluate their psychological resilience after a full-scale exercise involving an aviation accident. Respondents completed a psychological resilience tool that was developed by experts in disaster work and research using a modified Delphi approach. There were 27 items across eight domains: optimism, altruism, preparations for disaster rescue, social support, perceived control, self-efficacy, coping strategies and positive growth.
Outcome: The key observations from the survey were that (i) staff demonstrated a strong sense of altruism and had good social support; (ii) staff were not confident about their preparedness, and this led to a lack of optimism, perceived control and ability to deal with emotions; and (iii) it was necessary for respondents to reflect on their experience to find meaning to support growth after the deployment.
Discussion: Optimizing casualty survival and outcomes during mass casualty incidents requires not only excellent procedural training and robust standard operating procedures and work processes but also dedicated efforts to enhance the psychological resilience of members of EMTs.
3.Is non-contrast-enhanced magnetic resonance imaging cost-effective for screening of hepatocellular carcinoma?
Genevieve Jingwen TAN ; Chau Hung LEE ; Yan SUN ; Cher Heng TAN
Singapore medical journal 2024;65(1):23-29
INTRODUCTION:
Ultrasonography (US) is the current standard of care for imaging surveillance in patients at risk of hepatocellular carcinoma (HCC). Magnetic resonance imaging (MRI) has been explored as an alternative, given the higher sensitivity of MRI, although this comes at a higher cost. We performed a cost-effective analysis comparing US and dual-sequence non-contrast-enhanced MRI (NCEMRI) for HCC surveillance in the local setting.
METHODS:
Cost-effectiveness analysis of no surveillance, US surveillance and NCEMRI surveillance was performed using Markov modelling and microsimulation. At-risk patient cohort was simulated and followed up for 40 years to estimate the patients' disease status, direct medical costs and effectiveness. Quality-adjusted life years (QALYs) and incremental cost-effectiveness ratio were calculated.
RESULTS:
Exactly 482,000 patients with an average age of 40 years were simulated and followed up for 40 years. The average total costs and QALYs for the three scenarios - no surveillance, US surveillance and NCEMRI surveillance - were SGD 1,193/7.460 QALYs, SGD 8,099/11.195 QALYs and SGD 9,720/11.366 QALYs, respectively.
CONCLUSION
Despite NCEMRI having a superior diagnostic accuracy, it is a less cost-effective strategy than US for HCC surveillance in the general at-risk population. Future local cost-effectiveness analyses should include stratifying surveillance methods with a variety of imaging techniques (US, NCEMRI, contrast-enhanced MRI) based on patients' risk profiles.
Humans
;
Adult
;
Carcinoma, Hepatocellular/diagnostic imaging*
;
Liver Neoplasms/diagnostic imaging*
;
Cost-Effectiveness Analysis
;
Cost-Benefit Analysis
;
Quality-Adjusted Life Years
;
Magnetic Resonance Imaging/methods*
4.A Simplified GBR Treatment and Evaluation of Posterior Seibert Class I Ridge Defects via Bio-collagen and Platelet-Rich Fibrin:A Retrospective Study
Zhi WANG ; Yafeng ZHENG ; Jiaqi XU ; Qi JIA ; Heng Bo JIANG ; Eui-Seok LEE
Tissue Engineering and Regenerative Medicine 2024;21(6):959-967
BACKGROUND:
Classical guided bone regeneration (GBR) treatments can achieve favorable clinical results for ridge defects. However, extensive bone augmentation in the non-esthetic area in the posterior region for minor ridge defects is unnecessary. Therefore, this study used a collagen and Platelet-rich fibrin (PRF) mixture for bone augmentation on minor posterior ridge defects and evaluated the effects.
METHODS:
22 Seibert Class I ridge defects were treated with BC and covered with a PRF membrane (simplified guided bone regeneration, simplified GBR) and other 22 were treated with Bio-Oss and covered with Bio-Gide (classical GBR). Cone-beam computed tomography imaging was conducted 6 months post-surgery to compare the ridge’s horizontal width (HW) and buccal ridge’s horizontal width to assess the osteogenic effect. In addition, the buccal ridge contour morphology was studied and classified.
RESULTS:
The buccal ridge contour of simplified GBR was Type A in 14 cases, Type B in 7 cases, and Type C in 1 case and it of classical GBR was Type A in 11 cases, Type B in 8 cases, and Type C in 3 cases. The mean HW significantly increased by 1.50 mm of simplified GBR treatment, while it increased by 1.83 mm in classical GBR treatment.
CONCLUSION
The combined use of BC and PRF had a significant effect on bone augmentation and this treatment exhibited promising clinical results for correcting posterior Seibert Class I ridge defects. The morphological classification of the reconstructive effect in this study can be utilized in future clinical work.
5.Response to “The Value of Non-Clinical Applications of Artificial Intelligence in Radiology Should Be Noted”
Nicole Kessa WEE ; Kim-Ann GIT ; Wen-Jeng LEE ; Gaurang RAVAL ; Aziz PATTOKHOV ; Evelyn Lai Ming HO ; Chamaree CHUAPETCHARASOPON ; Chuapetcharasopon TOMIYAMA ; Kwan Hoong NG ; Cher Heng TAN
Korean Journal of Radiology 2024;25(12):1102-1103
6.Preparation and Evaluation of Poloxamer/Carbopol In-Situ Gel Loaded with Quercetin: In-Vitro Drug Release and Cell Viability Study
Pinxuan ZHENG ; Xueying LIU ; Yanqing JIAO ; Xuran MAO ; Zhaorong ZONG ; Qi JIA ; Heng Bo JIANG ; Eui-Seok LEE ; Qi CHEN
Tissue Engineering and Regenerative Medicine 2024;21(8):1153-1171
BACKGROUND:
Periodontitis is a severe chronic inflammatory disease, whose traditional systemic antimicrobial therapy faces great limitations. In-situ gels provide an effective solution as an emerging local drug delivery system.
METHODS:
In this study, the novel thermosensitive poloxamer/carbopol in-situ gels loaded with 20 lmol/L quercetin for the treatment of periodontitis were prepared by cold method. Thirteen batches of in-situ gels based on two independent factors (X1 : poloxamer 407 and X2 : carbopol 934P) were designed and optimized by the statistical method of central composite design (CCD). The transparency, pH, injectability, viscosity, gelation temperature, gelation time, elasticity modulus, degradation rate and in-vitro drug release studies of the batches were evaluated, and the percentage of drug release in the first hour, the time required for 90% drug release, gelation temperature, and gelation time were selected as dependent variables.
RESULTS:
These two independent factors significantly affected the four dependent variables (p < 0.05). The optimization result displayed that the optimized concentration of poloxamer 407 was 20.84% (w/v), and carbopol 934P was 0.5% (w/v). The optimized formulation showed a clear appearance (++), acceptable injectability (Pass), viscosity(151,798 mPa s), gelation temperature (36 °C), gelation time (213 s), preferable cell viability and cell proliferation, conformed to first-order release kinetics, and had a significant antibacterial effect.
CONCLUSIONS
The article demonstrates the great potential of the quercetin in-situ gel as an effective treatment for periodontitis.
7.Epidemiology of paediatric intensive care unit admissions, deaths and organ donation candidacy: A single-centre audit.
John Zhong Heng LOW ; Joel Kian Boon LIM ; Herng Lee TAN ; Rudimar Martinez FERNANDEZ ; Samsudin Bin NORDIN ; Yee Hui MOK ; Judith Ju-Ming WONG
Annals of the Academy of Medicine, Singapore 2024;54(1):17-26
INTRODUCTION:
There are limited reports on the epidemiology of paediatric intensive care unit (PICU) admissions, deaths and organ donation candidacy. We aimed to describe PICU admission characteristics and outcomes, determine risk factors for mortality, and perform an independent assessment of missed organ donation opportunities.
METHOD:
We adopted a clinical audit design recruiting consecutive patients admitted to a single-centre multidisciplinary PICU from June 2020 to December 2023. Clinical characteristics and outcomes of survivors and non-survivors were described. Multivariable regression was performed to identify independent risk factors for mortality. Organ donation candidacy was evaluated by an independent team based on the criteria by Singapore's National Organ Transplant Unit.
RESULTS:
There were 1766 PICU admissions with mean age ± standard deviation of 5.9 ± 6.0 years. Surgical admissions accounted for 707/1766 (40%), while the most common medical admission category was respiratory (416/1766; 23.6%). The majority of 983/1766 (55.7%) had a chronic comorbidity and 312/1766 (17.6%) were dependent on at least 1 medical technology device. Mortality occurred in 99/1766 (5.6%). After adjusting for elective admissions and admission category; comorbidity with adjusted odds ratio (aOR) 95% confidence interval (CI) 3.03 (1.54-5.96); higher Pediatric Index of Mortality 3 (PIM 3) score with aOR 1.06 (95% CI 1.04-1.08); and functional status scale with aOR 1.07 (95% CI 1.00-1.13) were associated with mortality. Among non-survivors, organ donor candidacy was 21/99 (21.2%) but successful organ donation occurred in only 2/99 (2.0%).
CONCLUSION
In this single-centre audit, comorbidities, PIM 3 score and functional impairment were associated with mortality. Efforts are needed to improve paediatric organ donation rates.
Humans
;
Male
;
Female
;
Tissue and Organ Procurement/statistics & numerical data*
;
Intensive Care Units, Pediatric/statistics & numerical data*
;
Child, Preschool
;
Child
;
Infant
;
Singapore/epidemiology*
;
Risk Factors
;
Patient Admission/statistics & numerical data*
;
Hospital Mortality
;
Adolescent
;
Medical Audit
;
Comorbidity
;
Clinical Audit
8.Response to “The Value of Non-Clinical Applications of Artificial Intelligence in Radiology Should Be Noted”
Nicole Kessa WEE ; Kim-Ann GIT ; Wen-Jeng LEE ; Gaurang RAVAL ; Aziz PATTOKHOV ; Evelyn Lai Ming HO ; Chamaree CHUAPETCHARASOPON ; Chuapetcharasopon TOMIYAMA ; Kwan Hoong NG ; Cher Heng TAN
Korean Journal of Radiology 2024;25(12):1102-1103
9.Preparation and Evaluation of Poloxamer/Carbopol In-Situ Gel Loaded with Quercetin: In-Vitro Drug Release and Cell Viability Study
Pinxuan ZHENG ; Xueying LIU ; Yanqing JIAO ; Xuran MAO ; Zhaorong ZONG ; Qi JIA ; Heng Bo JIANG ; Eui-Seok LEE ; Qi CHEN
Tissue Engineering and Regenerative Medicine 2024;21(8):1153-1171
BACKGROUND:
Periodontitis is a severe chronic inflammatory disease, whose traditional systemic antimicrobial therapy faces great limitations. In-situ gels provide an effective solution as an emerging local drug delivery system.
METHODS:
In this study, the novel thermosensitive poloxamer/carbopol in-situ gels loaded with 20 lmol/L quercetin for the treatment of periodontitis were prepared by cold method. Thirteen batches of in-situ gels based on two independent factors (X1 : poloxamer 407 and X2 : carbopol 934P) were designed and optimized by the statistical method of central composite design (CCD). The transparency, pH, injectability, viscosity, gelation temperature, gelation time, elasticity modulus, degradation rate and in-vitro drug release studies of the batches were evaluated, and the percentage of drug release in the first hour, the time required for 90% drug release, gelation temperature, and gelation time were selected as dependent variables.
RESULTS:
These two independent factors significantly affected the four dependent variables (p < 0.05). The optimization result displayed that the optimized concentration of poloxamer 407 was 20.84% (w/v), and carbopol 934P was 0.5% (w/v). The optimized formulation showed a clear appearance (++), acceptable injectability (Pass), viscosity(151,798 mPa s), gelation temperature (36 °C), gelation time (213 s), preferable cell viability and cell proliferation, conformed to first-order release kinetics, and had a significant antibacterial effect.
CONCLUSIONS
The article demonstrates the great potential of the quercetin in-situ gel as an effective treatment for periodontitis.
10.Position Statements of the Emerging Trends Committee of the Asian Oceanian Society of Radiology on the Adoption and Implementation of Artificial Intelligence for Radiology
Nicole Kessa WEE ; Kim-Ann GIT ; Wen-Jeng LEE ; Gaurang RAVAL ; Aziz PATTOKHOV ; Evelyn Lai Ming HO ; Chamaree CHUAPETCHARASOPON ; Noriyuki TOMIYAMA ; Kwan Hoong NG ; Cher Heng TAN
Korean Journal of Radiology 2024;25(7):603-612
Artificial intelligence (AI) is rapidly gaining recognition in the radiology domain as a greater number of radiologists are becoming AI-literate. However, the adoption and implementation of AI solutions in clinical settings have been slow, with points of contention. A group of AI users comprising mainly clinical radiologists across various Asian countries, including India, Japan, Malaysia, Singapore, Taiwan, Thailand, and Uzbekistan, formed the working group. This study aimed to draft position statements regarding the application and clinical deployment of AI in radiology. The primary aim is to raise awareness among the general public, promote professional interest and discussion, clarify ethical considerations when implementing AI technology, and engage the radiology profession in the ever-changing clinical practice. These position statements highlight pertinent issues that need to be addressed between care providers and care recipients. More importantly, this will help legalize the use of non-human instruments in clinical deployment without compromising ethical considerations, decision-making precision, and clinical professional standards. We base our study on four main principles of medical care—respect for patient autonomy, beneficence, non-maleficence, and justice.


Result Analysis
Print
Save
E-mail