1.Clinical efficacy of Fu's subcutaneous needling based on "multi-joint muscle spiral balance chain" theory for cervical vertigo and its effect on blood flow velocity of vertebral artery.
Meng GONG ; Zhixiang LIU ; Pei LI ; Renyan XIAO ; Peng JIA ; Hong GUO ; Song JIN
Chinese Acupuncture & Moxibustion 2025;45(1):13-18
OBJECTIVE:
To observe the clinical efficacy of Fu's subcutaneous needling based on "multi-joint muscle spiral balance chain" theory for cervical vertigo (CV) and its effect on blood flow velocity of vertebral artery.
METHODS:
A total of 60 patients with CV were randomized into a Fu's subcutaneous needling group and a medication group, 30 cases in each one. In the Fu's subcutaneous needling group, Fu's subcutaneous needling was delivered at Dazhui (GV14), the flexible tube was retained for 5 min after sweeping manipulation, and the treatment was given once every other day, 3 times a week for 3 weeks. In the medication group, betahistine mesylate tablet and diclofenac sodium dual-release enteric capsule were taken orally for continuous 3 weeks. Before treatment, after treatment, and in follow-up of one month after treatment completion, the scores of dizziness handicap inventory (DHI) and visual analogue scale (VAS) were observed; before and after treatment, the blood flow velocity of vertebral artery was measured by transcranial Doppler, and the clinical efficacy was evaluated after treatment in the two groups.
RESULTS:
After treatment and in follow-up, each item scores and total scores of DHI were decreased compared with those before treatment in the two groups (P<0.05); the VAS scores after treatment in the two groups, as well as the VAS score in follow-up of the Fu's subcutaneous needling group, were decreased compared with those before treatment (P<0.05). In the Fu's subcutaneous needling group, after treatment and in follow-up, the physical scores and the total scores of DHI, and the VAS scores were lower than those in the medication group (P<0.05); in follow-up, the emotional and functional scores of DHI were lower than those in the medication group (P<0.05). After treatment, the mean blood flow velocity (Vm) of the left vertebral artery (LVA) and the right vertebral artery (RVA) was increased compared with that before treatment in the two groups (P<0.05), and the Vm of LVA and RVA in the Fu's subcutaneous needling group was higher than that in the medication group (P<0.05). The total effective rate was 100.0% (30/30) in the Fu's subcutaneous needling group, which was superior to 73.3% (22/30) in the medication group (P<0.05).
CONCLUSION
Fu's subcutaneous needling based on the "multi-joint muscle spiral balance chain" theory can effectively alleviate the vertigo and neck pain, and improve the blood flow velocity of vertebral artery in CV patients, and has a long-term therapeutic effect.
Humans
;
Female
;
Male
;
Middle Aged
;
Acupuncture Therapy/instrumentation*
;
Vertebral Artery/physiopathology*
;
Adult
;
Vertigo/physiopathology*
;
Aged
;
Blood Flow Velocity
;
Treatment Outcome
;
Acupuncture Points
;
Young Adult
2.Effect of Temperature Cycle Preservation on Platelet Aggregation Rate and Routine Parameters.
Ju-Ling LIANG ; Zhi-Hao DENG ; Chuang-Jin ZHUO ; Lu HUANG ; Jing XU ; Wei-Jian WU
Journal of Experimental Hematology 2025;33(1):236-240
OBJECTIVE:
To compare and analyze the changes of aggregation rate and routine parameters of platelets stored in temperature cycle, cold storage at 4 ℃ and oscillating storage at 22 ℃, so as to provide more experimental data for platelet preservation methods.
METHODS:
Blood samples were collected at 5 time points on the 1st, 2nd, 3rd, 4th and 6th day after platelet cycling preservation at temperature, cold storage at 4 ℃, and oscillating storage at 22 ℃. Platelet maximum aggregation rate (MAR) and routine parameters including platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW) and platelet-larger cell ratio (P-LCR) were detected.
RESULTS:
The platelet MAR of three groups showed a significant decrease trend with the preservation time, the fastest decrease was in the 22 ℃ group, the slowest was in the 4 ℃ group, and the temperature cycle group was between the two groups. On the 3rd day of preservation, the platelet MAR in 4 ℃ group was still in the normal range (MAR>60%), while in temperature cycle group was about 50%, and in 22 ℃ group was the lowest. On the 4th day of preservation, platelet MAR in all the three groups was lower than 50%, and that in temperature cycle group was significantly lower than in 4 ℃ group but higher than in 22 ℃ group (both P < 0.05). On the 6th day of preservation, platelet MAR in the temperature cycle group was significantly lower than that in the 4 ℃ group ( P <0.05), but there was no statistically significant difference compared to 22 ℃ group (P >0.05). PLT values in the three groups were all significantly decreased with the preservation time extension, and were significantly lower than those in the early stage of preservation within 6 days (all P < 0.05). PDW in temperature cycle group had no significant change within 6 days of preservation, but MPV and P-LCR were significantly increased. MPV, PDW and P-LCR all decreased significantly in 4 ℃ group within 6 days of preservation but increased in 22 ℃ group. Under the same storage days, PLT value of temperature cycle group had no significant difference with that of 4 ℃ group and 22 ℃ group, while MPV, PDW and P-LCR values were significantly higher than 4 ℃ group but lower than 22 ℃ group (all P < 0.05).
CONCLUSION
The aggregation function and routine parameters changes of temperature circulating preserved platelets are between 4 and 22 ℃.
Humans
;
Platelet Aggregation
;
Blood Preservation/methods*
;
Temperature
;
Blood Platelets
;
Platelet Count
;
Mean Platelet Volume
;
Cryopreservation/methods*
;
Cold Temperature
3.Effects of Oridonin on Platelet Function and Related Mechanisms.
Yu LI ; Rong YAN ; Meng-Nan YANG ; Kang-Xi ZHOU ; Ke-Sheng DAI
Journal of Experimental Hematology 2025;33(4):1104-1112
OBJECTIVE:
To investigate the effects of oridonin on platelet function and related mechanisms.
METHODS:
Washed platelets from healthy adults and mice were incubated with different concentrations of oridonin (2.5, 5 and 10 μmol/L) in vitro . The surface expression level of P-selectin and the activation of integrin αIIbβ3 in platelets were detected by flow cytometry, and the aggregation ability of platelets under the stimulation by various agonists was detected by light transmission aggregometry. The expression of P-AKT (Ser473) was detected by protein immunoblotting. Arterial thrombosis model was established in mice with mesenteric injury induced by ferric chloride, and tail hemorrhage model was established by cutting off the tail of mice. The effect of intraperitoneal injection of oridonin (10 mg/kg) on thrombosis and haemostasis was tested.
RESULTS:
Oridonin inhibited platelet P-selectin expression and integrin αIIbβ3 activation. In the presence of different stimulants, oridonin inhibited platelet aggregation in a concentration-dependent manner. The phosphorylation level of AKT Ser473 was reduced in the groups treated with different concentrations of oridonin. Oridonin significantly prolonged the time of mesenteric artery thrombosis in mice, but did not affect the tail bleeding time.
CONCLUSION
Oridonin inhibits platelet activation, aggregation, and thrombosis by inhibiting AKT phosphorylation, and may be used as a potential antiplatelet drug.
Diterpenes, Kaurane/pharmacology*
;
Animals
;
Mice
;
Blood Platelets/drug effects*
;
Platelet Aggregation/drug effects*
;
P-Selectin/metabolism*
;
Thrombosis
;
Platelet Glycoprotein GPIIb-IIIa Complex/metabolism*
;
Proto-Oncogene Proteins c-akt/metabolism*
;
Humans
;
Phosphorylation
;
Platelet Activation/drug effects*
4.Optimization of flow rate and orientation of outflow graft at implantation for patients with left ventricular assist device.
Yongyi WANG ; Li SHI ; Shijun HU ; Xiao TAN ; Tianli ZHAO
Journal of Central South University(Medical Sciences) 2025;50(3):457-468
OBJECTIVES:
A ventricular assist device (VAD) is an electromechanical device used to assist cardiac blood circulation, which can be employed for the treatment of end-stage heart failure and is most commonly placed in the left ventricle. Despite enhancing perfusion performance, the implantation of left ventricular assist device (LVAD) transforms the local intraventricular flow and thus may increase the risk of thrombogenesis. This study aims to investigate fluid-particle interactions and thromboembolic risk under different LVAD configurations using three-dimensional (3D) reconstruction models, focusing on the effects of outflow tract orientation and blood flow rates.
METHODS:
A patient-specific end-diastolic 3D reconstruction model was initially constructed in stereo lithography (STL) format using Mimics software based on CT images. Transient numerical simulations were performed to analyze fluid-particle interactions and thromboembolic risks for LVAD with varying outflow tract orientations under 2 flow rates (4 L/min and 5 L/min), using particles of uniform size (2 mm), and a blood flow rate optimization protocol was implemented for this patient.
RESULTS:
When the LVAD flow rate was 5 L/min, helicity and flow stagnation of the blood flow increased the particle residence time (RT) and the risk of thrombogenesis of the aortic root. The percentage of particles traveling toward the brachiocephalic trunk was up to 20.33%. When the LVAD flow rate was 4 L/min, blood turbulence in the aorta was reduced, the RT of blood particles was shortened, and then the percentage of particles traveling toward the brachiocephalic trunk decreased to 10.54%. When the LVAD blood flow rate was 5 L/min and the direction of the outflow pipe was optimal, the RT of blood particles was shortened, and then the percentage of particles traveling toward the brachiocephalic trunk decreased to 11.22%. A 18-month follow-up observation of the patient revealed that the LVAD was in good working order and the patient had no complications related to the implantation of LVAD.
CONCLUSIONS
Implantation of LVAD results in a higher risk of cerebral infarction; When implanting LVAD with the same outflow tract direction, optimizing flow velocity and outflow tract can reduce the risk of cerebral infarction occurrence.
Heart-Assist Devices/adverse effects*
;
Humans
;
Heart Failure/physiopathology*
;
Blood Flow Velocity
;
Thromboembolism/prevention & control*
;
Models, Cardiovascular
;
Heart Ventricles/physiopathology*
;
Imaging, Three-Dimensional
5.Prognostic value of difference between hematocrit and albumin in patients with sepsis.
Shaobo WANG ; Bin HUANG ; Yuxin XU ; Bingyu WEI ; Rongfang LONG ; Ying QIU
Chinese Critical Care Medicine 2025;37(7):633-637
OBJECTIVE:
To investigate the value of difference between hematocrit (HCT) and albumin (Alb) in predicting the prognosis of patients with sepsis.
METHODS:
A retrospective study was conducted on the septic patients hospitalized at the First Affiliated Hospital of Guangxi Medical University from January to October in 2024. Clinical data including gender, age, body mass index (BMI), history of hypertension or diabetes, vital signs on admission, and sequential organ failure assessment (SOFA) score, acute physiology and chronic health evaluation II (APACHE II) score, blood lactic acid (Lac), oxygenation index (PaO2/FiO2), hemoglobin (Hb), white blood cell count (WBC), platelet count (PLT), lymphocyte count (LYM), HCT, Alb, difference between HCT and Alb, bilirubin, scrum creatinine (SCr), and fibrinogen (Fib) within 48 hours of admission were collected. The 28-day prognosis of patients was also recorded. Binary multivariate Logistic regression analysis was used to identify risk factors for 28-day death in patients with sepsis. The predictive efficacy of the difference between HCT and Alb on 28-day death was evaluated using the receiver operator characteristic curve (ROC curve).
RESULTS:
Among 180 enrolled septic patients, 140 survived and 40 died on 28 days. Compared with the survival group, the patients in the death group was significantly older (years old: 64±16 vs. 55±15, P < 0.05), and had higher SOFA score, APACHE II score, and SCr [SOFA score: 6 (4, 9) vs. 3 (2, 5), APACHE II score: 13 (10, 18) vs. 8 (6, 11), SCr (μmol/L): 136 (70, 416) vs. 77 (58, 126), all P < 0.05] as well as lower Hb, PLT, HCT, difference between HCT and Alb, and Fib within 48 hours of admission [Hb (g/L): 90±30 vs. 106±79, PLT (×109/L): 158 (57, 240) vs. 215 (110, 315), HCT: 0.258±0.081 vs. 0.333±0.077, difference between HCT and Alb: -6.52±7.40 vs. 1.07±7.63, Fib (g/L): 3.72±1.57 vs. 4.59±1.55, all P < 0.05]. No significant difference in gender, BMI, history of hypertension or diabetes, vital signs on admission, or other laboratory indicators was found between the two groups. Binary multivariate Logistic regression analysis revealed that age [odds ratio (OR) = 1.040, 95% confidence interval (95%CI) was 1.004-1.078, P = 0.030], APACHE II score (OR = 1.218, 95%CI was 1.038-1.430, P = 0.016), Hb (OR = 1.040, 95%CI was 1.014-1.068, P = 0.003), and difference between HCT and Alb (OR = 0.804, 95%CI was 0.727-0.889, P < 0.001) were independent risk factors for 28-day death of septic patients. ROC curve analysis showed that the area under the ROC curve (AUC) of difference between HCT and Alb for predicting 28-day death of septic patients was 0.764 (95%CI was 0.679-0.849, P < 0.001). A cut-off value of difference between HCT and Alb ≤ -5.35 yielded a sensitivity of 80.7% and specificity of 65.0%.
CONCLUSIONS
The difference between HCT and Alb at early admission is a valuable predictor of prognosis in septic patients. A difference ≤ -5.35 indicates an increased death risk of septic patients.
Humans
;
Prognosis
;
Sepsis/blood*
;
Retrospective Studies
;
Hematocrit
;
Serum Albumin/analysis*
;
Male
;
Female
;
Middle Aged
;
Aged
;
APACHE
6.In Vitro Hydrodynamic Performance Evaluation of Valve Repair System.
Liang CAI ; Yibin LI ; Shiwen LYU
Chinese Journal of Medical Instrumentation 2024;48(6):603-606
OBJECTIVE:
To meet the treatment requirements for mitral regurgitation disease, this study designed a novel valve repair system and evaluated its hydrodynamic performance.
METHODS:
A mitral regurgitation model was created. The valve repair system was loaded onto the regurgitation model, and pulsatile flow tests and steady backflow leakage tests were conducted.
RESULTS:
The pulsatile flow test results indicated that the percentage of reflux after product implantation was lower than that before implantation under different concentric outputs and reverse pressures. The average cross-valve pressure difference after implantation was less than 5 mmHg. The steady backflow leakage test results showed that as the reverse pressure increased, the leakage amount of the valve repair system after implantation also increased.
CONCLUSION
The developed valve repair system exhibits excellent hydrodynamic performance, suggesting the feasibility of its application in the treatment of clinical mitral regurgitation.
Hydrodynamics
;
Mitral Valve Insufficiency/surgery*
;
Mitral Valve/surgery*
;
Heart Valve Prosthesis
;
Pulsatile Flow
;
Heart Valve Prosthesis Implantation
7.Surgical treatment of heart failure in China: towards the era of artificial heart.
Chinese Journal of Surgery 2023;61(3):177-180
The number of patients with heart failure in China is large, and the proportion of patients with end-stage heart failure continues to increase. The clinical effect of guideline-directed medications therapy for end-stage heart failure is poor. Heart transplantation is the most effective treatment for end-stage heart failure. But it is faced with many limitations such as the shortage of donors. In recent years, the research and development of artificial heart in China has made great progress. Three devices have been approved by the National Medical Products Administration for marketing, and another one is undergoing pre-marketing clinical trial. Since 2017, more than 200 cases of ventricular assist device implantation have been carried out in more than 34 hospitals in China. Among them, 70 patients in Fuwai Hospital, Chinese Academy of Medical Sciences had a 2-year survival rate of 90%. The first patient has survived more than 5 years with the device. More efforts should be put into the training of standardized technical team and quality control. Further research should be carried out in the aspects of pulsatile blood flow pump, fully implanted cable-free device, and improved biomaterial with better blood compatibility.
Humans
;
Heart-Assist Devices
;
Heart Failure/surgery*
;
Heart, Artificial
;
Heart Transplantation
;
Pulsatile Flow
8.Mechanism of blood-activating and mass-dissipating Chinese patent medicine against hyperplasia of mammary glands and use with other medicine: a review.
Qi-Rui FAN ; Mei CHEN ; Xiao-Yi DONG ; Rui TAO ; Jing-Rui WANG ; Shun-Li XIA ; Tao HAN
China Journal of Chinese Materia Medica 2023;48(2):292-299
Caused by endocrine disorder, hyperplasia of mammary glands(HMG) tends to occur in the young with increasing incidence, putting patients at the risk of cancer and threatening the health of women. Therefore, the prevention and treatment of HMG is attracting more and more attention. Amid the modernization of traditional Chinese medicine(TCM), many scholars have found that Chinese patent medicine has unique advantages and huge potential in treatment of endocrine disorder. Particularly, Chinese patent medicine with the function of blood-activating and mass-dissipating, such as Xiaojin Pills and Xiaozheng Pills, has been commonly used in clinical treatment of HMG, which features multiple targets, obvious efficacy, small side effect, and ease of taking and carrying around. Clinical studies have found that the combination of Chinese patent medicine with other medicine can not only improve the efficacy and relieve symptoms such as hyperplasia and pain but also reduce the toxic and side effects of western medicine. Therefore, based on precious pharmacological research and clinical research, this study reviewed the mechanisms of blood-activating mass-dissipating Chinese patent medicine alone and in combination with other medicine, such as regulating levels of in vivo hormones and receptors, promoting apoptosis, inhibiting angiogenesis, improving hemorheology indexes, enhancing immunity, and boosting antioxidant ability. In addition, limitations and problems were summarized. Thereby, this study is expected to lay a theoretical basis for the further study and clinical application of blood-activating mass-dissipating Chinese patent medicine alone or in combination with other medicine against HMG.
Humans
;
Female
;
Hyperplasia/drug therapy*
;
Nonprescription Drugs
;
Mammary Glands, Human/pathology*
;
Medicine, Chinese Traditional
;
Hemorheology
;
Drugs, Chinese Herbal/therapeutic use*
9.Microfluidic Chip and Flow Cytometry for Examination of the Antiplatelet Effect of Ticagrelor.
Xiao-Jing HUANG ; Tian-Cong ZHANG ; Xue-Mei GAO ; Cui HE ; Xuan-Rong HUAN ; Yuan LI
Acta Academiae Medicinae Sinicae 2023;45(2):257-263
Objective To examine the antiplatelet effect of ticagrelor by microfluidic chip and flow cytometry under shear stress in vitro. Methods Microfluidic chip was used to examine the effect of ticagrelor on platelet aggregation at the shear rates of 300/s and 1500/s.We adopted the surface coverage of platelet aggregation to calculate the half inhibition rate of ticagrelor.The inhibitory effect of ticagrelor on ADP-induced platelet aggregation was verified by optical turbidimetry.Microfluidic chip was used to construct an in vitro vascular stenosis model,with which the platelet reactivity under high shear rate was determined.Furthermore,the effect of ticagrelor on the expression of fibrinogen receptor (PAC-1) and P-selectin (CD62P) on platelet membrane activated by high shear rate was analyzed by flow cytometry. Results At the shear rates of 300/s and 1500/s,ticagrelor inhibited platelet aggregation in a concentration-dependent manner,and the inhibition at 300/s was stronger than that at 1500/s (both P<0.001).Ticagrelor at a concentration ≥4 μmol/L almost completely inhibited platelet aggregation.The inhibition of ADP-induced platelet aggregation by ticagrelor was similar to the results under flow conditions and also in a concentration-dependent manner.Ticagrelor inhibited the expression of PAC-1 and CD62P. Conclusion We employed microfluidic chip to analyze platelet aggregation and flow cytometry to detect platelet activation,which can reveal the responses of different patients to ticagrelor.
Humans
;
Ticagrelor/pharmacology*
;
Platelet Aggregation Inhibitors/pharmacology*
;
Flow Cytometry/methods*
;
Microfluidics
;
Platelet Aggregation
10.Study on Platelet Adhesion and Aggregation Induced by Gradient Shear Stress Using Microfluidic Chip Technology.
Hai-Dong MA ; Cui HE ; Su-Rong DENG ; Ting-Ting ZHANG ; Yuan LI ; Tian-Cong ZHANG
Journal of Experimental Hematology 2023;31(2):495-502
OBJECTIVE:
To study the effect of gradient shear stress on platelet aggregation by microfluidic chip Technology.
METHODS:
Microfluidic chip was used to simulate 80% fixed stenotic microchannel, and the hydrodynamic behavior of the stenotic microchannel model was analyzed by the finite element analysis module of sollidwork software. Microfluidic chip was used to analyze the adhesion and aggregation behavior of platelets in patients with different diseases, and flow cytometry was used to detect expression of the platelet activation marker CD62p. Aspirin, Tirofiban and protocatechuic acid were used to treat the blood, and the adhesion and aggregation of platelets were observed by fluorescence microscope.
RESULTS:
The gradient fluid shear rate produced by the stenosis model of microfluidic chip could induce platelet aggregation, and the degree of platelet adhesion and aggregation increased with the increase of shear rate within a certain range of shear rate. The effect of platelet aggregation in patients with arterial thrombotic diseases were significantly higher than normal group (P<0.05), and the effect of platelet aggregation in patients with myelodysplastic disease was lower than normal group (P<0.05).
CONCLUSION
The microfluidic chip analysis technology can accurately analyze and evaluate the platelet adhesion and aggregation effects of various thrombotic diseases unde the environment of the shear rate, and is helpful for auxiliary diagnosis of clinical thrombotic diseases.
Humans
;
Microfluidics
;
Platelet Adhesiveness
;
Platelet Aggregation
;
Blood Platelets/metabolism*
;
Platelet Aggregation Inhibitors/pharmacology*
;
Platelet Activation/physiology*
;
Thrombosis

Result Analysis
Print
Save
E-mail