3.Circulating BMP-7 Level is Independent of Sarcopenia in Older Asian Adults
Ahin CHOI ; Ji Yeon BAEK ; Eunhye JI ; Il-Young JANG ; Hee-Won JUNG ; So Jeong PARK ; Yunju JO ; Eunju LEE ; Dongryeol RYU ; Beom-Jun KIM
Annals of Geriatric Medicine and Research 2025;29(1):75-82
Background:
In vitro and animal studies have demonstrated that bone morphogenetic protein-7 (BMP-7), renowned for its osteogenic properties, also exerts beneficial effects on muscle metabolism by enhancing myogenesis and reversing muscle atrophy. Despite being proposed as a common regulatory factor for both muscle and bone, the impact of BMP-7 on human muscle health has not been thoroughly investigated.
Methods:
This cross-sectional study involved 182 community-dwelling older adults who underwent a comprehensive geriatric assessment in South Korea. Sarcopenia was diagnosed using Asian-specific cutoffs, and serum BMP-7 levels were quantified via enzyme immunoassay.
Results:
The mean age of the participants was 72.2±7.3 years, with 62.6% being female. After adjustments for confounders, serum BMP-7 levels were not significantly different between individuals with and without sarcopenia, nor were there differences based on skeletal muscle mass, strength, or physical performance levels (p=0.423 to 0.681). Likewise, no correlations were detected between circulating BMP-7 levels and any sarcopenia assessment metrics such as skeletal muscle index, grip strength, gait speed, or chair stand completion times (p=0.127 to 0.577). No significant associations were observed between increases in serum BMP-7 concentrations and the risk of sarcopenia or poor muscle phenotypes (p=0.431 to 0.712). Stratifying participants into quartiles based on serum BMP-7 levels also indicated no differences in sarcopenia-related parameters (p=0.663 to 0.996).
Conclusion
Despite experimental evidence supporting BMP-7’s role in muscle metabolism, this study found no significant association between serum BMP-7 levels and clinical indicators of muscle health in older adults. These findings challenge the utility of serum BMP-7 as a biomarker for sarcopenia in this demographic.
4.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
5.Circulating BMP-7 Level is Independent of Sarcopenia in Older Asian Adults
Ahin CHOI ; Ji Yeon BAEK ; Eunhye JI ; Il-Young JANG ; Hee-Won JUNG ; So Jeong PARK ; Yunju JO ; Eunju LEE ; Dongryeol RYU ; Beom-Jun KIM
Annals of Geriatric Medicine and Research 2025;29(1):75-82
Background:
In vitro and animal studies have demonstrated that bone morphogenetic protein-7 (BMP-7), renowned for its osteogenic properties, also exerts beneficial effects on muscle metabolism by enhancing myogenesis and reversing muscle atrophy. Despite being proposed as a common regulatory factor for both muscle and bone, the impact of BMP-7 on human muscle health has not been thoroughly investigated.
Methods:
This cross-sectional study involved 182 community-dwelling older adults who underwent a comprehensive geriatric assessment in South Korea. Sarcopenia was diagnosed using Asian-specific cutoffs, and serum BMP-7 levels were quantified via enzyme immunoassay.
Results:
The mean age of the participants was 72.2±7.3 years, with 62.6% being female. After adjustments for confounders, serum BMP-7 levels were not significantly different between individuals with and without sarcopenia, nor were there differences based on skeletal muscle mass, strength, or physical performance levels (p=0.423 to 0.681). Likewise, no correlations were detected between circulating BMP-7 levels and any sarcopenia assessment metrics such as skeletal muscle index, grip strength, gait speed, or chair stand completion times (p=0.127 to 0.577). No significant associations were observed between increases in serum BMP-7 concentrations and the risk of sarcopenia or poor muscle phenotypes (p=0.431 to 0.712). Stratifying participants into quartiles based on serum BMP-7 levels also indicated no differences in sarcopenia-related parameters (p=0.663 to 0.996).
Conclusion
Despite experimental evidence supporting BMP-7’s role in muscle metabolism, this study found no significant association between serum BMP-7 levels and clinical indicators of muscle health in older adults. These findings challenge the utility of serum BMP-7 as a biomarker for sarcopenia in this demographic.
6.Post‑transplant cyclophosphamide plus anti‑thymocyte globulin decreased serum IL‑6 levels when compared with post‑transplant cyclophosphamide alone after haploidentical hematopoietic stem cell transplantation
Jeong Suk KOH ; Myung‑Won LEE ; Thi Thuy Duong PHAM ; Bu Yeon HEO ; Suyoung CHOI ; Sang‑Woo LEE ; Wonhyoung SEO ; Sora KANG ; Seul Bi LEE ; Chul Hee KIM ; Hyewon RYU ; Hyuk Soo EUN ; Hyo‑Jin LEE ; Hwan‑Jung YUN ; Deog‑Yeon JO ; Ik‑Chan SONG
Blood Research 2025;60():5-
Background:
Post-transplantation cyclophosphamide (PTCy) and anti-thymocyte globulin (ATG) are common pro‑ phylactic strategies for graft-versus-host disease (GVHD) after haploidentical hematopoietic stem cell transplantation (haplo-HSCT). Interleukin (IL)-6 is a surrogate marker for cytokine release syndrome (CRS) and acute GVHD.Method The clinical outcomes and complications of haplo-HSCT with PTCy plus ATG versus PTCy monotherapy were compared according to serum IL-6 levels at Chungnam National University Hospital (Daejeon, South Korea) from Jan‑ uary 2019 to February 2023.
Results:
Forty patients who underwent haplo-HSCT were analyzed. A significant difference in IL-6 levels was observed between the PTCy plus ATG and PTCy alone groups (7.47 ± 10.55 vs. 117.65 ± 127.67; p = 0.003). More patients in the PTCy plus ATG group had a CRS grade of 0 than in the PTCy alone group (p < 0.001). Serum IL-6 levels were associated with grades II–IV acute GVHD (r = 0.547, p < 0.001). The cumulative incidence (CI) of grades II–IV acute GVHD was significantly higher in the PTCy alone group (67.9% vs. 4.8%; p < 0.001). No significant difference in the CI for chronic GVHD was detected between the PTCy plus ATG and PTCy alone groups (72.1% vs. 82.0%; p = 0.730). The CI of 1-year non-relapse mortality was significantly higher in the PTCy alone group than in the PTCy plus ATG group (42.2% vs. 15.9%; p = 0.022). The 1-year overall survival (OS) was significantly better in the PTCy plus ATG group (75.9% vs. 35.3%; p = 0.011). The 1-year GVHD-free, relapse-free survival rate was 29.4% in the PTCy alone group and 54.0% in the PTCy plus ATG group (p = 0.038).
Conclusion
Serum IL-6 levels were higher in the PTCy alone group than in the PTCy plus ATG group. The addition of ATG before stem cell infusion affected IL-6 levels and reduced the incidences of CRS and grade II–IV acute GVHD in haplo-HSCT patients. This study suggests that PTCy plus ATG as GVHD prophylaxis in haplo-HSCT is beneficial in terms of clinical outcomes and complications of HSCT.
7.Target-Enhanced Whole-Genome Sequencing Shows Clinical Validity Equivalent to Commercially Available Targeted Oncology Panel
Sangmoon LEE ; Jin ROH ; Jun Sung PARK ; Islam Oguz TUNCAY ; Wonchul LEE ; Jung-Ah KIM ; Brian Baek-Lok OH ; Jong-Yeon SHIN ; Jeong Seok LEE ; Young Seok JU ; Ryul KIM ; Seongyeol PARK ; Jaemo KOO ; Hansol PARK ; Joonoh LIM ; Erin CONNOLLY-STRONG ; Tae-Hwan KIM ; Yong Won CHOI ; Mi Sun AHN ; Hyun Woo LEE ; Seokhwi KIM ; Jang-Hee KIM ; Minsuk KWON
Cancer Research and Treatment 2025;57(2):350-361
Purpose:
Cancer poses a significant global health challenge, demanding precise genomic testing for individualized treatment strategies. Targeted-panel sequencing (TPS) has improved personalized oncology but often lacks comprehensive coverage of crucial cancer alterations. Whole-genome sequencing (WGS) addresses this gap, offering extensive genomic testing. This study demonstrates the medical potential of WGS.
Materials and Methods:
This study evaluates target-enhanced WGS (TE-WGS), a clinical-grade WGS method sequencing both cancer and matched normal tissues. Forty-nine patients with various solid cancer types underwent both TE-WGS and TruSight Oncology 500 (TSO500), one of the mainstream TPS approaches.
Results:
TE-WGS detected all variants reported by TSO500 (100%, 498/498). A high correlation in variant allele fractions was observed between TE-WGS and TSO500 (r=0.978). Notably, 223 variants (44.8%) within the common set were discerned exclusively by TE-WGS in peripheral blood, suggesting their germline origin. Conversely, the remaining subset of 275 variants (55.2%) were not detected in peripheral blood using the TE-WGS, signifying them as bona fide somatic variants. Further, TE-WGS provided accurate copy number profiles, fusion genes, microsatellite instability, and homologous recombination deficiency scores, which were essential for clinical decision-making.
Conclusion
TE-WGS is a comprehensive approach in personalized oncology, matching TSO500’s key biomarker detection capabilities. It uniquely identifies germline variants and genomic instability markers, offering additional clinical actions. Its adaptability and cost-effectiveness underscore its clinical utility, making TE-WGS a valuable tool in personalized cancer treatment.
8.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
9.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
10.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.

Result Analysis
Print
Save
E-mail