1.A Genetically Confirmed Korean Case of CANVAS: Cerebellar Ataxia, Neuropathy, and Vestibular Areflexia Syndrome
Seung Hee LEE ; Hee-Jae JUNG ; Ji-Hee YOON ; Gu-Hwan KIM ; June-Young KOH ; Yuna LEE ; Young Seok JU ; Eun-Jae LEE ; Beom Hee LEE ; Young-Min LIM ; Hyunjin KIM
Journal of the Korean Neurological Association 2025;43(1):45-49
Cerebellar ataxia, neuropathy, and vestibular areflexia syndrome (CANVAS) is a neurodegenerative disorder caused by a biallelic expansion of pentanucleotide repeats in the RFC1 gene. Previous studies have reported up to 22% of patients with late-onset ataxia harbor this pathogenic repeat expansion. Despite its relatively high prevalence, CANVAS is often underdiagnosed because the disease is not well recognized and genetic testing is not performed in clinical practice. Here, we present a patient with characteristic clinical features, confirmed by genetic testing.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.A Genetically Confirmed Korean Case of CANVAS: Cerebellar Ataxia, Neuropathy, and Vestibular Areflexia Syndrome
Seung Hee LEE ; Hee-Jae JUNG ; Ji-Hee YOON ; Gu-Hwan KIM ; June-Young KOH ; Yuna LEE ; Young Seok JU ; Eun-Jae LEE ; Beom Hee LEE ; Young-Min LIM ; Hyunjin KIM
Journal of the Korean Neurological Association 2025;43(1):45-49
Cerebellar ataxia, neuropathy, and vestibular areflexia syndrome (CANVAS) is a neurodegenerative disorder caused by a biallelic expansion of pentanucleotide repeats in the RFC1 gene. Previous studies have reported up to 22% of patients with late-onset ataxia harbor this pathogenic repeat expansion. Despite its relatively high prevalence, CANVAS is often underdiagnosed because the disease is not well recognized and genetic testing is not performed in clinical practice. Here, we present a patient with characteristic clinical features, confirmed by genetic testing.
6.A Genetically Confirmed Korean Case of CANVAS: Cerebellar Ataxia, Neuropathy, and Vestibular Areflexia Syndrome
Seung Hee LEE ; Hee-Jae JUNG ; Ji-Hee YOON ; Gu-Hwan KIM ; June-Young KOH ; Yuna LEE ; Young Seok JU ; Eun-Jae LEE ; Beom Hee LEE ; Young-Min LIM ; Hyunjin KIM
Journal of the Korean Neurological Association 2025;43(1):45-49
Cerebellar ataxia, neuropathy, and vestibular areflexia syndrome (CANVAS) is a neurodegenerative disorder caused by a biallelic expansion of pentanucleotide repeats in the RFC1 gene. Previous studies have reported up to 22% of patients with late-onset ataxia harbor this pathogenic repeat expansion. Despite its relatively high prevalence, CANVAS is often underdiagnosed because the disease is not well recognized and genetic testing is not performed in clinical practice. Here, we present a patient with characteristic clinical features, confirmed by genetic testing.
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.Omission of Breast Surgery in Predicted Pathologic Complete Response after Neoadjuvant Systemic Therapy: A Multicenter, Single-Arm, Non-inferiority Trial
Ji-Jung JUNG ; Jong-Ho CHEUN ; Soo-Yeon KIM ; Jiwon KOH ; Jai Min RYU ; Tae-Kyung YOO ; Hee-Chul SHIN ; Sung Gwe AHN ; Seho PARK ; Woosung LIM ; Sang-Eun NAM ; Min Ho PARK ; Ku Sang KIM ; Taewoo KANG ; Jeeyeon LEE ; Hyun Jo YOUN ; Yoo Seok KIM ; Chang Ik YOON ; Hong-Kyu KIM ; Hyeong-Gon MOON ; Wonshik HAN ; Nariya CHO ; Min Kyoon KIM ; Han-Byoel LEE
Journal of Breast Cancer 2024;27(1):61-71
Purpose:
Advances in chemotherapeutic and targeted agents have increased pathologic complete response (pCR) rates after neoadjuvant systemic therapy (NST). Vacuum-assisted biopsy (VAB) has been suggested to accurately evaluate pCR. This study aims to confirm the non-inferiority of the 5-year disease-free survival of patients who omitted breast surgery when predicted to have a pCR based on breast magnetic resonance imaging (MRI) and VAB after NST, compared with patients with a pCR who had undergone breast surgery in previous studies.
Methods
The Omission of breast surgery for PredicTed pCR patients wIth MRI and vacuumassisted bIopsy in breaST cancer after neoadjuvant systemic therapy (OPTIMIST) trial is a prospective, multicenter, single-arm, non-inferiority study enrolling in 17 tertiary care hospitals in the Republic of Korea. Eligible patients must have a clip marker placed in the tumor and meet the MRI criteria suggesting complete clinical response (post-NST MRI size ≤ 1 cm and lesion-to-background signal enhancement ratio ≤ 1.6) after NST. Patients will undergo VAB, and breast surgery will be omitted for those with no residual tumor. Axillary surgery can also be omitted if the patient was clinically node-negative before and after NST and met the stringent criteria of MRI size ≤ 0.5 cm. Survival and efficacy outcomes are evaluated over five years.Discussion: This study seeks to establish evidence for the safe omission of breast surgery in exceptional responders to NST while minimizing patient burden. The trial will address concerns about potential undertreatment due to false-negative results and recurrence as well as improved patient-reported quality of life issues from the omission of surgery. Successful completion of this trial may reshape clinical practice for certain breast cancer subtypes and lead to a safe and less invasive approach for selected patients.
9.Evaluating the Validity and Reliability of the Korean Version of the Scales for Outcomes in Parkinson’s Disease–Cognition
Jinse PARK ; Eungseok OH ; Seong-Beom KOH ; In-Uk SONG ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Yoon-Joong KIM ; Jin Whan CHO ; Hyeo-Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Jee-Young LEE ; Ji Seon KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung KIM ; Jinyoung YOUN ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Joong-Seok KIM ; Ji-Young KIM
Journal of Movement Disorders 2024;17(3):328-332
Objective:
The Scales for Outcomes in Parkinson’s Disease–Cognition (SCOPA-Cog) was developed to assess cognition in patients with Parkinson’s disease (PD). In this study, we aimed to evaluate the validity and reliability of the Korean version of the SCOPACog (K-SCOPA-Cog).
Methods:
We enrolled 129 PD patients with movement disorders from 31 clinics in South Korea. The original version of the SCOPA-Cog was translated into Korean using the translation-retranslation method. The test–retest method with an intraclass correlation coefficient (ICC) and Cronbach’s alpha coefficient were used to assess reliability. Spearman’s rank correlation analysis with the Montreal Cognitive Assessment-Korean version (MOCA-K) and the Korean Mini-Mental State Examination (K-MMSE) were used to assess concurrent validity.
Results:
The Cronbach’s alpha coefficient was 0.797, and the ICC was 0.887. Spearman’s rank correlation analysis revealed a significant correlation with the K-MMSE and MOCA-K scores (r = 0.546 and r = 0.683, respectively).
Conclusion
Our results demonstrate that the K-SCOPA-Cog has good reliability and validity.
10.Historical Review and Future of Cardiac Xenotransplantation
Jiwon KOH ; Hyun Keun CHEE ; Kyung-Hee KIM ; In-Seok JEONG ; Jung-Sun KIM ; Chang-Ha LEE ; Jeong-Wook SEO
Korean Circulation Journal 2023;53(6):351-366
Along with the development of immunosuppressive drugs, major advances on xenotransplantation were achieved by understanding the immunobiology of xenograft rejection. Most importantly, three predominant carbohydrate antigens on porcine endothelial cells were key elements provoking hyperacute rejection: α1,3-galactose, SDa blood group antigen, and N-glycolylneuraminic acid. Preformed antibodies binding to the porcine major xenoantigen causes complement activation and endothelial cell activation, leading to xenograft injury and intravascular thrombosis. Recent advances in genetic engineering enabled knock-outs of these major xenoantigens, thus producing xenografts with less hyperacute rejection rates. Another milestone in the history of xenotransplantation was the development of co-stimulation blockaded strategy. Unlike allotransplantation, xenotransplantation requires blockade of CD40-CD40L pathway to prevent T-cell dependent B-cell activation and antibody production. In 2010s, advanced genetic engineering of xenograft by inducing the expression of multiple human transgenes became available.So-called ‘multi-gene’ xenografts expressing human transgenes such as thrombomodulin and endothelial protein C receptor were introduced, which resulted in the reduction of thrombotic events and improvement of xenograft survival. Still, there are many limitations to clinical translation of cardiac xenotransplantation. Along with technical challenges, zoonotic infection and physiological discordances are major obstacles. Social barriers including healthcare costs also need to be addressed. Although there are several remaining obstacles to overcome, xenotransplantation would surely become the novel option for millions of patients with end-stage heart failure who have limited options to traditional therapeutics.

Result Analysis
Print
Save
E-mail