1.Effect of Wearing Phospholipid-releasing Contact Lenses on Dry Eyes in Rabbits
Hyeon Jung KIM ; Sehie PARK ; Yun Kyoung RYU ; Jin Sun HWANG ; Sun Hee OH ; Jae Hwi LEE ; Gui Bae KIM ; Young Joo SHIN
Journal of the Korean Ophthalmological Society 2025;66(4):181-190
Purpose:
To investigate whether a new phospholipid-releasing soft contact lens can improve symptoms of dry eyes.
Methods:
The study used 2.5-3.0 kg New Zealand rabbits including both normal non-dry eye rabbits and dry eye rabbits, the latter having undergone electrocauterization of the meibomian glands to block the gland orifices. Each rabbit wore a control contact lens on one eye and a phospholipid-releasing contact lens on the other eye daily. Phospholipid-releasing and control contact lenses were provided by NEOVISION Co., Ltd. The parameters assessed included tear film break-up time, tear osmolarity, ocular surface staining, and central corneal thickness. After the experiment, the rabbits were euthanized and their conjunctival tissue was stained with Periodic Acid Schiff (PAS) to observe conjunctival goblet cells.
Results:
In both dry eye and normal non-dry eye rabbits, tear film break-up time was longer and tear osmolarity was lower when using the phospholipid-releasing contact lens compared to the control contact lens. The ocular surface remained unstained in normal non-dry eye rabbits while staining was observed in dry eye rabbits. There was no significant difference in central corneal thickness between the control and phospholipid-releasing contact lenses in either group. PAS staining showed no difference in conjunctival goblet cell density between the two lens types in normal non-dry eye rabbits. However, in dry eye rabbits, the conjunctival goblet cell density tended to be slightly higher with the phospholipid-releasing contact lens compared to the control lens.
Conclusions
Phospholipid-releasing contact lenses may help reduce dry eye symptoms and minimize contact lens-related complications by stabilizing the tear film and lowering tear osmolarity.
2.Effect of a Nursing Practice Environment, Nursing Performance on Retention Intention: Focused on the Mediating Effects of Nursing Professional Pride
Shin Hee KIM ; Mi Sook OH ; Yun Bok KWAK
Journal of Korean Academy of Nursing Administration 2025;31(1):64-74
Purpose:
The study aims to confirm the mediating effect of nursing professional pride in the relationship between nursing practice environment, nursing performance, and retention intention.
Methods:
A descriptive cross-sectional survey was conducted from December 13 to 31, 2021, involving 127 nurses. The following statistical analysis was conducted: t-test, ANOVA, Scheffé test, Pearson's correlation coefficient analysis, and Hayes Process Macro Model 4 (to test the mediating effect).
Results:
Nursing practice environment showed a significant positive correlation with nursing performance, retention intention, and nursing professional pride. Nursing practice performance showed a positive correlation with retention intention and nursing professional pride, and retention intention showed a significant positive correlation with nursing professional pride. The mediating effect of nursing professional pride was found in the effect of nurses' nursing practice environment on their retention intention. In addition, the mediating effect of nursing professional pride was found in the effect of nurses' nursing practice performance on their retention intention.
Conclusion
Through this study, it was confirmed that nursing professional pride is a major A factor affecting retention intention in the hospital. Therefore, in order to increase nurses' retention intention to remain in Hospital, the basis of basic data was presented for strategy development.
3.Group B Streptococcus Detection Rate and Clindamycin Resistance Among Reproductive-Age Women in Korea During 2003–2022
Areum SHIN ; Doo Ri KIM ; Ji-Hee SUNG ; Jinyoung YANG ; Suk-Joo CHOI ; Cheong-Rae ROH ; Tae Yeul KIM ; Hee Jae HUH ; Nam Yong LEE ; Soo-young OH ; Yae-Jean KIM
Journal of Korean Medical Science 2025;40(15):e29-
Background:
Group B Streptococcus (GBS) is one of the leading causes of neonatal earlyonset sepsis, resulting in high mortality and significant comorbidity. Intrapartum penicillin prophylaxis is recommended for pregnant women with GBS colonization to prevent vertical transmission. For pregnant women at high risk of anaphylaxis to penicillin, clindamycin is recommended only if the susceptibility of GBS isolates has been identified. We retrospectively examined the GBS detection rate and clindamycin resistance among Korean women of reproductive age over the last 20 years.
Methods:
Microbiologic studies using vaginal, vaginal–rectal or vaginal–perianal swabs from female patients 15–49 years of age during 2003–2022 were reviewed. Annual GBS detection rates and clindamycin resistance rates were calculated. The study period was divided into two periods (period 1, 2003–2015; period 2, 2016–2022) based on the introduction of universal culture-based GBS screening in our center in 2016. GBS detection rates and clindamycin resistance rates were compared between the periods using χ2 tests.
Results:
A total of 14,571 women were tested 16,879 times and GBS was isolated in 1,054 tests (6.2%), with 423 clindamycin-resistant isolates (40.1%). The GBS detection rate increased from 3.4% (301/8,869) in period 1 to 9.4% (2,753/8,010) in period 2 (P < 0.001). Even during period 1, the GBS detection rate was higher in 2009–2015 compared to 2003–2008 (P < 0.001). Clindamycin resistance rates have remained at similar levels since 2009, which were 39.5% (199/301) in period 1 and 40.2% (303/753) in period 2 (P = 0.833).
Conclusion
This study demonstrated that GBS detection rates in Korean women of reproductive age significantly increased almost three times during the twenty years of the study period, with a persistently high clindamycin resistance rate of up to 40%.
4.Quality of Life in Women With Gestational Diabetes Mellitus and Treatment Satisfaction Upon Intermittently Scanned Continuous Glucose Monitoring
Sookyung WON ; Hyeon Ji KIM ; Jee Yoon PARK ; Kyung Joon OH ; Sung Hee CHOI ; Hak Chul JANG ; Joon Ho MOON
Journal of Korean Medical Science 2025;40(15):e46-
Background:
To assess the quality of life (QoL) and treatment satisfaction with intermittently-scanned continuous glucose monitoring (isCGM) in women with gestational diabetes mellitus (GDM).
Methods:
This prospective observational study included 189 women with GDM who completed the Korean version of the Audit of Diabetes-Dependent Quality of Life Questionnaire (K-ADDQoL). Among them, 25 women who utilized isCGM between gestational weeks 30 and 34 completed the Korean version of the Diabetes Treatment Satisfaction Questionnaire change version (K-DTSQc) to evaluate their satisfaction with isCGM during pregnancy.
Results:
GDM had a negative impact on the perceived QoL in 89.4% of the women. All 19 domains of the K-ADDQoL were adversely influenced by GDM, with the most significant impact on the freedom to eat (weighted impact score, −6.98 ± 2.49, P < 0.001) and the least impact on the sex life (−0.25 ± 0.80, P = 0.008). Younger women and those treated with insulin perceived themselves as being more affected in their QoL due to GDM. Women perceived to have less effect on their QoL attributed to GDM exhibited higher ΔHbA1c one year after delivery (ΔHbA1c, 0.3 ± 0.4% vs. 0.0 ± 0.4% in less affected vs. more affected women). The utilization of isCGM improved treatment satisfaction (overall satisfaction score, 10.36 ± 9.21, P < 0.001), independent of glycemic control during pregnancy.
Conclusion
Although GDM negatively affects the perceived QoL during pregnancy, attentiveness to GDM management may have a positive impact on long-term glycemic control.Moreover, employing isCGM can enhance treatment satisfaction in women with GDM.
5.Effect of a Nursing Practice Environment, Nursing Performance on Retention Intention: Focused on the Mediating Effects of Nursing Professional Pride
Shin Hee KIM ; Mi Sook OH ; Yun Bok KWAK
Journal of Korean Academy of Nursing Administration 2025;31(1):64-74
Purpose:
The study aims to confirm the mediating effect of nursing professional pride in the relationship between nursing practice environment, nursing performance, and retention intention.
Methods:
A descriptive cross-sectional survey was conducted from December 13 to 31, 2021, involving 127 nurses. The following statistical analysis was conducted: t-test, ANOVA, Scheffé test, Pearson's correlation coefficient analysis, and Hayes Process Macro Model 4 (to test the mediating effect).
Results:
Nursing practice environment showed a significant positive correlation with nursing performance, retention intention, and nursing professional pride. Nursing practice performance showed a positive correlation with retention intention and nursing professional pride, and retention intention showed a significant positive correlation with nursing professional pride. The mediating effect of nursing professional pride was found in the effect of nurses' nursing practice environment on their retention intention. In addition, the mediating effect of nursing professional pride was found in the effect of nurses' nursing practice performance on their retention intention.
Conclusion
Through this study, it was confirmed that nursing professional pride is a major A factor affecting retention intention in the hospital. Therefore, in order to increase nurses' retention intention to remain in Hospital, the basis of basic data was presented for strategy development.
6.Effect of Wearing Phospholipid-releasing Contact Lenses on Dry Eyes in Rabbits
Hyeon Jung KIM ; Sehie PARK ; Yun Kyoung RYU ; Jin Sun HWANG ; Sun Hee OH ; Jae Hwi LEE ; Gui Bae KIM ; Young Joo SHIN
Journal of the Korean Ophthalmological Society 2025;66(4):181-190
Purpose:
To investigate whether a new phospholipid-releasing soft contact lens can improve symptoms of dry eyes.
Methods:
The study used 2.5-3.0 kg New Zealand rabbits including both normal non-dry eye rabbits and dry eye rabbits, the latter having undergone electrocauterization of the meibomian glands to block the gland orifices. Each rabbit wore a control contact lens on one eye and a phospholipid-releasing contact lens on the other eye daily. Phospholipid-releasing and control contact lenses were provided by NEOVISION Co., Ltd. The parameters assessed included tear film break-up time, tear osmolarity, ocular surface staining, and central corneal thickness. After the experiment, the rabbits were euthanized and their conjunctival tissue was stained with Periodic Acid Schiff (PAS) to observe conjunctival goblet cells.
Results:
In both dry eye and normal non-dry eye rabbits, tear film break-up time was longer and tear osmolarity was lower when using the phospholipid-releasing contact lens compared to the control contact lens. The ocular surface remained unstained in normal non-dry eye rabbits while staining was observed in dry eye rabbits. There was no significant difference in central corneal thickness between the control and phospholipid-releasing contact lenses in either group. PAS staining showed no difference in conjunctival goblet cell density between the two lens types in normal non-dry eye rabbits. However, in dry eye rabbits, the conjunctival goblet cell density tended to be slightly higher with the phospholipid-releasing contact lens compared to the control lens.
Conclusions
Phospholipid-releasing contact lenses may help reduce dry eye symptoms and minimize contact lens-related complications by stabilizing the tear film and lowering tear osmolarity.
7.Complete or incomplete revascularization in patients with left main culprit lesion acute myocardial infarction with multivessel disease: a retrospective observational study
Sun Oh KIM ; Hong-Ju KIM ; Jong-Il PARK ; Kang-Un CHOI ; Jong-Ho NAM ; Chan-Hee LEE ; Jang-Won SON ; Jong-Seon PARK ; Sung-Ho HER ; Ki-Yuk CHANG ; Tae-Hoon AHN ; Myung-Ho JEONG ; Seung-Woon RHA ; Hyo-Soo KIM ; Hyeon-Cheol GWON ; In-Whan SEONG ; Kyung-Kuk HWANG ; Seung-Ho HUR ; Kwang-Soo CHA ; Seok-Kyu OH ; Jei-Keon CHAE ; Ung KIM
Journal of Yeungnam Medical Science 2025;42(1):18-
Background:
Complete revascularization has demonstrated better outcomes in patients with acute myocardial infarction (AMI) and multivessel disease. However, in the case of left main (LM) culprit lesion AMI with multivessel disease, there is limited evidence to suggest that complete revascularization is better.
Methods:
We reviewed 16,831 patients in the Korea Acute Myocardial Infarction Registry who were treated from July 2016 to June 2020, and 399 patients were enrolled with LM culprit lesion AMI treated with percutaneous coronary intervention. We categorized the patients as those treated with complete revascularization (n=295) or incomplete revascularization (n=104). The study endpoint was major adverse cardiac and cerebrovascular events (MACCE), a composite of all-cause death, myocardial infarction, ischemia-driven revascularization, stent thrombosis, and stroke. We performed propensity score matching (PSM) and analyzed the incidence of MACCE at 1 year.
Results:
After PSM, the two groups were well balanced. There was no significant difference between the two groups in MACCE at 1 year (12.1% vs. 15.2%; hazard ratio, 1.28; 95% confidence interval, 0.60–2.74; p=0.524) after PSM. The components of MACCE and major bleeding were also not significantly different.
Conclusion
There was no significant difference in clinical outcomes between the groups treated with complete or incomplete revascularization for LM culprit lesion AMI with multivessel disease.
8.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
9.Effect of remimazolam on intraoperative hemodynamic stability in patients undergoing cerebrovascular bypass surgery: a prospective randomized controlled trial
Chang-Hoon KOO ; Si Un LEE ; Hyeong-Geun KIM ; Soowon LEE ; Yu Kyung BAE ; Ah-Young OH ; Young-Tae JEON ; Jung-Hee RYU
Korean Journal of Anesthesiology 2025;78(2):148-158
Background:
Maintenance of stable blood pressure (BP) during cerebrovascular bypass surgery is crucial to prevent cerebral ischemia. We compared the effect of remimazolam anesthesia with that of propofol-induced and desflurane-maintained anesthesia on intraoperative hemodynamic stability and the need for vasoactive agents in patients undergoing cerebrovascular bypass surgery.
Methods:
Sixty-five patients were randomized into remimazolam (n = 31, remimazolam-based intravenous anesthesia) and control groups (n = 34, propofol-induced and desflurane-maintained anesthesia). The primary outcome was the occurrence of intraoperative hypotension. The secondary outcomes included hypotension duration, lowest mean BP (MBP), generalized average real variability (ARV) of MBP, and consumption of phenylephrine, norepinephrine, or remifentanil.
Results:
Occurrence rate and duration of hypotension were significantly lower in the remimazolam group (38.7% vs. 73.5%, P = 0.005; 0 [0, 10] vs. 7.5 [1.25, 25] min, P = 0.008). Remimazolam also showed better outcomes for lowest MBP (78 [73, 84] vs. 69.5 [66.25, 75.8] mmHg, P < 0.001) and generalized ARV of MBP (1.42 ± 0.49 vs. 1.66 ± 0.52 mmHg/min, P = 0.036). The remimazolam group required less phenylephrine (20 [0, 65] vs. 100 [60, 130] μg, P < 0.001), less norepinephrine (162 [0, 365.5] vs. 1335 [998.5, 1637.5] μg, P < 0.001), and more remifentanil (1750 [1454.5, 2184.5] vs. 531 [431, 746.5] μg, P < 0.001) than the control group.
Conclusions
Remimazolam anesthesia may provide better hemodynamic stability during cerebrovascular bypass surgery than propofol-induced and desflurane-maintained anesthesia.
10.Feasibility of a Machine Learning Classifier for Predicting Post-Induction Hypotension in Non-Cardiac Surgery
Insun PARK ; Jae Hyon PARK ; Young Hyun KOO ; Chang-Hoon KOO ; Bon-Wook KOO ; Jin-Hee KIM ; Ah-Young OH
Yonsei Medical Journal 2025;66(3):160-171
Purpose:
To develop a machine learning (ML) classifier for predicting post-induction hypotension (PIH) in non-cardiac surgeries.
Materials and Methods:
Preoperative data and early vital signs were obtained from 3669 cases in the VitalDB database, an opensource registry. PIH was defined as sustained mean arterial pressure (MAP) <65 mm Hg within 20 minutes since induction or from induction to incision. Six different ML algorithms were used to create binary classifiers to predict PIH. The primary outcome was the area under the receiver operating characteristic curve (AUROC) of ML classifiers.
Results:
A total of 2321 (63.3%) cases exhibited PIH. Among ML classifiers, the random forest regressor and extremely gradient boosting regressor showed the highest AUROC, both recording a value of 0.772. Excluding these models, the light gradient boosting machine regressor showed the second highest AUROC [0.769; 95% confidence interval (CI), 0.767–0.771], followed by the gradient boosting regressor (0.768; 95% CI, 0.763–0.772), AdaBoost regressor (0.752; 95% CI, 0.743–0.761), and automatic relevance determination regression (0.685; 95% CI, 0.669–0.701). The top three important features were mean diastolic blood pressure (DBP), minimum MAP, and minimum DBP from anesthetic induction to tracheal intubation, and these features were lower in cases with PIH (all p<0.001).
Conclusion
ML classifiers exhibited moderate performance in predicting PIH, and have the potential for real-time prediction.

Result Analysis