2.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.
3.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
4.New-Onset Neuromyelitis Optica Spectrum Disorder during Pregnancy: A Case Report
So Hee LEE ; Seongheon KIM ; Se Jin LEE ; Sung Hun KIM ; Sunghun NA
Perinatology 2025;36(1):32-36
Neuromyelitis optica spectrum disorder (NMOSD) is a rare inflammatory disease that most often affects the optic nerves and spinal cord. We describe a case of 36-year-old woman presented at 13 weeks of gestation with 4 extremities paresthesia and weakness that had lasted for two months at her first visit to our hospital. She had two previous uncomplicated full-term vaginal deliveries and no significant medical or family history. Spine magnetic resonance imaging (MRI) showed extensive cervical cord lesion and aquaporin-4 antibodies were strongly positive, confirming the diagnosis of NMOSD. Initial management with high-dose corticosteroids and plasmapheresis was done and she showed substantial improvement, but she revisited hospital at 26 weeks of gestational age due to visual disturbance and aggravated weakness. Relapse of NMOSD was confirmed by spine MRI, so rituximab therapy was initiated at 28 weeks of gestational age for prevention of recurrence.The patient showed clinical improvement with no adverse effects and relapse of symptoms. She successfully delivered a healthy male infant at 39 weeks and 3 days of gestational age through uncomplicated vaginal delivery. This case demonstrates successful management of new-onset NMOSD during pregnancy using a multi-modal treatment approach including rituximab.
6.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.
7.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
8.New-Onset Neuromyelitis Optica Spectrum Disorder during Pregnancy: A Case Report
So Hee LEE ; Seongheon KIM ; Se Jin LEE ; Sung Hun KIM ; Sunghun NA
Perinatology 2025;36(1):32-36
Neuromyelitis optica spectrum disorder (NMOSD) is a rare inflammatory disease that most often affects the optic nerves and spinal cord. We describe a case of 36-year-old woman presented at 13 weeks of gestation with 4 extremities paresthesia and weakness that had lasted for two months at her first visit to our hospital. She had two previous uncomplicated full-term vaginal deliveries and no significant medical or family history. Spine magnetic resonance imaging (MRI) showed extensive cervical cord lesion and aquaporin-4 antibodies were strongly positive, confirming the diagnosis of NMOSD. Initial management with high-dose corticosteroids and plasmapheresis was done and she showed substantial improvement, but she revisited hospital at 26 weeks of gestational age due to visual disturbance and aggravated weakness. Relapse of NMOSD was confirmed by spine MRI, so rituximab therapy was initiated at 28 weeks of gestational age for prevention of recurrence.The patient showed clinical improvement with no adverse effects and relapse of symptoms. She successfully delivered a healthy male infant at 39 weeks and 3 days of gestational age through uncomplicated vaginal delivery. This case demonstrates successful management of new-onset NMOSD during pregnancy using a multi-modal treatment approach including rituximab.
9.Does the outcome of acupuncture differ according to the location of sham needling points in acupuncture trials for migraine? A systematic review and network meta-analysis.
Boram LEE ; Chan-Young KWON ; Hye Won LEE ; Arya NIELSEN ; L Susan WIELAND ; Tae-Hun KIM ; Stephen BIRCH ; Terje ALRAEK ; Myeong Soo LEE
Frontiers of Medicine 2025;19(1):53-63
Various acupuncture clinical trials have been conducted on migraine; however, the conclusions remain controversial especially when acupuncture was compared with sham acupuncture. Sham acupuncture is sometimes performed at the same acupuncture points used for verum acupuncture despite the evidence on acupuncture point specificity. Four databases were searched for sham acupuncture or waiting list-controlled acupuncture trials for migraine on December 25, 2023. Sham acupuncture was classified according to the needling points: sham acupuncture therapy at verum points (SATV) or at sham points (SATS). Network meta-analysis was performed based on the frequentist framework for headache pain intensity and response rate. A total of 18 studies involving 1936 participants were analyzed. Headache pain intensity and response rate were significantly improved in verum acupuncture compared with SATS. However, there was no significant difference between SATV and verum acupuncture. When comparing SATS and SATV, there was no significant difference in headache pain intensity and response rate; however, the results were in favor of SATV. The effect of the risk of bias on the certainty of evidence between verum and sham acupunctures was judged to be generally low. SATV should not be misused as a placebo control to evaluate the efficacy of acupuncture.
Humans
;
Migraine Disorders/therapy*
;
Acupuncture Therapy/methods*
;
Acupuncture Points
;
Treatment Outcome
;
Randomized Controlled Trials as Topic
10.Erratum: Korean Gastric Cancer Association-Led Nationwide Survey on Surgically Treated Gastric Cancers in 2023
Dong Jin KIM ; Jeong Ho SONG ; Ji-Hyeon PARK ; Sojung KIM ; Sin Hye PARK ; Cheol Min SHIN ; Yoonjin KWAK ; Kyunghye BANG ; Chung-sik GONG ; Sung Eun OH ; Yoo Min KIM ; Young Suk PARK ; Jeesun KIM ; Ji Eun JUNG ; Mi Ran JUNG ; Bang Wool EOM ; Ki Bum PARK ; Jae Hun CHUNG ; Sang-Il LEE ; Young-Gil SON ; Dae Hoon KIM ; Sang Hyuk SEO ; Sejin LEE ; Won Jun SEO ; Dong Jin PARK ; Yoonhong KIM ; Jin-Jo KIM ; Ki Bum PARK ; In CHO ; Hye Seong AHN ; Sung Jin OH ; Ju-Hee LEE ; Hayemin LEE ; Seong Chan GONG ; Changin CHOI ; Ji-Ho PARK ; Eun Young KIM ; Chang Min LEE ; Jong Hyuk YUN ; Seung Jong OH ; Eunju LEE ; Seong-A JEONG ; Jung-Min BAE ; Jae-Seok MIN ; Hyun-dong CHAE ; Sung Gon KIM ; Daegeun PARK ; Dong Baek KANG ; Hogoon KIM ; Seung Soo LEE ; Sung Il CHOI ; Seong Ho HWANG ; Su-Mi KIM ; Moon Soo LEE ; Sang Hyun KIM ; Sang-Ho JEONG ; Yusung YANG ; Yonghae BAIK ; Sang Soo EOM ; Inho JEONG ; Yoon Ju JUNG ; Jong-Min PARK ; Jin Won LEE ; Jungjai PARK ; Ki Han KIM ; Kyung-Goo LEE ; Jeongyeon LEE ; Seongil OH ; Ji Hun PARK ; Jong Won KIM ;
Journal of Gastric Cancer 2025;25(2):400-402

Result Analysis
Print
Save