1.Design of performance testing platfrom for proportional solenoid valves in ventilators
Long-ying YE ; Ming-kang TANG ; Pei-pei ZHANG ; Ke-sheng WANG ; Dan LING ; Qian-hong HE
Chinese Medical Equipment Journal 2025;46(1):13-19
Objective To design a performance testing platform to evaluate the working status and performance characteristics of the ventilator proportional solenoid valve.Methods The performance testing platform had its hardware including a high-pressure gas source,a pressure regulating valve,sensors and etc,and its software designed based on PyQt5 and composed of several modules for data acquisition,parameter setting,image display,indicator computation,result output and etc.Two kinds of proportional solenoid valves(Valve 1、Valve2)were selected for static and dynamic tests to verify the performance of the platform.Results The platform developed facilitated the proportional solenoid valve to carry out accurate computation of static and dynamic indicators at real time and time domain and waveform feature extraction of sensor data by precision control and data acquisition for the proportional solenoid valve.Static tests showed that Valve 1 gained advantages over Valve 2 in static flow characteristics involving in lowered repeatability,return error and offset while enhanced stability;dynamic tests indicated Valve 2 had rapid flow variations and significant flow fluctuation impacts,Valve 1 showed smooth dynamic response changes,and Valve 2 behaved better than Valve 1 in dynamic performance.Conclusion The testing platform developed comprehensively demonstrates the performance characteristics and working performance of the ventilator proportional solenoid valve,which is of great significance to enhance the reliability and safety of the ventilator.[Chinese Medical Equipment Journal,2025,46(1):13-19]
2.Acute extensive anterior myocardial infarction after medullary infarction:a case report
Pei-xun HE ; Yan-ming LIU ; Yi SUN ; Peng WU ; Lan WANG ; Xue-yong LI ; Jun-jie YANG ; Wei-nan ZHAO
Chinese Journal of Interventional Cardiology 2025;33(9):536-540
The medulla oblongata,situated at the caudal portion of the brainstem,serves as a critical regulatory center responsible for maintaining fundamental vital functions including respiratory and cardiovascular homeostasis.As a pivotal hub within the autonomic nervous system,it orchestrates the coordinated control of afferent and efferent neural pathways.Dysfunction of this region may precipitate life-threatening cardiorespiratory arrest,associated with substantial mortality rates.This case report presents a patient who developed acute extensive anterior myocardial infarction during treatment with dual antiplatelet therapy and moderate-intensity statins following acute medullary infarction.It is hypothesized that the pathogenesis may involve the acceleration of plaque erosion by the stroke-heart syndrome.This clinical case provides valuable insights into the complex neurocardiac interplay,particularly highlighting the imperative for enhanced recognition of brain-heart axis interactions in cerebrovascular pathology.
3.Comparison of clinical outcomes between modified posterolateral approach and traditional posterolateral approach internal fixation in treatment of trimalleolar fracture
Chao-ming HUANG ; Shao-xiang XIA ; Ru PEI ; Jie ZHANG ; Ren-hao HE
Journal of Regional Anatomy and Operative Surgery 2025;34(5):413-416
Objective To compare the clinical outcomes of modified posterolateral approach and traditional posterolateral approach combined with open reduction and internal fixation via medial approach in treatment of trimalleolar fracture.Methods Sixty-two patients with trimalleolar fractures who underwent modified posterolateral approach combined with open reduction and internal fixation via medial approach from January 2019 to June 2022 in orthopedics department of our hospital were enrolled in the modified approach group,and 62 patients who underwent traditional posterolateral approach combined with open reduction and internal fixation via medial approach at the same period were matched as the traditional approach group.The perioperative indicators were collected.The range of ankle motion 12 months after surgery was measured.The Maryland score,American Orthopaedic Foot and Ankle Society(AOFAS)score and Baird-Jackson score were employed to evaluate the recovery of patients 12 months after surgery,and the occurence of complications was recorded.Results There was no significant difference in the operation time,intraoperative blood loss,incision length,postoperative drainage volume or pain score between the two groups(P<0.05).The Maryland scores,AOFAS scores and Baird-Jackson scores 12 months after surgery of the two groups were higher than those before operation(P<0.05),while there was no significant difference between the two groups(P<0.05).The range of ankle motion in the modified approach group was better than that in the traditional approach group,and the incidence of nerve injury after surgery was lower than that in the traditional approach group,with statistically significant differences(P<0.05).Conclusions The modified posterolateral approach combined with open reduction and internal fixation via medial approach in treatment of trimalleolar fracture can achieve good early clinical outcome,effectively improve range of ankle motion,and reduce postoperative nerve injury.
4.Acute extensive anterior myocardial infarction after medullary infarction:a case report
Pei-xun HE ; Yan-ming LIU ; Yi SUN ; Peng WU ; Lan WANG ; Xue-yong LI ; Jun-jie YANG ; Wei-nan ZHAO
Chinese Journal of Interventional Cardiology 2025;33(9):536-540
The medulla oblongata,situated at the caudal portion of the brainstem,serves as a critical regulatory center responsible for maintaining fundamental vital functions including respiratory and cardiovascular homeostasis.As a pivotal hub within the autonomic nervous system,it orchestrates the coordinated control of afferent and efferent neural pathways.Dysfunction of this region may precipitate life-threatening cardiorespiratory arrest,associated with substantial mortality rates.This case report presents a patient who developed acute extensive anterior myocardial infarction during treatment with dual antiplatelet therapy and moderate-intensity statins following acute medullary infarction.It is hypothesized that the pathogenesis may involve the acceleration of plaque erosion by the stroke-heart syndrome.This clinical case provides valuable insights into the complex neurocardiac interplay,particularly highlighting the imperative for enhanced recognition of brain-heart axis interactions in cerebrovascular pathology.
5.Multicolor Fluorescent Copper Nanoclusters/Starch Composites and Their Application in Fingermark Development
Chuan-Jun YUAN ; Ming LI ; Yi-Fei SUN ; Jia-Ming LYU ; Zhi-Bo GAO ; Shi-Qiang SUN ; Pei-Liang HAN ; Feng-He LIU
Chinese Journal of Analytical Chemistry 2025;53(1):55-64,中插1-中插3
On the basis of that the fluorescence wavelength of copper nanoclusters(CuNCs)could cover the entire visible region,multicolor fluorescent CuNCs/starch composites were prepared and applied in fingermark development.With L-glutathione as the reducing agent and protective ligand,blue emissive and orange emissive CuNCs solutions were obtained in alkaline solutions at 90℃and 25℃,respectively.With the aggregation-induced emission effect induced by ethanol as a poor solvent,the fluorescence of orange emissive CuNCs with a higher intensity was achieved in an ethanol-water solution.With ascorbic acid as the reducing agent and 3-mercaptopropionic acid as the protective agent,green emissive CuNCs solution was prepared in an acid solution.Particle morphologies,chemical compositions and optical properties of these three CuNCs above were investigated using physical characterization and spectroscopic analysis,indicating that well-dispersed CuNCs had excellent photoluminescent properties.These CuNCs solutions were combined with starch to form composite powders by simply drying.The influences of the type of CuNCs and the ratio of CuNCs to starch on the emission wavelength and fluorescence intensity of the products were studied.The obtained CuNCs/starch composites could emit blue,green and orange fluorescence under 365 nm ultraviolet light,respectively,which were suitable for fingermark development.Minutiae and partial level-3 features of latent fingermarks could be effectively developed.High-quality fluorescence fingermark images would be captured using appropriate optical filters to eliminate background interference of various substrates.
6.Comparison of clinical outcomes between modified posterolateral approach and traditional posterolateral approach internal fixation in treatment of trimalleolar fracture
Chao-ming HUANG ; Shao-xiang XIA ; Ru PEI ; Jie ZHANG ; Ren-hao HE
Journal of Regional Anatomy and Operative Surgery 2025;34(5):413-416
Objective To compare the clinical outcomes of modified posterolateral approach and traditional posterolateral approach combined with open reduction and internal fixation via medial approach in treatment of trimalleolar fracture.Methods Sixty-two patients with trimalleolar fractures who underwent modified posterolateral approach combined with open reduction and internal fixation via medial approach from January 2019 to June 2022 in orthopedics department of our hospital were enrolled in the modified approach group,and 62 patients who underwent traditional posterolateral approach combined with open reduction and internal fixation via medial approach at the same period were matched as the traditional approach group.The perioperative indicators were collected.The range of ankle motion 12 months after surgery was measured.The Maryland score,American Orthopaedic Foot and Ankle Society(AOFAS)score and Baird-Jackson score were employed to evaluate the recovery of patients 12 months after surgery,and the occurence of complications was recorded.Results There was no significant difference in the operation time,intraoperative blood loss,incision length,postoperative drainage volume or pain score between the two groups(P<0.05).The Maryland scores,AOFAS scores and Baird-Jackson scores 12 months after surgery of the two groups were higher than those before operation(P<0.05),while there was no significant difference between the two groups(P<0.05).The range of ankle motion in the modified approach group was better than that in the traditional approach group,and the incidence of nerve injury after surgery was lower than that in the traditional approach group,with statistically significant differences(P<0.05).Conclusions The modified posterolateral approach combined with open reduction and internal fixation via medial approach in treatment of trimalleolar fracture can achieve good early clinical outcome,effectively improve range of ankle motion,and reduce postoperative nerve injury.
7.Design of performance testing platfrom for proportional solenoid valves in ventilators
Long-ying YE ; Ming-kang TANG ; Pei-pei ZHANG ; Ke-sheng WANG ; Dan LING ; Qian-hong HE
Chinese Medical Equipment Journal 2025;46(1):13-19
Objective To design a performance testing platform to evaluate the working status and performance characteristics of the ventilator proportional solenoid valve.Methods The performance testing platform had its hardware including a high-pressure gas source,a pressure regulating valve,sensors and etc,and its software designed based on PyQt5 and composed of several modules for data acquisition,parameter setting,image display,indicator computation,result output and etc.Two kinds of proportional solenoid valves(Valve 1、Valve2)were selected for static and dynamic tests to verify the performance of the platform.Results The platform developed facilitated the proportional solenoid valve to carry out accurate computation of static and dynamic indicators at real time and time domain and waveform feature extraction of sensor data by precision control and data acquisition for the proportional solenoid valve.Static tests showed that Valve 1 gained advantages over Valve 2 in static flow characteristics involving in lowered repeatability,return error and offset while enhanced stability;dynamic tests indicated Valve 2 had rapid flow variations and significant flow fluctuation impacts,Valve 1 showed smooth dynamic response changes,and Valve 2 behaved better than Valve 1 in dynamic performance.Conclusion The testing platform developed comprehensively demonstrates the performance characteristics and working performance of the ventilator proportional solenoid valve,which is of great significance to enhance the reliability and safety of the ventilator.[Chinese Medical Equipment Journal,2025,46(1):13-19]
8.Comparative study of total knee arthroplasty assisted by robot and remote sensing navigation system
Hai TANG ; Hong-Mei ZHANG ; Peng-Cheng SHAN ; Pei-Yan HU ; Lin JING ; Qi YAN ; Yuan-Yuan LI ; Xin-Yue WANG ; Si-Ye LIU ; Ming-Jiang HE
China Journal of Orthopaedics and Traumatology 2024;37(9):862-869
Objective To compare clinical efficacy of robot-assisted(RA)and remote sensing navigation alignment(RSNA)system-assisted total knee arthroplasty(TKA).Methods From March 2023 to June 2023,60 patients who underwent the first unilateral TKA due to severe knee osteoarthritis(KOA)were admitted and divided into RSNA group and RA group according to different treatment methods,with 30 patients in each group.There were 5 males and 25 females in RSNA group,aged from 56 to 81 years old with an average of(66.33±7.16)years old;body mass index(BM1)ranged from 19.87 to 38.54 kg·m-2 with an average of(28.40±6.18)kg·m-2;the courses of disease ranged from 5 to 36 months with an average of(18.20±8.98)months;RSNA system was used to assist the positioning of osteotomy.There were 7 males and 23 females in RA group,aged from 55 to 82 years old with an average of(67.83±8.61)years old;BMI ranged from 19.67 to 37.25 kg·m-2 with an aver-age of(28.01±4.89)kg·m-2;the courses of disease ranged from 3 to 33 months with an average of(17.93±9.20)months;RA was performed.Operation time,incision length,latent blood loss at 2 weeks after operation and incidence of lower extremity thrombosis were compared between two groups.Hip-knee ankle angle(HKAA),HKAA deviation,lateral distal femoral angle(LDFA),medial proximal tibial angle(MPTA)and posterior tibial slope(PTS)were compared between two groups;Western Ontario McMaster Universities Osteoarthritis Index(WOMAC)and Knee Society score(KSS)were used to evaluate functional recovery before operation,3 and 6 months after operation.Results The operation was performed successfully in both groups,and there were no serious complications such as vascular and nerve injury during operation.The wound healed well at stage Ⅰafter operation,and the follow-up time was 6 months.The operation time,latent blood loss at 2 weeks after operation and inci-sion length in RSNA group were(94.35±5.75)min,(130.54±17.53)mland(14.73±2.14)cm,respectively;while(102.57±6.88)min,(146.33±19.47)ml and(16.78±2.32)cm in RA group,respectively.RSNA group was better than RA group(P<0.05).No deep vein thrombosis occurred in both groups at 2 weeks after operation,5 patients occurred intermuscular vein throm-bosisin in RSNA group and 8 patients in RA group,the difference was not statistically significant(P>0.05).In RSNA group,HKAA,LDFA and MPTA were(173.00±5.54)°,(86.96±3.45)°,(82.79±3.35)° before operation,and(178.34±1.85)°,(89.92±0.42)°,(89.84±0.73)° at 1 week after operation,respectively.In RA group,HKAA,LDFA and MPTA were(173.31±6.48)°,(87.15±3.40)° and(82.99±3.05)° before operation,and(178.52±1.79)°,(90.03±0.39)° and(90.15±0.47)° at 1 week after operation,respectively.HKAA,LDFA and MPTA were significantly improved in both groups at 1 week after oper-ation(P<0.05).There were no significant difference in HKAA,LDFA,MPTA and PTS between two groups before operation and 1 week after operation(P>0.05).There was no significant difference in deviation distribution of HKAA at 1 week after op-eration(x2=2.61 1,P=0.456).There were no significant difference in WOMAC and KSS between two groups before operation,3 and 6 months after operation(P>0.05),and postoperative WOMAC and KSS at 3 and 6 months between two groups were im-proved compared with those before operation(P<0.05).Conclusion Both RA and RSNA system assisted TKA could obtain ac-curate osteotomy,RA has higher surgical accuracy,RSNA system assisted operation has less trauma,and operation is simpler.
9.Application of remote sensing navigation system in total knee arthroplasty
Yuan-Yuan LI ; Ming-Jiang HE ; Peng-Cheng SHAN ; Pei-Yan HU ; Lin JING ; Qi YAN ; Hai TANG ; Xin-Yue WANG ; Si-Ye LIU ; Hong-Mei ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(9):878-885
Objective To explore clinical accuracy of remote sensing navigation alignment(RSNA)system in total knee arthroplasty(TKA)and its influence on postoperative clinical efficacy.Methods From May 2021 to May 2022,60 knee os-teoarthritis(KOA)patients with Kellgren-Lawrence(K-L)grade Ⅲ to Ⅳ treated by unilateral primary TKA were selected and divided into RSNA group and traditional operation group according to treatment methods,and 30 patients in each group.There were 6 males and 24 females in RSNA group,aged from 55 to 86 years old with an average of(68.06±8.23)years old;body mass index(BMI)ranged from 22.15 to 34.58 kg·m-2 with an average of(28.20±3.01)kg·m-2;the courses of disease ranged from 2 to 60 months with an average of(18.80±14.80)months;13 patients with grade Ⅲ and 17 patients with grade Ⅳaccording to K-L grading.In traditional operation group,there were 8 males and 22 females,aged from 57 to 85 years old with an average of(67.26±6.32)years old;BMI ranged from 23.94 to 34.55 kg·m-2 with an average of(27.49±2.32)kg·m-2;the courses of disease ranged from 3 to 60 months with an average of(21.30±16.44)months;14 patients with grade Ⅲ and 16 pa-tients with grade Ⅳ according to K-L grading.Western Ontario and McMaster Universities(WOMAC)osteoarthritis index and Knee Society score(KSS)were used to evaluate functional recovery of patients.Hip-knee-ankle angle(HKAA),distal femoral valgus angle(FVA)and distal fermoral flexion angle(DFFA)were measured before operation.HKAA and HKAA deviation angle were measured at 1 week after operation,and defective rate of lower limb force line,femur prosthesis valgus angle(FP-VA)and femoral prosthesis flexion angle(FPFA),respectively,were calculated.Results There were no serious complications such as vascular and nerve injury during operation,and wound healed at stage Ⅰ.Both groups were followed up for 6 months.There were no significant difference in WOMAC index,KSS,HKAA,FVA and DFFA between two groups before operation(P>0.05).The force line defect rate,HKAA,HKAA deviation angle,FPVA deviation angle and FPFA of RSNA group were 6.7%,(178.74±1.56)°,(1.25±1.56)°,(1.84±0.16)° and(4.85±2.46)°,respectively;while in traditional operation group were 20%,(176.73±3.46)°,(3.27±3.46)°,(2.44±0.26)°,(6.60±1.86)°;the difference between two groups were statistically sig-nificant(P<0.05).There were no significant difference in WOMAC index and KSS between two groups at 3 and 6 months after operation(P>0.05).Conclusion RSNA system could reduce defective rate of lower limb force line,FPVA deviation angle and FPFA after TKA,which is more accurate and easy to operate than traditional intramedullary localization surgery while ensuring postoperative efficacy.
10.Research on evaluation and screening indicator for emergency ventilators
Qin-Qi YAO ; Ming-Kang TANG ; Long-Ying YE ; Pei-Pei ZHANG ; Ke-Sheng WANG ; Dan LING ; Qian-Hong HE ; Zhu CHEN
Chinese Medical Equipment Journal 2024;45(7):8-16
Objective To propose an evaluation and screening indicator for the reliability of emergency ventilators.Methods Firstly,a regression model was used to clean the data and remove noise to ensure the accuracy of regression analysis.Then,four groups of highly correlated data combinations,including inspiratory tidal volume-minute expiratory volume,peak airway pressure-minute expiratory volume,peak airway pressure-inspiratory tidal volume and positive end-expiratory pressure(PEEP)-mean airway pressure,were determined with the methods of curve fitting and transfer function,and the difference between the theoretical output and the actual output of the data combinations was regarded as an indicator to judge whether the ventilator functioned well or not;finally,the indicator proposed was applied to single and multiple ventilators,and the feasibility of the indicator was determined by the proportion of the ventilators functioning well.Results The evaluation results with a single ventilator showed the four groups of data combinations had the actual output fitted well with the theoretical output,and all the differences between the theoretical output and the actual output were lower than the threshold;the results with multiple ventilators indicated there were 71.49%ventilators functioning well,which was very close to the actual result that 72%ventilators behaved well.Conclusion The evaluation and screening indicator for emergency ventilators has high feasibility,and theoretical support is provided for reliability assessment and selection of series of emergency treatment equipment.[Chinese Medical Equipment Journal,2024,45(7):8-16]

Result Analysis
Print
Save
E-mail