1.Research progress in therapeutic strategy of human immunodeficiency virus type 1 latenty by targeting Tat
Journal of Jilin University(Medicine Edition) 2025;51(3):831-838
Human immunodeficiency virus type 1(HIV-1)latent reservoirs pose the primary obstacle to curing acquired immunodeficiency syndrome(AIDS).Transactivator(Tat),a regulatory protein encoded by HIV-1,influences the establishment and reactivation of latent reservoirs by promoting viral transcription.Inhibitors targeting Tat protein suppress viral rebound by reducing Tat protein levels and disrupting its transcription-promoting functions.Among the two strategies for treating HIV-1 latent reservoirs,the"block-and-lock"strategy,which is based on Tat protein inhibitors,aims to target HIV-1 proteins or host factors while interfering with histone epigenetic modifications,thereby permanently silencing proviral DNA and maintaining HIV-1 latency even after treatment discontinuation.Tat-related inhibitors such as didehydrocortistatin A(dCA),triptolide,and apalutamide-derived Q308 regulate HIV-1 latency through distinct mechanisms.This review summarizes the regulatory roles of Tat in HIV-1 latency,Tat protein inhibitor-based therapeutic strategies for targeting latent reservoirs,and the mechanisms of action of related inhibitors,with the goal of providing insights for the development of drugs toward achieving functional HIV-1 cure.
2.Development and Reliability and Validity Analysis of Traditional Chinese Medicine Diagnostic Scale for Pulmonary Qi Stagnation Syndrome in Chronic Obstructive Pulmonary Disease
Xiaoqian LIAO ; Xingyu FAN ; Ge FANG ; Yuquan TAN ; Haobo JIANG ; Zhixi HU
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(5):1228-1233
Objective To construct a traditional Chinese medicine diagnostic scale suitable for chronic obstructive pulmonary disease(COPD)with lung qi stagnation syndrome,and to verify the reliability and validity of the scale.Methods Preliminary research has identified 16 core symptom items for lung qi stagnation syndrome.Diagnosis and scale collection were conducted on 95 patients using both traditional Chinese and Western medicine,with scores of 0,1,2,and 3 based on the severity of symptoms.By frequency t-test,discrete trend,and Cronbach's alpha coefficient screening items were used to evaluate the internal consistency of the scale,Spearman Brown coefficient was used to evaluate the stability of the scale,and exploratory factor analysis was used to determine the structural validity of the scale.Results Partial items were excluded and the final 11 scale items were confirmed.The overall Cronbach's alpha coefficient of the scale was 0.719,and the overall Spearman Brown coefficient was 0.647;The KMO test value is 0.612>0.5,The significance level of Bartlett's sphericity test is P<0.01;Extracting common factors with feature roots greater than 1,the maximum total variance explained by 64.122%was achieved when extracting four common factors.The common factor loadings for each item were all greater than 0.5,and the variance was all greater than 0.4,indicating good structural validity of the scale.Conclusion This study constructed and validated a traditional Chinese medicine diagnostic scale for COPD with lung qi stagnation syndrome.The scale has good reliability and validity,providing a reliable tool for clinical diagnosis and treatment.
3.Application of robot-assisted posterolateral approach in complex primary total hip arthroplasty
Pengfei HU ; Chenyi YE ; Xiang ZHAO ; Rongxin HE ; Xianghua WANG ; Xunzi CAI ; Shigui YAN ; Haobo WU ; Lidong WU
Chinese Journal of Surgery 2025;63(9):792-798
Objective:To analyze the short-and medium-term clinical outcomes of Mako robotic-assisted posterior-lateral approach in complex primary total hip arthroplasty (THA).Methods:A retrospective case series analysis was conducted on 29 patients with complex hip conditions who underwent Mako robotic-assisted posterior-lateral approach at Department of Orthopaedics, the Second Affiliated Hospital of Zhejiang University School of Medicine from November 2020 to December 2024. The patient cohort included 14 cases of developmental dysplasia of the hip, 8 cases of ankylosed hip, 3 cases of traumatic hip arthritis, 3 cases of sequelae of purulent hip arthritis, and 1 case of synovial chondromatosis. There were 12 males and 17 females, with an age of (62.3±9.4) years (range:44 to 79 years). Surgical time, intraoperative blood loss, vascular and nerve injury, postoperative infection, and other complications were recorded. Preoperative and postoperative lower limb length discrepancy, combined offset difference (ΔCO), acetabular abduction angle, and acetabular anteversion angle were measured. The Harris hip score was recorded at regular follow-ups. Data comparison was conducted using the paired sample t-test. Results:All patients successfully underwent surgery with the Mako robotic system. The surgical time was (107.6±41.5) minutes (range:50 to 235 minutes), and the intraoperative blood loss was (165.5±147.7) ml (range:50 to 800 ml). All patients were followed up for a duration of (27.3±16.7) months (range:3 to 51 months). The planned intraoperative acetabular cup abduction angle was 40.1°±1.6° (range: 36° to 45°), and the measured postoperative acetabular cup abduction angle was 40.2°±3.5° (range: 33° to 54°), with no significant difference ( t=0.231, P=0.819). The planned intraoperative acetabular cup anteversion angle was 19.1°±3.9° (range: 15° to 25°), and the measured postoperative acetabular cup anteversion angle was 18.5°±3.4° (range: 10° to 26°), with no significant difference ( t=1.792, P=0.084). The difference in length of both lower limbs was (-17.6±15.0) mm (range:-50 to 10 mm) before operation and (-1.5±16.0) mm (range:-33 to 53 mm) after operation ( t=6.282, P<0.01)(positive values indicate that the surgical side is longer than the contralateral side). The ΔCO was (4.1±12.0) mm (range:-18 to 30 mm) before operation and (-2.2±13.3) mm (range:-44 to 17 mm) after operation, with statistically significant difference ( t=2.635, P=0.014). One patient experienced vascular injury with embolism postoperatively, while no other complications were observed in the remaining patients. No loosening, dislocation, or fracture of the prosthesis was noted during the follow-up period. The Harris function score was improved from (47.1±8.3) points(range:15 to 62 points) preoperatively to (73.0±5.5) points(range:57 to 83 points) at the three-month postoperative follow-up ( t=22.630, P<0.01). Conclusion:The use of Mako robotic assistance in complex total hip arthroplasty can enhance the accuracy of prosthesis placement, minimize lower limb length discrepancy, and improve hip joint function.
4.Development and Reliability and Validity Analysis of Traditional Chinese Medicine Diagnostic Scale for Pulmonary Qi Stagnation Syndrome in Chronic Obstructive Pulmonary Disease
Xiaoqian LIAO ; Xingyu FAN ; Ge FANG ; Yuquan TAN ; Haobo JIANG ; Zhixi HU
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(5):1228-1233
Objective To construct a traditional Chinese medicine diagnostic scale suitable for chronic obstructive pulmonary disease(COPD)with lung qi stagnation syndrome,and to verify the reliability and validity of the scale.Methods Preliminary research has identified 16 core symptom items for lung qi stagnation syndrome.Diagnosis and scale collection were conducted on 95 patients using both traditional Chinese and Western medicine,with scores of 0,1,2,and 3 based on the severity of symptoms.By frequency t-test,discrete trend,and Cronbach's alpha coefficient screening items were used to evaluate the internal consistency of the scale,Spearman Brown coefficient was used to evaluate the stability of the scale,and exploratory factor analysis was used to determine the structural validity of the scale.Results Partial items were excluded and the final 11 scale items were confirmed.The overall Cronbach's alpha coefficient of the scale was 0.719,and the overall Spearman Brown coefficient was 0.647;The KMO test value is 0.612>0.5,The significance level of Bartlett's sphericity test is P<0.01;Extracting common factors with feature roots greater than 1,the maximum total variance explained by 64.122%was achieved when extracting four common factors.The common factor loadings for each item were all greater than 0.5,and the variance was all greater than 0.4,indicating good structural validity of the scale.Conclusion This study constructed and validated a traditional Chinese medicine diagnostic scale for COPD with lung qi stagnation syndrome.The scale has good reliability and validity,providing a reliable tool for clinical diagnosis and treatment.
5.Application of robot-assisted posterolateral approach in complex primary total hip arthroplasty
Pengfei HU ; Chenyi YE ; Xiang ZHAO ; Rongxin HE ; Xianghua WANG ; Xunzi CAI ; Shigui YAN ; Haobo WU ; Lidong WU
Chinese Journal of Surgery 2025;63(9):792-798
Objective:To analyze the short-and medium-term clinical outcomes of Mako robotic-assisted posterior-lateral approach in complex primary total hip arthroplasty (THA).Methods:A retrospective case series analysis was conducted on 29 patients with complex hip conditions who underwent Mako robotic-assisted posterior-lateral approach at Department of Orthopaedics, the Second Affiliated Hospital of Zhejiang University School of Medicine from November 2020 to December 2024. The patient cohort included 14 cases of developmental dysplasia of the hip, 8 cases of ankylosed hip, 3 cases of traumatic hip arthritis, 3 cases of sequelae of purulent hip arthritis, and 1 case of synovial chondromatosis. There were 12 males and 17 females, with an age of (62.3±9.4) years (range:44 to 79 years). Surgical time, intraoperative blood loss, vascular and nerve injury, postoperative infection, and other complications were recorded. Preoperative and postoperative lower limb length discrepancy, combined offset difference (ΔCO), acetabular abduction angle, and acetabular anteversion angle were measured. The Harris hip score was recorded at regular follow-ups. Data comparison was conducted using the paired sample t-test. Results:All patients successfully underwent surgery with the Mako robotic system. The surgical time was (107.6±41.5) minutes (range:50 to 235 minutes), and the intraoperative blood loss was (165.5±147.7) ml (range:50 to 800 ml). All patients were followed up for a duration of (27.3±16.7) months (range:3 to 51 months). The planned intraoperative acetabular cup abduction angle was 40.1°±1.6° (range: 36° to 45°), and the measured postoperative acetabular cup abduction angle was 40.2°±3.5° (range: 33° to 54°), with no significant difference ( t=0.231, P=0.819). The planned intraoperative acetabular cup anteversion angle was 19.1°±3.9° (range: 15° to 25°), and the measured postoperative acetabular cup anteversion angle was 18.5°±3.4° (range: 10° to 26°), with no significant difference ( t=1.792, P=0.084). The difference in length of both lower limbs was (-17.6±15.0) mm (range:-50 to 10 mm) before operation and (-1.5±16.0) mm (range:-33 to 53 mm) after operation ( t=6.282, P<0.01)(positive values indicate that the surgical side is longer than the contralateral side). The ΔCO was (4.1±12.0) mm (range:-18 to 30 mm) before operation and (-2.2±13.3) mm (range:-44 to 17 mm) after operation, with statistically significant difference ( t=2.635, P=0.014). One patient experienced vascular injury with embolism postoperatively, while no other complications were observed in the remaining patients. No loosening, dislocation, or fracture of the prosthesis was noted during the follow-up period. The Harris function score was improved from (47.1±8.3) points(range:15 to 62 points) preoperatively to (73.0±5.5) points(range:57 to 83 points) at the three-month postoperative follow-up ( t=22.630, P<0.01). Conclusion:The use of Mako robotic assistance in complex total hip arthroplasty can enhance the accuracy of prosthesis placement, minimize lower limb length discrepancy, and improve hip joint function.
6.3D printed metal augment or tibial prosthesis for reconstruction of large bone defects in total knee arthroplasty and revision surgery
Pengfei HU ; Haobo WU ; Jisheng RAN ; Jiapeng BAO ; Lifeng JIANG ; Weiping CHEN ; Xiang ZHAO ; Shigui YAN ; Lidong WU
Chinese Journal of Orthopaedics 2024;44(4):243-249
Objective:To investigate the clinical efficacy of 3D printed metal augment or tibial prosthesis for reconstruction of large bone defects in total knee arthroplasty (TKA) and knee revision surgery.Methods:A total of 7 patients (7 knees) with TKA or knee revision who were admitted to the Department of Orthopaedics of the Second Affiliated Hospital of Zhejiang University School of Medicine with large bone defects from July 2018 to December 2023 were retrospectively analyzed, including 4 patients with TKA and 3 patients with knee revision. There were 3 males and 4 females, aged 58.7±7.6 years (range, 54-68 years), 3 patients with left knee and 4 patients with right knee. All the patients had bone defects in the knee joint (AORI type III), 2 cases had bone defects only in the femur, 4 cases had bone defects only in the tibia, and 1 case had bone defects in both the tibia and femur, which were treated with personalized reconstruction using 3D printing. Hip-knee-ankle angles, American Knee Society score (KSS) before and after surgery were compared, and postoperative complications were observed.Results:All patients successfully completed the operation, and the operation time was 189.3±35.5 min (range, 125-240 min). Complex TKA was performed in 4 cases with surgical times of 175, 195, 210, and 240 min, and revision surgery was performed in 3 cases with surgical times of 125, 180, and 200 min, respectively. Intraoperative blood loss was 114±24.4 ml (range, 100-150 ml). Five cases used 3D printed metal augment, and two used 3D printed one-piece tibial components. All patients were followed up for 2, 2, 5, 6, 7, 20, 57 months, respectively. The KSS of the five patients at 3 months postoperatively were 56, 61, 66, 56, and 56 points, respectively, greater than the preoperative scores of 35, 44, 36, 27, and 41 points. The KSS functional scores of the five patients at 3 months postoperatively were 45, 45, 45, 30, and 45 points, respectively, which were greater than the preoperative scores of 30, 30, 15, 20, and 20 points. The hip-knee-ankle angle was 181.8°±3.4° (range, 177.9° to 188.0°) at the final follow-up and 175.8°±12.4° (range, 153.3° to 192.1°) before surgery, with no significant difference ( t=-1.230, P=0.242). At the final follow-up, the 3D printed component was well integrated with the bone surface, the prosthesis was securely positioned, and the force lines of the lower limbs were normal. There were no postoperative complications such as poor wound healing, infection, fat liquefaction, nerve injury, deep vein thrombosis of lower limbs, knee joint stiffness, periprosthesis infection and loosening. Conclusion:Using 3D printed metal augment or tibial prosthesis to reconstruct the huge bone defect in TKA and revision has a satisfactory early clinical effect, satisfactory joint function and good surgical safety.
7.Discussion on the staged treatment of chronic heart failure based on the theory of "deficiency, blood stasis, water and toxin"
Kun LIAN ; Shumin HUANG ; Ge FANG ; Haobo JIANG ; Peng LUO ; Zizheng WU ; Zhixi HU
International Journal of Traditional Chinese Medicine 2023;45(11):1350-1355
Deficiency, stasis, water and toxin are of great significance in the pathogenesis and pathologic evolution of chronic heart failure (CHF). Based on "deficiency, blood stasis, water and toxin", the pathogenesis and treatment of CHF were discussed in this article. It was found that in the pathogenesis, deficiency--deficiency of heart qi and deficiency of heart yang were the origin of the disease, and blood stasis, water and toxin were the markers of the disease. Among them, blood stasis was the central pathological link, and also an important mechanism that could aggravate the disease and cause a vicious cycle; water-phlegm and water dampness were the basic pathological products; toxin-heat toxin, water toxin, and stasis toxin were the final results of disease progress and product accumulation. In terms of treatment, CHF can be divided into four stages: early, middle, late and end. In the early stage, tonifying qi and regulating heart can be used for the treatment of root cause, and promoting blood circulation and water can be used for the treatment of symptoms; tonifying qi and yin and reinforcing the healthy qi, reducing blood stasis, purging turbid, and eliminating pathogenic factors can be used in the middle stage; reducing blood stasis and removing toxic materials should be used in the late stage, supplemented with warming yang and increasing urine excretion; astringing yang,generating body fluids, tonifying qi and yang should be used in the end stage. At the same time of treating by stages, attention should be paid to adhering to a holistic concept and dialectical treatment; pay attention to timing and flexible medication; adopting a combination of Chinese and Western approaches and integrating them.
8.Effect of escitalopram combined with repetitive transcranial magnetic stimulation on efficacy and attention function of patients with first-episode unipolar depression
Jianxi HU ; Haobo CHEN ; Huameng HUANG ; Rong HU ; Guihe HU ; Aihua GUO ; Man LI ; Huikun DENG ; Xiaoping PAN
Chinese Journal of Neuromedicine 2023;22(10):1038-1043
Objective:To observe the effect of escitalopram combined with repetitive transcranial magnetic stimulation (rTMS) on efficacy and attention function in patients with first-episode unipolar depression.Methods:Fifty-two first-episode initial-naive unipolar depression patients were enrolled in Department of Neurology of Guangzhou First People's Hospital from March 2022 to April 2023 were chosen. They were randomly allocated to active stimulation group ( n=27) and sham stimulation group ( n=25); both were treated with escitalopram, and active treatment or sham treatment in the left dorsolateral prefrontal cortex (DLPFC) were given for 4 weeks (5 d per week, 20 d totally). Before treatment and 2 and 4 weeks after treatment, Hamilton Depression Rating Scale (HAMD)-24 was used to evaluate depressive symptoms, and Birmingham Cognitive Screening Scale-Chinese (BCoS-C) was used to evaluate the attention function. Results:(1) In terms of depressive symptoms: HAMD-24 scores of the active stimulation group 2 and 4 weeks after treatment (20.63±2.73, 15.85±2.43) were significantly lower than those before treatment (25.74±2.68, P<0.05); HAMD-24 scores of sham stimulation group 4 weeks after treatment were also significantly lower than those before treatment ([20.48±2.33] vs. [25.80±2.57], P<0.05); HAMD-24 scores of the active stimulation group 2 and 4 weeks after treatment were significantly lower than those of sham stimulation group ( P<0.05). (2) In terms of auditory attention indicators: total correct number (selective attention) in active stimulation group 4 weeks after treatment was significantly larger than that before treatment (51.74±1.38 vs. 47.48±1.60), and the sustained index (sustained attention) was significantly lower than that before treatment (0.74±0.71 vs. 4.37±1.15, P<0.05); total correct number in active stimulation group 4 weeks after treatment was significantly larger than that in sham stimulation group (48.00±1.66), and the sustained index was significantly lower than that in sham stimulation group (3.72±1.28, P<0.05). Conclusion:Combined with escitalopram, rTMS can more effectively mitigate the depressive symptoms in first-episode unipolar depression patients, and depressive symptoms improve more quickly than attentional function.
9.The creation and application of entity teaching model of medical physics—taking hemodynamics as example
Haobo KANG ; Lihua QIAO ; Hui TIAN ; Yarui HU ; Jingzhe LI ; Chenru HAO
Chinese Journal of Medical Education Research 2021;20(5):529-532
Hemodynamics is a branch of fluid mechanics, which mainly studies the physiological process of circulatory system from the perspective of mechanics, and has a wide range of applications in medicine. The entity teaching model is made to help medical students master the knowledge of hemodynamics more easily and intuitively by showing them the phenomenon of laminar flow, turbulence and axial concentration of red blood cells. And then we check their learning effect by questionnaires. Students are interested in the entity teaching model that the teacher has used in the class. Thus, the entity teaching model can play an important role in the teaching process.
10. Analysis on the short-term outcome of patients with acute myocardial infarction complicating cardiogenic shock due to left main disease
Chao GUO ; Haobo XU ; Xin DUAN ; Xiaoying HU ; Jun ZHANG ; Jia LI ; Xiaojin GAO ; Xiaoliang LUO ; Weixian YANG ; Fenghuan HU ; Yuan WU ; Shubin QIAO
Chinese Journal of Cardiology 2019;47(4):278-283
Objective:
To investigate the short-term outcome of patients with acute myocardial infarction complicating cardiogenic shock due to left main disease.
Methods:
A total of 24 patients with acute myocardial infarction complicating cardiogenic shock due to left main artery disease hospitalized in Fuwai hospital from June 2012 to May 2018 were included. The clinical data were analyzed,and the patients were divided into survivor group (11 cases) and death group (13 cases) according to survival status at 28 days post the diagnosis of shock. The patients were further divided into thrombolysis in myocardial infarction(TIMI) flow grade 0-2 group (11 cases) and TIMI flow grade 3 group (13 cases) according to TIMI flow grade after the procedure. The patients were then divided into non-three-vessel lesions group (14 cases) and three-vessel lesions group (10 cases) according to coronary angiography results.
Results:
Compared with survivor group, patients in death group presented with lower worst systolic blood pressure within 24 hours after admission (50(48, 70) mmHg (1 mmHg=0.133 kPa) vs. 73(70, 80) mmHg,

Result Analysis
Print
Save
E-mail