1.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
2.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
3.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
4.Overview of the Research on Mechanisms and Application of Essential Oil of Aromatic Chinese Medicinals in Prevention of Respiratory Infectious Disease
Wan Ling LI ; Xinxin WU ; Xiaolei LI ; Mingzhao HAO ; Fang ZHANG ; Yue ZHANG ; Haoyue LI ; Jing ZHAO
Journal of Traditional Chinese Medicine 2025;66(6):638-644
Aromatic Chinese medicinal essential oils are volatile oils extracted from aromatic Chinese herbs, which can prevent and treat respiratory infectious diseases through multiple synergistic mechanisms including pathogen inhibition, immune regulation, and inflammatory response regulation. Essential oils are primarily used externally on the body to prevent infections and alleviate symptoms through methods like inhalation, smearing, topical application, bathing, gargling or as a suppository. They can also be utilized in the environment for disinfection and air purification, through methods like diffusion, vaporization, or spraying. The external application of essential oils extracted from Chinese aromatic herbs has the advantages of convenience, quick absorption, and simultaneous influence on both the body and mind. However, there are still challenges and deficiencies in aspects such as the positioning of functions, indications, safety, and the research on the mechanism of action. It has been proposed to combine the theory of aromatic Chinese medicinals with the characteristics of essential oils, and formulate prescriptions of Chinese medicinal essential oils under the principles of traditional Chinese medicine syndrome differentiation, and prevent and treat respiratory infectious diseases efficiently, accurately, and safely, thereby expanding the clinical application of aromatic Chinese medicinals and the preventive theory of traditional Chinese medicine.
5.Acceptance and commissioning testing of multiparametric imaging using the big bore dual-source CT simulator for radiotherapy
Meijiao WANG ; Yi DU ; Kaining YAO ; Zhongsu FENG ; Jixiang CHEN ; Hao WU ; Kaixuan LI ; Haizhen YUE
Chinese Journal of Radiological Health 2025;34(5):764-769
Objective To evaluate the accuracy of multiparametric imaging on the dual-source CT through acceptance and commissioning testing, and to provide a reference for standardized clinical application. Methods Both the adult and pediatric dual-source CT scanning modes were used to scan the electron density phantom, and identical multiparametric image reconstruction tasks were performed, including the conventional CT images, the mixed CT images, the virtual monoenergetic images, the iodine images, the electron density images, and the effective atomic number images. Results In the adult scanning mode, the virtual monoenergetic CT numbers showed the greatest difference for the cortical bone (
6.Pathophysiological mechanisms linking chronic stress and cervical spondylosis of vertebral artery type: A theoretical framework of the neuroendocrine-immune network.
Kai HU ; Ping DONG ; Hao WU ; Yue WANG ; Ruijie HOU ; Guangyuan YAO
Chinese Journal of Cellular and Molecular Immunology 2025;41(7):655-660
Stress is a critical inducer in the onset and progression of many chronic diseases. Prolonged or intense stress can disrupt the overall balance between the nervous, immune, and endocrine systems. The resulting biological signals may act on corresponding receptors in the cervical spine region, leading to adverse pathological changes. The vertebral artery and the surrounding muscular and connective tissues are influenced by biomechanical abnormalities and inflammatory cascades associated with cervical spondylosis of vertebral artery type (CSA), which promotes the release of various hormones. These hormones, through the neuroendocrine-immune system, affect the central nervous system, inducing or exacerbating negative emotional feedback and thereby establishing a "central-local-central" vicious cycle. This article explores the mechanisms underlying the impact of stress on the key CSA symptoms through the neuroendocrine-immune network (NEI) theory, providing a more comprehensive framework for targeted therapeutic interventions in CSA.
Humans
;
Neurosecretory Systems/immunology*
;
Spondylosis/etiology*
;
Vertebral Artery/immunology*
;
Stress, Psychological/complications*
;
Chronic Disease
7.NAT10 inhibition alleviates astrocyte autophagy by impeding ac4C acetylation of Timp1 mRNA in ischemic stroke.
Li YANG ; Xiaotong LI ; Yaxuan ZHAO ; Hao CHEN ; Can WANG ; Angrong WU ; Xintong GUO ; Yue HUANG ; Qihui WANG ; Lingyun HAO ; Xiaowen LI ; Ying JI ; Jin BAN ; Guangtian WANG ; Junli CAO ; Zhiqiang PAN
Acta Pharmaceutica Sinica B 2025;15(5):2575-2592
Although a single nucleotide polymorphism for N-acetyltransferase 10 (NAT10) has been identified in patients with early-onset stroke, the role of NAT10 in ischemic injury and the related underlying mechanisms remains elusive. Here, we provide evidence that NAT10, the only known RNA N4-acetylcytidine (ac4C) modification "writer", is increased in the damaged cortex of patients with acute ischemic stroke and the peri-infarct cortex of mice subjected to photothrombotic (PT) stroke. Pharmacological inhibition of NAT10 with remodelin on Days 3-7 post-stroke or astrocytic depletion of NAT10 via targeted virus attenuates ischemia-induced infarction and improves functional recovery in PT mice. Mechanistically, NAT10 enhances ac4C acetylation of the inflammatory cytokine tissue inhibitor of metalloproteinase 1 (Timp1) mRNA transcript, which increases TIMP1 expression and results in the accumulation of microtubule-associated protein 1 light chain 3 (LC3) and progression of astrocyte autophagy. These findings demonstrate that NAT10 regulates astrocyte autophagy by targeting Timp1 ac4C after stroke. This study highlights the critical role of ac4C in the regulation of astrocyte autophagy and proposes a promising strategy to improve post-stroke outcomes via NAT10 inhibition.
8.Pitavastatin-loaded procyanidins self-assembled nanoparticles alleviate advanced atherosclerosis via modulating macrophage efferocytosis and cholesterol efflux.
Yizhou WU ; Hongyan ZHOU ; Hao LIU ; Jiayao HU ; Yue SUN ; Wei YAN ; Chunyi TONG ; Ying KONG ; Bin LIU
Acta Pharmaceutica Sinica B 2025;15(6):3305-3320
Advanced atherosclerosis is the major global cause of death, as featured by the aggregation of apoptotic cells (ACs) in necrotic cores. The defective efferocytosis and dysfunctional cholesterol efflux of macrophages are the main reasons for forming necrotic cores in advanced atherosclerosis. In this study, we constructed self-assembled procyanidins (PC) NPs for loading pitavastatin (Pita). The designed HA@PC@Pita NPs with hyaluronic acid (HA) modification combined the advantages of efferocytosis restoration of Pita and cholesterol efflux enhancement of PC. In vitro assay indicated that HA@PC@Pita NPs could induce M1/M2 repolarization and upregulate ERK5/Mertk expression to restore efferocytosis of macrophages. Simultaneously, HA@PC@Pita NPs notably promoted cholesterol efflux by promoting macrophage lipophagy, a selective autophagy of lipid droplets. In vivo study showed that HA@PC@Pita NPs cleared necrotic core and enhanced plaque stability in the ApoE -/- mice model with advanced atherosclerosis. Taken together, this study demonstrated the potential of HA@PC@Pita NPs for the treatment of advanced atherosclerosis.
9.Study on the aging performances of fluoroelastomer FM-1D in hot air
Xiang LIU ; Yi WANG ; Yue WANG ; Hao WU ; Hongchang QIAN ; Pisheng ZHAO
Space Medicine & Medical Engineering 2025;36(3):259-262
To investigate the aging behavior of fluoroelastomer FM-1D in hot air,with compression set as a parameter for seal aging,aging tests were conducted on fluoroelastomer FM-1D under different initial compression rates in a hot air environment ranging from 60℃to 150℃.The aging kinetic equation relating compression set of FM-1D to temperature and time was established,in order to predict its aging life at 25℃.The test results indicated that when the initial compression rate was 30%,the compression set exhibited an Arrhenius relationship with both test temperature and time.However,at a initial compression rate of 50%,the compression set gradually conformed to the Arrhenius relationship as time extended.These findings provide a reference for determining accelerated testing methods and maintenance cycles for FM-1D rubber materials.
10.Influence of pre-radiotherapy ultrasonic monitoring of bladder filling levels on setup errors in cervical cancer patients
Jiangyan LUO ; Haizhen YUE ; Jiacheng LIU ; Yichen PU ; Zihong LU ; Jianqi HU ; Hao WU
Chinese Journal of Radiological Medicine and Protection 2025;45(4):290-295
Objective:To investigate the influence of ultrasonic monitoring of bladder filling levels on setup errors before fractionated radiotherapy for cervical cancer patients through a comparative analysis, and its effectiveness in improving clinical target volume (CTV) margins.Methods:A retrospective study was conducted on 1 284 error data of setup via cone beam CT (CBCT) and 6D setup error correction system from 172 cervical cancer patients treated in the Radiotherapy Department of Peking University Cancer Hospital from January 2019 to October 2023. These patients were classified into two groups: 87 (659 times of setup) with ultrasonic monitoring of bladder filling levels and 85 (625 times of setup) without ultrasonic monitoring. The setup errors, error distributions, and numbers of abnormal setups between the two groups were compared in the lateral (Lat), longitudinal (Lng), vertical (Vrt), pitch (Pitch), roll (Roll), and rotational (Rtn) dimensions. Moreover, the CTV to planning target volume(PTV) margin values in the three-dimensional direction were calculated for both groups to assess the clinical value of ultrasonic monitoring of bladder filling levels before fractionated radiotherapy.Results:Compared to the group without ultrasonic monitoring, the group with ultrasonic monitoring exhibited lower median values of setup errors in all six-dimensional directions and smaller upper and lower interquartile ranges ( Z = -10.86 to -6.34, P<0.05). The group with ultrasonic monitoring manifested more concentrated setup errors in various directions and statistically significantly reduced numbers of abnormal setups ( χ2=15.33, P<0.05). Moreover, CTV-PTV margins of the group with ultrasonic monitoring displayed reduced CTV-PTV margin values by 0.55, 1.52, and 1.26 mm in the Vrt, Lng, and Lat directions, respectively. Conclusions:Pre-radiotherapy ultrasonic monitoring of bladder filling levels in cervical cancer patients can significantly improve the repeatability of setup, thus notably reducing the incidence of abnormal setups. Theoretically, it can narrow the range from the CTV to the PTV, thereby minimizing radiation exposure to healthy tissues and ultimately enhancing radiotherapy precision for cervical cancer and reducing radiation damage.

Result Analysis
Print
Save
E-mail