1.Effects and mechanisms of combined exposure to noise and microwave on hippocampal structure and function in mice
Chunxue LU ; Lei SHI ; Yue WANG ; Yanhui HAO ; Xuelong ZHAO ; Yang LI ; Hongyan ZUO ; Liqian ZHU
Journal of Environmental and Occupational Medicine 2026;43(4):419-426
Background Co-exposure to noise and microwave radiation occurs frequently. The central nervous system has been identified as a sensitive target organ for both noise and microwave exposure individually, and the underlying mechanisms remain poorly understood. The specific biological effects resulting from co-exposure to these two factors have yet to be fully elucidated. Objective To clarify the effects of co-exposure to noise and microwave on neurobehavior and hippocampal tissue structure, and to explore the underlying mechanism through the assessment of serum cytokines. Methods C57BL/6N mice were selected and randomly assigned to a blank control group, a noise group, a microwave group, and a combined noise & microwave exposure group. To establish the exposure models, the noise group was subjected to broadband noise at 100 dB for 2 h, while the microwave group received radiation at a central frequency of 9.375 GHz with an average power density of 12 mW·cm−2 and a specific absorption rate of 2.58 W·kg−1 for 15 min. Open field and tail suspension tests assessed anxiety-like emotional behaviour; novel object recognition and Y-maze tests evaluated cognitive function. Histological changes in hippocampal tissue were examined using haematoxylin and eosin (HE) staining, and Nissl staining under light microscopy. Serum cytokine levels were measured using radioimmunoassay and enzyme-linked immunosorbent assay (ELISA). Results After 3 d of exposure, the noise, microwave, and combined exposure groups showed significant reductions in exploration frequency, duration, and distance within the central zone of the open field test compared to the control group (P < 0.01); the combined exposure group exhibited increased ratios of peripheral-to-central exploration time and distance (P < 0.05). After 7 d of exposure, compared with the control group, the noise group maintained a decrease in central zone exploration time (P < 0.01), while the combined exposure group showed persistent decline across all central zone metrics (P < 0.05) and elevated peripheral-to-central ratios (P < 0.05); compared to the microwave group, the combined exposure group showed significant less time in the central zone (P < 0.05) and higher peripheral-to-central ratios (P < 0.05). Regarding behaviour and cognition, compared with the control group, the combined exposure group showed increased immobility time in the tail suspension test after 3 d of exposure (P < 0.01). At this interval, all exposure groups demonstrated reduced frequency and duration of novel object recognition (P < 0.05), with the combined exposure group showing a marked decrease in novel arm exploration time (P < 0.01). After 7 d of exposure, compared with the control group, the noise group showed reduced novel object recognition frequency (P < 0.05), and both the noise and microwave groups exhibited decreased novel arm exploration time (P < 0.05). Pathological alterations including an increased number of hyperchromatic nuclei and depleted Nissl bodies were observed in the CA3 and DG regions across all exposure groups with the most severe lesions observed in the combined exposure group. Serum levels of central nervous system-specific protein β (S-100β), glial fibrillary acidic protein (GFAP), and corticosterone (CORT) were significantly elevated in all exposure groups compared with the control group (P < 0.05). Aquaporin-4 (AQP4) levels increased in the combined exposure group (P < 0.05), while CXC chemokine ligand 10 (CXCL10) levels rose in both the noise and combined groups compared with the control group (P < 0.05). Specifically, S-100β and CXCL10 levels in the combined exposure group were higher than those in the microwave group (P < 0.05); moreover, levels of S-100β, GFAP, CORT, AQP4, and CXCL10 in the combined exposure group were significantly higher than those in the noise group (P < 0.05). Conclusion Combined exposure to noise and microwave radiation induces pathological changes in the hippocampus of mice, increases levels of serum stress hormones and neuro-specific biomarkers. These impairments are more severe than those observed following single-factor exposure. The underlaying mechanism may be related to systemic stress response, neuronal damage, astrocyte activation, and changes in blood-brain barrier permeability, leading to emotional behavioral abnormalities and cognitive decline.
2.Intra-abdominal Hernia with Bowel Obstruction Triggering Multi-organ Failure: The Role of Preoperative Enteritis
Yue-zhen Wang ; Ben-yi Tian ; Jian-hui Qin ; Hao Liang
Journal of Surgical Academia 2026;16(1):1-4
Intra-abdominal Hernia with Bowel Obstruction Triggering Multi-organ Failure: The Role of Preoperative Enteritis
This report details the clinical course of a 41-year-old male who developed fulminant multiple organ dysfunction syndrome following emergency surgery for a strangulated intra-abdominal hernia. Preoperative manifestations, including diarrhea and marked leukocytosis, pointed towards an underlying infectious enteritis. We posited that surgical release of the obstructed, ischemic bowel segment precipitated a massive systemic influx of endotoxins and inflammatory mediators, triggering septic shock and rapid sequential organ failure. This case underscored the critical need to suspect concomitant gastrointestinal infection in patients presenting with mechanical bowel obstruction accompanied by infectious signs. Aggressive perioperative sepsis management encompassing early empiric antimicrobial therapy, vigilant hemodynamic monitoring, and preparedness for advanced organ support is essential to mitigate this severe complication.
3.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
4.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
5.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
6.Cloning and Functional Characterization of UDP-rhamnose Synthases from Ornithogalum saundersiae
Panpan ZHANG ; Kangxin HOU ; Feng ZHANG ; Yue ZHANG ; Jinlong LIU ; Caixia WANG ; Xuemi HAO
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(23):196-203
ObjectiveTo screen and identify uridine diphosphate (UDP)-rhamnose synthase (RHM) genes from Ornithogalum saundersiae and verify their UDP-rhamnose (UDP-Rha) biosynthetic functions, thereby providing reliable candidate genes for the efficient biosynthesis of neohesperidin and other rhamnoside natural products. MethodsBased on previously reported plant RHM sequences, two candidate RHM genes, OsRHM1 and OsRHM2, were identified from O. saundersiae through transcriptome screening and sequence alignment. The two genes were cloned and subjected to bioinformatics analysis and multiple sequence alignment. An in vitro RHM-Cm1,2RhaT cascade reaction was established, and the ability of OsRHM1 and OsRHM2 to catalyze the conversion of UDP-glucose (UDP-Glc) to UDP-Rha was evaluated based on neohesperidin production. Real-time fluorescence quantitative polymerase chain reaction PCR (Real-time PCR) was performed to analyze the relative expression levels of the two genes in roots, bulbs, and leaves. ResultsThe open reading frame (ORF) of OsRHM1 was 2 076 bp and encoded 692 amino acids, with a predicted protein molecular mass of 77.97 kDa and a theoretical isoelectric point of 7.25. The ORF of OsRHM2 was 2 019 bp and encoded 673 amino acids, with a predicted protein molecular mass of 75.82 kDa and a theoretical isoelectric point of 7.24. Multiple sequence alignment showed that OsRHM1 and OsRHM2 contained the typical conserved motifs GxxGxxG/A and YxxxK of the plant RHM family and shared high amino acid sequence identity with previously reported RHMs. The in vitro cascade reaction demonstrated that both OsRHM1 and OsRHM2 were capable of catalyzing the conversion of UDP-Glc to UDP-Rha. The neohesperidin production in the OsRHM2 cascade reaction system was approximately 2.58-fold that in the OsRHM1 system. Real-time PCR analysis showed that the relative expression levels of OsRHM1 and OsRHM2 were higher in roots than in bulbs and leaves. ConclusionOsRHM2 exhibited a relatively high capacity for UDP-Rha supply and may serve as a candidate enzyme resource for the subsequent biosynthesis of rhamnoside natural products and the construction of UDP-Rha supply systems.
7.Study on the aging performances of fluoroelastomer FM-1D in hot air
Xiang LIU ; Yi WANG ; Yue WANG ; Hao WU ; Hongchang QIAN ; Pisheng ZHAO
Space Medicine & Medical Engineering 2025;36(3):259-262
To investigate the aging behavior of fluoroelastomer FM-1D in hot air,with compression set as a parameter for seal aging,aging tests were conducted on fluoroelastomer FM-1D under different initial compression rates in a hot air environment ranging from 60℃to 150℃.The aging kinetic equation relating compression set of FM-1D to temperature and time was established,in order to predict its aging life at 25℃.The test results indicated that when the initial compression rate was 30%,the compression set exhibited an Arrhenius relationship with both test temperature and time.However,at a initial compression rate of 50%,the compression set gradually conformed to the Arrhenius relationship as time extended.These findings provide a reference for determining accelerated testing methods and maintenance cycles for FM-1D rubber materials.
8.Research progress on activation and blocking of cholinergic anti-inflammatory pathway
Yu-Qi LIU ; Yu-Ru WANG ; Wen-Yue JIA ; Yu-Meng ZHANG ; Yang LIU ; Hui-Qin HAO
Medical Journal of Chinese People's Liberation Army 2025;50(11):1469-1477
The cholinergic anti-inflammatory pathway(CAP)is a neuroimmunoregulatory pathway that has attracted much attention in recent years.This pathway releases acetylcholine(ACh)by activating the vagus nerve.The binding of ACh to α7 nicotinic acetylcholine receptor receptors on the surface of macrophages can inhibit the release of proinflammatory factors,so as to effectively regulate the inflammatory response in the body.CAP plays a key role in suppressing excessive inflammatory responses and maintaining immune balance,providing a potential therapeutic pathway for a variety of inflammatory immune diseases.Research progress on the physiological function of CAP and its activation and blocking methods are reviewed in this paper,in order to provide new methods and ideas for treatment of inflammation-related diseases and exploring therapeutic drugs targeting CAP pathway.
9.Associations of systemic immune-inflammation index and systemic inflammation response index with maternal gestational diabetes mellitus: Evidence from a prospective birth cohort study.
Shuanghua XIE ; Enjie ZHANG ; Shen GAO ; Shaofei SU ; Jianhui LIU ; Yue ZHANG ; Yingyi LUAN ; Kaikun HUANG ; Minhui HU ; Xueran WANG ; Hao XING ; Ruixia LIU ; Wentao YUE ; Chenghong YIN
Chinese Medical Journal 2025;138(6):729-737
BACKGROUND:
The role of inflammation in the development of gestational diabetes mellitus (GDM) has recently become a focus of research. The systemic immune-inflammation index (SII) and systemic inflammation response index (SIRI), novel indices, reflect the body's chronic immune-inflammatory state. This study aimed to investigate the associations between the SII or SIRI and GDM.
METHODS:
A prospective birth cohort study was conducted at Beijing Obstetrics and Gynecology Hospital from February 2018 to December 2020, recruiting participants in their first trimester of pregnancy. Baseline SII and SIRI values were derived from routine clinical blood results, calculated as follows: SII = neutrophil (Neut) count × platelet (PLT) count/lymphocyte (Lymph) count, SIRI = Neut count × monocyte (Mono) count/Lymph count, with participants being grouped by quartiles of their SII or SIRI values. Participants were followed up for GDM with a 75-g, 2-h oral glucose tolerance test (OGTT) at 24-28 weeks of gestation using the glucose thresholds of the International Association of Diabetes and Pregnancy Study Groups (IADPSG). Logistic regression was used to analyze the odds ratios (ORs) (95% confidence intervals [CIs]) for the the associations between SII, SIRI, and the risk of GDM.
RESULTS:
Among the 28,124 women included in the study, the average age was 31.8 ± 3.8 years, and 15.76% (4432/28,124) developed GDM. Higher SII and SIRI quartiles were correlated with increased GDM rates, with rates ranging from 12.26% (862/7031) in the lowest quartile to 20.10% (1413/7031) in the highest quartile for the SII ( Ptrend <0.001) and 11.92-19.31% for the SIRI ( Ptrend <0.001). The ORs (95% CIs) of the second, third, and fourth SII quartiles were 1.09 (0.98-1.21), 1.21 (1.09-1.34), and 1.39 (1.26-1.54), respectively. The SIRI findings paralleled the SII outcomes. For the second through fourth quartiles, the ORs (95% CIs) were 1.24 (1.12-1.38), 1.41 (1.27-1.57), and 1.64 (1.48-1.82), respectively. These associations were maintained in subgroup and sensitivity analyses.
CONCLUSION
The SII and SIRI are potential independent risk factors contributing to the onset of GDM.
Humans
;
Female
;
Pregnancy
;
Diabetes, Gestational/immunology*
;
Prospective Studies
;
Adult
;
Inflammation/immunology*
;
Glucose Tolerance Test
;
Birth Cohort
10.Life's Essential 8 cardiovascular health metrics and long-term risk of cardiovascular disease at different stages: A multi-stage analysis.
Jiangtao LI ; Yulin HUANG ; Zhao YANG ; Yongchen HAO ; Qiuju DENG ; Na YANG ; Lizhen HAN ; Luoxi XIAO ; Haimei WANG ; Yiming HAO ; Yue QI ; Jing LIU
Chinese Medical Journal 2025;138(5):592-594


Result Analysis
Print
Save
E-mail