1.Visualization analysis of studies on Oncomelania hupensis control from 2005 to 2024
Wen ZHU ; Huatang LUO ; Hao WANG ; Yuelin XIONG ; Cong LIU
Chinese Journal of Schistosomiasis Control 2026;38(1):84-91
Objective To analyze Chinese and English publications pertaining to Oncomelania hupensis control from 2005 to 2024, so as to decipher the research status and hotspots of O. hupensis control. Methods Chinese and English publications pertaining to O. hupensis control from 2005 to 2024 were retrieved in the Web of Science Core Collection Database and China National Knowledge Infrastructure. The annual number of publications was analyzed from 2005 to 2024, and the author and institution cooperation networks were mapped using the software CiteSpace 6.3.1. Keywords were extracted from publications to map the co-occurrence, burst and timeline of keywords to identify the research hotspots of O. hupensis control. Results A total of 158 English publications and 771 Chinese publications were included for bibliometric analyses. The overall output of English publications was relatively small from 2005 to 2024, the annual average publication was 7.90 publications. Parasites & Vectors was the most productive journal by the number of publications (21 publications). The three most productive authors included Li Shizhu (24 publications), Zhou Xiaonong (13 publications), and Yang Kun (12 publications), and the three most productive institutions included Chinese Center for Disease Control and Prevention (49 publications), the WHO (27 publications), and Fudan University (25 publications). The annual average number of Chinese publications was high from 2005 to 2015 (57.73 publications), and reduced to 15.11 publications during the period from 2016 to 2024, with Chinese Journal of Schistosomiasis Control as the most productive journal (241 publications). The three most productive authors included Wang Wanxian (18 publications), Sun Qixiang (16 publications), and Dai Jianrong (16 publications), and the three most productive institutions included Jiangsu Institute of Parasitic Diseases (55 publications), Chinese Center for Disease Control and Prevention (47 publications), and Hubei Uni-versity (38 publications). Among the 158 English publications, molluscicidal effect, climate change, geographic information, biological control, machine learning were current research hotspots, and the Yangtze River and elimination were emerging research hotspots. Among the 771 Chinese publications, molluscicidal effect, niclosamide, comprehensive management, molluscicide, effectiveness evaluation, marshland, and endophyte were current research hotspots, and the future research hotspots shifted to molluscicidal effect and pyriclobenzuron. Conclusions Limited attention is paid to the research on O. hupensis control across the world. The Yangtze River, elimination, molluscicidal effect, and pyriclobenzuron may be future research hotspots. High attention is recommended to be paid to the research on O. hupensis control, and development of diverse approaches for O. hupensis control is of urgent needs. We should continue to attach importance to the control research of O. hupensis and strengthen the exploration of diverse snail extermination and control methods.
2.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
3.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
4.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
5.Clinical Diagnosis and Treatment Analysis of Bronchopulmonary Dysplasia in Preterm Infants and Construction of Prognostic Prediction Model
Zhi-jun SONG ; Hao LUO ; Xiao-yun CHU ; Xiao-yue ZHANG ; Bo-wen WENG ; Cheng CAI
Progress in Modern Biomedicine 2025;25(14):2269-2278
Objective:To investigate the clinical management,complications,and prognostic prediction model of bronchopulmonary dysplasia(BPD)in preterm infants.Methods:A total of 854 very preterm infants(gestational age ≤ 32 weeks)admitted to the Neonatal Intensive Care Unit(NICU)of Shanghai Children's Hospital from January 2018 to December 2022 were retrospectively enrolled.After applying inclusion and exclusion criteria,713 infants were included.Based on the 2018 National Institute of Child Health and Human Development(NICHD)diagnostic criteria for BPD,the cohort was divided into a BPD group(n=164)and a non-BPD group(n=549).Clinical data of infants and maternal characteristics were compared between groups.Univariate and stepwise multivariate logistic regression analyses were performed to identify independent risk factors for BPD and evaluate clinical management.A nomogram model was subsequently developed to predict BPD prognosis.Results:Gestational age,duration of non-invasive ventilation,total oxygen therapy time,total hospital stay,hemodynamically significant patent ductus arteriosus(hsPDA),maximum diameter of patent ductus arteriosus(PDA),fetal growth restriction(FGR),use of vasoactive agents,and proportion of pulmonary surfactant administration were identified as independent risk factors for BPD(all P<0.05,OR>0).The nomogram model demonstrated excellent predictive performance,with an area under the receiver operating characteristic curve(AUC)of 0.93 and a calibration curve slope approaching 1.The Hosmer-Lemeshow goodness-of-fit test indicated satisfactory model calibration(x2=8.2865,P=0.406).Conclusion:Gestational age,non-invasive ventilation duration,total oxygen therapy time,total hospital stay,hsPDA,PDA maximum diameter,FGR,vasoactive agents,and pulmonary surfactant use are critical predictors of BPD in preterm infants.The prognostic models for BPD incidence and severity,constructed based on these factors,exhibit strong predictive accuracy and may serve as a valuable clinical tool for risk stratification and early intervention.
6.Clinical Diagnosis and Treatment Analysis of Bronchopulmonary Dysplasia in Preterm Infants and Construction of Prognostic Prediction Model
Zhi-jun SONG ; Hao LUO ; Xiao-yun CHU ; Xiao-yue ZHANG ; Bo-wen WENG ; Cheng CAI
Progress in Modern Biomedicine 2025;25(14):2269-2278
Objective:To investigate the clinical management,complications,and prognostic prediction model of bronchopulmonary dysplasia(BPD)in preterm infants.Methods:A total of 854 very preterm infants(gestational age ≤ 32 weeks)admitted to the Neonatal Intensive Care Unit(NICU)of Shanghai Children's Hospital from January 2018 to December 2022 were retrospectively enrolled.After applying inclusion and exclusion criteria,713 infants were included.Based on the 2018 National Institute of Child Health and Human Development(NICHD)diagnostic criteria for BPD,the cohort was divided into a BPD group(n=164)and a non-BPD group(n=549).Clinical data of infants and maternal characteristics were compared between groups.Univariate and stepwise multivariate logistic regression analyses were performed to identify independent risk factors for BPD and evaluate clinical management.A nomogram model was subsequently developed to predict BPD prognosis.Results:Gestational age,duration of non-invasive ventilation,total oxygen therapy time,total hospital stay,hemodynamically significant patent ductus arteriosus(hsPDA),maximum diameter of patent ductus arteriosus(PDA),fetal growth restriction(FGR),use of vasoactive agents,and proportion of pulmonary surfactant administration were identified as independent risk factors for BPD(all P<0.05,OR>0).The nomogram model demonstrated excellent predictive performance,with an area under the receiver operating characteristic curve(AUC)of 0.93 and a calibration curve slope approaching 1.The Hosmer-Lemeshow goodness-of-fit test indicated satisfactory model calibration(x2=8.2865,P=0.406).Conclusion:Gestational age,non-invasive ventilation duration,total oxygen therapy time,total hospital stay,hsPDA,PDA maximum diameter,FGR,vasoactive agents,and pulmonary surfactant use are critical predictors of BPD in preterm infants.The prognostic models for BPD incidence and severity,constructed based on these factors,exhibit strong predictive accuracy and may serve as a valuable clinical tool for risk stratification and early intervention.
7.Clinical Efficacy of Tangning Tongluo Tablets for Nonproliferative Diabetic Retinopathy
Fuwen ZHANG ; Junguo DUAN ; Wen XIA ; Tiantian SUN ; Yuheng SHI ; Shicui MEI ; Xiangxia LUO ; Xing LI ; Yujie PAN ; Yong DENG ; Chuanlian RAN ; Hao CHEN ; Li PEI ; Shuyu YANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(3):132-139
ObjectiveTo observe the clinical efficacy and safety of Tangning Tongluo tablets in the treatment of nonproliferative diabetic retinopathy (DR). MethodsFourteen research centers participated in this study, which spanned a time interval from September 2021 to May 2023. A total of 240 patients with nonproliferative DR were included and randomly assigned into an observation group (120 cases) and a control group (120 cases). The observation group was treated with Tangning Tongluo tablets, and the control group with calcium dobesilate capsules. Both groups were treated for 24 consecutive weeks. The vision, DR progression rate, retinal microhemangioma, hemorrhage area, exudation area, glycosylated hemoglobin (HbA1c) level, and TCM syndrome score were assessed before and after treatment, and the safety was observed. ResultsThe vision changed in both groups after treatment (P<0.05), and the observation group showed higher best corrected visual acuity (BCVA) than the control group (P<0.05). The DR progression was slow with similar rates in the two groups. The fundus hemorrhage area and exudation area did not change significantly after treatment in both groups, while the observation group outperformed the control group in reducing the fundus hemorrhage area and exudation area. There was no significant difference in the number of microhemangiomas between the two groups before treatment. After treatment, the number of microhemangiomas decreased in both the observation group (Z=-1.437, P<0.05) and the control group (Z=-2.238, P<0.05), and it showed no significant difference between the two groups. As the treatment time prolonged, the number of microhemangiomas gradually decreased in both groups. There was no significant difference in the HbA1c level between the two groups before treatment. After treatment, the decline in the HbA1c level showed no significant difference between the two groups. The TCM syndrome score did not have a statistically significant difference between the two groups before treatment. After treatment, neither the TCM syndrome score nor the response rate had significant difference between the two groups. With the extension of the treatment time, both groups showed amelioration of TCM syndrome compared with the baseline. ConclusionTangning Tongluo tablets are safe and effective in the treatment of nonproliferative DR, being capable of improving vision and reducing hemorrhage and exudation in the fundus.
8.Sleep modes based on objective measurement and diseases of the body systems:a cohort study of 87 617 participants from the UK Biobank dataset
Yimeng WANG ; Qing CHEN ; Siwen LUO ; Fuquan SHI ; Mengchao HE ; Shengfeng WANG ; Qiaorui WEN ; Yingzhong DAI ; Hao QU ; Jia CAO
Journal of Army Medical University 2025;47(4):318-325
Objective To investigate the impact of sleep modes on the risk for diseases of the body systems.Methods Based on a subset of UK Biobank dataset comprising 87 617 participants,3 sleep dimensions including 6 sleep indicators were obtained through a wrist-worn accelerometer,that is sleep duration and onset,sleep rhythm(relative amplitude and stability),and sleep quality(sleep efficiency and number of awakenings).Latent profile analysis(LPA)was applied to identify and classify distinct sleep modes.Then their longitudinal medical records were the association between different sleep modes and the risk for 467 diseases.Results LPA identified 5 subgroups of unique sleep modes in the participants.Among the 5 subgroups,the subgroup 4 had relatively optimal levels in above sleep indicators.Compared to the subgroup 4,the other 4 subgroups exhibited variations in different sleep dimensions,with at least one indicator demonstrating an unfavorable trend.These subgroups also revealed differences in racial composition,shift work and social deprivation index.Moreover,there were notable differences in the risk of various system diseases among the subgroups(P<0.05).When compared to the subgroup 4,the other 4 subgroups exhibited an elevated risk for certain diseases(comprising a total of 126 diseases),with the diseases of the circulatory system,digestive system and musculoskeletal system most common.Among the 5 subgroups,the subgroup 2(shorter sleep duration and later sleep onset)and the subgroup 5(rhythm disorder)had the highest counts of associated risks,amounting to 85 and 91 types,respectively,but there was certain difference in their systematic composition.Conclusion There are different sleep modes within the participants,and the modes are potentially associated with an increased risk for diseases of body systems.Comprehensive interventions targeting overall sleep modes rather than single sleep indicator may yield obvious health benefits.
9.Effectiveness of the integrated schistosomiasis control programme in Wuhan City from 2005 to 2023
Shuai WANG ; Huatang LUO ; Yang LI ; Hao WANG ; Cong LIU ; Yuelin XIONG ; Jiajing ZHANG ; Wen ZHU
Chinese Journal of Schistosomiasis Control 2025;37(2):176-183
Objective To evaluate the effectiveness of the integrated schistosomiasis control programme in Wuhan City from 2005 to 2023, so as to provide insights into precision control and elimination of schistosomiasis. Methods The integrated measures for schistosomiasis control implemented by health, agriculture, water resources, and forestry departments of Wuhan City, and the epidemiological data of schistosomiasis in Wuhan City were collected from 2005 to 2023, and the prevalence of human schistosomiasis, prevalence of Schistosoma japonicum infections in humans and bovines, areas of S. japonicum-infected snail habitats, areas of snail habitats in inner embankments, and actual areas of snail habitats were retrieved. In addition, the trends in prevalence of schistosomiasis in humans and livestock and snail status were evaluated in Wuhan City from 2005 to 2023 using Mann-Kendall test and a Joinpoint regression model. Results Mann-Kendall test revealed a tendency towards a decline in the prevalence of human schistosomiasis (Z = -4.41, P < 0.01), prevalence of S. japonicum infections in humans (Z = -4.89, P < 0.01) and bovines (Z = -4.50, P < 0.01), areas of S. japonicum-infected snail habitats (Z = -3.91, P < 0.01), areas of snail habitats in inner embankments (Z = -2.28, P = 0.02), and actual areas of snail habitats (Z = -5.95, P < 0.01) in Wuhan City from 2005 to 2023. Joinpoint regression analysis showed an average annual reduction of 8.58% in the prevalence of human schistosomiasis in Wuhan City from 2005 to 2023 [average annual percent change (AAPC) = -8.58%, 95% confidence interval (CI): (-10.02%, -6.65%), P < 0.01], with two joinpoints in 2013 and 2016, respectively, and the tendency towards a decline showed statistical significance during the period from 2013 through 2016 [annual percent change (APC) = -34.41%, 95% CI: (-40.36%, -20.01%), P < 0.01]. The prevalence of S. japonicum human infections appeared an average annual reduction of 51.91% in Wuhan City from 2005 to 2023 [AAPC = -51.91%, 95% CI: (-58.12%, -44.25%), P < 0.01], with two joinpoints in 2014 and 2017, respectively, and the tendency towards a decline showed statistical significance during the period from 2014 through 2017 [APC = -98.17%, 95% CI: (-99.17%, -90.87%), P < 0.01]. The prevalence of S. japonicum infections in bovines appeared an average annual reduction of 53.12% in Wuhan City from 2005 to 2023 [AAPC = -53.12%, 95% CI: (-59.65%, -42.44%), P < 0.01], with two joinpoints in 2011 and 2014, respectively, and the tendency towards a decline showed statistical significance during the period from 2014 through 2017 [APC = -98.63%, 95% CI: (-99.44%, -90.93%), P < 0.01]. The areas of S. japonicum-infected snail habitats appeared an average annual reduction of 47.09% in Wuhan City from 2005 to 2023 [AAPC = -47.09%, 95% CI: (-52.92%, -38.26%), P < 0.01], with two joinpoints in 2011 and 2014, respectively, and the tendency towards a decline showed statistical significance during the period from 2011 through 2014 [APC = -97.27%, 95% CI: (-98.65%, -88.06%), P < 0.01]. The areas of snail habitats in inner embankments appeared an average annual reduction of 4.45% in Wuhan City from 2005 to 2023 [AAPC = -4.45%, 95% CI: (-5.18%, -3.82%), P < 0.01], with three joinpoints in 2011, 2015 and 2018, respectively, and statistical significance was seen in the tendency towards a decline during the period from 2005 through 2011 [APC = -16.38%, 95% CI: (-20.15%, -14.25%), P < 0.01]. In addition, the actual areas of snail habitats appeared an average annual reduction of 2.65% in Wuhan City from 2005 to 2023 [AAPC = -2.65%, 95% CI: (-2.89%, -2.40%), P < 0.01], with a joinpoint in 2013, and the tendency towards a decline showed statistical significance during the period from 2013 through 2023 [APC = -4.06%, 95% CI: (-4.66%, -3.58%), P < 0.01]. Conclusions The integrated schistosomiasis control programme achieved significant effectiveness in Wuhan City from 2005 to 2023, with a tendency towards a decline in morbidity due to schistosomiasis in humans and livestock and snail status. The integrated schistosomiasis control strategy with emphasis on management of the source of S. japonicum infections should continue to be implemented to consolidate the schistosomiasis control achievements and achieve the goal of schistosomiasis elimination in the city.
10.Sirtuin 3 Attenuates Acute Lung Injury by Decreasing Ferroptosis and Inflammation through Inhibiting Aerobic Glycolysis.
Ke Wei QIN ; Qing Qing JI ; Wei Jun LUO ; Wen Qian LI ; Bing Bing HAO ; Hai Yan ZHENG ; Chao Feng HAN ; Jian LOU ; Li Ming ZHAO ; Xing Ying HE
Biomedical and Environmental Sciences 2025;38(9):1161-1167

Result Analysis
Print
Save
E-mail