1.Clinical analysis of 6 cases of diffuse panbronchiolitis in children.
Li-Xin DENG ; De-Hui CHEN ; Yu-Neng LIN ; Shang-Zhi WU ; Jia-Xing XU ; Zhan-Hang HUANG ; Ying-Ying GU ; Jun-Xiang FENG
Chinese Journal of Contemporary Pediatrics 2025;27(3):334-339
OBJECTIVES:
To analyze the clinical characteristics of diffuse panbronchiolitis (DPB) in children and to enhance the clinical diagnosis and treatment of this disease.
METHODS:
A retrospective analysis was conducted on the clinical data of 6 children diagnosed with DPB who were hospitalized at The First Affiliated Hospital of Guangzhou Medical University from January 2011 to December 2019.
RESULTS:
Among the 6 patients, there were 2 males and 4 females; the age at diagnosis ranged from 7 to 12 years. All patients presented with cough, sputum production, and exertional dyspnea, and all had a history of sinusitis. Two cases showed positive serum cold agglutinin tests, and 5 cases exhibited pathological changes consistent with chronic bronchiolitis. High-resolution chest CT in all patients revealed centrilobular nodules diffusely distributed throughout both lungs with a tree-in-bud appearance. Five patients received low-dose azithromycin maintenance therapy, but 3 showed inadequate treatment response. After empirical anti-tuberculosis treatment, non-tuberculous Mycobacteria were found in the bronchoalveolar lavage fluid. Follow-up over 2 years showed 1 case cured, 3 cases significantly improved, and 2 cases partially improved.
CONCLUSIONS
The clinical presentation of DPB is non-specific and can easily lead to misdiagnosis. In cases where DPB is clinically diagnosed but does not show improvement with low-dose azithromycin treatment, special infections should be considered.
Humans
;
Male
;
Female
;
Bronchiolitis/drug therapy*
;
Retrospective Studies
;
Child
;
Haemophilus Infections/diagnosis*
2.Design and Implementation of Non-Invasive Hemodynamic Monitoring System Based on Impedance Cardiogram Method.
Fuhao KANG ; Qi YIN ; Yanan LIU ; Lin HUANG ; Yan HANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(1):80-88
Hemodynamic monitoring can reflect cardiac function and blood perfusion and is an indispensable monitoring method in clinical practice. Invasive hemodynamic monitoring methods represented by the thermodilution method are limited in their clinical application scope because they require vascular cannulation. Non-invasive hemodynamic monitoring has attracted extensive attention from medical companies and clinicians at home and abroad in recent years due to its advantages such as safety, non-invasiveness, continuous monitoring, simple operation, and low cost. This paper designs a non-invasive hemodynamic monitoring system based on the impedance cardiography, including hardware, algorithm, software design, and performance parameter evaluation. Among them, the hardware part mainly includes a differential high-frequency constant current source stimulation circuit, impedance cardiogram signal acquisition, and ECG signal acquisition circuit. Signal processing includes wave filtering, impedance cardiogram signal calibration, and ECG signal and impedance cardiogram signal feature point recognition. According to the collected impedance cardiogram and ECG signals, hemodynamic parameters such as heart rate (HR), stroke volume (SV), cardiac output (CO), stroke index (SI), cardiac index (CI), and cardiac contractility index (ICON) are calculated based on the Nyboer thoracic cylinder model. After testing, the key technical indicators of the system hardware are better than that of the relevant medical device standards. The system was used to collect impedance cardiogram and ECG signal data from 40 volunteers. The calculated HR, SV, and CO, three important hemodynamic indicators, were compared with the ICONCore non-invasive cardiac output monitor of OSYPKA Medical in Germany. Their Pearson correlation coefficients were 0.992 ( P<0.001), 0.948 ( P<0.001), and 0.933 ( P<0.001), respectively, verifying that the designed system has high accuracy and reliability.
Cardiography, Impedance/methods*
;
Humans
;
Hemodynamic Monitoring/methods*
;
Equipment Design
;
Signal Processing, Computer-Assisted
;
Hemodynamics
;
Algorithms
;
Monitoring, Physiologic/methods*
;
Electrocardiography
3.Development of a Multimodal Transcranial Electrical Stimulation System with Integrated Four-Channel EEG Recordings.
Yan HANG ; Chaoyang WANG ; Qi YIN ; Yanan LIU ; Lin HUANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(3):313-322
In order to improve the effect of transcranial electrical stimulation treatment and realize personalized treatment for patients with varying severity levels, this paper designed an integrated four-channel EEG recording multimodal transcranial electrical stimulation system. This system can conduct real-time monitoring on EEG and related characteristic analysis before stimulation, in stimulation, and after stimulation. This enables physicians and researchers to resolve real-time brain states, evaluate transcranial electrical stimulation effect, and then artificially adjust the stimulation parameters. After relevant testing and verification, the system can select four stimulation modes: TACS, TDCS, TPCS and TRNS, which can output the constant stimulation current of 0.03 mA accuracy in the range of ±2 mA and the stimulation frequency of low frequency of 0~4 kHz (precision of 0.01 Hz) and high frequency 50~100 kHz, which can obtain more accurate EEG signals under stimulation interference, demonstrating a good market application prospect.
Electroencephalography/methods*
;
Transcranial Direct Current Stimulation/instrumentation*
;
Humans
;
Equipment Design
4.Sixteen-Channel Multimodal High-Precision Transcranial Electrical Stimulation System Development.
Yan HANG ; Qi YIN ; Lin HUANG ; Fuhao KANG ; Yanan LIU ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(4):435-443
This paper introduces a 16-channel multimodal high-precision transcranial electrical stimulation system specifically for non-invasive brain stimulation. This system added TMCS mixed four traditional stimulation modes with TACS, TDCS, TPCS and TRNS. By designing a compensated high-precision constant current source, the constant stimulation current with an accuracy of 0.03 mA in the range of ±2 mA and the stimulation frequency of 50~200 kHz with low frequency of 0~4 kHz (high frequency of 0.1 Hz) are realized. In TACS stimulation mode, there are five adjustable wave forms: triangular wave, sine wave, sawtooth wave, square wave and mixed wave. The system has dual closed-loop control overcurrent detection and simultaneous real-time electrode contact impedance detection. After relevant tests and verification, the system has good stimulation accuracy, high safety and reliability. Compared with the existing products at home and abroad, it features lower cost, richer stimulation mode and waveforms, demonstrating a certain market application value.
Transcranial Direct Current Stimulation/instrumentation*
;
Equipment Design
;
Humans
6.Summary of the best evidence on nebulizing inhalation care in adults with mechanical ventilation
Juan DING ; Xiaoli CHEN ; Yue XIAO ; Lin CHEN ; Yingting XU ; Changju LIAO ; Hang SONG ; Xiaoyan ZHANG ; Hong YU
Chinese Journal of Nursing 2024;59(12):1512-1519
Objective The researchers systematically retrieved,evaluated,and summarized the best evidence for the care of nebulized inhalation in adult patients on mechanical ventilation,to provide a basis for standardizing the care of nebulized inhalation in patients on mechanical ventilation.Methods We systematically searched the domestic and foreign databases to collect the evidence on the literature related to nebulization therapy for mechanical ventilation in adults.The time for the retrieval is from the inception of databases until February 2023.There were 3 researchers who evaluated the quality of the literature,and extracted and summarized the evidence based on this subject.Results A total of 19 articles were obtained in database.42 pieces of evidence were summarized,covering pre-assessment of nebulized inhalation,preparation before nebulized inhalation,medication management,selection and standardized use of nebulization devices,respiratory machine mode and parameter settings,equipment management during nebulized inhalation,evaluation of effect,management of adverse reactions,disposal of materials and environment after nebulized inhalation and management of nebulized inhalation for respiratory infectious diseases.Conclusion This study summarized the best evidence for nebulized inhalation nursing in adult patients with mechanical ventilation,so as to provide a reference of standardized nebulized inhalation therapy for such patients,which is conducive to ensuring the safety of patients.
7.Clinical features of hereditary leiomyomatosis and renal cell carcinoma syndrome-associated renal cell carcinoma: a multi-center real-world retrospective study
Yunze XU ; Wen KONG ; Ming CAO ; Guangxi SUN ; Jinge ZHAO ; Songyang LIU ; Zhiling ZHANG ; Liru HE ; Xiaoqun YANG ; Haizhou ZHANG ; Lieyu XU ; Yanfei YU ; Hang WANG ; Honggang QI ; Tianyuan XU ; Bo YANG ; Yichu YUAN ; Dongning CHEN ; Dengqiang LIN ; Fangjian ZHOU ; Qiang WEI ; Wei XUE ; Xin MA ; Pei DONG ; Hao ZENG ; Jin ZHANG
Chinese Journal of Urology 2024;45(3):161-167
Objective:To investigate the clinical features and therapeutic efficacy of patients with hereditary leiomyomatosis and renal cell carcinoma(RCC) syndrome-associated RCC (HLRCC-RCC) in China.Methods:The clinical data of 119 HLRCC-RCC patients with fumarate hydratase (FH) germline mutation confirmed by genetic diagnosis from 15 medical centers nationwide from January 2008 to December 2021 were retrospectively analyzed. Among them, 73 were male and 46 were female. The median age was 38(13, 74) years. The median tumor diameter was 6.5 (1.0, 20.5) cm. There were 38 cases (31.9%) in stage Ⅰ-Ⅱand 81 cases (68.1%) in stage Ⅲ-Ⅳ. In this group, only 11 of 119 HLRCC-RCC patients presented with skin smooth muscle tumors, and 44 of 46 female HLRCC-RCC patients had a history of uterine fibroids. The pathological characteristics, treatment methods, prognosis and survival of the patients were summarized.Results:A total of 86 patients underwent surgical treatment, including 70 cases of radical nephrectomy, 5 cases of partial nephrectomy, and 11 cases of reductive nephrectomy. The other 33 patients with newly diagnosed metastasis underwent renal puncture biopsy. The results of genetic testing showed that 94 patients had FH gene point mutation, 18 had FH gene insertion/deletion mutation, 4 had FH gene splicing mutation, 2 had FH gene large fragment deletion and 1 had FH gene copy number mutation. Immunohistochemical staining showed strong 2-succinocysteine (2-SC) positive and FH negative in 113 patients. A total of 102 patients received systematic treatment, including 44 newly diagnosed patients with metastasis and 58 patients with postoperative metastasis. Among them, 33 patients were treated with tyrosine kinase inhibitor (TKI) combined with immune checkpoint inhibitor (ICI), 8 patients were treated with bevacizumab combined with erlotinib, and 61 patients were treated with TKI monotherapy. Survival analysis showed that the median progression-free survival (PFS) of TKI combined with ICI was 18 (5, 38) months, and the median overall survival (OS) was not reached. The median PFS and OS were 12 (5, 14) months and 30 (10, 32) months in the bevacizumab combined with erlotinib treatment group, respectively. The median PFS and OS were 10 (3, 64) months and 44 (10, 74) months in the TKI monotherapy group, respectively. PFS ( P=0.009) and OS ( P=0.006) in TKI combined with ICI group were better than those in bevacizumab combined with erlotinib group. The median PFS ( P=0.003) and median OS ( P=0.028) in TKI combined with ICI group were better than those in TKI monotherapy group. Conclusions:HLRCC-RCC is rare but has a high degree of malignancy, poor prognosis and familial genetic characteristics. Immunohistochemical staining with strong positive 2-SC and negative FH can provide an important basis for clinical diagnosis. Genetic detection of FH gene germ line mutation can confirm the diagnosis. The preliminary study results confirmed that TKI combined with ICI had a good clinical effect, but it needs to be confirmed by the results of a large sample multi-center randomized controlled clinical study.
8.Correlation between the level of NT-proBNP and cardiorespiratory fitness of individuals following acute high altitude exposure
Ping-Ping LI ; Xiao-Wei YE ; Jie YANG ; Zhe-Xue QIN ; Shi-Zhu BIAN ; Ji-Hang ZHANG ; Xu-Bin GAO ; Meng-Jia SUN ; Zhen LIU ; Hai-Lin LYU ; Qian-Yu JIA ; Yuan-Qi YANG ; Bing-Jie YANG ; Lan HUANG
Medical Journal of Chinese People's Liberation Army 2024;49(9):998-1003
Objective To investigate the correlation between the level of N-terminal pro-Brain natriuretic peptide(NT-proBNP)and cardiorespiratory fitness following acute exposure to high altitude.Methods Forty-six subjects were recruited from the Second Affiliated Hospital of Army Medical University in June 2022,including 19 males and 27 females.After completing cardiopulmonary exercise test(CPET),serological detection of myocardial cell-related markers,and multiple metabolites at a plain altitude(300 meters above sea level),all subjects flew to a high-altitude location(3900 meters above sea level).Biomarker testing and CPET were repeated on the second and third days after arrival at high altitude.Changes in serum biomarker and key CPET indicators before and after rapid ascent to high altitude were compared,and the correlation between serum levels of various myocardial cell-related markers and metabolites and high altitude cardiorespiratory fitness was analyzed.Results Compared with the plain altitude,there was a significant decrease in maximal oxygen uptake after rapid ascent to high altitude[(25.41±6.20)ml/(kg.min)vs.(30.17±5.01)ml/(kg.min),P<0.001].Serum levels of NT-proBNP,Epinephrine(E),plasma renin activity(PRA),angiotensin Ⅱ(Ang Ⅱ),angiotensin-converting enzyme 2(ACE2)and leptin(LEP)significantly increased,with all differences being statistically significant(P<0.05)after acute high altitude exposure.In contrast,no statistically significant differences were observed for creatine kinase MB(CK-MB),cardiac troponin I(cTnI),myoglobin(Myo)and norepinephrine(NE)(P>0.05).Correlation analysis showed a significant negative correlation between NT-proBNP at plain altitude(r=-0.768,P<0.001)and at high altitude(r=-0.791,P<0.001)with maximal oxygen uptake at high altitude.Multivariate linear regression analysis indicated that maximal oxygen uptake at plain altitude(t=2.069,P=0.045),NT-proBNP at plain altitude(t=-2.436,P=0.020)and at high altitude(t=-3.578,P=0.001)were independent influencing factors of cardiorespiratory fitness at high altitude.Conclusion Cardiorespiratory fitness significantly decreases after rapid ascent to high altitude,and the baseline NT-proBNP level at plain altitude is closely related to cardiorespiratory fitness at high altitude,making it a potential predictor indicator for high altitude cardiorespiratory fitness.
9.Research Progress on End-Tidal Carbon Dioxide Detection Technology Based on Non-Dispersive Infrared Method
Yanan LIU ; Mingyue LI ; Fuhao KANG ; Lin HUANG ; Yan HANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2024;48(2):203-207
The concentration of end-tidal carbon dioxide is one of the important indicators for evaluating whether the human respiratory system is normal.Accurately detecting of end-tidal carbon dioxide is of great significance in clinical practice.With the continuous promotion of the localization of end-tidal carbon dioxide monitoring technology,its application in clinical practice in China has become increasingly widespread in recent years.The study is based on the non-dispersive infrared method and comprehensively elaborates on the detection principle,gas sampling methods,key technologies,and technological progress of end-tidal carbon dioxide detection technology.It comprehensively introduces the current development status of this technology and provides reference for application promotion and further improvement.
10.Wireless Pulse Wave Monitoring System Based on Reflective Flexible Probe and AFE4490
Yan HANG ; Lin HUANG ; Yanan LIU ; Haijun WEI ; Jilun YE ; Xu ZHANG ; Chunsheng LIU ; Fan WANG
Chinese Journal of Medical Instrumentation 2024;48(3):330-334
Pulse rate and blood oxygen levels are crucial physiological parameters that reflect physiological and pathological information within the human body.The system designs a wireless pulse wave monitoring system utilizing a flexible reflective probe and the AFE4490,which is capable of monitoring pulse wave and blood oxygen levels on the human forehead.The system is predominantly based on a reflective flexible probe,the AFE4490,a power supply module,a control microcontroller unit(MCU),and a Wi-Fi module.Post-processing by a slave computer,the collected pulse wave data is wirelessly transmitted to a smartphone.The real-time pulse waveform,pulse rate,and blood oxygen levels are displayed on an application.Following relevant tests and verifications,the system can accurately detect pulse wave signals,meet the requirements for wearable technology,and possesses significant market application potential.

Result Analysis
Print
Save
E-mail