1.Environmental contamination status of norovirus outbreaks in schools and nurseries in Linhai City
ZHENG Jianjun, WANG Xi,HONG Danyang, LI Yaling, XU Qiumeng, ZHANG Huili, HAN Qian, LU Da, ZHENG Qiao
Chinese Journal of School Health 2025;46(4):601-603
Objective:
To investigate the environmental contamination of norovirus in nurseries and primary/secondary schools, so as to provide a scientific basis for effective prevention and control measures.
Methods:
A total of 483 external environmental samples were collected from 34 cluster outbreaks of norovirus gastroenteritis in kindergartens and primary/secondary schools in Linhai City from 2021 to 2024. Pathogen detection was conducted using a rapid nucleic acid extraction kit and realtime fluorescence RT-PCR, and the results were analyzed using the χ2 test or Fishers exact test.
Results:
Among the collected external environmental samples, the total positive rate of surface contamination was 13.66%. The positive rates in kindergartens and primary/secondary schools were 12.20% and 15.82%, respectively. In kindergartens, the five surfaces with the highest detection rates were desks/chairs (23.33%), toilet stool troughs (20.69%), urinal troughs (12.00%), washbasins/sinks (11.11%), and toilet mops (9.38%). In primary/secondary schools, the top five were toilet stool troughs (38.30%), urinal troughs (23.53%), toilet door handles (13.04%), toilet mops (12.50%), and drinking cups (11.11%). The difference in positive detection rates among different external environments in primary/secondary schools was statistically significant (Fishers exact probability test, P<0.01). The positive detection rate in sanitary toilets was higher than that in classroom environments (χ2=17.38), while the positive detection rate in classroom environments of kindergartens was higher than that in primary/secondary schools (χ2=5.42)(P<0.05).
Conclusions
Norovirus exhibits a high contamination rate in nurseries and schools, particularly in restroom areas. Strengthening sanitation and disinfection in highrisk environments, and improving hygiene awareness among children and staff, are essential for the effective prevent and control of norovirus.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.A machine learning model for diagnosing acute pulmonary embolism and comparison with Wells score, revised Geneva score, and Years algorithm
Linfeng XI ; Han KANG ; Mei DENG ; Wenqing XU ; Feiya XU ; Qian GAO ; Wanmu XIE ; Rongguo ZHANG ; Min LIU ; Zhenguo ZHAI ; Chen WANG
Chinese Medical Journal 2024;137(6):676-682
Background::Acute pulmonary embolism (APE) is a fatal cardiovascular disease, yet missed diagnosis and misdiagnosis often occur due to non-specific symptoms and signs. A simple, objective technique will help clinicians make a quick and precise diagnosis. In population studies, machine learning (ML) plays a critical role in characterizing cardiovascular risks, predicting outcomes, and identifying biomarkers. This work sought to develop an ML model for helping APE diagnosis and compare it against current clinical probability assessment models.Methods::This is a single-center retrospective study. Patients with suspected APE were continuously enrolled and randomly divided into two groups including training and testing sets. A total of 8 ML models, including random forest (RF), Na?ve Bayes, decision tree, K-nearest neighbors, logistic regression, multi-layer perceptron, support vector machine, and gradient boosting decision tree were developed based on the training set to diagnose APE. Thereafter, the model with the best diagnostic performance was selected and evaluated against the current clinical assessment strategies, including the Wells score, revised Geneva score, and Years algorithm. Eventually, the ML model was internally validated to assess the diagnostic performance using receiver operating characteristic (ROC) analysis.Results::The ML models were constructed using eight clinical features, including D-dimer, cardiac troponin T (cTNT), arterial oxygen saturation, heart rate, chest pain, lower limb pain, hemoptysis, and chronic heart failure. Among eight ML models, the RF model achieved the best performance with the highest area under the curve (AUC) (AUC = 0.774). Compared to the current clinical assessment strategies, the RF model outperformed the Wells score ( P = 0.030) and was not inferior to any other clinical probability assessment strategy. The AUC of the RF model for diagnosing APE onset in internal validation set was 0.726. Conclusions::Based on RF algorithm, a novel prediction model was finally constructed for APE diagnosis. When compared to the current clinical assessment strategies, the RF model achieved better diagnostic efficacy and accuracy. Therefore, the ML algorithm can be a useful tool in assisting with the diagnosis of APE.
8.Research progress on extracellular vesicles in knee osteoarthritis
Xi XIE ; Ye SHI ; Han-Qing DENG ; Xu-Xia YANG ; Xu-Fang TAN ; Hong-Jun LOU ; Ling LI ; Xi GAO
Chinese Pharmacological Bulletin 2024;40(6):1020-1024
The incidence of knee osteoarthritis(KOA)is in-creasing year by year,seriously affecting patients'health.Mes-enchymal stem cells are multipotent cells with multiple differen-tiation functions.The extracellular vesicles released by these cells can carry various"cargo"to corresponding cells and tis-sues,exerting biological functions.They have shown great clini-cal potential in the treatment of KOA.This study reviews the therapeutic effects and mechanisms of extracellular vesicles se-creted by mesenchymal stem cells from different tissues such as bone marrow,adipose tissue,and synovium in KOA.It is found that miRNA is an important biological component in exerting therapeutic effects.The study also discusses the research pro-gress of engineered extracellular vesicles in KOA,pointing out the current challenges in clinical application,such as standard-ized acquisition of extracellular vesicles and difficulties in targe-ted action,aiming to provide a certain reference for the basic re-search and clinical application of extracellular vesicle therapy for KOA.
9.A randomized controlled study of oral-nasal oxygen supply mouth guard in painless gastroscopy for snoring patients
Yanli NI ; Cheng ZHANG ; Weiying ZHANG ; Xiuzhen GAO ; Yongmei YOU ; Lijun HAN ; Lili MA ; Li SHEN ; Yinghua ZHU ; Xi TAN ; Yulong YANG ; Meidong XU
Chinese Journal of Digestive Endoscopy 2024;41(9):718-722
Objective:To evaluate the effectiveness of oral-nasal oxygen supply mouth guard in painless gastroscopy for snoring patients.Methods:The snoring patients who underwent painless gastroscopy at two Endoscopy Centers of Shanghai East Hospital, Tongji University in July 2022 were randomly divided into the observation group (using oral-nasal oxygen supply mouth guard) and the control group (using ordinary nasal oxygen tube and mouth guard). Parameters such as the wearing time and the removal time of the mouth guard, lowest pulse oxygen saturation (SpO 2), incidence of hypoxemia, and the satisfaction of medical staff were compared between the two groups. Results:The wearing time of mouth guard was 11.63±0.84 seconds and the removal time was 5.33±0.76 seconds in the observation group ( n=40), which were lower than those in the control group ( n=47) (14.91±1.21 seconds, t=-14.463, P<0.001; 10.38±0.80 seconds, t=-30.095, P<0.001). The wearing satisfaction score was 9.80±0.61, the lowest SpO 2 was (96.70±3.42)%, the removal satisfaction score was 9.75±0.67, and the anesthesiologists' satisfaction score was 9.20±1.42 in the observation group, which were higher than those in the control group [7.70±0.93, t=12.209, P<0.001; (94.06±3.72)%, t=3.417, P=0.001; 7.96±0.98, t=9.803, P<0.001; 8.13±1.35, t=3.615, P=0.001] with significant difference. There was no significant difference in the incidence of hypoxemia [10.00% (4/40) VS 14.89% (7/47), χ2=0.130, P=0.718] and endoscopic physician satisfaction score (9.30±0.97 VS 9.02±1.31, t=1.112, P=0.269) between the two groups. Conclusion:The oral-nasal oxygen supply mouth guard is easy to wear and remove, effectively reducing SpO 2 fluctuations during painless gastroscopy for snoring patients. It can enhance medical staff satisfaction with high clinical value.
10.Blocking performance test method of disposable check valves for infusion equipment
Xi-Yun DANG ; Su-Hua XU ; Xue BAI ; Jun KE ; Zhi TANG ; Shan FENG ; Shuo-Han LIN
Chinese Medical Equipment Journal 2024;45(9):78-83
YY 0585.4-2009 and ISO 8536-12:2021 standards were compared in terms of the blocking performance test method of disposable check valves for infusion equipment.The affecting factors and possible errors were analyzed when the blocking performance test was carried out according to YY 0585.4-2009,and it's pointed out ISO 8536-12:2021 gained advantages over YY 0585.4-2009 in the blocking performance test method of check valves.References and guidance were provided for standard revision and actual operation.[Chinese Medical Equipment Journal,2024,45(9):78-83]


Result Analysis
Print
Save
E-mail