1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Analysis and clinical characteristics of SLC26A4 gene mutations in 72 cases of large vestibular aqueduct syndrome.
Yuqing LIU ; Wenyu XIONG ; Yu LU ; Lisong LIANG ; Kejie YANG ; Li LAN ; Wei HAN ; Qing YE ; Min WANG ; Yuan ZHANG ; Fangying TAO ; Zuwei CAO ; Wei HUANG ; Xue YANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(7):603-609
Objective:To explore the genetic and clinical characteristics of Guizhou patients with enlarged vestibular aqueduct(EVA) syndrome through combined SLC26A4 variant analysis and clinical phenotype analysis. Methods:Seventy-two EVA patients underwent comprehensive genetic testing using a multiplex PCR-based deafness gene panel and next-generation sequencing(NGS). The audiological and temporal bone imaging characteristics were compared across mutation subtypes. Results:A total of 27 pathogenic loci of SLC26A4 were detected in 72 patients, including c.919-2A>G in 79.2%(57/72). A novel deletion(c.1703_1707+6del) was discovered. Among 65 cases, truncated mutations were 89.2%(58/65), 52.3%(34/65), 28(43.1%) and 7(10.8%). No significant differences were observed in the midpoint diameter of the vestibular aqueduct and the incidence of incomplete partitioning typeⅡ(IP-Ⅱ) of the cochlea among the three groups of patients. Moreover, there was no difference in the midpoint diameter of different vestibular pipes or the combination with IP-Ⅱ. Conclusion:The most common mutation site of SLC26A4 in EVA patients in Guizhou is c.919-2A>G, though genotype-phenotype correlations remain elusive. The detection of 27 mutation sites and the discovery of new mutation sites suggested the precise diagnostic significance of NGS technology in EVA patients in Guizhou.
Humans
;
Sulfate Transporters
;
Vestibular Aqueduct/abnormalities*
;
Mutation
;
Membrane Transport Proteins/genetics*
;
Hearing Loss, Sensorineural/genetics*
;
Male
;
Female
;
Child
;
Adolescent
;
Child, Preschool
;
Adult
;
Young Adult
;
Phenotype
;
High-Throughput Nucleotide Sequencing
7.Metabolomics as an emerging tool for the pharmacological and toxicological studies on Aconitum alkaloids.
Han DING ; Yamin LIU ; Sifan WANG ; Yuqi MEI ; Linnan LI ; Aizhen XIONG ; Zhengtao WANG ; Li YANG
Chinese Journal of Natural Medicines (English Ed.) 2025;23(2):182-190
Aconitum (Ranunculaceae) has a long-standing history in traditional Chinese medicine (TCM), where it has been widely used to treat conditions such as rheumatoid arthritis (RA), myocardial infarction, and heart failure. However, the potency of Aconitum alkaloids, the primary active components of Aconitum, also confers substantial toxicity. Therefore, assessing the efficacy and toxicity of these Aconitum alkaloids is crucial for ensuring clinical effectiveness and safety. Metabolomics, a quantitative method for analyzing low-molecular-weight metabolites involved in metabolic pathways, provides a comprehensive view of the metabolic state across multiple systems in vivo. This approach has become a vital investigative tool for facilitating the evaluation of their efficacy and toxicity, identifying potential sensitive biomarkers, and offering a promising avenue for elucidating the pharmacological and toxicological mechanisms underlying TCM. This review focuses on the applications of metabolomics in pharmacological and toxicological studies of Aconitum alkaloids in recent years and highlights the significant role of metabolomics in exploring compatibility detoxification and the mechanisms of TCM processing, aiming to identify more viable methods for characterizing toxic medicinal plants.
Aconitum/metabolism*
;
Metabolomics/methods*
;
Alkaloids/metabolism*
;
Humans
;
Animals
;
Drugs, Chinese Herbal/pharmacology*
;
Medicine, Chinese Traditional
8.Role of mitochondrial biogenesis in rat model of coal workers' pneumoconiosis based on PGC-1α-NRF1-TFAM signaling pathway
Mei ZHANG ; Xiaoqiang HAN ; Lulu LIU ; Yan WANG ; Xin MA ; Yu XIONG ; Huifang YANG ; Na ZHANG
Journal of Environmental and Occupational Medicine 2025;42(12):1429-1437
Background Mitochondrial biogenesis is pivotal in coal workers' pneumoconiosis fibrosis, yet the role of the peroxisome proliferator-activated receptor gamma coactivator 1-alpha (PGC-1α)-nuclear respiratory factor 1 (NRF1)-mitochondrial transcription factor A (TFAM) pathway inmitochondrial biogenesis remains elusive, warranting further investigation. Objective To elucidate the role of the PGC-1α-NRF1-TFAM pathway in mitochondrial biogenesis in a rat coal workers' pneumoconiosis model through in vivo and in vitro experiments. Methods (1)n vivo: twelve SPF male SD rats (200-220 g) were randomized into a control group and a coal dust group (n=6 per group). After acclimatization, the coal dust group received 1 mL 50 mg·mL−1 coal dust suspension via intratracheal instillation; the controls received saline. Lung tissues were harvested after two months for histopathology [HE, Masson, and transmission electron microscopy (TEM) ], protein and mRNA analysis, and mitochondrial DNA (mtDNA) quantification by quantitative real-time polymerase chain reaction (qPCR). (2) In vitro: rat lung type II epithelial cells (RLE-6TN) cells were exposed to coal dust (50, 100, 200, and 400 mg·L−1, 24 h). CCK-8 assay determined optimal doses. Ultrastructural changes were analyzed by TEM. Cells were transfected with OE-PGC-1α (PGC-1α overexpression) or shRNA-PGC-1α plasmids (PGC-1α knockdown), and the transfection efficiency was determined by reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR). The expression levels of alpah-smooth muscle actin (α-SMA), citrate synthase (CS), PGC-1α, NRF1, TFAM, and fibronectin (Fn) proteins and their corresponding mRNA were detected using Western blot and RT-qPCR, respectively. The relative content of mtDNA was determined by qPCR. Results In vivo: the control group lung samples exhibited soft, pink parenchyma, while the coal dust-exposed lungs showed blackened surfaces with soft texture. The histopathological evaluation revealed intact alveolar walls in the controls versus structural destruction, micro-nodules, and fibrotic areas in the coal dust group. After Masson staining, coal dust deposits were found surrounded by blue collagen fibers in the exposed lungs, but absent in the controls. The coal dust group displayed significant upregulation of fibrotic marker α-SMA and downregulation of mitochondrial biogenesis markers (CS, PGC-1α, NRF1, TFAM) and mtDNA compared to the controls (P<0.05). In vitro: coal dust exposure reduced cell density and induced morphological alterations. TEM revealed evenly distributed normal mitochondria in controls versus mitochondrial swelling, disrupted cristae, and reduced numbers in exposed cells. The mitochondrial biogenesis markers were elevated in the coal dust + OE-PGC-1α group compared to the coal dust + OE-NC group (P<0.05); in contrast, they were decreased in the coal dust + shRNA-PGC-1α group compared to the coal dust + shRNA-NC group (P<0.05). Compared to the control group, the expression levels of the fibrosis marker α-SMA mRNA and protein were increased in the coal dust group (P<0.05). Overexpression of PGC-1α reduced α-SMA expression, while downregulation of PGC-1α increased its expression (P<0.05). Conclusion Coal dust exposure induces mitochondrial dysfunction and pulmonary fibrosis in vivo and in vitro via the PGC-1α-NRF1-TFAM pathway dysregulation. Targeting this pathway may mitigate coal dust-induced fibrosis by restoring mitochondrial biogenesis.
9.Heterologous expression and product identification of diterpene synthase involved in the biosynthesis of brasilicardin A
Xiang-yu GE ; Guang-xin ZHOU ; Na XIONG ; Zi-han LU ; Xin-yu MI ; Zhi-xiang ZHU ; Xiao LIU ; Xiao-hui WANG ; Juan WANG ; She-po SHI
Acta Pharmaceutica Sinica 2024;59(7):2161-2170
Brasilicardin A, a diterpene glycoside isolated from pathogenic actinomycete
10.Tricuspid Valve Geometry of Idiopathic Pulmonary Hypertension:a Three-dimensional Transthoracic Echocardiography Study
Yawen WANG ; Lili NIU ; Bingyang LIU ; Minjie LU ; Changming XIONG ; Ning HAN ; Hao WANG ; Weichun WU ; Zhenhui ZHU
Chinese Circulation Journal 2024;39(2):171-176
Objectives:To evaluate the tricuspid valve(TV)geometric remodeling in patients with idiopathic pulmonary arterial hypertension(IPAH)by three-dimensional transthoracic echocardiography. Methods:Two-dimensional and three-dimensional transthoracic echocardiography were performed in 30 IPAH patients and 15 healthy controls,and the geometry parameters of TV were obtained by four-dimensional auto tricuspid valve quantitative(4D Auto-TVQ)in the right ventricular-focused apical view.Pulmonary arterial hypertension was determined by right heart catheterization within 48 hours of echocardiography. Results:The 4-chamber diameter,tricuspid annular(TA)perimeter,TA area,maximal tenting height,coaptation point height and tenting volume were larger in IPAH patients than those in healthy controls(all P<0.05),2-chamber diameter was similar between two groups.In IPAH group,maximal tenting height and coaptation point height were moderately correlated with right ventricular end-diastolic volume(r=0.710,r=0.515,both P<0.05),while TA perimeter,4-chamber diameter and TA area were moderately correlated with right atrial end-systolic volume(r=0.712,r=0.558,r=0.545,all P<0.05). Conclusions:IPAH patients have larger maximal tenting height,coaptation point height and tenting volume,TA enlargement is mainly visible in 4-chamber diameter.TV tenting height is associated with right ventricular volume,but TA size is associated with right atrial volume in IPAH patients.

Result Analysis
Print
Save
E-mail