1.Percutaneous endoscopic discectomy with lateral approach and dual-channel method for the treatment of highly free lumbar disc herniation.
Qi-Ming CHEN ; Chun-Hua YU ; Gang CHEN ; Han-Rong XU ; Yi-Biao JING ; Yin-Jiang LU ; Shan-Chun TAO ; Jian-Bo WU
China Journal of Orthopaedics and Traumatology 2025;38(9):924-929
OBJECTIVE:
To explore clinical efficacy of percutaneous endoscopic discectomy with a lateral approach and dual-channel method in treating highly free lumbar disc herniation(LDH).
METHODS:
A retrospective analysis was conducted on 54 patients with highly free LDH who were treated with spinal endoscopic techniques from January 2021 to December 2022. Twenty-seven patients were treated with lateral approach dual-channel(lateral approach dual-channel group), including 16 males and 11 females, with an average age of (54.6±10.5) years old. Twenty-seven patients were treated with unilateral biportal endoscopic (UBE group), including 17 males and 10 females, with an average age of (52.9±12.3) years old. The number of intraoperative fluoroscopy, operation time and hospital stay, as well as visual analogue scale (VAS) and Oswestry diability index (ODI) of low back and leg pain between two patients before operation, 1 day, 1, 3, and 12 months after operation, and the efficacy was evaluated by the modified MacNab criteria at 12 mohths after operation.
RESULTS:
All patients were successfully completed surgical and were followed up, the time raged from 12 to 22 months with an average of (13.57±4.12) months. There was no statistically significant difference in operation time between two groups (P>0.05). The hospital stay of lateral approach dual-channel group was (3.9±1.1) days, which was shorter than that of UBE group (6.5±1.4) days, the number of intraoperative fluoroscopy in lateral approach dual-channel group was (12.7±2.1) times, which was more than that in UBE group (6.6±1.3) times, the differences were statistically significant (t=5.197, -7.532;P<0.05). VAS and ODI for low back pain at 1 day and 1 month after operation, and VAS for leg pain at 1 day after operation of lateral approach dual-channel group were superior to those of UBE group, and the differences were statistically significant (P<0.05). However, there were no statistically significant differences in VAS and ODI for low back and leg pain between two groups before operation and 3 and 12 months after operation (P>0.05). VAS and ODI of low back and leg pain were significantly improved at each time point before and after operation in both groups, and the difference were statistically significant (P<0.05). At 12 months after operation, according to the modified MacNab criteria, the excellent and good rates of therapeutic effects between lateral approach dual-channel group and UBE group were 92.6% (25/27) and 88.9% (24/27), respectively, and the difference was not statistically significant (χ2=0.22, P>0.05).
CONCLUSION
For patients with highly free lumbar intervertebral disc protrusion, both of lateral approach dual-channel method and UBE endoscopic surgery are safe and effective. Endoscopic surgery with lateral approach and dual-channel method could be performed under local anesthesia, allowing for the removal of the nucleus pulposus under direct vision. It is simpler, more efficient.
Humans
;
Male
;
Female
;
Intervertebral Disc Displacement/surgery*
;
Middle Aged
;
Diskectomy, Percutaneous/methods*
;
Lumbar Vertebrae/surgery*
;
Endoscopy/methods*
;
Adult
;
Retrospective Studies
;
Aged
2.Efficacy Prediction of Platelet Count Trajectories after Induction Therapy with Venetoclax Combined with Azacitidine in Newly Diagnosed AML Patients.
Qian-Ying MA ; Xiao-Rui JING ; Han-Chun WANG ; Hui-Rong WU ; Juan CHENG
Journal of Experimental Hematology 2025;33(2):331-338
OBJECTIVE:
To investigate platelet count trajectories after induction therapy with venetoclax combined with azacitidine (VA regimen) in newly diagnosed AML patients and further analyze its clinical significance.
METHODS:
Clinical date of 50 newly diagnosed AML patients who received VA treatment from March 2020 to July 2023 in Department of Hematology of the First Hospital of Lanzhou University were retrospectively collected. The platelet trajectories after induction chemotherapy were constructed by using group-based trajectory modeling. To study the association between diverse trajectories of platelet counts and compound complete remission (cCR) rate, overall response rate (ORR), minimal residual disease (MRD) negative rate and overall survival (OS) rate. The Cox proportional hazard model was used to evaluate the relationship between platelet trajectory and OS. The logistic regression was used to analyze the influence of individual characteristics on platelet trajectory.
RESULTS:
Two platelet trajectories were identified based on the model, including platelet slowly increased group (n=31, 62.0%) and platelet rapidly increased group (n=19, 38.0%). There were statistically significant differences in cCR rate, ORR and OS rate between platelet slowly increased group and platelet rapidly increased group (all P < 0.05). The Cox regression analysis showed that platelet rapidly increased group was associated with a decreased risk of mortality compared with platelet slowly increased group (HR=0.153, 95%CI : 0.045-0.527, P =0.003). Logistic regression analysis showed that IDH1/2 mutation (OR =3.908, 95%CI : 1.023-14.923, P =0.046) and platelet transfusion (OR =0.771, 95%CI : 0.620-0.959, P =0.020) were independent influencing factors of platelet trajectory.
CONCLUSION
The dynamic trajectory of platelet counts in newly diagnosed AML patients who received VA treatment can serve as a significant indicator to observe the efficacy and prognosis. The platelet rapidly increased is an independent protective factor for good prognosis. TheIDH1 /2 mutation and platelet transfusion are independent influencing factors of platelet trajectory.
Humans
;
Leukemia, Myeloid, Acute/blood*
;
Sulfonamides/administration & dosage*
;
Azacitidine/therapeutic use*
;
Platelet Count
;
Retrospective Studies
;
Bridged Bicyclo Compounds, Heterocyclic/administration & dosage*
;
Male
;
Female
;
Antineoplastic Combined Chemotherapy Protocols/therapeutic use*
;
Induction Chemotherapy
;
Survival Rate
3.Susceptible Windows of Prenatal Ozone Exposure and Preterm Birth: A Hospital-Based Observational Study.
Rong Rong QU ; Dong Qin ZHANG ; Han Ying LI ; Jia Yin ZHI ; Yan Xi CHEN ; Ling CHAO ; Zhen Zhen LIANG ; Chen Guang ZHANG ; Wei Dong WU ; Jie SONG
Biomedical and Environmental Sciences 2025;38(2):255-260
4.Untargeted Metabolomics of Plasma From Coronavirus Disease 2019 Patients One Year After Recovery.
Xu-Tong ZHANG ; Ye-Hong YANG ; Yue WU ; Rong HAN ; Qiao-Chu WANG ; Tao DING ; Jiang-Feng LIU ; Jun-Tao YANG
Acta Academiae Medicinae Sinicae 2025;47(4):519-526
Objective To investigate the recovery of plasma metabolism in asymptomatic and mild patients of coronavirus disease 2019(COVID-19)one year after recovery.Methods A total of 174 participants were recruited from the communities in Wuhan,including 80 healthy volunteers and the COVID-19 patients who had recovered for one year.According to the disease severity,the recovered COVID-19 patients were grouped as asymptomatic patients(n=80)and mild patients(n=14).The liquid chromatography mass spectrometry platform was employed to study the metabolomic characteristics of the plasma from all the participants.Results The plasma metabolites in asymptomatic patients and mild patients remained abnormal compared with those in healthy volunteers.Among the differential metabolites in asymptomatic patients and mild patients,some metabolites showed a downward trend only in mild patients,such as phosphatidylethanolamine[20∶3(5Z,8Z,11Z)/P-18∶0],sphingomyelin(d18∶1/24∶0),and cholesteryl(15∶0).The metabolic pathway involving the differential metabolites in mild patients was mainly glycerophospholipid metabolism.Conclusions Even one year after recovery,the mild COVID-19 patients still exhibit metabolic abnormalities.Hence,these patients may experience an extended period of time for recovery.
Humans
;
COVID-19/metabolism*
;
Metabolomics
;
SARS-CoV-2
;
Metabolome
;
Female
;
Male
;
Adult
;
Middle Aged
5.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
6.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
7.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
8.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
9.Genetic Variation of SH2B3 in Patients with Myeloid Neoplasms
Qiang MA ; Rong-Hua HU ; Hong ZHAO ; Xiao-Xi LAN ; Yi-Xian GUO ; Xiao-Li CHANG ; Wan-Ling SUN ; Li SU ; Wu-Han HUI
Journal of Experimental Hematology 2024;32(4):1186-1190
Objective:To observe the genetic variation of SH2B3 in patients with myeloid neoplasms.Methods:The results of targeted DNA sequencing associated with myeloid neoplasms in the Department of Hematology,Xuanwu Hospital,Capital Medical University from November 2017 to November 2022 were retrospectively analyzed,and the patients with SH2B3 gene mutations were identified.The demographic and clinical data of these patients were collected,and characteristics of SH2B3 gene mutation,co-mutated genes and their correlations with diseases were analyzed.Results:The sequencing results were obtained from 1 005 patients,in which 19 patients were detected with SH2B3 gene mutation,including 18 missense mutations(94.74%),1 nonsense mutation(5.26%),and 10 patients with co-mutated genes(52.63%).Variant allele frequency(VAF)ranged from 0.03 to 0.66.The highest frequency mutation was p.Ile568Thr(5/19,26.32%),with an average VAF of 0.49,involving 1 case of MDS/MPN-RS(with SF3B1 mutation),1 case of MDS-U(with SF3B1 mutation),1 case of aplastic anemia with PNH clone(with PIGA and KMT2A mutations),2 cases of MDS-MLD(1 case with SETBP1 mutation).The other mutations included p.Ala567Thr in 2 cases(10.53%),p.Arg566Trp,p.Glu533Lys,p.Met437Arg,p.Arg425Cys,p.Glu314Lys,p.Arg308*,p.Gln294Glu,p.Arg282Gln,p.Arg175Gln,p.Gly86Cys,p.His55Asn and p.Gln54Pro in 1 case each.Conclusion:A wide distribution of genetic mutation sites and low recurrence of SH2B3 is observed in myeloid neoplasms,among of them,p.Ile568Thr mutation is detected with a higher incidence and often coexists with characteristic mutations of other diseases.
10.Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome (version 2024)
Junyu WANG ; Hai JIN ; Danfeng ZHANG ; Rutong YU ; Mingkun YU ; Yijie MA ; Yue MA ; Ning WANG ; Chunhong WANG ; Chunhui WANG ; Qing WANG ; Xinyu WANG ; Xinjun WANG ; Hengli TIAN ; Xinhua TIAN ; Yijun BAO ; Hua FENG ; Wa DA ; Liquan LYU ; Haijun REN ; Jinfang LIU ; Guodong LIU ; Chunhui LIU ; Junwen GUAN ; Rongcai JIANG ; Yiming LI ; Lihong LI ; Zhenxing LI ; Jinglian LI ; Jun YANG ; Chaohua YANG ; Xiao BU ; Xuehai WU ; Li BIE ; Binghui QIU ; Yongming ZHANG ; Qingjiu ZHANG ; Bo ZHANG ; Xiangtong ZHANG ; Rongbin CHEN ; Chao LIN ; Hu JIN ; Weiming ZHENG ; Mingliang ZHAO ; Liang ZHAO ; Rong HU ; Jixin DUAN ; Jiemin YAO ; Hechun XIA ; Ye GU ; Tao QIAN ; Suokai QIAN ; Tao XU ; Guoyi GAO ; Xiaoping TANG ; Qibing HUANG ; Rong FU ; Jun KANG ; Guobiao LIANG ; Kaiwei HAN ; Zhenmin HAN ; Shuo HAN ; Jun PU ; Lijun HENG ; Junji WEI ; Lijun HOU
Chinese Journal of Trauma 2024;40(5):385-396
Traumatic supraorbital fissure syndrome (TSOFS) is a symptom complex caused by nerve entrapment in the supraorbital fissure after skull base trauma. If the compressed cranial nerve in the supraorbital fissure is not decompressed surgically, ptosis, diplopia and eye movement disorder may exist for a long time and seriously affect the patients′ quality of life. Since its overall incidence is not high, it is not familiarized with the majority of neurosurgeons and some TSOFS may be complicated with skull base vascular injury. If the supraorbital fissure surgery is performed without treatment of vascular injury, it may cause massive hemorrhage, and disability and even life-threatening in severe cases. At present, there is no consensus or guideline on the diagnosis and treatment of TSOFS that can be referred to both domestically and internationally. To improve the understanding of TSOFS among clinical physicians and establish standardized diagnosis and treatment plans, the Skull Base Trauma Group of the Neurorepair Professional Committee of the Chinese Medical Doctor Association, Neurotrauma Group of the Neurosurgery Branch of the Chinese Medical Association, Neurotrauma Group of the Traumatology Branch of the Chinese Medical Association, and Editorial Committee of Chinese Journal of Trauma organized relevant experts to formulate Chinese expert consensus on the diagnosis and treatment of traumatic supraorbital fissure syndrome ( version 2024) based on evidence of evidence-based medicine and clinical experience of diagnosis and treatment. This consensus puts forward 12 recommendations on the diagnosis, classification, treatment, efficacy evaluation and follow-up of TSOFS, aiming to provide references for neurosurgeons from hospitals of all levels to standardize the diagnosis and treatment of TSOFS.

Result Analysis
Print
Save
E-mail