1.Management and practice of ethical review for “amendment” in drug clinical trials
Xingyi LI ; Zhonglin CHEN ; Xingchi QU ; Yu FENG ; Huihui HAN
Chinese Medical Ethics 2026;39(1):58-63
Driven by the growing practical need to accelerate drug development and the continuous innovation of trial design in recent years, the number of protocol amendments during clinical trials have gradually increased, and the changed contents have become more flexible and complex, which significantly heightens the difficulty of ethical review on amendments. Against this backdrop, it is of great importance to fully leverage the role and responsibilities of ethics committees, effectively control clinical trial risks, and ensure subject safety. This paper analyzed development trends of protocol amendments in recent years, sorted out requirements for protocol amendments in Chinese regulations and guiding principles, and examined difficulties of amendment ethical review in practical work. Based on these, targeted strategies and recommendations were proposed, namely, strengthening the integration with scientific review, enhancing the formal review, adjusting the scope of review according to approval notifications, and adopting appropriate review methods, with a view to providing insights and references for the management of the amendment ethical review in drug clinical trials.
2.Current quality status and management countermeasures of occupational health technical services in Zhejiang Province
Qiuliang XU ; Feng HAN ; Peng WANG ; Zhen ZHOU ; Fei LI ; Hongwei XIE ; Yong HU ; Weiming YUAN ; Lifang ZHOU ; Hua ZOU
Journal of Environmental and Occupational Medicine 2026;43(3):341-346
Background The quality of occupational health technical services is directly linked to the protection of workers' health rights and the efficacy of occupational disease prevention and control. However, the industry still faces critical challenges: sporadic instances of institutional non-compliance and persistent irregularities in professional practice continue to undermine overall service performance. Objective To assess the current quality status of occupational health technical services in Zhejiang Province and propose countermeasures for quality improvement, providing a scientific basis for policy optimization and service delivery quality enhancement. Methods A total of 69 occupational health technical service institutions in Zhejiang Province that obtained formal accreditation as of April 30, 2024, were sampled, including 3 public institutions and 66 private institutions (comprising 3 formerly Class-A, 28 formerly Class-B, 11 formerly Class-C, and 24 newly certified institutions). Following the Technical Protocol for Quality Monitoring of Occupational Health Technical Service in Zhejiang Province and the Technical Protocol for Proficiency Testing of Occupational Health Detection in Zhejiang Province, a quality assessment task force comprising national and provincial experts was established. Evaluation was conducted across four dimensions: qualification maintenance and compliance, standardization of technical services, authenticity of technical services, and proficiency testing, utilizing a combination of document review, on-site inspections, and technical skill assessments. Results The occupational health technical service institutions in Zhejiang Province were predominantly private entities (82.5%), with significant disparities in overall service quality. The pass rates for qualification maintenance and compliance, technical service standardization, technical service authenticity, and the excellence rate for laboratory proficiency testing were 81.5%, 80.7%, 97.3%, and 90.4%, respectively. Regarding qualification maintenance, the pass rates for "environmental conditions" (49.8%, 56.7%) and "instrumentation and equipment" (58.2%、65.6%) were significantly lower for formerly Class-C and newly certified institutions compared to other categories. In terms of technical standardization, "standardized on-site inspections" recorded the lowest pass rate (67.4%), with newly certified institutions at only 48.0%. Regarding technical service authenticity, formerly Class-C institutions exhibited issues such as missing raw chromatograms for blank samples (85.7% pass rate). In laboratory proficiency testing, public and formerly Class-A institutions achieved 100% excellence rates, but the performance of formerly Class-C and newly certified institutions was comparatively weak; specifically, the failure rate for organic analysis in formerly Class-C institutions reached 20%; the failure rate for dust testing items in newly certified institutions was 10.3%. Conclusion The overall quality of occupational health technical services in Zhejiang Province still requires significant improvement, particularly in basic institutional conditions, the standardization of on-site inspections, and laboratory proficiency in organic and dust analysis. Formerly Class-C and newly certified institutions should be the primary focus of quality management efforts. Differentiated regulatory strategies are recommended, alongside strengthening interim and ex-post supervision to gradually enhance the quality of occupational health technical services across all institutions.
3.Three-dimensional Electrical Impedance Tomography for Monitoring Gastric Hemorrhage
Zi-Han ZHAO ; Bo SUN ; Jing-Shi HUANG ; Zhi-Wei LI ; Yang WU ; Nan LI ; Jia-Feng YAO ; Tong ZHAO
Progress in Biochemistry and Biophysics 2026;53(4):1062-1075
ObjectiveGastric hemorrhage is one of the most common and life-threatening emergencies of the upper digestive tract. Early identification and continuous monitoring are essential for reducing rebleeding rates and mortality, particularly within the critical early hours after onset. Although endoscopy and radiological imaging can accurately localize bleeding sites, these approaches are invasive, resource-intensive, and unsuitable for continuous bedside monitoring. Electrical impedance tomography (EIT), as a noninvasive and radiation-free functional imaging technique, offers real-time visualization of conductivity distribution and has the potential for detecting intragastric bleeding based on the electrical contrast between blood and surrounding gastric tissues. In this study, a three-dimensional gastric EIT (3D-gEIT) framework is proposed to achieve noninvasive, real-time, and dynamic monitoring of gastric hemorrhage, with emphasis on spatial localization and quantitative volume assessment. MethodsA three-dimensional upper-abdominal simulation model incorporating the stomach, gastric wall, gastric contents, and surrounding tissues was established. Three electrode configurations, namely the dual layer ring, the four layer staggered ring, and the opposed dual plane array, were designed and systematically compared to evaluate their influence on depth sensitivity and spatial resolution. Based on the Tikhonov-Noser hybrid regularization scheme, a region-clustering constraint was introduced to develop the TK-Noser-RCC algorithm. This approach aggregates spatially adjacent elements with similar conductivity variations, thereby enhancing structural continuity and suppressing isolated noise artifacts. To validate the proposed framework, an upper-abdominal physical phantom was constructed using agar to simulate background tissue conductivity. Hemispherical high-conductivity inclusions with volumes ranging from 10 ml to 50 ml were attached to the inner gastric wall to mimic localized bleeding under different gastric filling states. Boundary voltages were acquired under a 120 kHz excitation current and reconstructed using the TK-Noser-RCC algorithm. Furthermore, an in vivo animal experiment was performed using a porcine model with adult-scale abdominal dimensions. A total of 100 ml of autologous blood was injected incrementally into the stomach to simulate progressive gastric hemorrhage, and time-difference EIT reconstruction was conducted at each injection stage to assess the dynamic system response under physiological conditions. ResultsSimulation results demonstrated that the opposed dual-plane electrode array achieved superior depth sensitivity distribution and spatial resolution. For a 40 ml hemorrhage model, the average ICC and SSIM improved by 55.9% and 38.8% compared with the dual-layer ring configuration, and by 64.0% and 39.5% compared with the four-layer staggered configuration. The proposed region-clustering constraint significantly enhanced reconstruction stability. Under added Gaussian noise of 40 dB and 30 dB, ICC values remained approximately 0.85, indicating effective artifact suppression and preservation of boundary integrity. In physical phantom experiments, reconstructed hemorrhage volumes increased approximately linearly with the preset hemispherical volumes, and the reconstructed high-conductivity regions closely matched the actual bleeding locations. Both empty-stomach and full-stomach conditions were evaluated, demonstrating that the opposed dual-plane configuration maintained stable imaging performance across varying gastric contents. In the animal experiment, reconstructed low-impedance regions expanded progressively with increasing injected blood volume. The spatial localization of the hemorrhage remained stable throughout the procedure, and no significant artifacts were observed. Quantitative analysis showed that reconstructed volume and average conductivity variation exhibited an approximately linear growth trend with injected blood volume, confirming the sensitivity of the system to dynamic intragastric conductivity changes. ConclusionThe proposed 3D-gEIT framework enables quantitative reconstruction of gastric hemorrhage volume and spatial distribution with improved depth sensitivity, structural continuity, and noise robustness compared with conventional EIT approaches. By integrating optimized electrode configuration and a region-clustering-constrained reconstruction algorithm, the system provides stable dynamic monitoring under both controlled phantom conditions and in vivo physiological environments. This method offers a noninvasive, real-time, and low-cost imaging strategy for early diagnosis, postoperative monitoring, and bedside surveillance of gastric bleeding.
4.Research on quality control of the potential allergic ingredient scutellarin in Shuganning Injection
HE Feng ; CAO Lu ; YANG Cuiping ; LI Jing ; ZHANG Quan ; WANG Jinjin ; L& ; #252 Yanni ; HAN Shengli
Drug Standards of China 2026;27(1):0037-0042
Objective: Scutellarin in Shuganning injection has potential allergenicity and is prone to causing anaphylactoid reactions. There is an urgent need to establish a simple and rapid chromatographic quantitative method to achieve the limit control of scutellarin in Shuganning injection.
Methods: For scutellarin, HPLC method was used in the quantitative analysis using a Shim-pack GIS C18 (2.1 mm×150 mm, 5 μm) column. The mobile phase was a blend of 0.1% trifluoroacetic acid in water and acetonitrile, and gradient elution progress was applied for the whole process. The flow rate was 0.3 mL·min-1 and the column temperature was maintained at 37 ℃. The detecting wavelength was 320 nm.
Results: The linear regression equation was y=51 456x-27 352, the correlation coefficient r=0.999 8, namely the calibration curve was linear in the range of 1.02-102.00 μg·mL-1; the average recovery was 103.76%; the detection and quantification limit for determining scutellarin was 0.16 μg·mL-1 and 0.57 μg·mL-1, respectively; the injection sample was stable at room temperature for 48 h.
Conclusion: This method is easy to operate, reproducible and has high accuracy, thus can be used for quality control of Shuganning injection.
5.SIZ1 and ESD4 Mediate The Reversible SUMOylation of SnRK2.6 Through Direct Physical Interaction
Huan-Huan FU ; Jian WEI ; Meng-Yao LI ; Yong-Feng HAN
Progress in Biochemistry and Biophysics 2026;53(7):1984-1999
ObjectiveTo investigate the novel post-translational modifications (PTMs) of SnRK2.6, a central component in the abscisic acid (ABA) signaling pathway, such as SUMOylation, and to establish a foundation for revealing the physiological functions and molecular mechanisms of SnRK2.6 regulated by these new modifications. MethodsThe interaction between SnRK2.6 and the SUMO E3 ligase SIZ1, as well as members of the SUMO protease family, was examined using yeast two-hybrid and in vitro pull-down assays. An in vitro SUMOylation system in Escherichia coli was utilized to determine whether SnRK2.6 undergoes SUMOylation. Mass spectrometry, combined with site-directed mutagenesis of candidate lysine residues, was employed to identify potential SUMOylation sites on SnRK2.6. In vitro de-SUMOylation assays were performed to assess whether SUMO proteases interacting with SnRK2.6 could catalyze the removal of SUMO moieties from modified SnRK2.6. The protein stability of SnRK2.6 was assessed in a cell-free degradation assay using bacterial-purified SnRK2.6 incubated with total protein extracts from Col and siz1 mutant seedlings. To dissect the genetic relationship between SnRK2.6 and SIZ1, stomatal aperture assays were performed under ABA treatment using snrk2.6, siz1, and snrk2.6 siz1 double mutant plants. ResultsSnRK2.6 physically interacts with SIZ1 and the SUMO protease ESD4, with the binding domains localized to the C-terminal region of SIZ1 and the N-terminal region of ESD4, respectively. SnRK2.6 was found to be SUMOylated, exhibiting two distinct high-molecular-mass bands ranging from 70 to 100 ku, indicative of modified forms. Bioinformatics analysis predicted four putative SUMOylation sites on lysine residues K57, K63, K142, and K190. Mass spectrometry identified three SUMOylation sites on K63, K142, and K174. However, individual or combinatorial point mutations on these sites had minimal impact on the pattern or intensity of SUMOylation signals, suggesting that these residues may not be responsible for the SUMOylation on SnRK2.6. Instead, such mutations only weaken the protein stability or accelerate the protein mobility of SnRK2.6. Therefore, the exact SUMOylation sites on SnRK2.6 remain unidentified. In de-SUMOylation experiments, incubation of GST-ESD4 with SUMOylated SnRK2.6 for 1-2 h led to the near-complete disappearance of both SUMOylated bands. In contrast, neither the GST control nor the catalytically inactive mutant GST-ESD4C448S exhibited any de-SUMOylation activity. In protein turnover experiments, SnRK2.6 exhibited markedly enhanced half-life in siz1 compared with Col, indicating that SIZ1-dependent SUMOylation promotes SnRK2.6 turnover. Phenotypically, snrk2.6 mutants were completely insensitive to ABA-induced stomatal closure; siz1 mutants displayed pronounced hypersensitivity; and the snrk2.6 siz1 double mutant phenocopied snrk2.6—showing no significant response to ABA beyond that of the snrk2.6 mutant. These data indicate that SIZ1 acts as a negative regulator of ABA-triggered stomatal closure and SnRK2.6 functions as a positive regulator, and the inhibitory activity of SIZ1 is strictly dependent on SnRK2.6, placing SnRK2.6 genetically upstream of SIZ1 in the ABA signaling pathway. ConclusionSnRK2.6 undergoes SUMOylation, although the specific SUMOylation sites have not been defined. SnRK2.6 is dynamically regulated by reversible SUMOylation—catalyzed by SIZ1 and reversed by ESD4—which controls its protein stability. SUMOylation acts as a destabilizing signal for SnRK2.6, and SIZ1 exerts its negative effect on ABA-triggered stomatal closure probably through promoting SnRK2.6 degradation via SUMOylation. These findings uncover SUMOylation as a critical regulatory layer fine-tuning SnRK2.6 abundance in ABA signaling.
6.Chinese expert consensus on the clinical application of recombinant human thyroid-stimulating hormone (2025 edition)
Chentian SHEN ; Yushen GU ; Hui TAN ; Anren KUANG ; Sijin LI ; Yaming LI ; Jing WANG ; Ningyi JIANG ; Jian TAN ; Zhuoying WANG ; Shaoyan LIU ; Xiaoyi LI ; Jugao FANG ; Dingcun LUO ; Youben FAN ; Hui WANG ; Yuetao WANG ; Xuemei WANG ; Feng WANG ; Wei FU ; Feng SHI ; Xuegong LIU ; Zhongwei LÜ ; Yan XING ; Lin LI ; Hui YANG ; Jun XIN ; Yifan ZHANG ; Yue CHEN ; Yansong LIN ; Wei OUYANG ; Shuzhan YAO ; Changjiu ZHAO ; Xinming ZHAO ; Zairong GAO ; Dingde HUANG ; Qiang WEN ; Xingmin HAN ; Cen LOU ; Weibing MIAO ; Wei FAN ; Quanyong LUO ; Hongcheng SHI
Chinese Journal of Clinical Medicine 2026;33(5):932-944
The recombinant human thyroid-stimulating hormone (rhTSH) can be used for differentiated thyroid cancer (DTC) preparation before 131I therapy, and follow-up. Since its approval by the American Food and Drug Administration (FDA) in 1998, rhTSH has been clinically used in European countries, the United States, and other countries for nearly 30 years. In April 2024, China’s first independently developed rhTSH agent was approved. Based on clinical experience and evidence from domestic and international studies, an expert consensus on the application of rhTSH has been developed following thorough consultations among experts. The consensus offers evidence-based recommendations to guide the appropriate use of rhTSH in clinical practice.
7.Clinical practice guidelines for intraoperative cell salvage in patients with malignant tumors
Changtai ZHU ; Ling LI ; Zhiqiang LI ; Xinjian WAN ; Shiyao CHEN ; Jian PAN ; Yi ZHANG ; Xiang REN ; Kun HAN ; Feng ZOU ; Aiqing WEN ; Ruiming RONG ; Rong XIA ; Baohua QIAN ; Xin MA
Chinese Journal of Blood Transfusion 2025;38(2):149-167
Intraoperative cell salvage (IOCS) has been widely applied as an important blood conservation measure in surgical operations. However, there is currently a lack of clinical practice guidelines for the implementation of IOCS in patients with malignant tumors. This report aims to provide clinicians with recommendations on the use of IOCS in patients with malignant tumors based on the review and assessment of the existed evidence. Data were derived from databases such as PubMed, Embase, the Cochrane Library and Wanfang. The guideline development team formulated recommendations based on the quality of evidence, balance of benefits and harms, patient preferences, and health economic assessments. This study constructed seven major clinical questions. The main conclusions of this guideline are as follows: 1) Compared with no perioperative allogeneic blood transfusion (NPABT), perioperative allogeneic blood transfusion (PABT) leads to a more unfavorable prognosis in cancer patients (Recommended); 2) Compared with the transfusion of allogeneic blood or no transfusion, IOCS does not lead to a more unfavorable prognosis in cancer patients (Recommended); 3) The implementation of IOCS in cancer patients is economically feasible (Recommended); 4) Leukocyte depletion filters (LDF) should be used when implementing IOCS in cancer patients (Strongly Recommended); 5) Irradiation treatment of autologous blood to be reinfused can be used when implementing IOCS in cancer patients (Recommended); 6) A careful assessment of the condition of cancer patients (meeting indications and excluding contraindications) should be conducted before implementing IOCS (Strongly Recommended); 7) Informed consent from cancer patients should be obtained when implementing IOCS, with a thorough pre-assessment of the patient's condition and the likelihood of blood loss, adherence to standardized internally audited management procedures, meeting corresponding conditions, and obtaining corresponding qualifications (Recommended). In brief, current evidence indicates that IOCS can be implemented for some malignant tumor patients who need allogeneic blood transfusion after physician full evaluation, and LDF or irradiation should be used during the implementation process.
8.Study on toxicity-reducing and efficacy-enhancing effects of Polygala tenuifolia compatibility on sand-ironing Strychnos nux-vomica
Yi SUI ; Guo FENG ; Gang LIU ; Keyan LIU ; Xuehao WEI ; Minggang TENG ; Wei LI ; Caiyao HAN ; Yan LEI
China Pharmacy 2025;36(10):1197-1201
OBJECTIVE To explore the effects of Polygala tenuifolia compatibility on toxicity, anti-inflammatory and analgesic efficacy of sand-ironing Strychnos nux-vomica (SS). METHODS The preparation of SS single decoction, SS-P. tenuifolia core-removed (PC) (1∶2.5) or (1∶5) combined decoction, and SS-PC (1∶5) mixture were carried out to investigate their median lethal dose (LD50). Using aspirin as positive control, the number of writhing movements, analgesic rate, pain latency, ear swelling degree and inflammation inhibition rate induced by the above-mentioned medicinal liquids in mice were compared. The contents of the active and toxic components, strychnine and brucine, in the above-mentioned medicinal liquids were also determined. RESULTS The LD50 values of SS single decoction, SS-PC (1∶2.5) combined decoction, SS-PC (1∶5) combined decoction and SS- PC (1∶5) mixture were 302.00, 614.47, 1 445.44 and 1 778.28 mg/kg, respectively. Compared with control group, the number of writhing movements and ear swelling degree in the mice of the above-mentioned medicinal liquid groups were reduced or decreased significantly (P<0.05 or P<0.01); pain latency [at 90 and 120 minutes in the SS single decoction group, at 60 and 90 minutes in the SS-PC (1∶2.5) combined decoction group, and at 60,90, 120 minutes in the SS-PC (1∶5) combined decoction group and SS-PC (1∶5) mixture group] was significantly prolonged (P<0.05 or P<0.01); analgesic rates of the respective medicinal liquids were 39.30%, 70.87%, 80.00% and 82.46%, and inflammation inhibition rates were 38.08%,TD 57.89%, 76.47% and 50.46%; analgesic and anti-inflammatory effects of combined decoction and mixture were generally better than those of the single decoction (P<0.05 or P<0.01). In the above-mentioned four medicinal liquids, the total contents of strychnine were 0.71%, 0.42%, 0.47% and 0.64%, and the total contents of brucine were 0.88%, 0.63%, 0.57% and 0.88%, respectively. CONCLUSIONS The combination of P. tenuifolia can reduce the toxicity of SS and enhance its anti-inflammatory and analgesic effects. Moreover, there is a tendency for the toxicity-reducing and efficacy-enhancing effects to increase with the increasing dosage of P. tenuifolia. Additionally, the combined decoction of SS and P. tenuifolia can reduce the contents of the active and toxic components, strychnine and brucine, in SS.
9.Correlation of corneal α angle and κ angle with lens tilt angle using swept-source optical biometry
Zi-Suo LI ; Zi-Han HE ; Jie ZHOU ; Jian-Feng ZHAO ; Xiao-Ling LUO ; Ya-Li FENG ; Chen YANG ; Yu GENG
Medical Journal of Chinese People's Liberation Army 2025;50(9):1083-1088
Objective To investigate the correlation of corneal α angle and κ angle with lens tilt in normal human eyes using a new swept-source optical biometer.Methods A cross-sectional study was conducted,involving 303 healthy eyes(148 right eyes and 155 left eyes)of patients who visited the First Affiliated Hospital of Kunming Medical University from June to August 2024.ZW-30 swept-source optical biometer was used to collect the lens tilt angle,κ angle(distance from the corneal light reflex to the pupil center),and α angle(distance from corneal light reflex to the corneal geometric center,which is the midpoint of the horizontal white to white(WTW)diameter).The degrees(°)and directions of κ angle and α angle were calculated by the ratio of the above measurements to the anterior chamber depth(ACD)respectively.Spearman correlation analysis and linear regression analysis were employed to evaluate the correlations between the magnitude and direction of corneal α angle,κ angle and lens tilt angle.Results The magnitude and direction of corneal α angle,κ angle,and lens tilt angle in the right eye were as follows respectively:(0.54±0.19)mm(7.81°±3.88°),194.43°±39.75°;(0.27±0.23)mm(4.72°±3.90°),181.07°±79.59°;5.52°±1.67°,188.21°±25.73°.For the left eye,the corresponding values were:(0.47±0.27)mm(8.12°±5.26°),336.04°±46.64°;(0.26±0.27)mm(4.45°±4.80°),322.86°±107.79°;5.50°±1.61°,340.65°±32.84°.Spearman's correlation analysis showed that the correlation coefficients between corneal α angle and lens tilt angle in the right eye were 0.609(distance correlation)and 0.625(angle correlation),while those for κ angle were 0.559(distance correlation)and 0.578(angle correlation).In the left eye,the correlation coefficients between corneal α angle and lens tilt angle were 0.545(distance correlation)and 0.552(angle correlation),and those for κ angle were 0.377(distance correlation)and 0.395(angle correlation).In addition,the correlation coefficient between the direction of corneal α angle and the direction of lens tilt angle in the right eye was 0.343,and that for κ angle direction was 0.284;in the left eye,the correlation coefficients were 0.216(α angle direction)and 0.198(κ angle direction),all with statistical significance(P<0.05).Univariate linear regression analysis showed that lens tilt was positively correlated with both corneal α angle and Kappa angle(P<0.05).Conclusions Corneal α angle and κ angle are highly correlated with lens tilt angle in both eyes,and the correlation of corneal α angle is stronger than that of κ angle in both left and right eyes.The correlation expressed by degree(°)is better than that by distance(mm).It is recommended to refer to the corneal α angle and κ angle expressed in degrees during preoperative evaluation.
10.Three-dimensional digital measurement of proximal femoral bone microstructure in 60-80 years old patients based on Micro-CT
Hui-Ru CHEN ; Tao LÜ ; Chao ZUO ; Yan-Yan BAO ; Yi-Han HU ; Jian-Zhong WANG ; Feng JIN ; Yun-Feng ZHANG ; Hai-Yan WANG ; Xiao-He LI
Acta Anatomica Sinica 2025;56(1):88-94
Objective To observe the difference of bone micro-structure in different regions of proximal femur,micro-CT scanning was performed on 30 proximal femur specimens to explain the mechanism of proximal femur fracture and to provide anatomical basis for prosthesis design.Methods Totally 30 intact proximal femur specimens were obtained from 60-80 year-old cadavers.Micro-CT scanning was used to measure the trabecular thickness(Tb.Th),trabecular number(Tb.N),trabecular space(Tb.Sp),connectivity(Conn)and bone mineral density(BMD)and other parameters in 7 regions of proximal femur,including proximal pressure trabecular(PPT),distal pressure trabecular(DPT),femoral head-neck junction(FHNJ),head and neck of femoral neck(HNFN),the base of femoral neck(BPFN),intertrochanteric line(IL)and greater trochanter(GT).Results The bone mineral density of IL and GT were higher than those of BPFN,FHNJ,DPT and PPT.The trabecular thickness of GT was the largest,followed by IL,BPFN and HNFN,and the smallest was FHNJ,DPT and PPT.The trabecular space of IL was larger than that of GT,and the data of both were larger than those of other parts,among which DPT and PPT were the smallest.The trabecular number of IL and GT were the smallest,BPFN,HNFN and FHNJ were larger,and DPT was the largest.The volume fraction of IL was the smallest,BPFN and HNFN were larger,DPT and PPT were the largest.Conclusion The bone density,trabecular thickness,bone volume,and total volume of GT and IL in the proximal femur of elderly patients are all relatively large,so the reason for the high incidence of fractures is not due to weak internal bone microstructure;The bone density,trabecular thickness,and trabecular gap at the proximal and distal ends of the vertical trabecular bone are relatively small.If it is necessary to perform core decompression for prosthesis filling at this location,the design should be conducive to the mechanical conduction of the prosthesis and the regeneration of surrounding bone tissue.

Result Analysis
Print
Save
E-mail