1.Application of 3D-printed auxiliary guides in adolescent scoliosis surgery.
Dong HOU ; Jian-Tao WEN ; Chen ZHANG ; Jin HUANG ; Chang-Quan DAI ; Kai LI ; Han LENG ; Jing ZHANG ; Shao-Bo YANG ; Xiao-Juan CUI ; Juan WANG ; Xiao-Yun YUAN
China Journal of Orthopaedics and Traumatology 2025;38(11):1119-1125
OBJECTIVE:
To investigate the accuracy and safety of pedicle screw placement using 3D-printed auxiliary guides in scoliosis correction surgery for adolescents.
METHODS:
A retrospective analysis was conducted on the clinical data of 51 patients who underwent posterior scoliosis correction surgery from January 2020 to March 2023. Among them, there were 35 cases of adolescent idiopathic scoliosis and 16 cases of congenital scoliosis. The patients were divided into two groups based on the auxiliary tool used:the 3D-printed auxiliary guide screw placement group (3D printing group) and the free-hand screw placement group (free-hand group, without auxiliary tools). The 3D printing group included 32 patients (12 males and 20 females) with an average age of (12.59±2.60) years;the free-hand group included 19 patients (7 males and 12 females) with an average age of (14.58±3.53) years. The two groups were compared in terms of screw placement accuracy and safety, spinal correction rate, intraoperative blood loss, number of intraoperative fluoroscopies, operation time, hospital stay, and preoperative and last follow-up scores of the Scoliosis Research Society-22 (SRS-22) questionnaire.
RESULTS:
A total of 707 pedicle screws were placed in the two groups, with 441 screws in the 3D printing group and 266 screws in the free-hand group. All patients in both groups successfully completed the surgery. There was a statistically significant difference in operation time between the two groups (P<0.05). The screw placement accuracy rate of the 3D printing group was 95.46% (421/441), among which the Grade A placement rate was 89.34% (394/441);the screw placement accuracy rate of the free-hand group was 86.47% (230/266), with a Grade A placement rate of 73.31% (195/266). There were statistically significant differences in the accuracy of Grade A, B, and C screw placements between the two groups (P<0.05), while no statistically significant differences were observed in intraoperative blood loss, number of fluoroscopies, correction rate, or hospital stay (P>0.05). In the SRS-22 questionnaire scores, the scores of functional status and activity ability, self-image, mental status, and pain of patients in each group at the last follow-up were significantly improved compared with those before surgery (P<0.05), but there were no statistically significant differences in all scores between the two groups (P>0.05).
CONCLUSION
In scoliosis correction surgery, compared with traditional free-hand screw placement, the use of 3D-printed auxiliary guides for screw placement significantly improves the accuracy and safety of screw placement and shortens the operation time.
Humans
;
Male
;
Scoliosis/surgery*
;
Female
;
Adolescent
;
Printing, Three-Dimensional
;
Retrospective Studies
;
Pedicle Screws
;
Child
2.Application review of wearable devices in auxiliary detection and diagnosis of acute mountain sickness
Hui-quan WANG ; Shuai MA ; Guo-sheng CHEN ; Yu GUO ; Jin-han YU ; Zheng-xu YAN ; Ming-hu LIU ; Xin-min DONG
Chinese Medical Equipment Journal 2025;46(9):100-107
The pathological mechanisms and related physiological indicators of acute mountain sickness(AMS)were introduced,and the present situation of wearable devices applied in AMS auxiliary detection and diagnosis were reviewed.The challenges and future development directions of wearable devices applied in auxiliary detection and diagnosis were pointed out.[Chinese Medical Equipment Journal,2025,46(9):100-107]
3.Prediction of Multifunctional Parameters of SPECT Gated Myocardial Perfusion Imaging for Major Adverse Cardiovascular Events in Chronic Kidney Disease
Ying ZHANG ; Zhi CHANG ; Xu HAN ; Jian JIAO ; Zihe YANG ; Quan LI ; Wei DONG ; Hongzhi MI
Chinese Journal of Medical Imaging 2025;33(7):751-757
Purpose To evaluate the predictive value of multifunctional parameters of single photon emission computed tomography gated myocardial perfusion imaging(SPECT G-MPI)for major adverse cardiovascular events(MACE)in chronic kidney disease(CKD)with abnormal stress myocardial perfusion.Materials and Methods A total of 99 patients diagnosed with CKD from June 2017 to March 2024 who underwent stress and rest G-MPI indicating abnormal myocardial perfusion in Beijing Anzhen Hospital,Capital Medical University.The American Heart Association 17-segment 5-point method and PHASE software were used to obtain the left ventricular myocardial perfusion,functional and synchronization parameters.According to the occurrence of MACE,the patients were divided into MACE group and non-MACE group.Cox regression was used to analyze the predictors related to MACE.The receiver operator characteristic curve was used to analyze the performance of predictors,the survival curves were obtained by the Kaplan-Meier method,Log-rank test was used to compare the differences in different groups.Results Finally,we enrolled 99 CKD patients with abnormal stress myocardial perfusion.35 patients(35.35%)developed MACE during the follow-up period.Cox regression analysis showed that stress phase bandwidth(SPBW)(HR=1.015,95%CI 1.002-1.028)and sum difference score(SDS)(HR=1.105,95%CI 1.008-1.211)were independent risk factors for predicting MACE(both P<0.05).The optimal cut-off value of SPBW and SDS for predicting MACE were 69° and 6 points,the area under the curve was 0.801 and 0.778,respectively.The incidence of MACE in the SPBW≥69° group and SDS≥6 points group was higher than that in SPBW<69° group and SDS<6 points group(66.6%vs.13.2%,53.3%vs.20.4%,both P<0.05).Conclusion SPECT G-MPI multifunctional parameters can be used to predict the prognosis of CKD patients with abnormal stress myocardial perfusion.SPBW and SDS are independent risk factors for MACE in these patients.
4.Research on the physical anatomical structure of the Lieque(LU7)acupoint
Chunlin WANG ; Zhaoyu SHU ; Shuai ZHANG ; Quan HAN ; Peigang FANG ; Hengtao QI ; Tiezheng WANG ; Ziyu KANG ; Wenxu ZHANG ; Linjiang WANG ; Qiang WANG ; Likun DONG ; Tao WANG ; Zengtao WANG
Journal of Beijing University of Traditional Chinese Medicine 2025;48(7):992-999
Objective To investigate the anatomical structure and surface location of the Lieque(LU7)acupoint.Methods Firstly,the anatomical localization descriptions of the Lieque(LU7)acupoint from classical medical literature were reviewed and summarized.A total of 21 participants were recruited from Shandong Provincial Hospital Affiliated to Shandong First Medical University from January to March 2025.A Cartesian coordinate system was established over the Lieque(LU7)region on the right forearm.Following standardized manual pressure stimulation,the coordinates of the participant′s reported acupoint sensations were recorded.Based on surface pressure mapping result,10 participants were arbitrarily selected for acupuncture intervention.Upon elicitation of acupoint sensation,the ultrasound imaging was used for real-time visualization of anatomical spatial relationships between the needle tip and distal radial osseous landmarks.Five red latex-perfused adult upper limb specimens were selected for microdissection of the Lieque(LU7)regions pre-localized via ultrasonography,achieving definitive structural characterization of its anatomical strata.Another 10 participants were arbitrarily selected to find the physical structure of the Lieque(LU7)acupoint using ultrasound,and the similarities and differences of acupoint sensation responses were verified using acupuncture needle insertions into both the demarcated zone and peripheral tissues.Results The descriptions of the localization of the Lieque(LU7)acupoint in ancient books can be summarized as"one and a half cun above the wrist side"longitudinally,and"at the intersection head,between two tendons and two bones in the hollow"transversely.During surface pressure application,the sites of the participant′s elicited acupoint sensation were anatomically concentrated in the proximal depression adjacent to the radiopalmar ridge,specifically at the transitional interface between the extensor pollicis brevis tendon and scaphoid bone.During acupuncture-induced acupoint sensation,ultrasound imaging demonstrated that the location of the needle tip was located within the proximal depression adjacent to the radiopalmar ridge,accompanied by arterial hemodynamic perfusion signals into adjacent osseous interfaces.Microdissection findings revealed perforating branches of the radial artery traversing the cortical bone interface within the Lieque(LU7)acupoint region.Acupuncture stimulation at the proximal depression adjacent to the radiopalmar ridge elicited consistent acupoint sensations in all 10 participants,and the acupoint sensations differed from those of other surrounding tissues.Conclusion The anatomical structure of Lieque(LU7)acupoint is located within the proximal depression adjacent to the radiopalmar ridge,characterized by the presence of"hilus of bone"structure.
5.National bloodstream infection bacterial resistance surveillance report 2023: Gram-positive bacteria
Chaoqun YING ; Jinru JI ; Zhiying LIU ; Qing YANG ; Haishen KONG ; Jiangqin SONG ; Hui DING ; Yanyan LI ; Yuanyuan DAI ; Haifeng MAO ; Pengpeng TIAN ; Lu WANG ; Yongyun LIU ; Yizheng ZHOU ; Jiliang WANG ; Yan JIN ; Donghong HUANG ; Hongyun XU ; Peng ZHANG ; Xinhua QIANG ; Hong HE ; Lin ZHENG ; Junmin CAO ; Zhou LIU ; Ying HUANG ; Yan GENG ; Haiquan KANG ; Dan LIU ; Guolin LIAO ; Lixia ZHANG ; Fenghong CHEN ; Yanhong LI ; Baohua ZHANG ; Haixin DONG ; Xiaoyan LI ; Donghua LIU ; Qiuying ZHANG ; Xuefei HU ; Liang GUO ; Sijin MAN ; Dijing SONG ; Rong XU ; Youdong YIN ; Kunpeng LIANG ; Aiyun LI ; Zhuo LI ; Hongxia HU ; Guoping LU ; Jinhua LIANG ; Qiang LIU ; Yinqiao DONG ; Jilu SHEN ; Shuyan HU ; Liang LUAN ; Jian LI ; Ling MENG ; Dengyan QIAO ; Xiusan XIA ; Bo QUAN ; Dahong WANG ; Chunhua HAN ; Xiaoping YAN ; Fei LI ; Shifu WANG ; Ping SHEN ; Yunbo CHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2025;18(2):118-132
Objective:To report the nationwide surveillance results of pathogenic profiles and antimicrobial resistance patterns of Gram-positive bloodstream infections in China in 2023.Methods:The clinical isolates of Gram-posttive bacteria from blood cultures were collected in member hospitals of National Bloodstream Infection Bacterial Resistant Investigation Collaborative System(BRICS)during January to December 2023. Antimicrobial susceptibility testing was performed using the dilution method recommended by the Clinical and Laboratory Standards Institute(CLSI). Statistical analyses were conducted using WHONET 5.6 and SPSS 25.0 software.Results:A total of 4 385 Gram-positive bacterial isolates were obtained from 60 participating center. The top five pathogens were Staphylococcus aureus( n=1 544,35.2%),coagulase-negative Staphylococci( n=1 441,32.9%), Enterococcus faecium( n=574,13.1%), Enterococcus faecalis( n=385,8.8%),and α-hemolytic Streptococci( n=187,4.3%). The prevalence of methicillin-resistant Staphylococcus aureus(MRSA)and methicillin-resistant coagulase-negative Staphylococci(MRCNS)was 26.2%(405/1 544)and 69.8%(1 006/1 441),respectively. Notably,all Staphylococci remained susceptible to glycopeptide or daptomycin. Staphylococcus aureus demonstrated excellent susceptibility(>97.0%)to cephalobiol,rifampicin,trimethoprim-sulfamethoxazole,linezolid,minocycline,tigecycline,and eravacycline. No Enterococcus exhibiting resistance to linezolid were detected. Glycopeptide resistance was uncommon but more frequent in Enterococcus faecium(resistance to vancomycin and teicoplanin:both 1.7%)compared to Enterococcus faecalis(both 0.3%). The detection rates of MRSA and MRCNS exhibited significant regional variations across the country( χ2=17.674 and 148.650,respectively,both P<0.001). No vancomycin-resistant Enterococci were detected in central China. Institutional comparison demonstrated higher prevalence of MRSA( χ2=14.111, P<0.001)and MRCNS( χ2=4.828, P=0.028)in provincial hospitals than that in municipal hospitals. Socioeconomic analysis identified elevated detection rates of both MRSA( χ2=18.986, P<0.001)and MRCNS( χ2=4.477, P=0.034)in less developed regions(per capita GDP
6.National bloodstream infection bacterial resistance surveillance report (2023) : Gram-negative bacteria
Jinru JI ; Zhiying LIU ; Chaoqun YING ; Qing YANG ; Haishen KONG ; Jiangqin SONG ; Hui DING ; Yanyan LI ; Yuanyuan DAI ; Haifeng MAO ; Pengpeng TIAN ; Lu WANG ; Yongyun LIU ; Yizheng ZHOU ; Jiliang WANG ; Yan JIN ; Donghong HUANG ; Hongyun XU ; Peng ZHANG ; Xinhua QIANG ; Hong HE ; Lin ZHENG ; Junmin CAO ; Zhou LIU ; Ying HUANG ; Yan GENG ; Haiquan KANG ; Dan LIU ; Guolin LIAO ; Lixia ZHANG ; Fenghong CHEN ; Yanhong LI ; Baohua ZHANG ; Haixin DONG ; Xiaoyan LI ; Donghua LIU ; Qiuying ZHANG ; Xuefei HU ; Liang GUO ; Sijin MAN ; Dijing SONG ; Rong XU ; Youdong YIN ; Kunpeng LIANG ; Aiyun LI ; Zhuo LI ; Hongxia HU ; Guoping LU ; Jinhua LIANG ; Qiang LIU ; Yinqiao DONG ; Jilu SHEN ; Shuyan HU ; Liang LUAN ; Jian LI ; Ling MENG ; Dengyan QIAO ; Xiusan XIA ; Bo QUAN ; Dahong WANG ; Chunhua HAN ; Xiaoping YAN ; Fei LI ; Shifu WANG ; Ping SHEN ; Yunbo CHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2025;18(1):47-62
Objective:To report the results of bacterial resistant investigation collaborative system(BRICS)on the distribution and antimicrobial resistance profile of clinical Gram-negative bacteria isolates from bloodstream infections in China in 2023,and provide reference for clinical tretment of bloodstream infections and prevention and control of bacterial resistance.Methods:The clinical isolates of Gram-negative bacteria from blood cultures in member hospitals of BRICS were collected during January 2023 to December 2023. Antibiotic susceptibility tests were conducted by agar dilution or broth dilution methods recommended by Clinical and Laboratory Standards Institute(CLSI). WHONET 5.6 and SPSS 25.0 were used to analyze the data.Results:During the study period,11 492 strains of Gram-negative bacteria were collected from 60 hospitals,of which 10 098(87.9%)were Enterobacterales and 1 394(12.1%)were non-fermentative bacteria. The top 5 bacterial species were Escherichia coli(50.0%), Klebsiella pneumoniae(26.1%), Pseudomonas aeruginosa(5.1%), Acinetobacter baumannii complex(5.0%)and Enterobacter cloacae complex(4.1%). The ESBL-producing rates in Escherichia coli, Klebsiella pneumoniae and Proteus mirablilis were 46.8%(2 685/5 741),18.3%(549/2 999)and 44.0%(77/175),respectively. The prevalence of carbapenem-resistant Escherichia coli(CREC)and carbapenem-resistant Klebsiella pneumoniae(CRKP)were 1.3%(76/5 741)and 15.0%(450/2 999);32.9%(25/76)and 78.0%(351/450)of CREC and CRKP were sensitive to ceftazidime/avibactam combination,respectively. 94.7%(72/76)and 90.2%(406/450)of CREC and CRKP were sensitive to aztreonam/avibactam combination. Furthermore,57.9%(44/76)and 79.1%(356/450)were sensitive to imipenem/relebactam combination. The prevalence of carbapenem-resistant Acinetobacter baumannii(CRAB)complex was 64.6%(370/573),while more than 80.0% of CRAB complex was sensitive to tigecycline,eravacycline and polymyxin B. The prevalence of carbapenem-resistant Pseudomonas aeruginosa(CRPA)was 17.0%(99/581). There were differences in the composition ratio of Gram-negative bacteria in bloodstream infections and the prevalence of important Gram-negative bacteria resistance among different regions in China,with statistically significant differences in the prevalence of CREC,CRKP,CRPA and CRAB complex( χ2=10.6,28.6,10.8 and 19.3, P<0.05). The prevalence of ESBL-producing Escherichia coli, CREC,CRAB complex and CRKP were higher in provincial hospitals than those in municipal hospitals( χ2=12.5,9.8,12.7 and 57.8,all P<0.01). Conclusions:Gram-negative bacteria are the main pathogens causing bloodstream infections in China,and Escherichia coli is ranked in the top,while the trend of Klebsiella pneumoniae increases continuously with time. CRKP infection shows a slow upward trend,CREC infecton maintains a low prevalence level,and CRAB complex infection continues to exhibit a high prevalence rate. The composition and resistance patterns of pathogens causing bloodstream infections vary to some extent across different regions and levels of hospitals in China.
7.Predictive value of stress myocardial perfusion imaging with gated SPECT for cardiac death in patients with chronic kidney disease
Ying ZHANG ; Jian JIAO ; Zhi CHANG ; Xu HAN ; Quan LI ; Junqi LI ; Yehong ZHANG ; Xiaofen XIE ; Wei DONG ; Hongzhi MI
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(6):346-351
Objective:To evaluate the clinical predictive value of SPECT myocardial perfusion imaging (MPI) in the occurrence of cardiac death in patients with chronic kidney disease (CKD).Methods:A retrospective follow-up was performed for 160 patients (109 males, 51 females; age: 68.5(61.0, 74.0) years) who underwent MPI in Beijing Anzhen Hospital, Capital Medical University between June 2017 and March 2024. The 17-segment 5-point method was used for image analysis to obtain the left ventricular myocardial perfusion and functional parameters. The patients were followed up for cardiac death, and divided into death group and survival group. Clinical data of those 2 groups were compare by χ2 test, the independent-sample t test or Mann-Whitney U test. Cox proportional hazards regression analysis was used to analyze the predictors related to cardiac death. The ROC curve was used to analyze the performance of predictors. Survival curves were obtained by the Kaplan-Meier method, and log-rank test was performed to compare the difference between 2 groups. Results:The follow-up time of 160 patients with CKD was 26.0(10.0, 46.5) months. Of 160 patients, 17 died and 143 survived. There were statistically significant differences in body mass index (BMI), previous myocardial infarction, previous revascularization, hypersensitive C-reactive protein (hs-CRP), positive MPI, left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) between the death group and the survival group ( χ2 values: 4.58-16.13, t values: -2.34, -3.97, Z values: from -2.81 to 5.02, all P<0.05). Multivariate Cox regression analysis showed that SSS (hazard ratio ( HR)=1.153, 95% CI: 1.062-1.252, P=0.001) and hs-CRP ( HR=1.031, 95% CI: 1.004-1.058, P=0.023) were independent risk factors for cardiac death in patients with CKD. The optimal cut-off value of SSS for predicting cardiac death in those patients was determined to be 8 with the AUC of 0.815, and the incidence of cardiac death in the SSS ≥8 group was significantly higher than that in the SSS<8 group (33.3%(12/36) vs 4.0%(5/124); χ2 = 25.44, P<0.001). Conclusion:MPI is an important imaging method for the evaluation of cardiac death in patients with CKD, SSS and hs-CRP are important risk factors in predicting cardiac death in those patients.
8.Research on the physical anatomical structure of the Lieque(LU7)acupoint
Chunlin WANG ; Zhaoyu SHU ; Shuai ZHANG ; Quan HAN ; Peigang FANG ; Hengtao QI ; Tiezheng WANG ; Ziyu KANG ; Wenxu ZHANG ; Linjiang WANG ; Qiang WANG ; Likun DONG ; Tao WANG ; Zengtao WANG
Journal of Beijing University of Traditional Chinese Medicine 2025;48(7):992-999
Objective To investigate the anatomical structure and surface location of the Lieque(LU7)acupoint.Methods Firstly,the anatomical localization descriptions of the Lieque(LU7)acupoint from classical medical literature were reviewed and summarized.A total of 21 participants were recruited from Shandong Provincial Hospital Affiliated to Shandong First Medical University from January to March 2025.A Cartesian coordinate system was established over the Lieque(LU7)region on the right forearm.Following standardized manual pressure stimulation,the coordinates of the participant′s reported acupoint sensations were recorded.Based on surface pressure mapping result,10 participants were arbitrarily selected for acupuncture intervention.Upon elicitation of acupoint sensation,the ultrasound imaging was used for real-time visualization of anatomical spatial relationships between the needle tip and distal radial osseous landmarks.Five red latex-perfused adult upper limb specimens were selected for microdissection of the Lieque(LU7)regions pre-localized via ultrasonography,achieving definitive structural characterization of its anatomical strata.Another 10 participants were arbitrarily selected to find the physical structure of the Lieque(LU7)acupoint using ultrasound,and the similarities and differences of acupoint sensation responses were verified using acupuncture needle insertions into both the demarcated zone and peripheral tissues.Results The descriptions of the localization of the Lieque(LU7)acupoint in ancient books can be summarized as"one and a half cun above the wrist side"longitudinally,and"at the intersection head,between two tendons and two bones in the hollow"transversely.During surface pressure application,the sites of the participant′s elicited acupoint sensation were anatomically concentrated in the proximal depression adjacent to the radiopalmar ridge,specifically at the transitional interface between the extensor pollicis brevis tendon and scaphoid bone.During acupuncture-induced acupoint sensation,ultrasound imaging demonstrated that the location of the needle tip was located within the proximal depression adjacent to the radiopalmar ridge,accompanied by arterial hemodynamic perfusion signals into adjacent osseous interfaces.Microdissection findings revealed perforating branches of the radial artery traversing the cortical bone interface within the Lieque(LU7)acupoint region.Acupuncture stimulation at the proximal depression adjacent to the radiopalmar ridge elicited consistent acupoint sensations in all 10 participants,and the acupoint sensations differed from those of other surrounding tissues.Conclusion The anatomical structure of Lieque(LU7)acupoint is located within the proximal depression adjacent to the radiopalmar ridge,characterized by the presence of"hilus of bone"structure.
9.Predictive value of stress myocardial perfusion imaging with gated SPECT for cardiac death in patients with chronic kidney disease
Ying ZHANG ; Jian JIAO ; Zhi CHANG ; Xu HAN ; Quan LI ; Junqi LI ; Yehong ZHANG ; Xiaofen XIE ; Wei DONG ; Hongzhi MI
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(6):346-351
Objective:To evaluate the clinical predictive value of SPECT myocardial perfusion imaging (MPI) in the occurrence of cardiac death in patients with chronic kidney disease (CKD).Methods:A retrospective follow-up was performed for 160 patients (109 males, 51 females; age: 68.5(61.0, 74.0) years) who underwent MPI in Beijing Anzhen Hospital, Capital Medical University between June 2017 and March 2024. The 17-segment 5-point method was used for image analysis to obtain the left ventricular myocardial perfusion and functional parameters. The patients were followed up for cardiac death, and divided into death group and survival group. Clinical data of those 2 groups were compare by χ2 test, the independent-sample t test or Mann-Whitney U test. Cox proportional hazards regression analysis was used to analyze the predictors related to cardiac death. The ROC curve was used to analyze the performance of predictors. Survival curves were obtained by the Kaplan-Meier method, and log-rank test was performed to compare the difference between 2 groups. Results:The follow-up time of 160 patients with CKD was 26.0(10.0, 46.5) months. Of 160 patients, 17 died and 143 survived. There were statistically significant differences in body mass index (BMI), previous myocardial infarction, previous revascularization, hypersensitive C-reactive protein (hs-CRP), positive MPI, left ventricular end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) between the death group and the survival group ( χ2 values: 4.58-16.13, t values: -2.34, -3.97, Z values: from -2.81 to 5.02, all P<0.05). Multivariate Cox regression analysis showed that SSS (hazard ratio ( HR)=1.153, 95% CI: 1.062-1.252, P=0.001) and hs-CRP ( HR=1.031, 95% CI: 1.004-1.058, P=0.023) were independent risk factors for cardiac death in patients with CKD. The optimal cut-off value of SSS for predicting cardiac death in those patients was determined to be 8 with the AUC of 0.815, and the incidence of cardiac death in the SSS ≥8 group was significantly higher than that in the SSS<8 group (33.3%(12/36) vs 4.0%(5/124); χ2 = 25.44, P<0.001). Conclusion:MPI is an important imaging method for the evaluation of cardiac death in patients with CKD, SSS and hs-CRP are important risk factors in predicting cardiac death in those patients.
10.Application review of wearable devices in auxiliary detection and diagnosis of acute mountain sickness
Hui-quan WANG ; Shuai MA ; Guo-sheng CHEN ; Yu GUO ; Jin-han YU ; Zheng-xu YAN ; Ming-hu LIU ; Xin-min DONG
Chinese Medical Equipment Journal 2025;46(9):100-107
The pathological mechanisms and related physiological indicators of acute mountain sickness(AMS)were introduced,and the present situation of wearable devices applied in AMS auxiliary detection and diagnosis were reviewed.The challenges and future development directions of wearable devices applied in auxiliary detection and diagnosis were pointed out.[Chinese Medical Equipment Journal,2025,46(9):100-107]

Result Analysis
Print
Save
E-mail