1.Comparison of anti-VEGF treatment at different preoperative time points on retinal neovascularization in PDR
Ruolan LING ; Xi WANG ; Yue HAN ; Yawen QIN ; Jie ZHONG ; Jie LI
International Eye Science 2026;26(5):856-861
AIM:To evaluate the optimal timing of preoperative intravitreal anti vascular endothelial growth factor(VEGF)therapy in proliferative diabetic retinopathy(PDR)using intraoperative fluorescein angiography(IOFA).METHODS:A retrospective case series study was conducted on patients who underwent vitrectomy for PDR with vitreous hemorrhage(VH)at Sichuan Provincial People's Hospital from January 2023 to February 2025. Patients were divided into three groups according to the interval between intravitreal conbercept injection and surgery: Group A(3 d before surgery), Group B(7 d before surgery), and Group C(14 d before surgery). IOFA was used to assess the number and size of retinal neovascularization(NV). Additional data were collected including preoperative best corrected visual acuity(BCVA), vitreous hemorrhage grading, operative time, frequency of intraoperative endodiathermy, duration of high perfusion pressure, vitreoretinal adhesion grade, postoperative BCVA, and central macular thickness(CMT). Multidimensional analyses were performed.RESULTS:This study enrolled a total of 91 patients(94 eyes)with PDR accompanied by vitreous hemorrhage. Among them, Group A consisted of 31 patients(31 eyes; 18 males, 13 females; mean age 53.26±12.38 y), Group B consisted of 34 patients(37 eyes; 21 males, 13 females; mean age 51.61±14.16 y), and Group C consisted of 26 patients(26 eyes; 18 males, 8 females; mean age 51.00±12.02 y), with baseline characteristics comparable among the three groups(all P>0.05). Comparative analysis of NV visualized via IOFA revealed that both the number and size of NVs were significantly lower in Groups B and C than in Group A(all P<0.0167), while no statistically significant differences were observed between Groups B and C(both P>0.05). No significant differences were found among the three groups regarding other intraoperative parameters, including operation time, frequency of electrocoagulation application, duration of high perfusion pressure, or grading of vitreoretinal adhesion(all P>0.05).CONCLUSION:IOFA confirms that preoperative anti-VEGF therapy administered 7 or 14 d before surgery is more effective than a 3 d interval in suppressing retinal NV activity in PDR patients.
2.Analysis of comparator selection strategies for pharmaceutical enterprises in the national reimbursement drug list access application
Qingwen WANG ; Qin AN ; Xiaoyan YUAN ; Yuzhi HAN ; Xi CHEN ; Hongyan WU
China Pharmacy 2026;37(8):985-990
OBJECTIVE To analyze the selection and rationales of comparators for pharmaceutical enterprises in their medical insurance access application, so as to provide a reference for promoting communication and consensus between enterprises and medical insurance authorities in this process. METHODS The application materials for drugs outside the catalogue that passed formal review published by the National Healthcare Security Administration from 2021 to 2025 were extracted, and then content analysis was used to systematically sort out relevant information of the declared drugs and comparators; the specific situations and rationales of pharmaceutical enterprises’ selection of comparators were analyzed. RESULTS A total of 1 341 declared drug documents were collected. Data analysis showed that 1 035 (77.18%) were submitted with positive comparators and 306 (22.82%) used blank comparators; 58 drugs (4.33%) took combination therapy as the reference, and 5 drugs (0.37%) referred to non-pharmacological (or non-single pharmacological) treatment regimens. Among competitive drugs declared by multiple enterprises, 50.00% of the enterprises submitted different comparators. A total of 4 basic conditions and 39 additional conditions were extracted as the rationales for selecting positive comparators. For blank comparators, 12 drug-related factors, 2 administrative factors, and 1 other factor were identified. More than 10% of the drugs did not state the rationale for comparator selection, and over 44% of drugs using blank comparators provided only one justification. CONCLUSIONS Pharmaceutical enterprises mainly select comparators based on their own interests in the medical insurance access application, and there are deficiencies in the adequacy and standardization of their selection basis and reasoning. It is recommended that enterprises follow the principled requirements of medical insurance authorities, and fully and normatively explain the reasons for selecting comparators in combination with the characteristics of their own products. Meanwhile, it is advisable to change the current open-ended statement form of selection reasons into a closed-ended answering mode, so as to highlight the priority of selection, standardize the declaration behavior of enterprises, and reduce communication divergences between the two parties.
3.Report of 4 cases of IgG4-related urinary diseases and literature review
Fanchao WEI ; Zhaoxiang WANG ; Mengwei XU ; Ruochen QI ; Guohui WANG ; Xiaoyan ZHANG ; Tong XU ; Jingliang ZHANG ; Shuaijun MA ; Weijun QIN ; Lijun YANG ; Shichao HAN
Journal of Modern Urology 2025;30(1):59-63
[Objective] To explore the clinical features of IgG4-related urinary diseases so as to provide reference for the diagnosis and treatment of such diseases. [Methods] The clinical data of 4 cases of IgG4-related urinary system diseases diagnosed and treated in Xijing Hospital of Air Force Medical University during Aug.2019 and Dec.2023 were retrospectively collected.Here, we report on the diagnosis and treatment of these patients, analysing their symptoms, serology, imaging and pathology as well as their treatment and outcomes. [Results] The patients included 2 male and 2 female.The lesions were involved with the retroperitoneum and urinary system.Three patients had symptoms of lumbar pain.The imaging manifestations were complex, including retroperitoneal mass involving urinary system organs in 2 cases, tabdense shadow of the right kidney in 1 case, and simple cystic mass of kidney in 1 case.Serum IgG4 value was not detected before surgery.All patients underwent radical surgical treatment.Postoperative pathology showed fibrous tissue hyperplasia with a large number of plasma cells, lymphocytes, a few neutrophil infiltrates, and lymphoid follicles and obliterated vasculitis in some specimens.The number of IgG4+ plasma cells was more than 10 in all tissues under high power microscope.After surgery, 3 patients had symptoms improved, and serum IgG4 value was within the normal range; 1 patient (patem 3) had elevated IgG4 value during follow-up, received subsequent hormone therapy, and the serum IgG 4 level remained stable. [Conclusion] The symptoms of IgG4-related diseases involving the urinary system are non-specific, and the imaging findings are various, easily confused with other diseases.Early detection of serum IgG4 and biopsy pathology can help clinicians make correct diagnosis in the early stage.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Detection and trends of HIVAIDS cases in medical institutions in China from 2017 to 2023
LIANG Fuxin ; WANG Shaorong ; QIN Qianqian ; LI Hui ; HAN Jing ; XU Jie
China Tropical Medicine 2025;25(3):358-
Objective To analyse the crude detection rate and trends of newly detected HIV/AIDS cases in medical institutions in China from 2017 to 2023, and to provide a reference for optimizing HIV testing strategies in medical institutions. Methods Data on HIV testing and newly reported HIV/AIDS cases were analysed using data from the Comprehensive AIDS Prevention and Control Information System of the China Information System for Disease Control and Prevention for the period from 2017 to 2023. HIV testing in medical institutions includes patients tested preoperatively, those tested before transfusion, those tested in sexually transmitted disease (STD) clinics, prenatal care clinics, and other types of patients. Descriptive statistical analysis and χ2 test were performed using SAS 9.4 software. Joinpoint regression was performed using Joinpoint 4.9.0 software to analyse trends of the crude detection rates over time. Results From 2017 to 2023, the person-times of HIV tests in medical institutions increased from 143 million to 255 million, with an increase of 78.07%. The number of newly detected HIV/AIDS cases increased from 74 000 to 88 000 and then declined to 69 000. The crude detection rate of new HIV/AIDS cases declined from 5.18/10 000 to 2.71/10 000, showed a declining trend, the mean annual percentage change was -9.99%(P<0.001). The crude detection rate of new HIV/AIDS cases in STD clinics was the highest among all types of clinic visits (12.79/10 000-24.47/10 000), and the crude detection rate of new cases among all types of clinic visits showed a decreasing trend(P<0.05). Among different medical institutions, general hospitals were the most important source of the number of tests and the number of newly detected HIV/AIDS cases, accounting for more than 62.93% and 62.68%, respectively. Specialised medical institutions had the highest crude detection rate of new cases, which was maintained at more than 5.13/10 000. The crude detection rate of new cases for all four types of medical institutions, except for primary medical institutions, showed a decreasing trend (P<0.05). Conclusions The detection rate of new cases in medical institutions showed a decreasing trend in 2017-2023, and the efficiency of STD clinics testing and detection was higher among all types of attendees. General hospitals are the main source of new cases detection, and testing in specialised medical institutions is more efficient. Testing should be strengthened in key groups of patients and in key medical institutions.
9.Update on the treatment navigation for functional cure of chronic hepatitis B: Expert consensus 2.0
Di WU ; Jia-Horng KAO ; Teerha PIRATVISUTH ; Xiaojing WANG ; Patrick T.F. KENNEDY ; Motoyuki OTSUKA ; Sang Hoon AHN ; Yasuhito TANAKA ; Guiqiang WANG ; Zhenghong YUAN ; Wenhui LI ; Young-Suk LIM ; Junqi NIU ; Fengmin LU ; Wenhong ZHANG ; Zhiliang GAO ; Apichat KAEWDECH ; Meifang HAN ; Weiming YAN ; Hong REN ; Peng HU ; Sainan SHU ; Paul Yien KWO ; Fu-sheng WANG ; Man-Fung YUEN ; Qin NING
Clinical and Molecular Hepatology 2025;31(Suppl):S134-S164
As new evidence emerges, treatment strategies toward the functional cure of chronic hepatitis B are evolving. In 2019, a panel of national hepatologists published a Consensus Statement on the functional cure of chronic hepatitis B. Currently, an international group of hepatologists has been assembled to evaluate research since the publication of the original consensus, and to collaboratively develop the updated statements. The 2.0 Consensus was aimed to update the original consensus with the latest available studies, and provide a comprehensive overview of the current relevant scientific literatures regarding functional cure of hepatitis B, with a particular focus on issues that are not yet fully clarified. These cover the definition of functional cure of hepatitis B, its mechanisms and barriers, the effective strategies and treatment roadmap to achieve this endpoint, in particular new surrogate biomarkers used to measure efficacy or to predict response, and the appropriate approach to pursuing a functional cure in special populations, the development of emerging antivirals and immunomodulators with potential for curing hepatitis B. The statements are primarily intended to offer international guidance for clinicians in their practice to enhance the functional cure rate of chronic hepatitis B.
10.Update on the treatment navigation for functional cure of chronic hepatitis B: Expert consensus 2.0
Di WU ; Jia-Horng KAO ; Teerha PIRATVISUTH ; Xiaojing WANG ; Patrick T.F. KENNEDY ; Motoyuki OTSUKA ; Sang Hoon AHN ; Yasuhito TANAKA ; Guiqiang WANG ; Zhenghong YUAN ; Wenhui LI ; Young-Suk LIM ; Junqi NIU ; Fengmin LU ; Wenhong ZHANG ; Zhiliang GAO ; Apichat KAEWDECH ; Meifang HAN ; Weiming YAN ; Hong REN ; Peng HU ; Sainan SHU ; Paul Yien KWO ; Fu-sheng WANG ; Man-Fung YUEN ; Qin NING
Clinical and Molecular Hepatology 2025;31(Suppl):S134-S164
As new evidence emerges, treatment strategies toward the functional cure of chronic hepatitis B are evolving. In 2019, a panel of national hepatologists published a Consensus Statement on the functional cure of chronic hepatitis B. Currently, an international group of hepatologists has been assembled to evaluate research since the publication of the original consensus, and to collaboratively develop the updated statements. The 2.0 Consensus was aimed to update the original consensus with the latest available studies, and provide a comprehensive overview of the current relevant scientific literatures regarding functional cure of hepatitis B, with a particular focus on issues that are not yet fully clarified. These cover the definition of functional cure of hepatitis B, its mechanisms and barriers, the effective strategies and treatment roadmap to achieve this endpoint, in particular new surrogate biomarkers used to measure efficacy or to predict response, and the appropriate approach to pursuing a functional cure in special populations, the development of emerging antivirals and immunomodulators with potential for curing hepatitis B. The statements are primarily intended to offer international guidance for clinicians in their practice to enhance the functional cure rate of chronic hepatitis B.

Result Analysis
Print
Save
E-mail