1.Construction and application of a system for rational drug use for prescriptions from internet hospitals and external prescriptions and medical insurance fund control based on a pre-review prescription system
Yi GE ; Xiaolan WANG ; Junping HAN ; Bo LYU ; Yu GUAN ; Feng XU ; Aiming SHI
China Pharmacy 2026;37(5):584-588
OBJECTIVE To ensure the safety of patients’ drug use and control the risk of medical insurance expenditure by upgrading the pre-prescription review system to conduct pre-review on prescriptions from internet hospitals and external prescriptions, as well as to review the payment methods of drugs (including in-hospital and external drug dispensing). METHODS The data interfaces of prescriptions from internet hospitals and external prescriptions were integrated to achieve real-time rational drug use intervention. Additionally, an intelligent review project for payment method was added to precisely intervene in the medical insurance payment methods of drugs. The effect of the system upgrade was evaluated by comparing the qualification rates of prescriptions from internet hospitals and external prescriptions and the suspected amounts of drug violations from January to April 2025 (before the system upgrade) and May to August 2025 (after the system upgrade). RESULTS After the upgrade of the pre-prescription review system, the qualification rates of prescriptions from internet hospitals and external prescriptions increased by 3.5% [95% confidence interval (CI)=0.3%-6.7%, P =0.037 ] ; the suspected amounts of drug violations decreased to 52.9% of the pre-upgrade level (95%CI=31.6%-88.5%, P =0.026), and the average monthly sequential decrease was 29.5% (95%CI=12.2%-43.4%, P =0.012). Moreover, the addition of the intelligent review project for payment methods promoted the management of off-label drug use in our hospital. After the upgrade, a total of 79 filling valid applications for off-label drug use were received and archived. CONCLUSIONS The upgrade of the pre-prescription review system effectively improves the review qualification rates of prescriptions from internet hospitals and external prescriptions and the accuracy of medical insurance payment for drugs, and strengthens the supervision of off-label drug use, achieving dual guarantees of clinical rationality and medical insurance compliance.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Five new triterpenoid saponins from the kernels of Momordica cochinchinensis
Ru DING ; Jia-qi WANG ; Yi-yang LUO ; Yong-long HAN ; Xiao-bo LI ; Meng-yue WANG
Acta Pharmaceutica Sinica 2025;60(2):442-448
Five saponins were isolated from the kernels of
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.The Invariant Neural Representation of Neurons in Pigeon’s Ventrolateral Mesopallium to Stereoscopic Shadow Shapes
Xiao-Ke NIU ; Meng-Bo ZHANG ; Yan-Yan PENG ; Yong-Hao HAN ; Qing-Yu WANG ; Yi-Xin DENG ; Zhi-Hui LI
Progress in Biochemistry and Biophysics 2025;52(10):2614-2626
ObjectiveIn nature, objects cast shadows due to illumination, forming the basis for stereoscopic perception. Birds need to adapt to changes in lighting (meaning they can recognize stereoscopic shapes even when shadows look different) to accurately perceive different three-dimensional forms. However, how neurons in the key visual brain area in birds handle these lighting changes remains largely unreported. In this study, pigeons (Columba livia) were used as subjects to investigate how neurons in pigeon’s ventrolateral mesopallium (MVL) represent stereoscopic shapes consistently, regardless of changes in lighting. MethodsVisual cognitive training combined with neuronal recording was employed. Pigeons were first trained to discriminate different stereoscopic shapes (concave/convex). We then tested whether and how light luminance angle and surface appearance of the stereoscopic shapes affect their recognition accuracy, and further verify whether the results rely on specify luminance color. Simultaneously, neuronal firing activity of neurons was recorded with multiple electrode array implanted from the MVL during the presentation of difference shapes. The response was finally analyzed how selectively they responded to different stereoscopic shapes and whether their selectivity was affected by the changes of luminance condition (like lighting angle) or surface look. Support vector machine (SVM) models were trained on neuronal population responses recorded under one condition (light luminance angle of 45°) and used to decode responses under other conditions (light luminance angle of 135°, 225°, 315°) to verify the invariance of responses to different luminance conditions. ResultsBehavioral results from 6 pigeons consistently showed that the pigeons could reliably identify the core 3D shape (over 80% accuracy), and this ability wasn’t affected by changes in light angle or surface appearance. Statistical analysis of 88 recorded neurons from 6 pigeons revealed that 83% (73/88) showed strong selectivity for specific 3D shapes (selectivity index>0.3), and responses to convex shapes were consistently stronger than to concave shapes. These shape-selective responses remained stable across changes in light angle and surface appearance. Neural patterns were consistent under both blue and orange lighting. The decoding accuracy achieves above 70%, suggesting stable responses under different conditions (e.g., different lighting angles or surface appearance). ConclusionNeurons in the pigeon MVL maintain a consistent neural encoding pattern for different stereoscopic shapes, unaffected by illumination or surface appearance. This ensures stable object recognition by pigeons in changing visual environments. Our findings provide new physiological evidence for understanding how birds achieve stable perception (“invariant neural representations”) while coping with variations in the visual field.
9.Misaligned light entrainment causes metabolic disorders in Chrono knockout mice.
Ruo-Han WANG ; Shao-Ying LAN ; Bo-Yuan CAO ; Xi-Ming QIN
Acta Physiologica Sinica 2025;77(4):731-740
Most of the life forms on Earth have gradually evolved an endogenous biological clock under the long-term influence of periodic daily light-dark cycles. This biological clock system plays a crucial role in the orderly progression of life activities. In mammals, central circadian clock is located in the suprachiasmatic nucleus of the hypothalamus and the function of the biological clock relies on a transcription-translation negative feedback loop. As a negative regulator in this loop, the function of CHRONO is less known. To deeply explore the role of the Chrono gene in rhythm entrainment and physiology, we constructed a Chrono gene knockout mouse strain using the CRISPR/Cas9 technology and analyzed its entrainment ability under different T cycles. Running wheel tests and glucose tolerance tests were also performed. The results showed that the period of the endogenous biological clock of Chrono knockout mice was prolonged, and the entrainment rate under the T21 cycle was decreased. In addition, metabolic abnormalities, including weight gain and impaired glucose tolerance, were observed in the non-entrained mice. Overall, this study reveals a crucial role of the Chrono gene in maintaining circadian rhythms and metabolic balance, providing a new perspective for understanding the relationship between the biological clock and metabolism. Further research is needed to fully understand the underlying molecular mechanisms.
Animals
;
Mice, Knockout
;
Mice
;
Circadian Rhythm/genetics*
;
Metabolic Diseases/physiopathology*
;
Photoperiod
;
Male
;
Period Circadian Proteins/physiology*
;
Light
;
Circadian Clocks/physiology*
10.Outcome indicators in randomized controlled trials of traditional Chinese medicine treatment of post-stroke depression.
Jin HAN ; Yue YUAN ; Fang-Biao XU ; Yan-Bo SONG ; Yong-Kang SUN ; Xin-Zhi WANG
China Journal of Chinese Materia Medica 2025;50(2):542-559
This study systematically reviewed the randomized controlled trial(RCT) of traditional Chinese medicine(TCM) treatment of post-stroke depression(PSD) and analyzed the clinical study characteristics and outcome indicators, aiming to optimize the design and establish the core outcome set in the future clinical trials of the TCM treatment of PSD. PubMed, Web of Science, Cochrane Library, EMbase, CNKI, VIP, Wanfang, and SinoMed were searched for the relevant RCT published in recent 3 years. The basic characteristics, intervention measures, and outcome indicators of the included RCT were extracted, and the descriptive analysis was carried out. A total of 76 RCTs were eventually included, with the sample size concentrated in 80-100 cases. The most frequent TCM syndromes were liver depression and Qi stagnation(15 times, 31.91%) and phlegm combined with stasis(5 times, 10.63%). The frequency of intervention methods followed a descending trend of TCM decoction(35 times, 46.05%) and TCM decoction + acupuncture(4 times, 5.26%), Chinese patent medicine(3 times, 3.94%), and the intervention mainly lasted for 1 to 3 months(43 times, 60.56%). The adverse reactions of patients were mainly digestive system reaction(150 patients, 39.37%) and nervous system reaction(112 patients, 29.39%). Most of the included studies had unclear risk of bias, involving 84 outcome indicators, which belonged to 8 indicator domains. The RCTs of TCM treatment of PSD showed a variety of problems, such as non-standard TCM syndrome differentiation, inconsistent names of TCM syndrome scores and measurement tools, low quality, unclear risk of bias, neglect of endpoint indicators, unreasonable selection of substitute indicators, lack of differentiation between primary and secondary outcome indicators, non-standard reporting of safety indicators, insufficient attention to economic indicators, and lack of long-term prognosis evaluation. It is suggested that the future research should improve the quality of methodology and build a standardized core outcome set to promote the development of high-quality clinical research in this field.
Humans
;
Randomized Controlled Trials as Topic
;
Drugs, Chinese Herbal/administration & dosage*
;
Stroke/psychology*
;
Depression/etiology*
;
Treatment Outcome
;
Medicine, Chinese Traditional

Result Analysis
Print
Save
E-mail