1.Comparing Outcomes between Cage Alone and Plate Fixation in Single-Level Anterior Cervical Fusion: A Retrospective Clinical Series
Jae-Won SHIN ; Han-Bin JIN ; Yung PARK ; Joong-Won HA ; Hak-Sun KIM ; Kyung-Soo SUK ; Sung-Hwan MOON ; Si-Young PARK ; Byung-Ho LEE ; Ji-Won KWON ; In-Uk KIM
Clinics in Orthopedic Surgery 2025;17(3):417-426
Background:
To identify the optimal surgical technique for single-level anterior cervical discectomy and fusion (ACDF), this study compared surgical outcomes and incidence of adjacent segment degeneration (ASD) in patients undergoing single-level ACDF using cage alone single-level fusion and plate fixation techniques.
Methods:
This single-center retrospective study (2003–2018) included patients who underwent single-level ACDF with either plate fixation (PLATE) or cage (CAGE) alone. The radiologic and clinical outcomes between the 2 surgical groups were compared over a 4-year follow-up period. Outcomes of interest included parameters related to range of motion, sagittal alignment, as well as fusion, subsidence, and ASD rates. Clinical outcomes were evaluated using the Neck Disability Index (NDI) and visual analog scale (VAS) for pain. Dysphagia and hoarseness rates were estimated based on medical records.
Results:
Forty-seven patients were included (n=17 in CAGE group). In the CAGE group, 94.1% of the patients had Bridwell grade 1 or 2, compared to 83.3% in the PLATE group (p = 0.396). Subsidence occurred in 12.5% and 3.6% of the CAGE and PLATE cases, respectively (p = 0.543). Segmental kyphosis progressed in the CAGE group compared to the PLATE group at 12, 24, and 48 months (p < 0.001). Radiographic ASD was observed in 41.2% and 30.0% of patients in the CAGE and PLATE groups, respectively, with a higher incidence in the upper segments for both groups. Preoperative NDI scores were similar between the groups; however, postoperatively, the CAGE group had significantly lower NDI scores (3.50 ± 2.74 vs. 8.00 ± 5.81) at 4 years (p = 0.020). Neck pain VAS scores also showed significant improvement in the CAGE group (2.33 ± 2.94) compared with that in the PLATE group (3.07 ± 2.31) at 4 years (p = 0.045). Both groups showed comparable arm pain VAS scores at 2 and 4 years postoperatively. Postoperative dysphagia occurred in 1 patient in the PLATE group, resolving almost completely by 1 year.
Conclusions
Single-level ACDF using a cage alone technique demonstrated favorable radiologic and clinical outcomes overall compared to plate-augmented ACDF. However, plate augmentation is recommended for patients with severe cervical kyphosis or those at high risk of subsidence.
2.Comparing Outcomes between Cage Alone and Plate Fixation in Single-Level Anterior Cervical Fusion: A Retrospective Clinical Series
Jae-Won SHIN ; Han-Bin JIN ; Yung PARK ; Joong-Won HA ; Hak-Sun KIM ; Kyung-Soo SUK ; Sung-Hwan MOON ; Si-Young PARK ; Byung-Ho LEE ; Ji-Won KWON ; In-Uk KIM
Clinics in Orthopedic Surgery 2025;17(3):417-426
Background:
To identify the optimal surgical technique for single-level anterior cervical discectomy and fusion (ACDF), this study compared surgical outcomes and incidence of adjacent segment degeneration (ASD) in patients undergoing single-level ACDF using cage alone single-level fusion and plate fixation techniques.
Methods:
This single-center retrospective study (2003–2018) included patients who underwent single-level ACDF with either plate fixation (PLATE) or cage (CAGE) alone. The radiologic and clinical outcomes between the 2 surgical groups were compared over a 4-year follow-up period. Outcomes of interest included parameters related to range of motion, sagittal alignment, as well as fusion, subsidence, and ASD rates. Clinical outcomes were evaluated using the Neck Disability Index (NDI) and visual analog scale (VAS) for pain. Dysphagia and hoarseness rates were estimated based on medical records.
Results:
Forty-seven patients were included (n=17 in CAGE group). In the CAGE group, 94.1% of the patients had Bridwell grade 1 or 2, compared to 83.3% in the PLATE group (p = 0.396). Subsidence occurred in 12.5% and 3.6% of the CAGE and PLATE cases, respectively (p = 0.543). Segmental kyphosis progressed in the CAGE group compared to the PLATE group at 12, 24, and 48 months (p < 0.001). Radiographic ASD was observed in 41.2% and 30.0% of patients in the CAGE and PLATE groups, respectively, with a higher incidence in the upper segments for both groups. Preoperative NDI scores were similar between the groups; however, postoperatively, the CAGE group had significantly lower NDI scores (3.50 ± 2.74 vs. 8.00 ± 5.81) at 4 years (p = 0.020). Neck pain VAS scores also showed significant improvement in the CAGE group (2.33 ± 2.94) compared with that in the PLATE group (3.07 ± 2.31) at 4 years (p = 0.045). Both groups showed comparable arm pain VAS scores at 2 and 4 years postoperatively. Postoperative dysphagia occurred in 1 patient in the PLATE group, resolving almost completely by 1 year.
Conclusions
Single-level ACDF using a cage alone technique demonstrated favorable radiologic and clinical outcomes overall compared to plate-augmented ACDF. However, plate augmentation is recommended for patients with severe cervical kyphosis or those at high risk of subsidence.
3.Biportal endoscopic non-facetectomy foraminal decompression and discectomy (ligamentum flavum turn-down technique)
Dae-Young LEE ; Han-Bin JIN ; Hee Soo KIM ; Jun-Bum LEE ; Si-Young PARK ; Seung-Hwan KOOK
Asian Spine Journal 2025;19(2):259-266
This study introduces a novel biportal endoscopic foraminal decompression technique that minimizes bone removal while ensuring safe and effective nerve root decompression. Leveraging the accessory process as a key surgical landmark, this technique enables precise navigation and controlled turn-down of the ligamentum flavum (LF). A key advantage of this technique is its reduced requirement for bone resection, differing from traditional microscopic or uniportal endoscopic surgeries that often necessitate resection of the lateral isthmus or superior articular process. This technique is particularly beneficial for foraminal and extraforaminal herniated nucleus pulposus cases, where bony decompression needs are relatively lower compared to foraminal stenosis. Using the accessory process as a landmark also enhances surgical precision and reduces the risk of nerve root injury, providing a valuable advantage for less experienced surgeons. Despite these advantages, challenges exist, particularly at the L5–S1 level, where the less prominent accessory process and limited workspace due to anatomical constraints can pose difficulties. In cases of severe bony compression, additional bone removal may be necessary to achieve adequate decompression. In conclusion, the Non-facetectomy LF turn-down technique (non-facetectomy foraminal decompression) offers a safe and effective minimally invasive alternative for treating various foraminal pathologies.
4.Biportal endoscopic non-facetectomy foraminal decompression and discectomy (ligamentum flavum turn-down technique)
Dae-Young LEE ; Han-Bin JIN ; Hee Soo KIM ; Jun-Bum LEE ; Si-Young PARK ; Seung-Hwan KOOK
Asian Spine Journal 2025;19(2):259-266
This study introduces a novel biportal endoscopic foraminal decompression technique that minimizes bone removal while ensuring safe and effective nerve root decompression. Leveraging the accessory process as a key surgical landmark, this technique enables precise navigation and controlled turn-down of the ligamentum flavum (LF). A key advantage of this technique is its reduced requirement for bone resection, differing from traditional microscopic or uniportal endoscopic surgeries that often necessitate resection of the lateral isthmus or superior articular process. This technique is particularly beneficial for foraminal and extraforaminal herniated nucleus pulposus cases, where bony decompression needs are relatively lower compared to foraminal stenosis. Using the accessory process as a landmark also enhances surgical precision and reduces the risk of nerve root injury, providing a valuable advantage for less experienced surgeons. Despite these advantages, challenges exist, particularly at the L5–S1 level, where the less prominent accessory process and limited workspace due to anatomical constraints can pose difficulties. In cases of severe bony compression, additional bone removal may be necessary to achieve adequate decompression. In conclusion, the Non-facetectomy LF turn-down technique (non-facetectomy foraminal decompression) offers a safe and effective minimally invasive alternative for treating various foraminal pathologies.
5.Comparing Outcomes between Cage Alone and Plate Fixation in Single-Level Anterior Cervical Fusion: A Retrospective Clinical Series
Jae-Won SHIN ; Han-Bin JIN ; Yung PARK ; Joong-Won HA ; Hak-Sun KIM ; Kyung-Soo SUK ; Sung-Hwan MOON ; Si-Young PARK ; Byung-Ho LEE ; Ji-Won KWON ; In-Uk KIM
Clinics in Orthopedic Surgery 2025;17(3):417-426
Background:
To identify the optimal surgical technique for single-level anterior cervical discectomy and fusion (ACDF), this study compared surgical outcomes and incidence of adjacent segment degeneration (ASD) in patients undergoing single-level ACDF using cage alone single-level fusion and plate fixation techniques.
Methods:
This single-center retrospective study (2003–2018) included patients who underwent single-level ACDF with either plate fixation (PLATE) or cage (CAGE) alone. The radiologic and clinical outcomes between the 2 surgical groups were compared over a 4-year follow-up period. Outcomes of interest included parameters related to range of motion, sagittal alignment, as well as fusion, subsidence, and ASD rates. Clinical outcomes were evaluated using the Neck Disability Index (NDI) and visual analog scale (VAS) for pain. Dysphagia and hoarseness rates were estimated based on medical records.
Results:
Forty-seven patients were included (n=17 in CAGE group). In the CAGE group, 94.1% of the patients had Bridwell grade 1 or 2, compared to 83.3% in the PLATE group (p = 0.396). Subsidence occurred in 12.5% and 3.6% of the CAGE and PLATE cases, respectively (p = 0.543). Segmental kyphosis progressed in the CAGE group compared to the PLATE group at 12, 24, and 48 months (p < 0.001). Radiographic ASD was observed in 41.2% and 30.0% of patients in the CAGE and PLATE groups, respectively, with a higher incidence in the upper segments for both groups. Preoperative NDI scores were similar between the groups; however, postoperatively, the CAGE group had significantly lower NDI scores (3.50 ± 2.74 vs. 8.00 ± 5.81) at 4 years (p = 0.020). Neck pain VAS scores also showed significant improvement in the CAGE group (2.33 ± 2.94) compared with that in the PLATE group (3.07 ± 2.31) at 4 years (p = 0.045). Both groups showed comparable arm pain VAS scores at 2 and 4 years postoperatively. Postoperative dysphagia occurred in 1 patient in the PLATE group, resolving almost completely by 1 year.
Conclusions
Single-level ACDF using a cage alone technique demonstrated favorable radiologic and clinical outcomes overall compared to plate-augmented ACDF. However, plate augmentation is recommended for patients with severe cervical kyphosis or those at high risk of subsidence.
6.Biportal endoscopic non-facetectomy foraminal decompression and discectomy (ligamentum flavum turn-down technique)
Dae-Young LEE ; Han-Bin JIN ; Hee Soo KIM ; Jun-Bum LEE ; Si-Young PARK ; Seung-Hwan KOOK
Asian Spine Journal 2025;19(2):259-266
This study introduces a novel biportal endoscopic foraminal decompression technique that minimizes bone removal while ensuring safe and effective nerve root decompression. Leveraging the accessory process as a key surgical landmark, this technique enables precise navigation and controlled turn-down of the ligamentum flavum (LF). A key advantage of this technique is its reduced requirement for bone resection, differing from traditional microscopic or uniportal endoscopic surgeries that often necessitate resection of the lateral isthmus or superior articular process. This technique is particularly beneficial for foraminal and extraforaminal herniated nucleus pulposus cases, where bony decompression needs are relatively lower compared to foraminal stenosis. Using the accessory process as a landmark also enhances surgical precision and reduces the risk of nerve root injury, providing a valuable advantage for less experienced surgeons. Despite these advantages, challenges exist, particularly at the L5–S1 level, where the less prominent accessory process and limited workspace due to anatomical constraints can pose difficulties. In cases of severe bony compression, additional bone removal may be necessary to achieve adequate decompression. In conclusion, the Non-facetectomy LF turn-down technique (non-facetectomy foraminal decompression) offers a safe and effective minimally invasive alternative for treating various foraminal pathologies.
7.Comparing Outcomes between Cage Alone and Plate Fixation in Single-Level Anterior Cervical Fusion: A Retrospective Clinical Series
Jae-Won SHIN ; Han-Bin JIN ; Yung PARK ; Joong-Won HA ; Hak-Sun KIM ; Kyung-Soo SUK ; Sung-Hwan MOON ; Si-Young PARK ; Byung-Ho LEE ; Ji-Won KWON ; In-Uk KIM
Clinics in Orthopedic Surgery 2025;17(3):417-426
Background:
To identify the optimal surgical technique for single-level anterior cervical discectomy and fusion (ACDF), this study compared surgical outcomes and incidence of adjacent segment degeneration (ASD) in patients undergoing single-level ACDF using cage alone single-level fusion and plate fixation techniques.
Methods:
This single-center retrospective study (2003–2018) included patients who underwent single-level ACDF with either plate fixation (PLATE) or cage (CAGE) alone. The radiologic and clinical outcomes between the 2 surgical groups were compared over a 4-year follow-up period. Outcomes of interest included parameters related to range of motion, sagittal alignment, as well as fusion, subsidence, and ASD rates. Clinical outcomes were evaluated using the Neck Disability Index (NDI) and visual analog scale (VAS) for pain. Dysphagia and hoarseness rates were estimated based on medical records.
Results:
Forty-seven patients were included (n=17 in CAGE group). In the CAGE group, 94.1% of the patients had Bridwell grade 1 or 2, compared to 83.3% in the PLATE group (p = 0.396). Subsidence occurred in 12.5% and 3.6% of the CAGE and PLATE cases, respectively (p = 0.543). Segmental kyphosis progressed in the CAGE group compared to the PLATE group at 12, 24, and 48 months (p < 0.001). Radiographic ASD was observed in 41.2% and 30.0% of patients in the CAGE and PLATE groups, respectively, with a higher incidence in the upper segments for both groups. Preoperative NDI scores were similar between the groups; however, postoperatively, the CAGE group had significantly lower NDI scores (3.50 ± 2.74 vs. 8.00 ± 5.81) at 4 years (p = 0.020). Neck pain VAS scores also showed significant improvement in the CAGE group (2.33 ± 2.94) compared with that in the PLATE group (3.07 ± 2.31) at 4 years (p = 0.045). Both groups showed comparable arm pain VAS scores at 2 and 4 years postoperatively. Postoperative dysphagia occurred in 1 patient in the PLATE group, resolving almost completely by 1 year.
Conclusions
Single-level ACDF using a cage alone technique demonstrated favorable radiologic and clinical outcomes overall compared to plate-augmented ACDF. However, plate augmentation is recommended for patients with severe cervical kyphosis or those at high risk of subsidence.
8.A Study on iPSC-Associated Factors in the Generation of Hepatocytes
Delger BAYARSAIKHAN ; Govigerel BAYARSAIKHAN ; Hyun A KANG ; Su Bin LEE ; So Hee HAN ; Teruo OKANO ; Kyungsook KIM ; Bonghee LEE
Tissue Engineering and Regenerative Medicine 2024;21(8):1245-1254
BACKGROUND:
Hepatocytes are an attractive cell source in hepatic tissue engineering because they are the primary cells of the liver, maintaining liver homeostasis through their intrinsic function. Due to the increasing demand for liver donors, a wide range of methods are being studied to obtain functionally active hepatocytes. iPSCs are one of the alternative cell sources, which shows great promise as a tool for generating hepatocytes.
METHODS:
This study determined whether factors associated with iPSCs contributed to variation in hepatocyte-like cells derived from iPSCs. The factors of concern for the iPSCs included the culture system, the source of iPSCs, and cell seeding density for initiating the differentiation.
RESULTS:
Our results found iPSC-dependent variances among differentiated hepatocyte-like cells. The matrix used in culturing iPSCs significantly impacts cell morphologies, characteristics, and the expression of pluripotent genes, such as OCT4 and SOX2, varied in iPSCs derived from different sources. These characteristics, in turn, play a consequential role in determining the functional activity of the iPSC-derived hepatocyte-like cells. In addition, cell seeding density was observed to be an essential factor for the efficient generation of iPSC-derived hepatocyte-like cells, with 2- 4 * 10 cells/cm of seeding density resulting in good morphology and functionality.
CONCLUSION
This study provides the baseline of effective differentiation protocols for iPSC-derived hepatocyte-like cells with the appropriate conditions, including cell culture media, iPSC source, and the seeding density of iPSCs.
9.Normative Parameters of Olfactory Bulbs Based on Magnetic Resonance Imaging and Olfactory Function
Minju KIM ; Ji Ye LEE ; Yong Hwy KIM ; Seung Hong CHOI ; Tae-Bin WON ; Doo Hee HAN
Journal of Korean Medical Science 2024;39(45):e321-
Background:
Olfactory dysfunction is a frequently encountered sensory disorder that increases with aging, assessed magnetic resonance imaging (MRI); however, reference quantitative values for associated anatomical structures have rarely been suggested. The aim of this study was to assess the parameters of the olfactory bulbs (OBs) and olfactory sulcus (OS) in Korean adults according to age, along with their olfactory function.
Methods:
We retrospectively evaluated 217 consecutive patients (104 men, 113 women;mean age, 52.4 ± 15.6 years) who underwent sellar MRI and olfactory function testing before transsphenoidal approach at a single tertiary center from March 2022 to December 2023. Based on the T2-weighted MRI, we evaluated the quantitative size parameters and morphological features of patients’ OB and OS, along with their olfactory function test scores. We assessed the relationship between OB volume and age in pairwise correlations.
Results:
The mean OB volume was 45.6 ± 15.3 mm 3 in all patients. The patients’ mean Korean version of the Sniffin’ Sticks (KVSS) test II score was 26.8 ± 4.1. OB volume (P < 0.001), height (P < 0.001), and anteroposterior diameter (APD) (P < 0.001) differed significantly among the different age groups. Reduced OB volume was significantly associated with aging (r = –0.58, P < 0.001) and a decline in olfactory function scores (r = 0.34, P < 0.001).
Conclusion
Based on MRI, we proposed reference OB and OS values in adults of different age groups, highlighting the reduction in OB parameters, especially height and APD along with volume associated with aging and olfactory decline. These values can be useful for evaluating adult patients undergoing MRI for olfactory dysfunction.
10.Normative Parameters of Olfactory Bulbs Based on Magnetic Resonance Imaging and Olfactory Function
Minju KIM ; Ji Ye LEE ; Yong Hwy KIM ; Seung Hong CHOI ; Tae-Bin WON ; Doo Hee HAN
Journal of Korean Medical Science 2024;39(45):e321-
Background:
Olfactory dysfunction is a frequently encountered sensory disorder that increases with aging, assessed magnetic resonance imaging (MRI); however, reference quantitative values for associated anatomical structures have rarely been suggested. The aim of this study was to assess the parameters of the olfactory bulbs (OBs) and olfactory sulcus (OS) in Korean adults according to age, along with their olfactory function.
Methods:
We retrospectively evaluated 217 consecutive patients (104 men, 113 women;mean age, 52.4 ± 15.6 years) who underwent sellar MRI and olfactory function testing before transsphenoidal approach at a single tertiary center from March 2022 to December 2023. Based on the T2-weighted MRI, we evaluated the quantitative size parameters and morphological features of patients’ OB and OS, along with their olfactory function test scores. We assessed the relationship between OB volume and age in pairwise correlations.
Results:
The mean OB volume was 45.6 ± 15.3 mm 3 in all patients. The patients’ mean Korean version of the Sniffin’ Sticks (KVSS) test II score was 26.8 ± 4.1. OB volume (P < 0.001), height (P < 0.001), and anteroposterior diameter (APD) (P < 0.001) differed significantly among the different age groups. Reduced OB volume was significantly associated with aging (r = –0.58, P < 0.001) and a decline in olfactory function scores (r = 0.34, P < 0.001).
Conclusion
Based on MRI, we proposed reference OB and OS values in adults of different age groups, highlighting the reduction in OB parameters, especially height and APD along with volume associated with aging and olfactory decline. These values can be useful for evaluating adult patients undergoing MRI for olfactory dysfunction.

Result Analysis
Print
Save