1.Methodological establishment of red blood cell lysis method for handling Rh typing double group samples
Lu LI ; Bin WANG ; Junjie WEI ; Xiaolin SUN ; Haiyun LIU ; Weixin WU ; Yinze ZHANG
Chinese Journal of Blood Transfusion 2026;39(1):114-117
Objective: To establish an accurate and rapid typing method for Rh typing of samples from patients who have received recent blood transfusions by utilizing the difference in osmotic fragility between fresh and old red blood cells. Methods: A lysing solution suitable for destroying old RBCs was prepared. Sixty-one samples collected in our hospital in 2024 with Rh typing of double groups were treated with the lysing solution to remove the old allogeneic red blood cells while preserving the patient's own fresh red blood cells, followed by repeat Rh typing tests. Results: For 61 samples with Rh typing in double groups, 41 were accurately detected identified through the red blood cell lysis method, yielding an identification rate of 67.21%. No significant difference was observed compared to the detection rate of the commonly used capillary centrifugation modified method (χ
=0.103, P>0.05). Conclusion: The red blood cell lysis method provides a novel and rapid experimental approach for clinical use in processing Rh-typed samples that are of double groups, thereby offering a basis for Rh compatibility blood transfusion.
2.Distribution characteristics of bacterial communities in central air-conditioning ventilation systems of a Grade 3A hospital in Shanghai based on 16S rRNA sequencing
Jun NI ; Haiyun ZHANG ; Jian CHEN ; Lijun ZHANG ; Yongping LIU ; Xiaojing LI ; Yiming ZHENG ; Liping ZHANG
Journal of Environmental and Occupational Medicine 2025;42(6):732-739
Background A diverse cohort of patients and susceptible individuals congregate in healthcare facilities, where exposure to pathogenic microorganisms associated with respiratory infectious diseases constitutes a significant risk factor for cross-infection. Central air-conditioning ventilation systems improve some indoor environment indicators while exacerbating the risk of transmission of respiratory infectious diseases. Objective To investigate the distribution characteristics of microbial communities in the central air-conditioning ventilation systems of hospitals, providing a scientific basis for the selection of microbial indicators in hygiene standards for hospital central air-conditioning ventilation systems and for hospital risk early warning systems. Methods In October 2023, two central air-conditioning ventilation systems were selected from a Grade 3A hospital in Shanghai: one was an all-air air-conditioning system serving the waiting area on the ground floor, and the other was a fan coil plus fresh air system serving the outpatient area on the third floor. Samples from four different components of the ventilation systems—air outlets, filters, surface coolers, and condensate trays—were collected for high-throughput sequencing of the 16S rRNA gene to analyze bacterial communities. Alpha-diversity and beta-diversity analyses were performed to investigate the microbial community composition and diversity characteristics of the hospital central air-conditioning ventilation systems. Functional analysis was conducted to determine the relative abundance of bacterial functions in these systems.Results A total of 528 operational taxonomic units (OTUs) were identified, encompassing 20 bacterial phyla, 37 classes, 79 orders, 123 families, and 240 genera. The analysis revealed that the bacterial community was predominantly composed of Proteobacteria, Gemmatimonadates, Bacteroidetes, and Actinobacteria. The diversity analysis indicated that bacterial community richness and diversity were highest in the condensate trays, while no statistically significant differences (P > 0.05) were observed in the bacterial community composition among the air outlets, filters, and surface coolers. The functional analysis showed that the bacterial communities in the central air-conditioning ventilation systems primarily exhibited chemoheterotrophic, oxidative energy-dependent heterotrophic, and ureolytic functional characteristics. Conclusion The dominance of Proteobacteria suggests that this phylum exhibits strong adaptability in the central air-conditioning ventilation systems, possibly related to its ability to survive and reproduce under varying environmental conditions. The diversity analysis indicates that the condensate tray is a critical area for bacterial proliferation in the central air-conditioning ventilation systems. The similarity in environmental conditions among the air outlets, filters, and surface coolers result in similar bacterial community structures. The functional analysis reveals that the bacterial communities possess robust energy conversion and metabolic capabilities, potentially contributing to processes such as organic matter decomposition and nitrogen cycling within the central air-conditioning ventilation systems.
3.Application of bicuspid pulmonary valve sewn by 0.1 mm expanded polytetrafluoroethylene in right ventricle outflow tract reconstruction
Jianrui MA ; Tong TAN ; Miao TIAN ; Jiazichao TU ; Wen XIE ; Hailong QIU ; Shuai ZHANG ; Jian ZHUANG ; Jimei CHEN ; Jianzheng CEN ; Shusheng WEN ; Haiyun YUAN ; Xiaobing LIU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(08):1127-1132
Objective To introduce a modified technique of right ventricular outflow tract (RVOT) reconstruction using a handmade bicuspid pulmonary valve crafted from expanded polytetrafluoroethylene (ePTFE) and to summarize the early single-center experience. Methods Patients with complex congenital heart diseases (CHD) who underwent RVOT reconstruction with a handmade ePTFE bicuspid pulmonary valve due to pulmonary regurgitation at Guangdong Provincial People’s Hospital from April 2021 to February 2022 were selected. Postoperative artificial valve function and right heart function indicators were evaluated. Results A total of 17 patients were included, comprising 10 males and 7 females, with a mean age of (18.18±12.14) years and a mean body weight of (40.94±19.45) kg. Sixteen patients underwent reconstruction with a handmade valved conduit, with conduit sizes ranging from 18 to 24 mm. No patients required mechanical circulatory support, and no in-hospital deaths occurred. During a mean follow-up period of 12.89 months, only one patient developed valve dysfunction, and no related complications or adverse events were observed. The degree of pulmonary regurgitation was significantly improved post-RVOT reconstruction and during follow-up compared to preoperative levels (P<0.001). Postoperative right atrial diameter, right ventricular diameter, and tricuspid regurgitation area were all significantly reduced compared to preoperative values (P<0.05). Conclusion The use of a 0.1 mm ePTFE handmade bicuspid pulmonary valve for RVOT reconstruction in complex CHD is a feasible, effective, and safe technique.
4.Equivalence of SYN008 versus omalizumab in patients with refractory chronic spontaneous urticaria: A multicenter, randomized, double-blind, parallel-group, active-controlled phase III study.
Jingyi LI ; Yunsheng LIANG ; Wenli FENG ; Liehua DENG ; Hong FANG ; Chao JI ; Youkun LIN ; Furen ZHANG ; Rushan XIA ; Chunlei ZHANG ; Shuping GUO ; Mao LIN ; Yanling LI ; Shoumin ZHANG ; Xiaojing KANG ; Liuqing CHEN ; Zhiqiang SONG ; Xu YAO ; Chengxin LI ; Xiuping HAN ; Guoxiang GUO ; Qing GUO ; Xinsuo DUAN ; Jie LI ; Juan SU ; Shanshan LI ; Qing SUN ; Juan TAO ; Yangfeng DING ; Danqi DENG ; Fuqiu LI ; Haiyun SUO ; Shunquan WU ; Jingbo QIU ; Hongmei LUO ; Linfeng LI ; Ruoyu LI
Chinese Medical Journal 2025;138(16):2040-2042
5.Associations between suicidal ideation and clinical features, inflammation and thyroid hormones in patients with schizophrenia
Haiyun Yu ; Lewei Liu ; Xi Zhang ; Yinghan Tian ; Huanzhong Liu
Acta Universitatis Medicinalis Anhui 2025;60(4):748-754
Objective:
To investigate associations of suicidal ideation with clinical features, inflammatory markers, and thyroid hormones in patients with schizophrenia.
Methods:
The subjects of this study were 203 schizophrenic patients, grouped on the basis of suicidal ideation. Clinical characteristics were assessed using multiple scales. Neutrophil to lymphocyte ratio(NLR), platelet to lymphocyte ratio(PLR), monocyte to lymphocyte ratio(MLR) and thyroid hormones were also detected. SPSS 23.0 was used for statistical analyses.
Results :
The prevalence of suicidal ideation was 21.7% in patients with schizophrenia. Logistic stepwise regression analyses showed that Calgary depression scale(CDSS) total score(OR=1.490, 95%CI=1.287-1.724,P<0.001), insomnia severity index scale(ISI) total score(OR=1.096, 95%CI=1.011-1.187,P=0.025), modified overt aggression scale(MOAS) total score(OR=1.111, 95%CI=1.016-1.215,P=0.021), MLR(Ln)(OR=15.123, 95%CI=3.868-59.125,P<0.001), and triiodothyronine(T3)(OR=0.037, 95%CI=0.003-0.388,P=0.006) were the independent influences of suicidal ideation. Additionally, receiver operating characteristic(ROC) curve analyses revealed that the five-item combination of CDSS total score, ISI total score, MOAS total score, MLR(Ln), and T3(AUC=0.908, 95%CI=0.867-0.949,P<0.001) had better ability to identify suicidal ideation.
Conclusion
The risk of suicidal ideation is relatively high in patients with schizophrenia, and there may be stronger associations between suicidal ideation and depression, insomnia, aggression, MLR, and T3.
6.Influencing factors and construction of a nomogram prediction model for cardiac valve calcification in elderly patients with diabetic nephropathy undergoing maintenance hemodialysis
Ran LUO ; Hua ZHANG ; Haiyun SUN
Journal of Clinical Medicine in Practice 2025;29(11):118-123,134
Objective To analyze the influencing factors of cardiac valve calcification(CVC)in elderly patients with diabetic nephropathy undergoing maintenance hemodialysis and to construct and validate a nomogram prediction model.Methods A total of 280 elderly patients with diabetic ne-phropathy undergoing maintenance hemodialysis were selected as study subjects and divided into CVC group and non-CVC group based on the occurrence of CVC.Clinical data of the two groups were com-pared.The least absolute shrinkage and selection operator(LASSO)-Logistic regression analysis was used to screen the influencing factors of CVC occurrence in patients.A nomogram prediction model was constructed based on these factors and its predictive performance was validated.Results Among 280 patients,91 developed CVC,with an incidence rate of 32.50%.Patients in the CVC group had higher age,dialysis vintage,proportion of secondary hyperparathyroidism,proportion of valvular insufficiency,proportion of left ventricular hypertrophy,systolic blood pressure,calcium-phosphorus product,and serum levels of fibroblast growth factor 23(FGF23),soluble growth stimulation expressed gene 2protein(sST2),retinol-binding protein(RBP),and pentraxin 3(PTX3)compared to the non-CVC group.In contrast,low-density lipoprotein and Klotho levels were lower in the CVC group(P<0.05).LASSO-Logistic regression analysis revealed that age,secondary hyperparathyroidism,calcium-phosphorus product,and serum levels of FGF23,Klotho,sST2,RBP,and PTX3 were in-dependent influencing factors for CVC occurrence in elderly patients with diabetic nephropathy undergoing maintenance hemodialysis(P<0.05).A nomogram prediction model was constructed based on these independent influencing factors.The receiver operating characteristic(ROC)curve and calibration curve demonstrated that the model had good discrimination,accuracy,and predictive performance.Conclusion Age,secondary hyperparathyroidism,calcium-phosphorus product,and serum levels of FGF23,Klotho,sST2,RBP,and PTX3 are independent influencing factors for CVC occurrence in elderly patients with diabetic nephropathy undergoing maintenance hemodialysis.The nomogram prediction model constructed based on these factors exhibits high discrimination,accura-cy,and predictive performance.
7.Associations between qi stagnation constitution, suboptimal health status, and lifestyle factors in southern China: A population-based cross-sectional study
Haiyun Zhang ; Jieyu Chen ; Jieling Chen ; Yangzhi Liu ; Jiahui Yu ; Ji Wang ; Yumei Zhou ; Longmei Yu ; Hiu Yee Kwan ; Xiaoshan Zhao
Journal of Traditional Chinese Medical Sciences 2025;2025(4):521-530
ObjectiveTo study the relationship between qi stagnation constitution and suboptimal health status (SHS) or lifestyle.MethodsFrom 2012 to 2013, we conducted a cross-sectional survey of 24 159 Chinese individuals aged 12–80 years. The qi stagnation constitution was assessed using the Constitution in Chinese Medicine Questionnaire. Health status was evaluated through medical records and the Subhealth Measurement Scale V1.0 (SHMS V1.0). Health-promoting lifestyles were measured using the Health-Promoting Lifestyle Profile II (HPLP-II).ResultsOf the 24 159 participants, 16.1% and 15.2% were classified as “always” and “sometimes” having the qi stagnation constitution, respectively. Those classified as “rarely” having the qi stagnation constitution scored higher on both the HPLP-II and SHMS V1.0. The participants classified as “always” having the qi stagnation constitution showed a significant association with SHS or disease compared to other imbalanced constitutions. Those in the “always” category were approximately 21 times more likely to be classified as having SHS (odds ratio [OR]: 21.17, 95% confidence interval [CI]: 15.74–28.45), whereas those in the “sometimes” category were approximately six times more likely (OR: 5.89, 95% CI: 5.04–6.90). Accordingly, the qi stagnation constitution score was significantly associated with the diagnosis of SHS, with an area under the curve of 0.77 (P .001). A score of 18.75 yielded the highest Youden Index (0.407), with a sensitivity of 60.5% and a specificity of 80.3%. Significant associations were observed between health-promoting lifestyles and qi stagnation constitution severity in an ordinal regression analysis (P .001). Protective factors included stress management (OR: 1.59), self-actualization (OR: 1.57), and exercise (OR: 1.36). In contrast, poorer interpersonal relationships (OR: 0.79), greater health responsibilities (OR: 0.86), and poorer nutrition (OR: 0.91) were associated with increased severity.ConclusionModulating the qi stagnation constitution through lifestyle interventions may help prevent the progression of SHS to disease, which aligns with core preventive principles in traditional Chinese medicine.
8.Establishment of internal quality control methodology for blood transfusion compatibility testing
Lu LI ; Xiaolin SUN ; Junjie WEI ; Ruiqi LIU ; Weixin WU ; Haiyun LIU ; Yinze ZHANG
Chinese Journal of Blood Transfusion 2024;37(4):399-404
【Objective】 To monitor the effectiveness and accuracy of the blood transfusion compatibility test system by self-made weakly positive internal quality control products. 【Methods】 Red blood cells from DAT(-) healthy subjects were selected, and B/RhD(-)E(-) red blood cells were selected as tube 1. A/RhD(+ )E(+ ) was selected as tube 2 to prepare blood group quality control products according to the principle of blood group antigen compatibility, and red blood cell preservation solution and corresponding ABO blood group reagent antibody were added to make the agglutination intensity of microcolumn gel method in reverse blood typing reach a low positive value (1+ ). Tube 3 and tube 4 were prepared with five different preservation media: plasma, serum, antibody diluent, mixture of equal plasma and antibody diluent, and mixture of equal serum and antibody diluent, respectively. IgM anti-E antibody was added to tube 3, and IgG anti-D antibody was added to tube 4, so that the agglutination intensity of microcolumn gel method reached a low positive value (1+ ). 【Results】 Comparison between the 5 different preservation media showed that the preservation medium of antibody diluent was the most stable for weakly positive antibody (F=11.35, P<0.05), Agglutination intensity 1+ is assigned 5 points by AABB Technical Manual, and its score was 5.25±1.75 points. 【Conclusion】 The use of self-made weakly positive quality control products can improve the effectiveness, accuracy and sensitivity of the monitoring system, thus achieving internal quality control and ensuring the safety of clinical blood use.
9.Domestic self-expanding interventional pulmonary valve stent in transthoracic implantation for pulmonary valve regurgitation: A prospective cohort study
Ziqin ZHOU ; Taoran HUANG ; Naijimuding ABUDUREXITI ; Yong ZHANG ; Haiyun YUAN ; Nianjin XIE ; Hongwen FEI ; Hui LIU ; Jian ZHUANG ; Jimei CHEN ; Shusheng WEN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(09):1305-1312
Objective To analyze and summarize the early and medium-term outcomes of self-expanding interventional pulmonary valve stent (SalusTM) for right ventricular outflow tract dysfunction with severe pulmonary valve regurgitation. Methods We established strict enrollment and follow-up criteria. Patients who received interventional pulmonary valve in transthoracic implantation in Guangdong Provincial People’s Hospital from September 2, 2021 to July 18, 2023 were prospectively included, and all clinical data of patients were collected and analyzed. Results A total of 38 patients with severe pulmonary regurgitation were included, with 23 (60.5%) males and 15 (39.5%) females. The mean age was 24.08±8.12 years, and the mean weight was 57.66±13.54 kg. The preoperative mean right ventricular end-diastolic volume index (RVEDVI) and right ventricular end-systolic volume index (RVESVI) were 151.83±42.84 mL/m2 and 83.34±33.05 mL/m2, respectively. All patients successfully underwent transcatheter self-expandable pulmonary valve implantation, with 3 (7.9%) patients experiencing valve stent displacement during the procedure. Perioperative complications included 1 (2.6%) patient of postoperative inferior wall myocardial infarction and 1 (2.6%) patient of poor wound healing. The median follow-up time was 12.00 (6.00, 17.50) months. During the follow-up period, there were no deaths or reinterventions, and no patients had recurrent severe pulmonary regurgitation. Three (7.9%) patients experienced chest tightness and chest pain, and 1 (2.6%) patient developed frequent ventricular premature beats. Compared with preoperative values, the right atrial diameter, right ventricular diameter, and tricuspid annular plane systolic excursion were significantly reduced at 6 months and 1 year postoperatively, with improvement in the degree of pulmonary regurgitation (P<0.01). Compared with preoperative values, RVEDVI and RVESVI decreased to 109.51±17.13 mL/m2 and 55.88±15.66 mL/m2, respectively, at 1 year postoperatively (P<0.01). Conclusion Self-expanding interventional pulmonary valve in transthoracic implantation is safe and effective for severe pulmonary valve regurgitation and shows good clinical and hemodynamic results in one-year outcome.
10.Outcomes of total cavopulmonary connection in the treatment of functional single ventricle with heterotaxy syndrome: A propensity score matching study
Linjiang HAN ; Xiang LIU ; Jianrui MA ; Ziqin ZHOU ; Jiazichao TU ; Ruyue ZHANG ; Miao TIAN ; Ying LI ; Haiyun YUAN ; Shusheng WEN ; Jimei CHEN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(04):510-518
Objective To comprehensively analyze the clinical outcomes of total cavopulmonary connection (TCPC) in the treatment of functional single ventricle combined with heterotaxy syndrome (HS). Methods A retrospective analysis was conducted on the patients with functional single ventricle and HS who underwent TCPC (a HS group) in Guangdong Provincial People's Hospital between 2004 and 2021. The analysis focused on postoperative complications, long-term survival rates, and identifying factors associated with patient survival. Early and late postoperative outcomes were compared with matched non-HS patients (a non-HS group). Results Before propensity score matching, 55 patients were collected in the HS group, including 42 males and 13 females, with a median age of 6.0 (4.2, 11.8) years and a median weight of 17.0 (14.2, 28.8) kg. Among the patients, there were 53 patients of right atrial isomerism and 2 patients of left atrial isomerism. Eight patients underwent TCPC in one stage. TCPC procedures included extracardiac conduit (n=39), intracardiac-extracardiac conduit (n=14), and direct cavopulmonary connection (n=2). Postoperative complications included infections in 27 patients, liver function damage in 19 patients, and acute kidney injury in 11 patients. There were 5 early deaths. The median follow-up time was 94.7 (64.3, 129.8) months. The 1-year, 5-year, and 10-year survival rates were 87.2%, 85.3%, and 74.3%, respectively. After propensity score matching, there were 45 patients in the HS group and 81 patients in the non-HS group. Compared to the non-HS group, those with HS had longer surgical and mechanical ventilation time, higher infection rates (P<0.05), and a 12.9% lower 10-year survival rate. Multivariate Cox regression analysis identified asplenia was a risk factor for mortality (HR=8.98, 95%CI 1.86-43.34, P=0.006). Conclusion Compared to non-HS patients, patients with HS have lower survival rates after TCPC, and asplenia is an independent risk factor for the survival of these patients.


Result Analysis
Print
Save
E-mail