1.Effect of Huayu Tongluo moxibustion on learning-memory ability in rats with vascular dementia based on hippocampal Mst1/NF-κB p65 pathway.
Ping WANG ; Jun YANG ; Yu KONG ; Yating ZHANG ; Yinqiu FAN ; Haiping SHI ; Lanying LIU
Chinese Acupuncture & Moxibustion 2025;45(1):53-60
OBJECTIVE:
To observe the effects of Huayu Tongluo (transforming stasis and unblocking collaterals) moxibustion on learning-memory ability and hippocampal mammalian sterile 20-like kinase 1 (Mst1)/nuclear factor κB (NF-κB) p65 pathway related to inflammatory response in rats with vascular dementia (VD).
METHODS:
A total of 60 male Wistar rats of SPF grade were randomly divided into a sham operation group (12 rats) and a modeling group (48 rats). VD model was established by the method of modified bilateral common carotid artery permanent ligation in the modeling group. Thirty-six rats with successful modeling were randomly divided into a model group, a moxibustion group and a western medication group, with 12 rats in each group. Huayu Tongluo moxibustion was applied at "Dazhui" (GV14), "Baihui" (GV20) and "Shenting" (GV24) in the moxibustion group, 20 min each time, once a day, 7 day-intervention was as one course, and 1 day-interval was taken between two courses, for a total of 3 courses. In the western medication group, piracetam was given 0.72 mg/kg by intragastric administration, twice a day, the course of intervention was same as that of the moxibustion group. The learning-memory ability was detected by Morris water maze test; the morphology of hippocampal CA1 region was observed by HE staining; the mRNA expression of Mst1, M1 microglia markers CD86, interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) was detected by real-time PCR; the levels of IL-6 and TNF-α in hippocampus were detected by ELISA; and the protein expression of Mst1 and NF-κB p65 in hippocampus was detected by Western blot in rats of each group.
RESULTS:
Compared with the sham operation group, the escape latency was prolonged in the model group (P<0.05); compared with the model group, the escape latency was shortened in the moxibustion group and the western medication group (P<0.05). The cells in the CA1 region of hippocampus were disordered, cell collapse and irregular nuclei could be observed in the model group; compared with the model group, the cell arrangement in the CA1 region of hippocampus was more regular, and the damage was improved in the moxibustion group and the western medication group. Compared with the sham operation group, the mRNA expression of Mst1, CD86, IL-6 and TNF-α, as well as the protein expression of Mst1, NF-κB p65 in hippocampus were increased in the model group (P<0.05). Compared with the model group, the mRNA expression of Mst1, CD86, IL-6 and TNF-α, as well as the protein expression of Mst1, NF-κB p65 in hippocampus were decreased in the moxibustion group and the western medication group (P<0.05). Compared with the sham operation group, the levels of IL-6 and TNF-α in hippocampus were increased in the model group (P<0.05). Compared with the model group, the levels of IL-6 and TNF-α in hippocampus were decreased in the moxibustion group and the western medication group (P<0.05).
CONCLUSION
Huayu Tongluo moxibustion can improve the learning-memory ability of VD rats, the mechanism may be related to regulating the activation of microglia through Mst1/NF-κB p65 pathway, reducing the release of pro-inflammatory factors i.e. IL-6 and TNF-α, so as to alleviating the damage of inflammatory factors in the hippocampus of VD rats.
Animals
;
Male
;
Rats
;
Moxibustion
;
Hippocampus/metabolism*
;
Rats, Wistar
;
Dementia, Vascular/genetics*
;
Memory/drug effects*
;
Humans
;
Transcription Factor RelA/genetics*
;
Learning
;
Protein Serine-Threonine Kinases/genetics*
;
Acupuncture Points
;
Interleukin-6/genetics*
;
Signal Transduction/drug effects*
;
Drugs, Chinese Herbal
2.Professor YANG Jun's experience in treatment of refractory facial paralysis with refined mode of acupuncture and moxibustion.
Haiping SHI ; Yinqiu FAN ; Yuanyuan ZHANG ; Yating ZHANG ; Qingping ZHANG ; Jun YANG
Chinese Acupuncture & Moxibustion 2025;45(2):222-226
The paper summarizes Professor YANG Jun's experience in treatment of refractory facial paralysis with the refined mode of acupuncture and moxibustion, so as to provide new ideas and methods for the disease treated with acupuncture and moxibustion. Professor YANG Jun puts forward the refined mode of diagnosis and treatment of acupuncture and moxibustion for refractory facial paralysis. On the basis of syndrome/pattern differentiation of TCM, combined with meridian theory and modern anatomy, the symptom differentiation and meridian differentiation are performed accurately. By selecting local acupoints (e.g. Touwei [ST8], Sibai [ST2], Cuanzhu [BL2] and Yangbai [GB14]), distal acupoints (e.g. Zusanli [ST36], Hegu [LI4] and Jinsuo [GV8]), specific acupoints (e.g.Qianzheng [EX-HN16] and Touqiaoyin [GB11]) and the acupoints for regulating the mind (e.g. Dazhui [GV14] and Shuigou [GV26]), the prescription is composed. The different needling techniques are delivered at the acupoints (e.g. point-to-point needling with long needle, stuck needling by lifting and dragging, and balance needling on the healthy side). Besides, the facial rehabilitation is considered as the adjuvant treatment. This mode of treatment obtains the precise diagnosis and treatment to achieve the utmost therapeutic effects.
Humans
;
Moxibustion
;
Acupuncture Therapy/history*
;
Facial Paralysis/therapy*
;
Acupuncture Points
;
Male
;
Meridians
;
Female
;
History, 21st Century
;
History, 20th Century
3.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
4.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Consensus on informed consent for orthodontic treatment
Yang CAO ; Bing FANG ; Zuolin JIN ; Hong HE ; Yuxing BAI ; Lin WANG ; Haiping LU ; Zhihe ZHAO ; Tianmin XU ; Weiran LI ; Min HU ; Jinlin SONG ; Jun WANG ; Fang JIN ; Ding BAI ; Xianglong HAN ; Yuehua LIU ; Bin YAN ; Jie GUO ; Jiejun SHI ; Yongming LI ; Zhihua LI ; Xiuping WU ; Jiangtian HU ; Linyu XU ; Lin LIU ; Yi LIU ; Yanqin LU ; Wensheng MA ; Shuixue MO ; Liling REN ; Shuxia CUI ; Yongjie FAN ; Jianguang XU ; Lulu XU ; Zhijun ZHENG ; Peijun WANG ; Rui ZOU ; Chufeng LIU ; Lunguo XIA ; Li HU ; Weicai WANG ; Liping WU ; Xiaoxing KOU ; Jiali TAN ; Yuanbo LIU ; Bowen MENG ; Yuantao HAO ; Lili CHEN
Chinese Journal of Stomatology 2025;60(12):1327-1336
This consensus was developed by the Orthodontic Society of the Chinese Stomatological Association to provide a systematic, scientific, and practical guideline for informed consent in orthodontic care. Orthodontic treatment is typically lengthy, highly individualized, and involves multiple factors such as growth and development, occlusal function, and facial esthetics. Rapid technological advances and diverse risk profiles make the traditional reliance on orthodontist experience or institutional templates insufficient to ensure patients′ full understanding and autonomous decision-making. To address this, the expert panel conducted extensive reviews of domestic and international guidelines, analyzed representative dispute cases, and performed multicenter patient-clinician surveys. Using a multi-round Delphi method, the group established a standardized informed consent framework covering the initial consultation, treatment, and retention phases. The consensus emphasizes that informed consent is not only a fundamental legal and ethical requirement but also a key step in building trust, improving patient compliance, and enhancing treatment satisfaction. Orthodontists should clearly and comprehensively explain treatment plans, potential risks, uncertainties, and associated costs, while respecting the autonomy of patients or guardians, and maintain continuous communication and dynamic evaluation throughout the treatment process. The release of this consensus provides unified and authoritative guidance for clinical orthodontics, helping to standardize informed consent, enhance its transparency, safeguard patient rights, reduce medical risks, and promote high-quality, sustainable development of orthodontic practice.
7.Effects of Modified Wendan Decoction Combined with Intestinal Regulation and Mind-Regulating Acupuncture on Cognitive,Social,and Self-Care Abilities in Children with Autism Spectrum Disorder
Hui FANG ; Haiping SHI ; Shaoxin LI ; Jinsong BAO ; Hong LI
Journal of Guangzhou University of Traditional Chinese Medicine 2025;42(10):2475-2481
Objective To evaluate the effects of Modified Wendan Decoction combined with Intestinal Regulation and Mind-Regulating Acupuncture on cognitive,social,and self-care abilities in children with autism spectrum disorder(ASD).Methods A total of 100 children diagnosed with ASD at Anhui Children's Hospital(inpatient and outpatient)from February 2023 to March 2024 were enrolled.The participants were divided into an observation group(n=50)and a control group(n=50)using a random number table.The control group received conventional rehabilitation training and Intestinal Regulation and Mind-Regulating Acupuncture,while the observation group received additional Modified Wendan Decoction.Both groups underwent a 2-month treatment period.Post-treatment assessments included clinical efficacy,changes in Childhood Autism Rating Scale(CARS)scores,Autism Behavior Checklist(ABC)scores,and Autism Treatment Evaluation Checklist(ATEC)scores were observed.Additionally,Social Responsiveness Scale(SRS)and Infant-Junior Middle School Student Social Life Abilities Scale(S-M)scores were compared between groups.Results(1)During the study,1 case was lost to follow-up in the observation group and 2 in the control group,leaving 49 and 48 cases for final analysis,respectively.(2)After treatment,both groups showed significant improvements in CARS,ABC,and ATEC scores(P<0.05),with the observation group demonstrating superior improvements compared to the control group,the difference being statistically significant(P<0.05).(3)Similarly,both groups exhibited marked improvements in SRS and S-M scores(P<0.05),with the observation group outperforming the control group,the difference being statistically significant(P<0.05).(4)The total effective rate was 81.63%(40/49)in the observation group versus 56.25%(27/48)in the control group,indicating significantly better efficacy in the observation group,the difference being statistically significant(P<0.05).Conclusion Modified Wendan Decoction combined with Intestinal Regulation and Mind-Regulating Acupuncture significantly improves clinical symptoms and enhances cognitive,social,and self-care abilities in children with ASD,demonstrating notable therapeutic efficacy.
8.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
9.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
10.Isolation,identification and characteristics of poultry Clostridium perfringens in the Yangzhou region of Jiangsu Province
Haiping XIE ; Zewei LI ; Yifei CHEN ; Huoying SHI
Chinese Journal of Veterinary Science 2025;45(10):2206-2212,2221
The purpose of this study was to understand the epidemiological and biological character-istics of Clostridium perfringens in avian origin in Yangzhou.A total of 200 intestinal samples(90 from chickens and 110 from ducks)collected from different markets were isolated and identified by isolation and culture,morphological observation,staining microscopy,biochemical tests and other methods,antimicrobial susceptibility test by K-B paper method,and toxin type of isolated bacteria was detected by PCR.Five isolates were screened according to the characteristics of host origin,se-rotype and drug resistance,and multi-locus sequence typing analysis was carried out,and a phylo-genetic tree based on α toxin gene sequences was constructed for isolates from different sources.After morphological and molecular biological identification,a total of 61 strains of Clostridium perfringens were isolated,and the isolation rate was 30.5%,all of which were type A.The antimi-crobial susceptibility results showed that the isolate had the highest resistance rate to amikacin,followed by tetracycline and cotrimoxazole,and was more sensitive to ceftriaxone,penicillin,amoxicillin and imipenem.Multi-drug resistance is very serious,with six or more strains resistant to antibiotics emerging in every market.A total of five different ST types(STs)were found by multi-site sequence analysis,namely ST833,ST834,ST363,ST835,and ST837,and all of them were new ST types except ST363.The information from ST 363 is consistent with clinical isolate of Clostridium perfringens,suggesting that more attention needs to be paid to zoonotic diseases caused by Clostridium perfringens.The α toxin genes of the five isolates were located in four dif-ferent branches in the phylogenetic tree,indicating their genetic diversity,while the isolates from different provenances of the same source were located in the same branch,indicating that they had a closer evolutionary relationship.The Clostridium perfringens from poultry in Yangzhou are mainly type A,and with severe drug resistance and multi-drug resistance present.This research provides scientific evidence for the epidemiology and control of Clostridium perfringens.

Result Analysis
Print
Save
E-mail