1.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
2.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
3.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
4.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
5.Comparison of the accuracy of an ultrasonic-based jaw tracking device with conventional electronic tracking device
Xinyi GU ; Tingzi HU ; Zidan ZHANG ; Fuming HE ; Jiejun SHI ; Haiping YANG
The Journal of Advanced Prosthodontics 2025;17(1):47-58
PURPOSE:
This study aimed to evaluate the accuracy of the ultrasonic jaw tracking system by comparing with the conventional electronic system in recording condylar movements.
MATERIALS AND METHODS:
Twenty-six subjects with normal occlusion participated in the study. The CADIAX® 4 and Jaw Motion Analyzer (JMA) systems were used to record condylar movement trajectories during mandibular border movements (protrusive/retrusive, lateral, and wide mouth opening), with each movement repeated three times. Both systems used facebows and sensors to locate the condylar axis points and capture movement trajectory data. Paired t-tests were used for normally distributed data, while the Wilcoxon rank-sum test was applied to non-normally distributed data. The level of significance was set at α = .05.
RESULTS:
The maximum condylar displacement in the sagittal plane during mandibular border movements and the sagittal condylar inclination (SCI) values on both the left and right sides showed no significant difference between the two systems (P > .05). The Bennett angle (BA) values on both the left and right sides measured by the JMA system were significantly higher than those measured by the CADIAX® 4 system (P < .05). The comfort levels of the JMA system were significantly higher than the CADIAX® 4 system (P < .05).
CONCLUSION
Through this study, it was found that the accuracy of the ultrasonic jaw tracking system was comparable with the conventional electronic system, except for the Bennett angle measurement. In terms of comfort and ease of use, the ultrasonic jaw tracking system is more favored.
6.Regulation of histidine metabolism by Lactobacillus Reuteri mediates the pathogenesis and treatment of ischemic stroke.
Kangrui HU ; Zhihao ZHOU ; Haofeng LI ; Jijun XIAO ; Yun SHEN ; Ke DING ; Tingting ZHANG ; Guangji WANG ; Haiping HAO ; Yan LIANG
Acta Pharmaceutica Sinica B 2025;15(1):239-255
Increasing evidence has underscored the significance of post-stroke alterations along gut-brain axis, while its role in pathogenesis and treatment of ischemic stroke (IS) remains largely unexplored. This study aimed to elucidate the therapeutic effects and action targets of Panax notoginseng saponins (PNS) on IS and explore a novel pathogenesis and treatment strategy of IS via profiling the microbial community and metabolic characteristics along gut-brain axis. Our findings revealed for the first time that the therapeutic effect of PNS on IS was microbiota-dependent. Ischemia/reperfusion (I/R) modeling significantly down-regulated Lactobacilli in rats, and PNS markedly recovered Lactobacilli, particularly Lactobacillus reuteri (L.Reu). Metabolomics showed a significant reduction in serum histidine (HIS) in clinical obsolete IS patients and rehabilitation period I/R rats. Meanwhile, the L.Reu colonization in I/R rats exhibited significant neuroprotective activity and greatly increased HIS in serum, gut microbiota, and brain. Moreover, exogenous HIS demonstrated indirect neuroprotective effects through metabolizing to histamine. Notably, vagus nerve severance in I/R rats was performed to investigate HIS's neuroprotective mechanism. The results innovatively revealed that PNS could promote HIS synthesis in gut by enhancing L.Reu proportion, thereby increasing intracerebral HIS through peripheral pathway. Consequently, our data provided novel insights into HIS metabolism mediated by L.Reu in the pathogenesis and treatment of IS.
7.Water quality of self-provided wells water in Haidian District in Beijing in 2018 - 2022
Yongmei HU ; Xueying LIU ; Shuping ZHU ; Haiping CHEN
Journal of Public Health and Preventive Medicine 2024;35(3):86-89
Objective To investigate the water quality and sanitary conditions of rural self-provided wells water in Haidian District, Beijing, and to provide reference for strengthening water supply management of self-provided wells. Methods The water quality monitoring data of rural self-provided wells in Haidian District from 2018 to 2022 were analyzed. Results A total of 1 568 water samples were tested in 2018-2022 , of which 1 486 were qualified, with a qualified rate of 94.77%. The qualified rate in each year was 86.75% , 92.86% , 97.48% , 98.06% , and 99.34% , respectively , and the difference was statistically significant ( χ2= 75.296 , P<0.05). The qualified rates of sensory traits and general chemical indexes, toxicological indexes and microbial indexes were 97.70%, 97.58% and 98.28%, respectively. There were statistically significant differences in the qualified rates among the three indexes in 2018, 2019 and 2021 (P < 0.05). The unqualified indicators included total hardness, total number of colonies, total coliform, fluoride, nitrate and turbidity, with a qualified rate of 97.96%, 98.41%, 99.17%, 99.11%, 98.47% and 99.94%, respectively. Conclusion The water quality of self-provided wells in rural Haidian District is good. Relevant departments should continue to strengthen the supervision of self-provided wells, such as the supervision of self-provided wells disinfection devices and water treatment equipment, to ensure the safety of drinking water for residents.
8.Real-time Detection Method for Motion Artifact of Photoplethysmography Signals Based on Decision Trees
Linqi HU ; Yulin ZHANG ; Yongxin CHOU ; Haiping YANG ; Xiao HE
Chinese Journal of Medical Instrumentation 2024;48(3):285-292
PPG(photoplethysmography)holds significant application value in wearable and intelligent health devices.However,during the acquisition process,PPG signals can generate motion artifacts due to inevitable coupling motion,which diminishes signal quality.In response to the challenge of real-time detection of motion artifacts in PPG signals,this study analyzed the generation and significant features of PPG signal interference.Seven features were extracted from the pulse interval data,and those exhibiting notable changes were filtered using the dual-sample Kolmogorov-Smirnov test.The real-time detection of motion artifacts in PPG signals was ultimately based on decision trees.In the experimental phase,PPG signal data from 20 college students were collected to formulate the experimental dataset.The experimental results demonstrate that the proposed method achieves an average accuracy of(94.07±1.14)%,outperforming commonly used motion artifact detection algorithms in terms of accuracy and real-time performance.
9.Association between waist circumference and ischemic stroke: a prospective study in adults from Qingdao
Yuhui LI ; Lei LIU ; Dan HU ; Xiaoyan ZHENG ; Jun LYU ; Canqing YU ; Pei PEI ; Haiping DUAN ; Ruqin GAO ; Zengchang PANG ; Xiaocao TIAN ; Dianjianyi SUN
Chinese Journal of Epidemiology 2024;45(2):178-184
Objective:To analyze the association between waist circumference (WC) and ischemic stroke (IS).Methods:The data for the present study were from the prospective cohort study of China Kadoorie Biobank in Qingdao. Using baseline information and IS events of the participants, the Cox proportional hazard regression model and restricted cubic spline (RCS) were used to analyze the association between WC and IS.Results:A total of 33 355 participants were included in the study, with 302 008.88 person-years of follow-up. A total of 1 093 new cases of IS were observed. Multivariate Cox proportional hazard regression model analysis showed that compared to the respondents with normal WC (male <85.0 cm, female <80.0 cm), respondents with excessive WC (male ≥85.0 cm, female ≥80.0 cm) had a 78% higher risk of IS incidence [hazard ratio( HR)=1.78, 95% CI: 1.51-2.10], and the risk increased by 72% ( HR=1.72, 95% CI: 1.40-2.12) and 83% ( HR=1.83, 95% CI: 1.40-2.39) in men and women. According to the RCS, the increase in WC and the risk of IS showed an "S" trend of nonlinear dose-response relationship. Conclusions:The risk of IS would increase with the WC. Keeping a normal WC is important for preventing IS.
10.Association of solid fuel use for heating and smoking with respiratory diseases: a prospective cohort study
Yang YU ; Xiaocao TIAN ; Hua ZHANG ; Dan HU ; Jun LYU ; Canqing YU ; Pei PEI ; Dianjianyi SUN ; Ruqin GAO ; Zengchang PANG ; Haiping DUAN
Chinese Journal of Epidemiology 2024;45(10):1356-1361
Objective:To investigate the association between solid fuel use for heating, smoking, and respiratory diseases.Methods:This study is based on the Qingdao project of the China Kadoorie Biobank. After screening, 26 165 individuals were included in the study. We employed Cox proportional hazards regression models, stratified by risk age (in 5-year intervals) and sex while adjusting for confounding variables such as occupation and physical activity level to analyze the association between solid fuel use for heating, smoking, and increased risk of respiratory diseases.Results:Among the 26 165 participants, the average age of those using solid fuel for heating was (52.57±10.31) years, with females constituting 58.04% and former/current smokers accounting for 65.38%. The results indicated that both the solid fuel group and the former/current smoking group had a higher risk of respiratory diseases, with hazard ratios ( HR) (95% CI) of 1.21 (1.04-1.41) and 1.41 (1.16-1.71), respectively. For the duration of solid fuel use, the HR (95% CI) for 20 years or more, it was 1.27 (1.07-1.51). The multiplicative interaction term between solid fuel use and smoking was statistically significant. Conclusions:The use of solid fuel for heating and smoking significantly increases the risk of respiratory diseases, and there may be a multiplicative interaction between solid fuel use and smoking.


Result Analysis
Print
Save
E-mail