1.Correlation between plasma high-mobility group protein box 1 and the outcome after endovascular treatment in patients with acute large vessel occlusive stroke
Xin LIN ; Genghong XIA ; Xiaojiang DENG ; Miaodan LI ; Haiou LIANG ; Qindi ZHANG ; Liang ZHOU ; Jia YIN
International Journal of Cerebrovascular Diseases 2025;33(5):329-335
Objective:To investigate the dynamic changes of plasma high-mobility group box 1 (HMGB1) and its correlation with functional outcome and symptomatic intracranial hemorrhage (sICH) after endovascular treatment (EVT) in patients with acute large vessel occlusion stroke (ALVOS).Methods:Patients with ALVOS admitted to the Department of Neurology, Zengcheng District, Nanfang Hospital, Southern Medical University from June 2021 to April 2023 were included retrospectively. Plasma HMGB1 before EVT and at 6, 24, and 48 hours after procedure was detected, and the dynamic changes of plasma HMGB1 were compared and analyzed. The primary endpoint was the functional outcome evaluated using the modified Rankin Scale at 90 days of onset. A score of 0-2 was defined as good outcome and >2 was defined as poor outcome. The secondary endpoint was sICH, which was defined as the occurrence of hemorrhagic infarction after EVT and an increase of ≥4 in the National Institutes of Health Stroke Scale (NIHSS) score from baseline. Multivariate logistic regression analysis was used to evaluate the predictive value of HMGB1 for poor outcome and sICH. Results:A total of 73 patients with ALVOS received EVT were included. There were 54 males (74.0%), aged 62±12 years. The median time from onset to door was 90 minutes (interquartile range, 40-180 minutes), and the median time from onset to femoral artery puncture was 181 minutes (interquartile range, 140-280 minutes). Twenty-nine patients (39.7%) underwent bridging intravenous thrombolysis (IVT). At 90 days after onset, 37 patients (50.7%) had poor outcome, and 12 (16.4%) died during follow-up. Eleven patients (15.1%) developed sICH. After EVT, plasma HMGB1 showed a temporal increase, reaching its peak at 48 hours (median, 102.57 μg/L). Subgroup analysis showed that HMGB1 in the bridging IVT group at 6 hours ( P<0.05) and 24 hours ( P<0.05) after procedure were significantly higher than that at baseline. The non-bridging IVT group showed a significant increase at 6 hours after procedure ( P<0.05). There was no statistically significant difference in HMGB1 between the bridging IVT group and the non-bridging IVT group at the same time point. Multivariate logistic regression analysis showed that after adjusting for age, ischemic heart disease, triglycerides, uric acid, baseline NIHSS score, and sICH, the third quartile (adjusted odds ratio 7.087, 95% confidence interval 1.243-40.419; P=0.027) and fourth quartile (adjusted odds ratio 7.544, 95% confidence interval 1.260-45.172; P=0.027) of plasma HMGB1 were independent risk factors for poor outcome at 6 hours after procedure. The postoperative plasma HMGB1 in the sICH group was significantly higher than that in the non-sICH group ( P<0.05), but multivariate analysis showed no independent correlation between plasma HMGB1 and sICH. Conclusion:The elevation of plasma HMGB1 in patients with ALVOS at 6 hours after EVT is independently associated with poor outcome at 90 days after onset, but not with sICH.
2.Effects of laser solid forming of porous titanium on proliferation of osteoblast and RANKL/OPG expression.
Hui CHEN ; Shanshan DU ; Ping ZHEN ; Xusheng LI ; Xiaoyan LIANG ; Lijuan FAN ; Jie JIANG ; Haiou YANG ; Jun LIU
Journal of Central South University(Medical Sciences) 2016;41(12):1278-1284
To evaluate the effect of laser solid forming (LSF) of porous titanium on receptor activator of NF-κB ligand (RANKL)/osteoprorotegerin (OPG) expression and osteoblast cells growth.
Methods: The DMEM and sterile saline were used for porous titanium extract. The osteoblast cells were cultured in the extract while equal amount of DMEM and sterile saline were added to the control group. The growth of the cells were observed under an inverted phase contrast microscope. MTT was used to detect the growth inhibitory rates. The adhesion capacity of osteoblasts were measured. The growth in the material surface was examined by the electron microscope, and the expressions of RANKL and OPG were determined by Westen blot.
Results: At the first day, the osteoblast proliferation rate was significantly different (P<0.05), at the fourth and seventh day, the osteoblast proliferation rate was not significantly affected in the LSF group (P>0.05); at each time point, the osteoblast proliferation rate were significantly different between the two groups (P<0.05). Compared with the control group, RANKL and OPG protein expression were not significantly different (P>0.05). The laser solid forming of porous titanium showed well bone compatibility.
Conclusion: The porous titanium did not affect osteoblast proliferation due to its well bone compatibility. It did not affect the OPG/RANKL/RANK-axis system of bone metabolism, exibiting a wide applicable prospect for tissue engineering.
Biocompatible Materials
;
chemistry
;
Cell Adhesion
;
drug effects
;
Cell Proliferation
;
drug effects
;
Cells, Cultured
;
Culture Media
;
chemistry
;
Ligands
;
Osteoblasts
;
drug effects
;
Osteogenesis
;
drug effects
;
Osteoprotegerin
;
metabolism
;
Porosity
;
Receptor Activator of Nuclear Factor-kappa B
;
metabolism
;
Tissue Engineering
;
instrumentation
;
Tissue Scaffolds
;
chemistry
;
Titanium
;
pharmacology
3.Clinical significance of spiral CT three-dimensional reconstruction for measurement of Chinese calcaneal data
Zhen MENG ; Liang WU ; Xiaoliang SUN ; Zongming GONG ; Lei ZHANG ; Haiou CHEN
Chinese Journal of Tissue Engineering Research 2014;(20):3207-3211
BACKGROUND:Calcaneus is a kind of irregular bone, with complicated three-dimensional structure. Calcaneus is often measured with X-ray plain film, while spiral CT three-dimensional imaging is a potent technology for anatomic measurement and has good application prospect. However, little is known about it. OBJECTIVE:To measure calcaneal anatomic data in Chinese peoples with spiral CT three-dimensional reconstruction and to explore its clinical significance.
METHODS:Calcaneal spiral CT three-dimensional reconstruction in 100 Chinese adults (including 50 males and 50 females) were performed. The length, width, height of calcaneus, and Bohler’s and Gissane’s angles were measured after reconstruction, and compared with the data of westerners.
RESULTS AND CONCLUSION:The mean length, width and height of the Chinese calcaneus were respectively (74.60±5.06) mm, (29.71±2.93) mm and (45.23±4.46) mm in male group, and (71.48±5.36) mm, (26.65±3.01) mm and (42.23±4.49) mm in female group. There were no significant differences between male group and female group in al the above parameters (P>0.05). There was no significant difference in the Gissane’s angle between the two groups (123.3±8.5° versus 122.7±8.9°;P>0.05). The Bohler’s angle in male group (35.98±4.34)° was significantly lower than that in female group (38.81±4.43)° (P<0.05). The length, width and height of Chinese calcaneus were significantly lower than those of westerners (P<0.05). The Bohler’s angle and Gissane’s angle in Chinese adults showed no statistical significance compared with the westerners (P>0.05). Experimental findings indicate that, the length, width and height of Chinese calcaneus in female were lower than that in male, but Bohler’s angle is significantly higher than that in male, there was no significant difference in Gissane’s angle between males and females. Compared with the data of westerners, the length, width and height of Chinese adult calcaneus are significantly decreased, and no difference is found in Bohler’s angle and Gissane’s angle.
4.Reliability and validity of self-management instrument among Chinese people with schizophrenia
Haiou ZOU ; Zheng LI ; Liang ZHANG ; Chong ZHANG ; Hongxing WANG
Chinese Journal of Behavioral Medicine and Brain Science 2014;23(9):848-850
Objective To test the reliability and validity of self-management instrument for person with schizophrenia.Methods The instrument was psychometrically tested by using 396 people with schizophrenia among 8 mental health service centers in Beijing.The instrument was test by internal consistency analysis,test-retest reliability,exploratory factor analysis,confirmed factor analysis,known-groups validity.Results The Cronbach α coefficient of instrument was 0.96,Pearson coefficient was 0.791.Factor analysis of the instrument resulted in six factors:medication compliance,medication management,symptom management,maintain daily life and social functioning,manage health recourse and support,and self-efficacy.The six-factor solution accounted for 61.70% of the total variance.The results also showed that the newly developed instrument was positively correlated with PIH.The results also demonstrated that the instrument could discriminate patients' self-management ability according to their living status,work status,education background,and financial burden.Conclusion The newly developed instrument has adequate psychometric properties and may be useful in intervention program and assessing self-management in individuals with schizophrenia.
5.Effect of SKy bone expander system by percutaneous osteoplasty in treatment calcaneal fracture
Haitao CHEN ; Chaohua YANG ; Qunying LIANG ; Qizhong LI ; Haiou GUO ; Guocong DU ; Jiexiong OU
Chinese Journal of Primary Medicine and Pharmacy 2013;20(14):2092-2094
Objective To explore the clinical effect of percutaneous osteoplasty with SKy bone expander system in the treatment of calcaneal fracture.Methods 63 feet of 55 patients with calcaneal fractures were involved in this study.According to Sanders fracture classification including 38 feet of Sanders Ⅱ,18 feet of Sanders Ⅲ,7 feet of Sanders Ⅳ.There were 6 to 16 days interval between the injuries and the surgeries.The patients were treated by percutaneous osteoplasty with the SKy bone expander system.The standard of operation was the satisfaction of reduction and Bohler's and Gissane's angles under X-ray.Results All of 63 feet of 55 patients were followed up for average 22 months.According to the criterion of therapeutic effect,the results were as follows:excellent in 30 cases,good in 26 cases,fair in 7cases,and no poor case.The excellent and good rate was 88.9%.Conclusion Percutaneous osteoplasty with SKy bone expander system in the treatment of calcaneal fracture,especially in reduction and fixation of Sanders type Ⅱ and Sanders type Ⅲ,can recover Bohler's and Gissane's angles,significantly shorten the duration of illness,and has fast recovery and can possess satisfactory curative effect,and it is worth popularizing.

Result Analysis
Print
Save
E-mail