1.Comparative study of total knee arthroplasty assisted by robot and remote sensing navigation system
Hai TANG ; Hong-Mei ZHANG ; Peng-Cheng SHAN ; Pei-Yan HU ; Lin JING ; Qi YAN ; Yuan-Yuan LI ; Xin-Yue WANG ; Si-Ye LIU ; Ming-Jiang HE
China Journal of Orthopaedics and Traumatology 2024;37(9):862-869
Objective To compare clinical efficacy of robot-assisted(RA)and remote sensing navigation alignment(RSNA)system-assisted total knee arthroplasty(TKA).Methods From March 2023 to June 2023,60 patients who underwent the first unilateral TKA due to severe knee osteoarthritis(KOA)were admitted and divided into RSNA group and RA group according to different treatment methods,with 30 patients in each group.There were 5 males and 25 females in RSNA group,aged from 56 to 81 years old with an average of(66.33±7.16)years old;body mass index(BM1)ranged from 19.87 to 38.54 kg·m-2 with an average of(28.40±6.18)kg·m-2;the courses of disease ranged from 5 to 36 months with an average of(18.20±8.98)months;RSNA system was used to assist the positioning of osteotomy.There were 7 males and 23 females in RA group,aged from 55 to 82 years old with an average of(67.83±8.61)years old;BMI ranged from 19.67 to 37.25 kg·m-2 with an aver-age of(28.01±4.89)kg·m-2;the courses of disease ranged from 3 to 33 months with an average of(17.93±9.20)months;RA was performed.Operation time,incision length,latent blood loss at 2 weeks after operation and incidence of lower extremity thrombosis were compared between two groups.Hip-knee ankle angle(HKAA),HKAA deviation,lateral distal femoral angle(LDFA),medial proximal tibial angle(MPTA)and posterior tibial slope(PTS)were compared between two groups;Western Ontario McMaster Universities Osteoarthritis Index(WOMAC)and Knee Society score(KSS)were used to evaluate functional recovery before operation,3 and 6 months after operation.Results The operation was performed successfully in both groups,and there were no serious complications such as vascular and nerve injury during operation.The wound healed well at stage Ⅰafter operation,and the follow-up time was 6 months.The operation time,latent blood loss at 2 weeks after operation and inci-sion length in RSNA group were(94.35±5.75)min,(130.54±17.53)mland(14.73±2.14)cm,respectively;while(102.57±6.88)min,(146.33±19.47)ml and(16.78±2.32)cm in RA group,respectively.RSNA group was better than RA group(P<0.05).No deep vein thrombosis occurred in both groups at 2 weeks after operation,5 patients occurred intermuscular vein throm-bosisin in RSNA group and 8 patients in RA group,the difference was not statistically significant(P>0.05).In RSNA group,HKAA,LDFA and MPTA were(173.00±5.54)°,(86.96±3.45)°,(82.79±3.35)° before operation,and(178.34±1.85)°,(89.92±0.42)°,(89.84±0.73)° at 1 week after operation,respectively.In RA group,HKAA,LDFA and MPTA were(173.31±6.48)°,(87.15±3.40)° and(82.99±3.05)° before operation,and(178.52±1.79)°,(90.03±0.39)° and(90.15±0.47)° at 1 week after operation,respectively.HKAA,LDFA and MPTA were significantly improved in both groups at 1 week after oper-ation(P<0.05).There were no significant difference in HKAA,LDFA,MPTA and PTS between two groups before operation and 1 week after operation(P>0.05).There was no significant difference in deviation distribution of HKAA at 1 week after op-eration(x2=2.61 1,P=0.456).There were no significant difference in WOMAC and KSS between two groups before operation,3 and 6 months after operation(P>0.05),and postoperative WOMAC and KSS at 3 and 6 months between two groups were im-proved compared with those before operation(P<0.05).Conclusion Both RA and RSNA system assisted TKA could obtain ac-curate osteotomy,RA has higher surgical accuracy,RSNA system assisted operation has less trauma,and operation is simpler.
2.Application of remote sensing navigation system in total knee arthroplasty
Yuan-Yuan LI ; Ming-Jiang HE ; Peng-Cheng SHAN ; Pei-Yan HU ; Lin JING ; Qi YAN ; Hai TANG ; Xin-Yue WANG ; Si-Ye LIU ; Hong-Mei ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(9):878-885
Objective To explore clinical accuracy of remote sensing navigation alignment(RSNA)system in total knee arthroplasty(TKA)and its influence on postoperative clinical efficacy.Methods From May 2021 to May 2022,60 knee os-teoarthritis(KOA)patients with Kellgren-Lawrence(K-L)grade Ⅲ to Ⅳ treated by unilateral primary TKA were selected and divided into RSNA group and traditional operation group according to treatment methods,and 30 patients in each group.There were 6 males and 24 females in RSNA group,aged from 55 to 86 years old with an average of(68.06±8.23)years old;body mass index(BMI)ranged from 22.15 to 34.58 kg·m-2 with an average of(28.20±3.01)kg·m-2;the courses of disease ranged from 2 to 60 months with an average of(18.80±14.80)months;13 patients with grade Ⅲ and 17 patients with grade Ⅳaccording to K-L grading.In traditional operation group,there were 8 males and 22 females,aged from 57 to 85 years old with an average of(67.26±6.32)years old;BMI ranged from 23.94 to 34.55 kg·m-2 with an average of(27.49±2.32)kg·m-2;the courses of disease ranged from 3 to 60 months with an average of(21.30±16.44)months;14 patients with grade Ⅲ and 16 pa-tients with grade Ⅳ according to K-L grading.Western Ontario and McMaster Universities(WOMAC)osteoarthritis index and Knee Society score(KSS)were used to evaluate functional recovery of patients.Hip-knee-ankle angle(HKAA),distal femoral valgus angle(FVA)and distal fermoral flexion angle(DFFA)were measured before operation.HKAA and HKAA deviation angle were measured at 1 week after operation,and defective rate of lower limb force line,femur prosthesis valgus angle(FP-VA)and femoral prosthesis flexion angle(FPFA),respectively,were calculated.Results There were no serious complications such as vascular and nerve injury during operation,and wound healed at stage Ⅰ.Both groups were followed up for 6 months.There were no significant difference in WOMAC index,KSS,HKAA,FVA and DFFA between two groups before operation(P>0.05).The force line defect rate,HKAA,HKAA deviation angle,FPVA deviation angle and FPFA of RSNA group were 6.7%,(178.74±1.56)°,(1.25±1.56)°,(1.84±0.16)° and(4.85±2.46)°,respectively;while in traditional operation group were 20%,(176.73±3.46)°,(3.27±3.46)°,(2.44±0.26)°,(6.60±1.86)°;the difference between two groups were statistically sig-nificant(P<0.05).There were no significant difference in WOMAC index and KSS between two groups at 3 and 6 months after operation(P>0.05).Conclusion RSNA system could reduce defective rate of lower limb force line,FPVA deviation angle and FPFA after TKA,which is more accurate and easy to operate than traditional intramedullary localization surgery while ensuring postoperative efficacy.
3.Mechanisms of hypertension inducing erectile dysfunction via the cGMP/PKG signaling pathway:An investigation using transcriptomics and network pharmacology
Jun-Long FENG ; Hai-Song LI ; Song SUN ; Bin WANG ; Hua-Nan ZHANG ; Zi-Xiang GAO ; Peng-Ming MAO ; Long-Ji SUN ; Nian-Wen HUANG ; Ji-Sheng WANG
National Journal of Andrology 2024;30(9):771-781
Objective:To explore the mechanism of hypertension inducing erectile dysfunction(ED)using transcriptomics and network pharmacology.Methods:We randomly divided 12 male rats with spontaneous hypertension(SHT)into an L-arginine(LA)group(n=6)and an SHT model control(MC)group(n=6),took another 6 Wistar Kyoto male rats as normal controls(NC),and treated the animals in the LA group by intraperitoneal injection of LA at 400 mg/kg and those in the latter two groups with physio-logical saline,once a day,all for 7 days.Then we observed the blood pressure and penile erection of the rats,and determined the ex-pressions of the cGMP/PKG signaling pathway-related proteins and mRNAs in different groups using ELISA,Western blot and RT-qPCR.Results:Transcriptomics combined with network pharmacology showed that the cGMP/PKG signaling pathway played a key role in hypertension-induced ED.In vivo animal experiments revealed a significantly lower frequency of penile erections in the MC than in the NC group(1.33±0.52 vs 2.67±0.51,P<0.05).The protein expressions of eNOS,PKG and sGC were markedly de-creased in the model controls compared with those the normal controls(P<0.05),but remarkably upregulated in the LA group com-pared with those in the MC group(P<0.05).Conclusion:Hypertension decreases the expressions of eNOS,NO,sGC,cGMP and PKG proteins and the level of testosterone by inhibiting the cGMP/PKG signaling pathway,which consequently suppresses the relaxa-tion of the penile vascular smooth muscle and reduces erectile function.
4.Quality standard for Zhujieshen Formula Granules based on standard decoction
Chen-Hui YE ; Hai-Ming TANG ; Cheng-Fu YUAN ; Jia-Long GUO ; Ji-Hong ZHANG ; Ding YUAN ; Yu-Min HE
Chinese Traditional Patent Medicine 2024;46(9):2863-2869
AIM To establish the quality standard of the zhujieshen Formula Granules based on standard decoction.METHODS The contents and transfer rates of ginsenoside Ro and chikusetsu saponin Ⅳa in standard decoction and formula granules were determined by HPLC,after which the transfer rates were calculated.The HPLC characteristic chromatograms of standard decoctions were established,after which cluster analysis and principal component analysis were adopted.Then the HPLC characteristic chromatograms of formula granules were established.RESULTS Nine common peaks were found in the HPLC characteristic chromatograms of seventeen batches of standard decoctions with the similarities of more than 0.9(except for S6,S12),which were clustered into two categories,and the accumulative variance contribution rate of three principal components reached 86.7%.The contents of ginsenoside Ro in three batches of formula granules were 83.1-88.6 mg/g,and the transfer rates were 53.1%-55.5%.The contents of chikusetsusaponin Ⅳa were 14.8-15.0 mg/g,and the transfer rates were 47.4%-48.1%.Nine common peaks were found in the HPLC characteristic chromatograms of three batches of formula granules with the similarities of 0.998,0.998 and 0.999,respectively.CONCLUSION This reasonable and reliable method can comprehensively evaluate the quality of Zhujieshen Formula Granules,and provide a reference for the quality control.
5.SWOT analysis-based research on development path of Shanghai's medical device industry
Hai-Yan LUO ; Yi-Han YANG ; Pei-Ming ZHANG
Chinese Medical Equipment Journal 2024;45(6):77-82
The development status quo of Shanghai's medical device industry was described.By using SWOT analysis method the influencing factors of the industry were analyzed and the key influencing factors were determined.A SWOT strategy matrix was constructed with considerations on the strengths,weaknesses,opportunities and threats of the key influencing factors.Some suggestions were put forward based on the SWOT strategy matrix and weak links of Shanghai's medical device industry to promote the development of the industry,and references were provided for the development of Shanghai's medical device industry.[Chinese Medical Equipment Journal,2024,45(6):77-82]
6.Numerical simulation study for mechanical behavior of cancellous bone under interaction of parameters of low-magnitude high-frequency vibration
Ming-Zhi LI ; Hai-Ying LIU ; Sheng-Gang LI ; Chun-Qiu ZHANG
Chinese Medical Equipment Journal 2024;45(7):17-23
Objective To explore the mechanical behavior of cancellous bone under the interaction of whole-body low-magnitude high-frequency vibration(LMHFV)parameters,in order to provide theoretical guidance for the clinical treatment of disuse osteoporosis.Methods A three-dimensional reconstruction model was established for the cancellous bone of the mid femur by Mimics software,which was then imported into Comsol software to form a three-dimensional fluid-solid coupling finite element model.Twelve scenarios with the vibration acceleration amplitude(a)being 0.015×g,0.02×g,0.03×g and vibration frequency(f)being 30,45,60 and 100 Hz were set up for the simulation study to analyze the distribution rules of the hydrodynamic microenvironment,the stresses and the deformation displacements of cancellous bone under the interaction of LMHFV parameters.Results The bone marrow flow velocity on the surface of trabeculae and deformation displacement of bone matrix increased with the rising of a and decreased with the growing of f.Trabeculae gained high mean values of deformation displacement in case of the vibration scenario(0.015×g/0.02×g/0.03×g,30 Hz),and had high von Mises stress when LMHFV parameters were restricted within(0.02×g to 0.03×g,30 Hz to 35 Hz).Conclusion Whole-body LMHFV significantly improves the force and hydrodynamic environment of cancellous bone,and force-mediated osteoblast bioactivity can be enhanced by rationally modulating LMHFV parameters during clinical processes so as to promote osteogenesis.[Chinese Medical Equipment Journal,2024,45(7):17-23]
7.Modal testing study of three-axis manned centrifuge under elastic boundary conditions
Hai-Xia WANG ; Ke JIANG ; Zhao JIN ; Yi WANG ; Li-Hui ZHANG ; Yan XU ; Cong WANG ; Ming-Hao YANG ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Yuan-Jing ZHENG ; Bao-Hui LI
Chinese Medical Equipment Journal 2024;45(8):38-43
Objective To explore the modal testing method for the three-axis manned centrifuge under elastic boundary conditions with considerations on its complicated structure and high rotational inertia.Methods Modal testing was carried out with a three-axis manned centrifuge under elastic boundary conditions as the subject and a force hammer as the excitation source according to GJB 2706A-2008 Modal tests method for spacecraft and GB/T 11349.3-1992 Experimental determination of mechnical mobility measurements using impact excitation.Four times of hammering were carried out at each excitation position,and the data of the four times of hammering underwent linear average computation.Data acquisition was implemented with a three-axis accelerometer and a 64-channel data collector,and the modal data were analyzed using a frequency response function based on the Test.Lab modal test and analysis software.Results The coherence coefficient of the excitation signal was not lower than 0.8 in the 30 Hz band;the first three orders of the system's intrinsic vibrations were all torsional vibrations,with the frequencies of 9.15,15.66 and 19.22 Hz,respectively;the first order frequency of the system was about 9.15 Hz for both Z18 and Z21 excitation positions,and each of the second and third order frequencies similar situations were observed for also had a roughly equal value for the two excitation positions.Conclusion The force hammer testing method is applicable for the modal testing of the three-axis manned centrifuge,ensuring equipment safety and subject comfort.Referen-ces are provided for the following structural optimization design.[Chinese Medical Equipment Journal,2024,45(8):38-43]
8.Design and implementation of high precision ear pulse wave physiological signal detection device for human centrifuge training
Ke JIANG ; Ming-Hao YANG ; Hai-Xia WANG ; Bao-Hui LI ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Zhong-Zheng GUO ; Xiao-Yang WEI
Chinese Medical Equipment Journal 2024;45(9):35-40
Objective To design and implement a high-precision ear pulse wave physiological signal detection device for human centrifuge training to solve the problems in measurement and calibration of pilot ear pulse wave signal during human centrifuge training.Methods The high-precision ear pulse wave physiological signal detection device was composed of an ear pulse wave acquisition sensor,a signal acquisition and control unit and a host signal processing module.The ear pulse wave acquisition sensor had an ear-clip-like shape and consisted of an outer shell,an inner shell and an elastic steel plate;the signal acquisition and control unit was made up of an power supply module,a constant voltage module for the light source,a signal acquisition module,a master control module and a data transmission module,which had its software developed with an embedded system;the host signal processing module divided the signal processing into 2 phases of signal pre-processing and pulse wave signal monitoring and display.The detection performance of the device was verified by using a physiological electrical signal calibrator to test the ear pulse wave signals detected with the device;the effectiveness and stability of the device were validated by implementing human centrifuge training experiments with different loads.Results The voltage measurement error,amplitude-frequency characteristics and common mode rejection ratio detected by this device were all within the permitted ranges of JJG 760-2003 Verification Regulation for Electro Cardiac Monitor and JJG 954-2019 Verification Regulation of Digital Electroencephalographs;the device was capable of detecting the ear pulse wave signals of pilot during human centrifuge training in real time with little interference from motion and stable signal quality.Conclusion The device can accurately clarify the changes in the amplitude of the pilot's ear pulse wave during human centrifuge training and effectively reflect the changes in the pilot's cerebral blood flow under positive acceleration.[Chinese Medical Equipment Journal,2024,45(9):35-40]
9.Fangji Fuling Decoction Alleviates Sepsis by Blocking MAPK14/FOXO3A Signaling Pathway.
Yi WANG ; Ming-Qi CHEN ; Lin-Feng DAI ; Hai-Dong ZHANG ; Xing WANG
Chinese journal of integrative medicine 2024;30(3):230-242
OBJECTIVE:
To examine the therapeutic effect of Fangji Fuling Decoction (FFD) on sepsis through network pharmacological analysis combined with in vitro and in vivo experiments.
METHODS:
A sepsis mouse model was constructed through intraperitoneal injection of 20 mg/kg lipopolysaccharide (LPS). RAW264.7 cells were stimulated by 250 ng/mL LPS to establish an in vitro cell model. Network pharmacology analysis identified the key molecular pathway associated with FFD in sepsis. Through ectopic expression and depletion experiments, the effect of FFD on multiple organ damage in septic mice, as well as on cell proliferation and apoptosis in relation to the mitogen-activated protein kinase 14/Forkhead Box O 3A (MAPK14/FOXO3A) signaling pathway, was analyzed.
RESULTS:
FFD reduced organ damage and inflammation in LPS-induced septic mice and suppressed LPS-induced macrophage apoptosis and inflammation in vitro (P<0.05). Network pharmacology analysis showed that FFD could regulate the MAPK14/FOXO signaling pathway during sepsis. As confirmed by in vitro cell experiments, FFD inhibited the MAPK14 signaling pathway or FOXO3A expression to relieve LPS-induced macrophage apoptosis and inflammation (P<0.05). Furthermore, FFD inhibited the MAPK14/FOXO3A signaling pathway to inhibit LPS-induced macrophage apoptosis in the lung tissue of septic mice (P<0.05).
CONCLUSION
FFD could ameliorate the LPS-induced inflammatory response in septic mice by inhibiting the MAPK14/FOXO3A signaling pathway.
Mice
;
Animals
;
Mitogen-Activated Protein Kinase 14/metabolism*
;
Wolfiporia
;
Lipopolysaccharides/pharmacology*
;
Sepsis/complications*
;
Signal Transduction
;
Inflammation/drug therapy*
;
Oxygen Radioisotopes
10.Clinical trial of Morinda officinalis oligosaccharides in the continuation treatment of adults with mild and moderate depression
Shu-Zhe ZHOU ; Zu-Cheng HAN ; Xiu-Zhen WANG ; Yan-Qing CHEN ; Ya-Ling HU ; Xue-Qin YU ; Bin-Hong WANG ; Guo-Zhen FAN ; Hong SANG ; Ying HAI ; Zhi-Jie JIA ; Zhan-Min WANG ; Yan WEI ; Jian-Guo ZHU ; Xue-Qin SONG ; Zhi-Dong LIU ; Li KUANG ; Hong-Ming WANG ; Feng TIAN ; Yu-Xin LI ; Ling ZHANG ; Hai LIN ; Bin WU ; Chao-Ying WANG ; Chang LIU ; Jia-Fan SUN ; Shao-Xiao YAN ; Jun LIU ; Shou-Fu XIE ; Mao-Sheng FANG ; Wei-Feng MI ; Hong-Yan ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(6):815-819
Objective To observe the efficacy and safety of Morinda officinalis oligosaccharides in the continuation treatment of mild and moderate depression.Methods An open,single-arm,multi-center design was adopted in our study.Adult patients with mild and moderate depression who had received acute treatment of Morinda officinalis oligosaccharides were enrolled and continue to receive Morinda officinalis oligosaccharides capsules for 24 weeks,the dose remained unchanged during continuation treatment.The remission rate,recurrence rate,recurrence time,and the change from baseline to endpoint of Hamilton Depression Scale(HAMD),Hamilton Anxiety Scale(HAMA),Clinical Global Impression-Severity(CGI-S)and Arizona Sexual Experience Scale(ASEX)were evaluated.The incidence of treatment-related adverse events was reported.Results The scores of HAMD-17 at baseline and after treatment were 6.60±1.87 and 5.85±4.18,scores of HAMA were 6.36±3.02 and 4.93±3.09,scores of CGI-S were 1.49±0.56 and 1.29±0.81,scores of ASEX were 15.92±4.72 and 15.57±5.26,with significant difference(P<0.05).After continuation treatment,the remission rate was 54.59%(202 cases/370 cases),and the recurrence rate was 6.49%(24 cases/370 cases),the recurrence time was(64.67±42.47)days.The incidence of treatment-related adverse events was 15.35%(64 cases/417 cases).Conclusion Morinda officinalis oligosaccharides capsules can be effectively used for the continuation treatment of mild and moderate depression,and are well tolerated and safe.

Result Analysis
Print
Save
E-mail