1.Study on the effect of different administration regimens of iprrazole enteric-coated tablets on inhibiting gastric acid secretion
Ting-Yuan PANG ; Zhi WANG ; Zi-Shu HU ; Zi-Han SHEN ; Yue-Qi WANG ; Ya-Qian CHEN ; Xue-Bing QIAN ; Jin-Ying LIANG ; Liang-Ying YI ; Jun-Long LI ; Zhi-Hui HAN ; Guo-Ping ZHONG ; Guo-Hua CHENG ; Hai-Tang HU
The Chinese Journal of Clinical Pharmacology 2024;40(1):92-96
Objective To compare the effects of 20 mg qd and 10 mg bidadministration of iprrazole enteric-coated tablets on the control of gastric acid in healthy subjects.Methods A randomized,single-center,parallel controlled trial was designed to include 8 healthy subjects.Randomly divided into 2 groups,20 mg qd administration group:20 mg enteric-coated tablets of iprrazole in the morning;10 mg bid administration group:10 mg enteric-coated tablets of iprrazole in the morning and 10 mg in the evening.The pH values in the stomach of the subjects before and 24 h after administration were monitored by pH meter.The plasma concentration of iprazole after administration was determined by HPLC-MS/MS.The main pharmacokinetic parameters were calculated by Phoenix WinNonlin(V8.0)software.Results The PK parameters of iprrazole enteric-coated tablets and reference preparations in fasting group were as follows:The Cmax of 20 mg qd group and 10 mg bid group were(595.75±131.15)and(283.50±96.98)ng·mL-1;AUC0-t were(5 531.94±784.35)and(4 686.67±898.23)h·ng·mL-1;AUC0-∞ were(6 003.19±538.59)and(7 361.48±1 816.77)h·ng·mL-1,respectively.The mean time percentage of gastric pH>3 after 20 mg qd and 10 mg bid were 82.64%and 61.92%,and the median gastric pH within 24 h were 6.25±1.49 and 3.53±2.05,respectively.The mean gastric pH values within 24 h were 5.71±1.36 and 4.23±1.45,respectively.The correlation analysis of pharmacokinetic/pharmacodynamics showed that there was no significant correlation between the peak concentration of drug in plasma and the inhibitory effect of acid.Conclusion Compared with the 20 mg qd group and the 10 mg bid group,the acid inhibition effect is better,the administration times are less,and the safety of the two administration regimes is good.
2.Mechanism and research progress of S100A8/A9 in the microenvironment before high-risk tumor metastasis
Hai-Xia MING ; Zhao-Hua LIU ; Yan-Jun WANG ; Ming SHEN ; Yan-Wen CHEN ; Yang LI ; Ling-Ling YANG ; Qian-Kun LIANG
The Chinese Journal of Clinical Pharmacology 2024;40(13):1991-1995
S100 calc-binding protein A8/A9(S100A8/A9)can induce the migration of primary tumor cells to distant target organs by binding multiple channel proteins,promote the formation of tumor metastasis microenvironment,and play an important role in the immune and inflammatory response of the body.It provides a new target and idea for the prevention and treatment of tumor metastasis and invasion.This paper mainly reviewed the expression and mechanism of S100A8/A9 on related channel proteins in a variety of high incidence tumors,in order to provide a new strategy for tumor prevention,diagnosis and treatment.
3.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.
4.Effects of hypericin on bone metabolism,biomechanics and mechanism of osteoporosis in rats with chronic obstructive pulmonary disease
Ming-Xia SHEN ; Wen-Jun DING ; Hai-Bin XIE ; Yun ZHANG ; Xing-Xing YANG ; Yong-Rui GAO
The Chinese Journal of Clinical Pharmacology 2024;40(20):3003-3007
Objective To investigate the effect and mechanism of hypericin on osteoporosis(OP)in rats with chronic obstructive pulmonary disease(COPD).Methods COPD combined with OP rat model was established by cigarette combined with bacteria.The rats were randomly divided into control group,model group(COPD combined with OP model was constructed),experimental-L group(50 mg·kg-1 hypericin was given by intragastric administration after constructing COPD combined with OP model),experimental-H group(100 mg·kg-1 hypericin was given intragastric administration after constructing COPD combined with OP model),positive group(subcutaneous injection of 16 U·kg-1 salmon calcitonin after constructing COPD combined with OP model);each group was given 12 rats for 90 days.The lung function of rats was detected by pulmonary function apparatus;bone mineral density(BMD)was detected by micro-computed tomography(CT);serum bone metabolism and inflammatory factors were detected by enzyme-linked immunosorbent assay(ELISA);Western blot assay was used to detect the relevant indicators of the pathway.Results The levels of forced vital capacity(FVC)in control group,model group,experimental-H group and positive group were(10.42±1.40),(4.10±0.60),(6.75±0.37),(4.18±0.33)mL,respectively;BMD levels were(0.31±0.04),(0.12±0.02),(0.28±0.03),(0.29±0.04)g·mm-3,respectively;bone alkaline phosphatase(BALP)levels were(200.04±20.03),(80.80±6.00),(148.16±14.23),(173.97±23.55)U·L1,respectively;interleukin-1β(IL-1β)levels were(122.60±8.70),(695.59±74.84),(422.41±44.86),(527.90±39.36)pg·mL-1,respectively;phosphorylated p38 mitogen-activated protein kinase(p-P38)protein expression levels were 0.99±0.11,0.36±0.05,0.79±0.08,0.36±0.04,respectively.Compared with the control group,the above indexes in the model group had statistical significance(all P<0.05);the above indexes in experimental-H group were significantly different from those in model group(all P<0.05).Conclusion Hypericin can inhibit inflammatory response,improve bone metabolism and biomechanics.
5.Comparison of the efficacy of TiRobot orthopaedic robot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures
Xing-Long ZHAO ; Jian-Jun SHEN ; Kang-Hu FENG ; Zhi-Wei CHEN ; Yuan-Long SI ; Xuan ZHANG ; Guan-De WANG ; Xiang HAI
China Journal of Orthopaedics and Traumatology 2024;37(2):129-134
Objective To compare the effectiveness of TiRobot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures.Methods A retrospective analysis was conducted on 72 patients with unstable femoral neck fractures who were treated with percutaneous cannulated screw fixation assisted with TiRobot Orthopaedic robot from December 2019 to April 2021.Among them,37 patients were treated with F screw internal fixa-tion,including 16 males and 21 females,aged47 to 64years old with an average of(53.87±5.28)years old;According to Pauwels classification,there were 1 case of type Ⅰ,19 cases of type Ⅱ,17 cases of type Ⅲ;8 cases of combined medical diseases;17 cases of falling,8 cases of traffic accident and 12 cases of falling from height;The time from injury to operation was 29 to 49 hours with average of(35.00±7.34)hours.Another 35 cases used internal fixation with an inverted triangle parallel nail,including 13 males and 22 females with an average age of 46 to 63 years old(52.36±5.05)years old;According to the Pauwels injury classifi-cation:there were 2 cases of type Ⅰ,21 cases of type Ⅱ,12 cases of type Ⅲ;6 cases of medical diseases,15 cases of falling in-jury,9 cases of traffic accident,11 cases of falling injury;The time from injury to operation was 30 to 45 hours with an average of(33.00±6.83)h.The intraoperative blood loss,operation time,intraoperative fluoroscopy times,follow-up time,fracture healing time,postoperative complications were observed and compared between the two groups.The hip joint function was e-valuated by Harris score at 6 months and 12 months after operation.Results There was no significant difference in operation time,intraoperative blood loss,intraoperative fluoroscopy times and other intraoperative data between two groups(P>0.05).Both groups were followed up regularly,and the follow-up time was 12 to 16 months.The fracture healing time and Harris score of the F screw internal fixation group were better than those of the inverted triangle parallel nail internal fixation group(P<0.05).There was 1 case of femoral neck shortening in the F screw internal fixation group,1 case of nonunion,1 case of nail withdrawal,and 1 case of lower extremity deep vein thrombosis in the inverted triangle internal fixation group.The incidence of complications in the F screw internal fixation group was lower than that in the inverted triangle parallel nail internal fixation group(P<0.05).Conclusion Percutaneous cannulated F screw technique using Tirobot navigation positioning system is a safe and effective treatment for patients with unstable femoral neck fractures.It can significantly shorten the fracture healing time,reduce the incidence of postoperative complications,significantly improve hip joint function,and improve the quality of life.
6.Comparison of the posterior hemipelvectomy of the greater trochanter approach with the standard Kocher-Langen-beck approach in the treatment of posterior acetabulum wall fractures
Jin ZHANG ; Jian-Jun SHEN ; Xiang HAI ; Chuan-Yuan LIU ; Wen-Jie ZHOU ; Zhi-Wei CHEN
China Journal of Orthopaedics and Traumatology 2024;37(8):786-792
Objective To compare the clinical efficacy of the posterior hemipelvectomy of the greater trochanter approach with the standard Kocher-Langenbeck(K-L)approach in the treatment of posterior acetabulum wall fractures and to explore a more optimal approach for the treatment of posterior acetabulum wall fractures.Methods Total of 26 patients with posterior ac-etabulum wall fractures were retrospectively analysed and divided into two groups:the posterior hemipelvectomy of the greater trochanter group(test group)and the standard K-L approach group(control group).In the test group,there were 24 patients including 16 males and 8 females with an average age of(42.00±4.52)years old,the time of injury to surgery was(6.75±1.15)d.In the control group,there were 23 patients including 16 males and 7 females with an average age of(41.00±5.82)years old,the time of injury to surgery was(7.09±1.20)days.The total hospital stay,length of incision,operation time,intraoperative bleeding,postoperative drainage,discharge,fracture reduction quality(Matta criteria),hip abduction muscle strength,hip func-tion(Merle d'Aubigne-Postel score),postoperative complications and the incidence of ectopic ossification were compared.Results All cases were followed up for 6 months.There was no significant difference in incision length,intraoperative bleeding and postoperative drainage between two groups(P>0.05).However,the operation time of the test group was shorter than that of the control group(P<0.05).There was no statistically significant difference in fracture reduction and hip function between two groups(P>0.05).The hip abduction muscle strength of test group was better than that of control group(P<0.05).In addition,there was no significant difference in the incidence of postoperative complications and heterotopic ossification between two groups(P>0.05).Conclusion Compared with the standard K-L approach,the posterior hemipelvectomy of the greater trochanter approach can shorten the operative time,has better recovery of the postoperative hip abduction muscle strength,ex-poses the view of the fracture involving the more comminuted posterior acetabulum wall or the fracture of the roof of the socket,improved the rate of fracture anatomical repositioning,provides a new idea for the clinical treatment of posterior acetabulum wall fractures,and allows patients to perform functional exercises at an early stage.
7.Pulsed thulium laser combined with pulsed thulium laser injection for the treatment of failed urethral anastomosis
Jian LI ; Da-Chao ZHENG ; Hai-Jun YAO ; Jin HUANG ; Zhong-Lin CAI ; Zhi-Kang CAI ; Yan-Ting SHEN ; Zhong WANG
National Journal of Andrology 2024;30(5):419-423
Objective:To investigate the clinical effect of pulsed thulium laser(PTL)combined with triamcinolone acetonide injection in the treatment of failed posterior urethral anastomosis(FPUA).Methods:This retrospective study included 35 male pa-tients treated in Gongli Hospital for failed posterior urethral anastomosis from January 2018 to December 2023.All the patients under-went direct-vision internal urethrotomy(DVIU)with transurethral PTL(the PTL group,n=15)or transurethral plasma(the TUP group,n=20),and all received intralesional injection of triamcinolone acetonide.We followed up the patients for a median of 21 months,recorded the age,length of urethral stricture,operation time,pre-and post-operative maximum urinary flow rate(Qmax),postoperative complications and recurrence of urethral stricture,and compared the data obtained between the two groups.Results:All the patients smoothly completed the treatment procedures.No statistically significant differences were observed in the age,length of urethral stricture,operation time and postoperative complications between the two groups(P>0.05).The median follow-up time for the thulium laser group and plasma group was 21.0 months(IQR 16.0-24.0)and 21.0 months(IQR 17.0-25.0),respectively,with a statistically significant difference observed in the maximum urine flow rate before and after surgery at the 12-month mark(P<0.01).No significant disparity was found in terms of relapse-free survival between the two groups(P=0.398)Conclusion:Pulsed thulium laser combined with triamcinolone acetonide injection can effectively maintain a short-term cicatricial stability of the ure-thral stricture and satisfactory urethral patency,obviously superior to plasmotomy as a remedial treatment of urethral stricture after failed posterior urethral anastomosis.
8.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
10.Establishment and validation of a nomogram-based predictive model for idiopathic aldosteronism.
Juan FEI ; Hang SHEN ; Shu Min YANG ; Zhi Peng DU ; Jin Bo HU ; Hai Bin WANG ; Gui Jun QIN ; Hong Fei JI ; Qi Fu LI ; Ying SONG
Chinese Journal of Internal Medicine 2023;62(6):693-699
Objective: To establish and validate a nomogram-based predictive model for idiopathic hyperaldosteronism (IHA). Methods: This cross-sectional study was conducted with the collected clinical and biochemical data of patients with primary aldosteronism (PA) including 249 patients with unilateral primary aldosteronism (UPA) and 107 patients with IHA, who were treated at the Department of Endocrinology of the First Affiliated Hospital of Chongqing Medical University from November 2013 to November 2022. Plasma aldosterone concentration (PAC) and plasma renin concentration (PRC) were measured by chemiluminescence. Stepwise regression analysis was applied to select the key predictors of IHA, and a nomogram-based scoring model was developed. The model was validated in another external independent cohort of patients with PA including 62 patients with UPA and 43 patients with IHA, who were diagnosed at the Department of Endocrinology, First Affiliated Hospital of Zhengzhou University. An independent-sample t test, Mann-Whitney U test, and χ2 test were used for statistical analysis. Results: In the training cohort, in comparison with the UPA group, the IHA group showed a higher serum potassium level [M(Q1, Q3), 3.4 (3.1, 3.8) mmol/L vs. 2.7 (2.1, 3.1) mmol/L] and higher PRC [4.0 (2.1, 8.2) mU/L vs. 1.5 (0.6, 3.4) mU/L] and a lower PAC post-saline infusion test (SIT) [305 (222, 416) pmol/L vs. 720 (443, 1 136) pmol/L] and a lower rate of unilateral adrenal nodules [33.6% (36/107) vs. 81.1% (202/249)]; the intergroup differences in these measurements were statistically significant (all P<0.001). Serum potassium level, PRC, PAC post-SIT, and the rate of unilateral adrenal nodules showed similar performance in the IHA group in the validation cohort. After stepwise regression analysis for all significant variables in the training cohort, a scoring model based on a nomogram was constructed, and the predictive parameters included the rate of unilateral adrenal nodules, serum potassium concentration, PAC post-SIT, and PRC in the standing position. When the total score was ≥14, the model showed a sensitivity of 0.65 and specificity of 0.90 in the training cohort and a sensitivity of 0.56 and specificity of 1.00 in the validation cohort. Conclusion: The nomogram was used to successfully develop a model for prediction of IHA that could facilitate selection of patients with IHA who required medication directly.
Humans
;
Hyperaldosteronism/diagnosis*
;
Nomograms
;
Hypertension
;
Cross-Sectional Studies
;
Aldosterone
;
Saline Solution
;
Renin
;
Potassium

Result Analysis
Print
Save
E-mail