1.A Study of Flow Sorting Lymphocyte Subsets to Detect Epstein-Barr Virus Reactivation in Patients with Hematological Malignancies.
Hui-Ying LI ; Shen-Hao LIU ; Fang-Tong LIU ; Kai-Wen TAN ; Zi-Hao WANG ; Han-Yu CAO ; Si-Man HUANG ; Chao-Ling WAN ; Hai-Ping DAI ; Sheng-Li XUE ; Lian BAI
Journal of Experimental Hematology 2025;33(5):1468-1475
OBJECTIVE:
To analyze the Epstein-Barr virus (EBV) load in different lymphocyte subsets, as well as clinical characteristics and outcomes in patients with hematologic malignancies experiencing EBV reactivation.
METHODS:
Peripheral blood samples from patients were collected. B, T, and NK cells were isolated sorting with magnetic beads by flow cytometry. The EBV load in each subset was quantitated by real-time quantitative polymerase chain reaction (RT-qPCR). Clinical data were colleted from electronic medical records. Survival status was followed up through outpatient visits and telephone calls. Statistical analyses were performed using SPSS 25.0.
RESULTS:
A total of 39 patients with hematologic malignancies were included, among whom 35 patients had undergone allogeneic hematopoietic stem cell transplantation (allo-HSCT). The median time to EBV reactivation was 4.8 months (range: 1.7-57.1 months) after allo-HSCT. EBV was detected in B, T, and NK cells in 20 patients, in B and T cells in 11 patients, and only in B cells in 4 patients. In the 35 patients, the median EBV load in B cells was 2.19×104 copies/ml, significantly higher than that in T cells (4.00×103 copies/ml, P <0.01) and NK cells (2.85×102 copies/ml, P <0.01). Rituximab (RTX) was administered for 32 patients, resulting in EBV negativity in 32 patients with a median time of 8 days (range: 2-39 days). Post-treatment analysis of 13 patients showed EBV were all negative in B, T, and NK cells. In the four non-transplant patients, the median time to EBV reactivation was 35 days (range: 1-328 days) after diagnosis of the primary disease. EBV was detected in one or two subsets of B, T, or NK cells, but not simultaneously in all three subsets. These patients received a combination chemotherapy targeting at the primary disease, with 3 patients achieving EBV negativity, and the median time to be negative was 40 days (range: 13-75 days).
CONCLUSION
In hematologic malignancy patients after allo-HSCT, EBV reactivation commonly involves B, T, and NK cells, with a significantly higher viral load in B cells compared to T and NK cells. Rituximab is effective for EBV clearance. In non-transplant patients, EBV reactivation is restricted to one or two lymphocyte subsets, and clearance is slower, highlighting the need for prompt anti-tumor therapy.
Humans
;
Hematologic Neoplasms/virology*
;
Herpesvirus 4, Human/physiology*
;
Epstein-Barr Virus Infections
;
Hematopoietic Stem Cell Transplantation
;
Virus Activation
;
Lymphocyte Subsets/virology*
;
Flow Cytometry
;
Killer Cells, Natural/virology*
;
Male
;
Female
;
B-Lymphocytes/virology*
;
Viral Load
;
Adult
;
T-Lymphocytes/virology*
;
Middle Aged
2.Current status and prevention and control strategies of zoonotic tuberculosis
Rui-bai WANG ; Hai-can LIU ; Kang-lin WAN
Chinese Journal of Zoonoses 2025;41(4):339-345
Tuberculosis is a serious public health problem worldwide,including China.It is a typical zoonotic disease that can be transmitted between people and animals.Effective control of zoonotic tuberculosis(ZTB)is important for achieving the END-TB goal on schedule,and markedly influences the national economy.This article reviews the pathogenic characteristics,epidemic status,history,and progress in construction of a system for global and domestic ZTB prevention and control strategies.Our goal is to help achieve complete control and eradication of ZTB and tuberculosis through departmental cooperation,and joint prevention and control measures,by improving systematic understanding of ZTB among personnel formulating ZTB prevention and control policies,high-risk professionals,and clinical workers.
3.Comparison of left ventricular reverse remodeling and prognosis after transcatheter aortic valve replacement in aortic stenosis and mixed aortic valve disease
Meng SUN ; Lu-lin CHEN ; Jing-yun BAI ; Li-jie YAN ; Jing-jing LIU ; Xian-wei FAN ; Xue-jie LI ; Juan HU ; Jin-tao WU ; Hai-tao YANG
Chinese Journal of Interventional Cardiology 2025;33(2):71-78
Objective To evaluate the effects of transcatheter aortic valve replacement(TAVR)on left ventricular reverse remodeling(LVRR)and outcomes in patients with mixed aortic valve disease(MAVD)and predominant aortic stenosis(AS).Methods Patients undergoing TAVR at our center between January 2020 and December 2022 were enrolled consecutively.Propensity score matching(PSM)(1∶1 ratio)was used to reduce selection bias.Transthoracic echocardiography(TTE)was used to monitor left ventricular ejection fraction(LVEF)and other structural parameters over time.The study outcome was a composite of cardiovascular death and rehospitalization due to cardiovascular causes.Linear mixed-effects models and logistic regression were utilized for comparing echocardiographic changes across groups and identifying independent risk factors for no-LVRR,respectively.Results After PSM,126 patients were included.MAVD group exhibited larger structural parameters(left ventricular end-systolic/end-diastolic diameter and volume,left ventricular mass index)and a lower left ventricular ejection fraction(LVEF)(all P<0.05).However,more pronounced improvements in left ventricular structure and hemodynamics were observed during follow-up.Multivariate logistic regression analysis indicated that the left ventricular mass index(LVMI)was an independent predictor of left ventricular reverse remodeling(LVRR)after TAVR,whereas persistent moderate or greater mitral regurgitation(MR)and paravalvular leak(PVL)significantly reduced the incidence of LVRR.During a median follow-up period of 23 months,a total of 31 endpoint events occurred,and there was no statistically significant difference in long-term prognosis between the two groups(Log-rank P=0.330).Conclusions Compared to patients in the AS group,those in the MAVD group exhibited more severe left ventricular remodeling before TAVR.However,more significant LVRR was observed during postoperative follow-up.Additionally,the long-term prognosis was comparable between the two groups.
4.Multivariate quantitative combined with chemometrics for evaluating the quality of Sophora flavescens from different producing areas
Jiahui CHEN ; Qiong LUO ; Junli ZHAO ; Yan HAI ; Chengdong LIU ; Tuya BAI ; Jun LI ; Yuewu WANG
China Pharmacy 2025;36(19):2404-2408
OBJECTIVE To establish a content determination method for multiple components in Sophora flavescens from different origins and to evaluate its quality by combining with chemometrics. METHODS Thirteen batches (No. K1-K13) of S. flavescens from different origins were selected as test samples. A high-performance liquid chromatography-tandem triple quadrupole mass spectrometry (HPLC-MS/MS) method was established to determine the contents of 12 components, including matrine, oxymatrine, betaine, cytisine, N-methylcytisine, sophoridine, genistein, sophoricoside, sophorone, formononetin, sophorolone Ⅰ and norkurarinone in S. flavescens. Chromatographic separation was performed on a Shim-pack GIST-HP C18 column with a mobile phase consisting of methanol (A) and water containing 0.1% formic acid (B), using gradient elution at a flow rate of 0.25 mL/min, column temperature of 35 ℃, and an injection volume of 3 μL. Mass spectrometry was conducted using an electrospray ionization source with positive and negative ion scanning. Data were collected in segments using the multiple reaction monitoring mode. Technique for order preference by similarity to ideal solution (TOPSIS) and grey relational analysis (GRA)methods were employed to compare and comprehensively evaluate the 13 batches of S. flavescens from different origins. RESULTS The methodological validation for the content determination met the relevant regulatory requirements. The contents of the 12 components were 490.66-1 231.00, 11 088.10- 18 021.50, 7.91-25.38, 903.97-1 713.64, 336.08-1 485.54,1 065.33-2 075.50, 27.52-71.80, 109.36-517.83, 6 034.55-10 632.73, 21.26-145.35, 814.84-1 911.32, 1 040.87-3 446.37 μg/g), respectively. TOPSIS results showed that the top 7 samples in Euclidean distance ranking were K6, K12, K11, K3, K5, K10, K13. The GRA results showed that the top 7 samples in the relative correlation ranking were K12, K11, K10, K6, K13, K5, K3. CONCLUSIONS The established HPLC-MS/MS method is rapid, accurate, highly sensitive, stable and reliable. Combined with chemometrics methods, it can be used for the quality control and evaluation of S. flavescens. The comprehensive quality of samples K3, K5, K6( from Hebei), K10( from Sichuan), K11-K13( from Shanxi), etc. is relatively superior.
5.Preparation and physicochemical properties of nano-silver acupuncture needles.
Wenfeng HAI ; Jiaxin LIU ; Yang LIU ; Tingfang BAI ; Xiaomei HAN ; Ying YING ; Suocai TONG ; Tegexi BAIYIN ; Yingsong CHEN
Chinese Acupuncture & Moxibustion 2025;45(5):568-576
OBJECTIVE:
To explore the preparation of nano-silver acupuncture needles and evaluate the appearance, structure and properties.
METHODS:
Stainless steel acupuncture needles were pretreated by polishing with sandpaper and cleaning with ultrapure water and absolute ethanol. As the working electrodes, the needles were placed in an electrolyte solution contained silver nitrate (AgNO3), potassium nitrate (KNO3), and polyvinylpyrrolidone (PVP); and the silver nanoparticles were deposited at a constant voltage of -0.2 V for 1 200 s. The heat-treatment was conducted at 600 ℃ for 15 min in an argon atmosphere to strengthen the adhesion between the nanoparticles and the substrate. The surface appearance and structure of nano-silver acupuncture needles were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The electrical conductivity, thermal conductivity and biocompatibility of the needles were evaluated. The cytotoxicity and biocompatibility of the sample were assessed using the CCK-8 assay. According to the national standard, Acupuncture Needles (GB 2024-2016), the other physicochemical performances of nano-silver acupuncture needles were tested.
RESULTS:
①By controlling the AgNO3 concentration and the molar ratio of AgNO3 to PVP, it was found that at an AgNO3 concentration of 2 mmol/L and a molar ratio of 5∶1, silver nanoparticles with the diameter of 50-100 nm, regular appearance, and uniform distribution were obtained. At a lower concentration, the size of silver nanoparticles was smaller and unevenly distributed particles, whereas a higher concentration tended to produce a dendritic structure. ②By sandpaper polishing, acid etching pretreatment, and heat-treatment at 600 ℃ under argon for 15 min, the adhesion of silver nanoparticles on the surface of the needle body was strengthened, and the simulated pig skin puncture test showed the intact coating without shedding. ③SEM found that the silver nanoparticles were uniformly deposited, forming a nanofilm approximately 1.5 μm thick; XRD analysis showed the diffraction peaks corresponding to cubic crystal silver (111), (200), (220) and (311); and XPS detected characteristic peaks of Ag 3d3/2 and Ag 3d5/2, confirming the successful deposition and good crystallinity of the silver nanoparticles. ④Resistivity measurements indicated that the nano-silver acupuncture needles exhibited a resistivity of approximately 0.15 Ω·cm, about three times lower than that of unmodified stainless steel needles. The infrared thermography demonstrated that their thermal conductivity was superior to that of traditional acupuncture needles. In vitro CCK-8 cytotoxicity assay showed that the nano-silver acupuncture needles had no adverse effects on human skin fibroblasts and possessed good biocompatibility. ⑤ The key parameters such as needle tip performance, hardness, and the adhesion between the needle body and handle were in compliance with the requirements in Acupuncture Needles (GB 2024-2016), ensuring a quality guarantee provided for clinical applications.
CONCLUSION
The preparation of nano-silver acupuncture needles effectively overcomes the insufficient toughness of traditional silver needles and improves the electrical and thermal conductivity of stainless acupuncture needles.
Silver/chemistry*
;
Needles
;
Acupuncture Therapy/instrumentation*
;
Metal Nanoparticles/chemistry*
;
Humans
;
Electric Conductivity
;
Animals
6.Research on Detection Method for Constituent Content of Fresh Tea Leaf Based on Residual Attention Convolutional Neural Network
Hai-Liang ZHANG ; Yan ZHOU ; Wei LUO ; Bai-Shao ZHAN ; Jing ZHANG ; Xue-Mei LIU
Chinese Journal of Analytical Chemistry 2025;53(5):842-851
The rapid and non-destructive detection of constituent content of fresh tea leaves shows an important reference value for quality identification of tea.Visible near infrared(Vis-NIR)spectroscopy has been used for qualitative and quantitative analysis of chemical components in plant samples with the advantages such as simple,rapid and non-destructive detection.In this study,residual attention convolutional neural network(RACNN)was used to predict the internal constituent content of fresh tea leaves.Firstly,the reflectance spectral data of the samples in the Vis-NIR band range and the constituent contents of gallic acid(GA),gallocatechin(GC),epigallocatechin(EGC),and epigallocatechin gallate(ECG)in fresh tea leaves were collected.Based on the preprocessing of the spectral data,the contents of the four components were predicted using a partial least squares regression(PLSR)model,and the optimal preprocessing was determined.Subsequently,the characteristic bands were extracted using the random forest(RF)algorithm.Finally,the performances of PLSR,convolutional neural network(CNN)and RACNN models were compared.The results showed that for GA,the RACNN model worked best with a validation set coefficient of determination(R2)of 0.946 and a root mean square error of the prediction set(RMSEP)of 1.173;for GC,the RACNN model works best with a validation set R2 of 0.928 and RMSEP of 6.081;for EGC,the RACNN model works best with a validation set R2 of 0.891 and a RMSEP of 15.197;for ECG,the RACNN model worked best with a validation set R2 of 0.878 and a RMSEP of 7.837.The RACNN model established by Vis-NIR spectroscopy combined with chemometrics could realize the accurate detection of the contents of components in fresh tea.
7.Effect of downregulating Hsa-circ-0101216 expression on gemcitabine chemoresistance in pancreatic cancer and its mechanism
Hai-Chao LIU ; Shao-Peng LIU ; Hong-Xian YAN ; Ming-Hui BAI ; Ji-Xiang ZHANG ; Ying-Bo LI ; Chuang WANG ; Kai ZOU
Medical Journal of Chinese People's Liberation Army 2025;50(6):656-664
Objective To analyze the effect of Hsa-circ-0101216 on gemcitabine(GEM)chemotherapy resistance in pancreatic cancer and its mechanism.Methods Differentially expressed circRNAs between GEM-resistant pancreatic cancer cells and parent cells were screened using the GEO database.Pancreatic cancer GEM resistant cell lines(BxPC-3-GEM and Capan-1-GEM)were constructed by intermittent concentration gradient method.qRT-PCR was used to detect the expression of Hsa-circ-0101216 in cells.GEM resistant pancreatic cancer cell lines were taken and divided into sh-circ-0101216 group(knockdown of circ-0101216),sh-NC group(transfected with sh-NC),and blank control group(untreated).CCK-8 assay and EdU proliferation assay were used to detect the half inhibitory concentration(IC50)of GEM and proliferation ability of cells in each group.Western blotting was performed to detect the expression of multidrug resistance-related protein 1(MRP1),breast cancer resistance protein(BCRP),and human equilibrative nucleoside transporter-1(hENT-1).A subcutaneous xenograft tumor model of human pancreatic cancer in nude mice was constructed,and sh-NC+GEM group and sh-circ-0101216+GEM group(n=6)were set up.The volume and weight of xenograft tumor in nude mice were compared between the two groups.Western blotting and immunohistochemistry were used to detect the expression of MRP1,BCRP,and hENT-1 proteins in xenograft tumor tissues,and EDU proliferation assay was used to detect the proliferation ability of tumor cells.Results The GEO database screening showed that Hsa-circ-0101216 was up-regulated in GEM-resistant pancreatic cancer cell lines.Pancreatic cancer GEM-resistant cell lines were successfully constructed,and the expression levels of Hsa-circ-0101216 and the IC50 value in GEM-resistant pancreatic cancer cells BxPC-3-GEM and Capan-1-GEM were significantly higher than those in parental cells(P<0.05).In sh-circ-0101216 group,the IC50 values of GEM,cell viability,EdU positivity rate,and the expression levels of MRP1 and BCRP proteins in GEM-resistant pancreatic cancer cells BxPC-3-GEM and Capan-1-GEM were significantly lower than those in blank control group and sh-NC group,while the expression level of hENT-1 protein was significantly higher(P<0.05 or P<0.001).In sh-circ-0101216+GEM group,the weight and volume of subcutaneous xenograft tumors in nude mice,the expression levels and positive expression rates of MRP1 and BCRP proteins in tumor tissues,and the EdU positive rate were significantly lower than those in sh-NC+GEM group,while the expression level and positive expression rate of hENT-1 protein were significantly higher(P<0.05).Conclusions Hsa-circ-0101216 is highly expressed in GEM-resistant pancreatic cancer cell lines.Its knockdown can inhibit the proliferation of pancreatic cancer cells and enhance the chemosensitivity of pancreatic cancer cells to GEM.The mechanism may be related to the regulation of transmembrane transporter protein expression.
8.Review of wearable devices in field of maternal prenatal care
Na ZHAO ; Li-chun LU ; Hai-bai LIU ; Xue JIANG
Chinese Medical Equipment Journal 2025;46(10):106-113
The advantages of wearable devices were introduced when applied in the field of maternal prenatal care.The current application situation of wearable devices was reviewed for monitoring maternal cardiovascular parameters,physiological and psychosocially perceived stress,physical activity,contraction and placental oxygenation and fetal movement and heart rate monitoring.The deficiencies of wearable devices involved in the field of maternal prenatal care were analyzed,and the future development directions were envisioned.[Chinese Medical Equipment Journal,2025,46(10):106-113]
9.Annual report of National Monitoring Network for Clinical Safe Medication (2024)
Xiangrong BAI ; Qingxia ZHANG ; Yuqin WANG ; Ling JIANG ; Manling MA ; Xin HAI ; Pinfang HUANG ; Yi ZHANG ; Taotao LIU ; Suying YAN
Adverse Drug Reactions Journal 2025;27(8):449-457
In 2024, a total of 27 309 cases of medication error (ME) from 484 hospitals in 27 provincial administrative regions were collected in the National Monitoring Network for Clinical Safe Medication. Among them, 279 (1.02%) were classified as grade A, 22 081 (80.86%) as grade B, 4 268 (15.63%) as grade C, 472 (1.73%) as grade D, 96 (0.35%) as grade E, 105 (0.38%) as grade F, 6 (0.02%) as grade H, and 2 (<0.01%) as grade I; no MEs of grade G occurred. Among the 27 030 patients involved in MEs of grade B to I, 15 124 (55.95%) were male and 11 906 (44.05%) were female; their ages were from 1 day to 104 years; 3 369 (12.46%) were children (<18 years old), 12 113 (44.81%) were young and middle-aged adults (≥18 to <60 years old), and 11 548 (42.72%) were elderly (≥60 years old). The top 3 contents of ME were wrong drug class (5 347 cases, 19.13%), wrong dosage (4 913 cases, 17.58%), and wrong administration frequency (3 429 cases, 12.27%). Among the 27 030 grade B-I MEs, the main person who triggered the event were physicians (18 703 cases, 69.19%) and pharmacists (6 343 cases, 23.47%). These MEs mainly occurred in clinics (11 009 cases, 40.73%), in hospital wards (7 393 cases, 27.35%), and in pharmacies (6 219 cases, 23.27%). The main persons who discovered the MEs were pharmacists (21 021 cases, 74.14%). The top 3 factors causing ME were lack of related pharmacologic knowledge (8 716 cases, 26.49%), tiredness (5 755 cases, 17.49%), and inexperienced skills (4 505 cases, 13.69%). A total of 209 patients were involved in severe MEs (grade E-I), including 133 (63.64%) males and 76 (36.36%) females, aged from 21 months to 94 years, of which 42 (20.10%) were children, 75 (35.88%) were young and middle-aged adults, and 92 (44.02%) were elderly. The top 3 diseases diagnosed in severe MEs were drug poisoning (41 cases, 19.62%), diabetes (34 cases, 16.27%), and hypertension (14 cases, 6.70%); the main person who triggered the MEs were patients and their families (135 cases, 64.59%); the MEs occurred mainly in patients′ houses (116 cases, 55.50%). Drug poisoning was mainly related to accidental ingestion by children, and MEs in patients with diabetes and hypertension were often related to issues on patient compliance. Based on the data of MEs in 2024, it was proposed to establish a better medication safety culture and improve the ME reporting situation in China, pay attention to the risks of misusing external drugs for internal use, children′s accidental ingestion and insulin-related MEs, strengthen the prevention of MEs related to look-alike sound-alike drugs, pay attention to the post administration management and the compliance education of home care for patients with chronic diseases, so as to improve the medication safety of patients in China.
10.Review of wearable devices in field of maternal prenatal care
Na ZHAO ; Li-chun LU ; Hai-bai LIU ; Xue JIANG
Chinese Medical Equipment Journal 2025;46(10):106-113
The advantages of wearable devices were introduced when applied in the field of maternal prenatal care.The current application situation of wearable devices was reviewed for monitoring maternal cardiovascular parameters,physiological and psychosocially perceived stress,physical activity,contraction and placental oxygenation and fetal movement and heart rate monitoring.The deficiencies of wearable devices involved in the field of maternal prenatal care were analyzed,and the future development directions were envisioned.[Chinese Medical Equipment Journal,2025,46(10):106-113]

Result Analysis
Print
Save
E-mail