1.Shexiang Tongxin Dropping Pill Improves Stable Angina Patients with Phlegm-Heat and Blood-Stasis Syndrome: A Multicenter, Randomized, Double-Blind, Placebo-Controlled Trial.
Ying-Qiang ZHAO ; Yong-Fa XING ; Ke-Yong ZOU ; Wei-Dong JIANG ; Ting-Hai DU ; Bo CHEN ; Bao-Ping YANG ; Bai-Ming QU ; Li-Yue WANG ; Gui-Hong GONG ; Yan-Ling SUN ; Li-Qi WANG ; Gao-Feng ZHOU ; Yu-Gang DONG ; Min CHEN ; Xue-Juan ZHANG ; Tian-Lun YANG ; Min-Zhou ZHANG ; Ming-Jun ZHAO ; Yue DENG ; Chang-Jiang XIAO ; Lin WANG ; Bao-He WANG
Chinese journal of integrative medicine 2025;31(8):685-693
OBJECTIVE:
To evaluate the efficacy and safety of Shexiang Tongxin Dropping Pill (STDP) in treating stable angina patients with phlegm-heat and blood-stasis syndrome by exercise duration and metabolic equivalents.
METHODS:
This multicenter, randomized, double-blind, placebo-controlled clinical trial enrolled stable angina patients with phlegm-heat and blood-stasis syndrome from 22 hospitals. They were randomized 1:1 to STDP (35 mg/pill, 6 pills per day) or placebo for 56 days. The primary outcome was the exercise duration and metabolic equivalents (METs) assessed by the standard Bruce exercise treadmill test after 56 days of treatment. The secondary outcomes included the total angina symptom score, Chinese medicine (CM) symptom scores, Seattle Angina Questionnaire (SAQ) scores, changes in ST-T on electrocardiogram and adverse events (AEs).
RESULTS:
This trial enrolled 309 patients, including 155 and 154 in the STDP and placebo groups, respectively. STDP significantly prolonged exercise duration with an increase of 51.0 s, compared to a decrease of 12.0 s with placebo (change rate: -11.1% vs. 3.2%, P<0.01). The increase in METs was significantly greater in the STDP group than in the placebo group (change: -0.4 vs. 0.0, change rate: -5.0% vs. 0.0%, P<0.01). The improvement of total angina symptom scores (25.0% vs. 0.0%), CM symptom scores (38.7% vs. 11.8%), reduction of nitroglycerin consumption (100.0% vs. 11.3%), and all domains of SAQ, were significantly greater with STDP than placebo (all P<0.01). The changes in Q-T intervals at 28 and 56 days from baseline were similar between the two groups (both P>0.05). Twenty-five participants (16.3%) with STDP and 16 (10.5%) with placebo experienced AEs (P=0.131), with no serious AEs observed.
CONCLUSION
STDP could improve exercise tolerance in patients with stable angina and phlegm-heat and blood stasis syndrome, with a favorable safety profile. (Registration No. ChiCTR-IPR-15006020).
Humans
;
Double-Blind Method
;
Drugs, Chinese Herbal/adverse effects*
;
Male
;
Female
;
Middle Aged
;
Angina, Stable/physiopathology*
;
Aged
;
Syndrome
;
Treatment Outcome
;
Placebos
;
Tablets
2.Value of 6-Minute Walking Test in Predicting Acute Mountain Sickness.
Yu-Fan JIANG ; Qiang MA ; Hai-Wei CHEN ; Bao-Shi HAN ; Bin FENG ; Yun-Dai CHEN
Acta Academiae Medicinae Sinicae 2025;47(4):535-541
Objective To evaluate the value of pre-ascent 6-minute walking test performed at a high altitude in predicting the incidence of acute mountain sickness(AMS)induced by rapid ascent to a very high altitude.Methods After baseline information was collected,participants completed the 6-minute walking test at a high altitude of 2 900 m.Then,they rapidly ascended to a very high altitude of 5 000 m.The Lake Louise score was recorded to assess AMS.Results The AMS group showed a shorter pre-ascent 6-minute walking distance(6MWD)at the high altitude than the non-AMS group[480.00(450.00,521.75)m vs.546.00(516.50,568.50)m,P=0.006].No difference was observed regarding the pre-ascent heart rate or peripheral oxygen saturation(both P>0.05).The pre-ascent 6MWD at the high altitude was negatively correlated with the Lake Louise score assessed after rapid ascent to the very high altitude(r=-0.497,P=0.012).Logistic regression analysis confirmed that the pre-ascent 6MWD at the high altitude was associated with the risk of AMS induced by rapid ascent to the very high altitude(OR=0.971,95% CI=0.947-0.996,P=0.022).The results indicated that the pre-ascent 6MWD demonstrated ideal prediction performance(area under receiver operating characteristic curve=0.846,P=0.006).Conclusion The pre-ascent 6MWD recorded at the high altitude is a convenient and reliable predictor of the AMS induced by rapid ascent to the very high altitude.
Humans
;
Altitude Sickness/diagnosis*
;
Male
;
Adult
;
Female
;
Young Adult
;
Middle Aged
;
Acute Disease
;
Walk Test
;
Walking
;
Altitude
;
Exercise Test
3.In-Situ Controlled Growth of NiCr Layered Double Hydroxide Nanosheets on Nichrome Alloy Fibers for Solid Phase Microextraction of Chlorophenols
Hai-Xia LIU ; Hong-Hong RAO ; Fang LIU ; Yan-Ping ZHENG ; Yong-Qiang JIANG
Chinese Journal of Analytical Chemistry 2025;53(3):481-491,后插1-后插4,封3
Nichrome(NiCr)wire with strong mechanical properties,excellent flexibility,good corrosion resistance and high thermal stability was selected as a promising fiber substrate to replace the fragile fused-silica counterpart.The NiCr layered double hydroxide nanosheets(NiCr LDHs NSs)were in-situ grown on the NiCr fiber substrate.Then,the extraction performance of the NiCr@NiCr LDHs NSs fiber was evaluated using four kinds of chlorophenol(CPs)as model compounds combined with high performance liquid chromatography-ultraviolet detection(HPLC-UV).The results showed that the assembled fibers exhibited superior extraction selectivity and enhanced extraction efficiency for CPs in comparison to commercial PA,PDMS,and PDMS/DVB fibers.Under the optimized experimental conditions,the established method showed good linearity in the range of 0.2-200 μg/L,with coefficient of determination(R2)>0.9989.The limits of detection(LODs)and limits of quantification(LOQs)were 0.050-0.157 μg/L and 0.165-0.502 μg/L,respectively.Relative standard deviations(RSDs)for intra-day and inter-day analyses ranged from 2.85%to 4.05%and from 3.16%to 4.96%,respectively.The developed method with the constructed fiber was applied to preconcentration and detection of different types of CPs in real water samples,showing satisfactory recoveries ranging from 80.0%to 106.9%,with RSDs of 3.12%-7.81%.Moreover,the NiCr@NiCr LDHs NSs fiber could maintain good extraction performance even after 240 extraction-desorption cycles.
4.Relationship between postoperative revascularization efficacy and levels of VEGF,IGF-1 and TGF-β1 in joint synovial fluid in children with Perthes Disease
Tian LIANG ; Qi ZHANG ; Li-Hai MA ; Ai-Qiang LANG ; Chuan-Jiang YAO ; Lan-Ping XU
Medical Journal of Chinese People's Liberation Army 2025;50(10):1263-1269
Objective To explore the relationship between levels of vascular endothelial growth factor(VEGF),insulin-like growth factor 1(IGF-1),and transforming growth factor-β1(TGF-β1)in the synovial fluid of children with avascular necrosis of the femoral head(also known as Perthes disease)and the efficacy of postoperative revascularization,aiming to provide a basis for subsequent diagnosis and treatment.Methods A retrospective study was conducted on 262 children with Perthes disease admitted to the Affiliated Hospital of Gansu University of Chinese Medicine from January 2023 to June 2024.Based on postoperative revascularization efficacy,patients were divided into good revascularization group(n=228)and poor revascularization group(n=34).For poor revascularization group,a 1:2 matched case-control design was used to select 68 age-matched children with hip synovitis who underwent hip joint fluid puncture as control group.Additionally,82 children with Perthes disease treated at the hospital from June 2024 to January 2025 were enrolled as a validation cohort for nomogram model verification.The expression levels of VEGF,IGF-1 and TGF-β1 in the synovial fluid of three groups were compared.Confounding biases were controlled through univariate and stratified analyses.Binary logistic regression analysis was used to identify independent factors affecting the revascularization effect.R software was utilized to draw and verify the nomogram model for predicting the postoperative revascularization effect.Results The levels of VEGF,IGF-1 and TGF-β1 in the synovial fluid of children in poor revascularization group were all higher than those in control group and good revascularization group(P<0.05).After three types of reconstructive surgeries,the levels of VEGF,IGF-1 and TGF-β1 in the synovial fluid of children with poor revascularization were all higher than those in children with good revascularization(P<0.05);however,there was no statistically significant difference in the above indicators among different surgical types(P>0.05).Binary logistic regression analysis showed that the levels of VEGF,IGF-1,and TGF-β1 in the synovial fluid were independent risk factors for poor postoperative revascularization in children with Perthes disease.The area under the ROC curve of the nomogram model established accordingly for predicting poor postoperative revascularization in children with Perthes disease was 0.875(95%CI 0.805-0.945),with a sensitivity of 0.874 and a specificity of 0.851.Moreover,the calibration curve and decision curve analysis(DCA)indicated that the model had good clinical applicability.Conclusions The increased levels of VEGF,IGF-1 and TGF-β1 in synovial fluid are associated with poor postoperative revascularization in children with Perthes disease.These three factors are expected to become prognostic indicators for children with Perthes disease.
5.Study on the material basis and mechanism of anti-insomnia mechanism of Ning Shen Essential Oil based on 1H NMR metabolomics and network pharmacology
Qing CHAI ; Hong-bin ZHANG ; Li-dong WU ; Jing-yi WANG ; Hai-chao LI ; Yu-hong LIU ; Hong-yan LIU ; Hai-qiang JIANG ; Zhen-hua TIAN
Acta Pharmaceutica Sinica 2024;59(8):2313-2325
This paper applied gas chromatography-mass spectrometry (GC-MS), network pharmacology and nuclear magnetic resonance hydrogen spectroscopy (1H NMR) metabolomics techniques to study the material basis and mechanism of action of Ning Shen Essential Oil in anti-insomnia. The main volatile components of Ning Shen Essential Oil were analyzed by gas chromatography-mass spectrometry (GC-MS), and the insomnia-related targets were predicted using the Traditional Chinese Medicine Systematic Pharmacology Database and Analytical Platform (TCMSP) and the databases of GeneCards, OMIM and Drugbank. The insomnia model of rats was replicated by intraperitoneal injection of 4-chloro-
6.Effect of different blood pressure stratification on renal function in diabetic population
Yong-Gang CHEN ; Shou-Ling WU ; Jin-Feng ZHANG ; Shuo-Hua CHEN ; Li-Wen WANG ; Kai YANG ; Hai-Liang XIONG ; Ming GAO ; Chun-Yu JIANG ; Ye-Qiang LIU ; Yan-Min ZHANG
Medical Journal of Chinese People's Liberation Army 2024;49(6):663-669
Objective To investigate the effect of varying blood pressure stratification on renal function in the diabetic population.Methods A prospective cohort study was conducted,enrolling 9 489 diabetic patients from a total of 101 510 Kailuan Group employees who underwent health examinations between July 2006 and October 2007.The follow-up period was(8.6±4.0)years.Participants were categorized into four groups based on their baseline blood pressure levels:normal blood pressure(systolic blood pressure<120 mmHg and diastolic blood pressure<80 mmHg),elevated blood pressure(systolic blood pressure 120-130 mmHg and diastolic blood pressure<80 mmHg),stage 1 hypertension(systolic blood pressure 130-140 mmHg and/or diastolic blood pressure 80-90 mmHg),and stage 2 hypertension(systolic blood pressure≥140 mmHg and/or diastolic blood pressure≥90 mmHg).The incidence density of chronic kidney disease(CKD)was compared among these groups.A multivariate Cox proportional hazards regression model was employed to assess the effects of different blood pressure levels on renal function in diabetic patients,with the stability of the results confirmed using a multivariate time-dependent Cox proportional hazards model.Sensitivity analysis was conducted after excluding cases of cardiovascular disease(CVD)during follow-up,and cases using antihypertensive and antidiabetic medications at baseline.Results(1)At baseline,stage 1 hypertension patients demonstrated statistically significant higher differences with age and body mass index(BMI)compared to normal blood pressure group(P<0.05).(2)By the end of the follow-up,2 294 cases of CKD were identified,including 1 117 cases of estimated glomerular filtration rate(eGFR)decline and 1 575 cases of urinary protein.The incidences density of CKD,eGFR decline and urinary protein for stage 1 hypertension group were 39.4,16.3 and 25.5 per thousand person-years,respectively,all of which were statistically significant different from normal blood pressure group(log-rank test,P<0.01).(3)Multivariate Cox regression analysis revealed that,compared to the normal blood pressure group,stage 1 hypertension was associated with a 29%increased risk of CKD(HR=1.29,95%CI 1.09-1.52)and a 40%increased risk of eGFR decline(HR=1.40,95%CI 1.08-1.80)in diabetic individuals.Conclusion Stage 1 hypertension significantly increases the risk of CKD and eGFR decline in diabetic individuals,with a particularly notable effect on the risk of eGFR decline.
7.Orthopaedic robot assisted closed reduction and cannulated screw internal fixation for the treatment of femoral neck fractures
Shou-Hai JIANG ; Chuan-Kai ZHANG ; Fang-Teng JIA ; Qiang CHEN ; Meng XU ; Pei-Lin YANG ; Yu-Shuai ZHANG
China Journal of Orthopaedics and Traumatology 2024;37(2):119-123
Objective To investigate the preliminary clinical effect of closed reduction and cannulated nail internal fixa-tion for femoral neck fracture assisted by robot navigation and positioning system.Methods From July 2019 to January 2020,16 cases of femoral neck fracture(navigation group)were treated with closed reduction and internal fixation guided by robot system,including 7 males and 9 females,aged 25 to 72 years old with an average of(53.61±5.45)years old;Garden classification of fracture:3 cases of type Ⅰ,3 cases of type Ⅱ,8 cases of type Ⅲ,2 cases of type Ⅳ.Non navigation group(control group):20 cases of femoral neck fracture were treated with closed reduction and hollow nail internal fixation,8 males and 12 females,aged 46 to 70 years old with an average of(55.23±4.64)years old;Garden type Ⅰ in 2 cases,type Ⅱ in 4 cases,type Ⅲ in 11 cases,type Ⅳ in 3 cases.The operation time,fluoroscopy times,guide needle drilling times,screw adjustment times,intraoperative bleeding volume and other indicators of two groups were evaluated.Results Both groups were followed up for 12 to 18 months with an average of(15.6±2.8)months.The fractures of both groups were healed without delayed union and nonunion.There was no significant difference in healing time between two groups(P=0.782).There was no significant differ-ence in Harris scores between two groups at the last follow-up(P=0.813).There was no significant difference in operation time between two groups(P>0.05).There were significant differences between two groups in fluoroscopy times,guide needle drilling times,hollow screw replacement times,and intraoperative bleeding volume(P<0.05).Conclusion Closed reduction and hollow screw internal fixation assisted by robot navigation system for femoral neck fracture has the advantages of minimally invasive operation,precise screw placement,and reduction of X-ray radiation damage during operation.
9.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail