1.A Nomogram for Predicting Metachronous Gastric Cancer After Endoscopic Submucosal Dissection of Early Gastric Cancer Following Successful Helicobacter pylori Eradication
Shangtao MAO ; Miao LIU ; Tao ZHAO ; Qiong YAN ; Ying XIANG ; Hai WU ; Wenjun LI ; Hongji TAO ; Duanming ZHUANG ; Lei WANG ; Guifang XU
Journal of Gastric Cancer 2026;26(2):279-294
Purpose:
Due to the preservation of the entire stomach after endoscopic resection, the occurrence of metachronous gastric cancer (MGC) remains a possibility. In this study, we investigated the incidence and risk factors for MGC in patients with early gastric cancer who underwent endoscopic submucosal dissection (ESD) and successfully eradicatedHelicobacter pylori.
Materials and Methods:
A retrospective analysis was conducted of 1,191 patients who underwent ESD and successfully eradicated H. pylori at the Affiliated Drum Tower Hospital of Nanjing University. Endoscopic surveillance was performed at 3, 6, and 12 months post-resection, and annually thereafter. MGC was defined as the development of a new cancer at a site other than the primary gastric cancer site, at least 1 year after the initial endoscopic resection.
Results:
A total of 77 patients were diagnosed with MGC during a median follow-up of 41.5 months. Kaplan-Meier analysis showed a 5-year cumulative incidence of MGC of 9.4% after successful H. pylori eradication. Multivariate analysis of the training set using Cox proportional hazards models identified male sex, severe atrophic gastritis, multiple gastric cancers before H. pylori eradication, and smoking history as independent risk factors for MGC.The nomogram exhibited favorable discrimination, with area under the curves of 0.767 and 0.822 in the training set and 0.724 and 0.745 in the testing set at 3 and 5 years, respectively.
Conclusions
Patients with gastric cancer who undergo endoscopic resection, even after successful H. pylori eradication, should undergo annual and continuous endoscopic surveillance for MGC.
2.Research progress on traditional Chinese medicine in treating cardiotoxicity induced by anticancer drugs
Linling SU ; Xianxia YUAN ; Wenyu JIANG ; Ling MO ; Jiaxue WU ; Min WANG ; Dongling LIU ; Yang HAI
Journal of China Pharmaceutical University 2026;57(3):393-400
Cardiotoxicity induced by antineoplastic agents is an important factor affecting the prognosis of cancer patients. This article systematically summarizes the clinical manifestations of cardiotoxicity caused by chemotherapeutic drugs, molecular targeted cancer therapies, and immunotherapeutic drugs, and identifies the core injury mechanisms, including cardiomyocyte apoptosis, oxidative stress, and mitochondrial dysfunction. In Traditional Chinese Medicine (TCM) theory, anticancer drug-induced cardiotoxicity falls under the category of “heat toxins” characterized by dual deficiency of qi and blood, upward flaming of heart heat, stagnation of the heart vessels, and meridian obstruction induced by phlegm-dampness. Therefore, by reviewing the preventive and therapeutic effects and the underlying mechanisms of tonic medicines, interior heat-clearing medicines, blood-circulating and stasis-resolving medicines, phlegm-transforming, cough-suppressing and panting-relieving medicines, and interior-warming medicines, this paper concludes that TCM prevention and treatment of this condition adheres to the formulation principle of “reinforcing healthy qi, removing toxins, and resolving blood stasis”. Its mechanisms of action—including antioxidation effects, regulation of autophagic balance, antagonism of inflammatory responses, and improvement of microcirculation—are highly consistent with modern medical treatment strategies (e.g., dexrazoxane for inhibiting iron-dependent oxidative stress, statins for anti-inflammatory effects). This study provides theoretical support and practical guidance for the collaborative and precise prevention and treatment of anticancer drug-induced cardiotoxicity through the integration of traditional Chinese and Western medicine.
3.Study on the correlation between the concentration of maternal serum biomarkers and the risk of fetal presenting with copy number variation
Mengting ZHANG ; Dandan LI ; Yue GAO ; Dong WU ; Hai XIAO ; Liangjie GUO ; Hongdan WANG
Acta Universitatis Medicinalis Anhui 2026;61(8):1458-1463
ObjectiveTo explore the association between the concentration of maternal serum biomarkers, including free beta-human chorionic gonadotropin (fβ-hCG), alpha fetoprotein (AFP), unconjugated estriol (uE3), and inhibin A (INH A) during the second trimester pregnancy and the risk of fetal presenting with copy number variation (CNV). MethodsA retrospective analysis was conducted on the diagnostic results of pregnant women who were identified as high risk in the second trimester quadruple serological screening. These pregnant women underwent the interventional prenatal diagnosis and performed amniotic fluid karyotype analysis and comparative genomic hybridization array (aCGH) or CNV sequencing (CNV-seq) simultaneously.The detection rates of different diagnostic methods were calculated. The concentration of serum biomarkers, fβ-hCG, AFP, uE3, and INH A were divided into three levels: abnormally low, normal, and abnormally high. The prevalence of these serum biomarkers concentration in pregnant women with aberrant aCGH/CNV-seq results compared to normal controls was statistically calculated. ResultsAmong the 1 516 cases with high-risk quadruple serological screening in the second trimester, 59 chromosomal abnormalities were revealed by karyotype analysis, while 87 abnormalities were detected by aCGH/CNV-seq, indicating a significant statistical difference in detection rate. In comparison to the result of karyotype analysis, aCGH/CNV-seq identified an additional 46 cases of fetal CNV abnormalities, whereas it failed to detect 18 cases of chromosomal structural abnormalities. Among the 1 457 cases with normal karyotype results, the most frequent abnormality was observed in the concentration of fβ-hCG, followed by abnormalities in INH A and uE3 concentrations, yet the least common abnormality was noted in AFP concentration. When the maternal serum uE3 concentration was less than 0.5 multiples of median (MoM), there was a significant difference in the risk of fetal CNV compared to the CNV results corresponding to normal concentration of uE3. No significant differences were found in the levels of fβ-hCG, AFP, and INH A between the two groups. ConclusionLow serum uE3 concentration (<0.5 MoM) is associated with an increased risk of fetal presenting with aberrant CNV.
4.Expert Consensus on Clinical Application of Qinbaohong Zhike Oral Liquid in Treatment of Acute Bronchitis and Acute Attack of Chronic Bronchitis
Jian LIU ; Hongchun ZHANG ; Chengxiang WANG ; Hongsheng CUI ; Xia CUI ; Shunan ZHANG ; Daowen YANG ; Cuiling FENG ; Yubo GUO ; Zengtao SUN ; Huiyong ZHANG ; Guangxi LI ; Qing MIAO ; Sumei WANG ; Liqing SHI ; Hongjun YANG ; Ting LIU ; Fangbo ZHANG ; Sheng CHEN ; Wei CHEN ; Hai WANG ; Lin LIN ; Nini QU ; Lei WU ; Dengshan WU ; Yafeng LIU ; Wenyan ZHANG ; Yueying ZHANG ; Yongfen FAN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(4):182-188
The Expert Consensus on Clinical Application of Qinbaohong Zhike Oral Liquid in Treatment of Acute Bronchitis and Acute Attack of Chronic Bronchitis (GS/CACM 337-2023) was released by the China Association of Chinese Medicine on December 13th, 2023. This expert consensus was developed by experts in methodology, pharmacy, and Chinese medicine in strict accordance with the development requirements of the China Association of Chinese Medicine (CACM) and based on the latest medical evidence and the clinical medication experience of well-known experts in the fields of respiratory medicine (pulmonary diseases) and pediatrics. This expert consensus defines the application of Qinbaohong Zhike oral liquid in the treatment of cough and excessive sputum caused by phlegm-heat obstructing lung, acute bronchitis, and acute attack of chronic bronchitis from the aspects of applicable populations, efficacy evaluation, usage, dosage, drug combination, and safety. It is expected to guide the rational drug use in medical and health institutions, give full play to the unique value of Qinbaohong Zhike oral liquid, and vigorously promote the inheritance and innovation of Chinese patent medicines.
5.Severity Assessment Parameters and Diagnostic Technologies of Obstructive Sleep Apnea
Zhuo-Zhi FU ; Ya-Cen WU ; Mei-Xi LI ; Ping-Ping YIN ; Hai-Jun LIN ; Fu ZHANG ; Yu-Xiang YANG
Progress in Biochemistry and Biophysics 2025;52(1):147-161
Obstructive sleep apnea (OSA) is an increasingly widespread sleep-breathing disordered disease, and is an independent risk factor for many high-risk chronic diseases such as hypertension, coronary heart disease, stroke, arrhythmias and diabetes, which is potentially fatal. The key to the prevention and treatment of OSA is early diagnosis and treatment, so the assessment and diagnostic technologies of OSA have become a research hotspot. This paper reviews the research progresses of severity assessment parameters and diagnostic technologies of OSA, and discusses their future development trends. In terms of severity assessment parameters of OSA, apnea hypopnea index (AHI), as the gold standard, together with the percentage of duration of apnea hypopnea (AH%), lowest oxygen saturation (LSpO2), heart rate variability (HRV), oxygen desaturation index (ODI) and the emerging biomarkers, constitute a multi-dimensional evaluation system. Specifically, the AHI, which measures the frequency of sleep respiratory events per hour, does not fully reflect the patients’ overall sleep quality or the extent of their daytime functional impairments. To address this limitation, the AH%, which measures the proportion of the entire sleep cycle affected by apneas and hypopneas, deepens our understanding of the impact on sleep quality. The LSpO2 plays a critical role in highlighting the potential severe hypoxic episodes during sleep, while the HRV offers a different perspective by analyzing the fluctuations in heart rate thereby revealing the activity of the autonomic nervous system. The ODI provides a direct and objective measure of patients’ nocturnal oxygenation stability by calculating the number of desaturation events per hour, and the biomarkers offers novel insights into the diagnosis and management of OSA, and fosters the development of more precise and tailored OSA therapeutic strategies. In terms of diagnostic techniques of OSA, the standardized questionnaire and Epworth sleepiness scale (ESS) is a simple and effective method for preliminary screening of OSA, and the polysomnography (PSG) which is based on recording multiple physiological signals stands for gold standard, but it has limitations of complex operations, high costs and inconvenience. As a convenient alternative, the home sleep apnea testing (HSAT) allows patients to monitor their sleep with simplified equipment in the comfort of their own homes, and the cardiopulmonary coupling (CPC) offers a minimal version that simply analyzes the electrocardiogram (ECG) signals. As an emerging diagnostic technology of OSA, machine learning (ML) and artificial intelligence (AI) adeptly pinpoint respiratory incidents and expose delicate physiological changes, thus casting new light on the diagnostic approach to OSA. In addition, imaging examination utilizes detailed visual representations of the airway’s structure and assists in recognizing structural abnormalities that may result in obstructed airways, while sound monitoring technology records and analyzes snoring and breathing sounds to detect the condition subtly, and thus further expands our medical diagnostic toolkit. As for the future development directions, it can be predicted that interdisciplinary integrated researches, the construction of personalized diagnosis and treatment models, and the popularization of high-tech in clinical applications will become the development trends in the field of OSA evaluation and diagnosis.
6.Intestinal blast injuries after different intensity waveshock in rats exposure to extremely cold environment:a comparative study
Yongchao YUE ; Libin ZHANG ; Wenqi ZHOU ; Junren WANG ; Pengfei WU ; Guangyan WU ; Hai MA
Journal of Army Medical University 2025;47(17):2071-2078
Objective To compare the intestinal injury induced by different intensities of waveshock in rats exposed to extremely cold environment and to preliminarily explore the characteristics of the injury.Methods Sixty healthy male SD rats(2 months old,weighing 200~250 g)were randomly divided into 6 groups(n=10):blank control group,low-temperature control group,5.0 MPa shock control group,and low-temperature+4.0,4.5 and 5.0 MPa shock groups.The rats in the experimental groups were pre-treated in a-10℃low-temperature environment for 30 min and then subjected to intestinal injury by using BST-I biological shock tube with different driving pressures.At 3,8,and 24 h after injury,the serum levels of IL-6,TNF-α,intestinal fatty acid binding protein(I-FABP),and diamine oxidase(DAO)were detected,and the survival of rats within 24 h was recorded.At 24 h after injury,the rats were anesthetized and dissected,the characteristics of intestinal injury were observed,and pathological examination was performed.The differences of intestinal injury were compared among the 6 groups to explore the characteristics of intestinal injuries after different intensities of shockwave in rats after exposure to extremely cold environment.Results Compared with the blank control group,the other 5 groups exhibited different severities of intestinal injury,and the rats in the low-temperature+different shock groups were more prone to intestinal edema and trauma.The mortality rate was significantly increased in the low-temperature+5.0 MPa shock group(P<0.05).Pathological and serological studies found that dual effects of very cold environment and blast injury resulted in intestinal mucosal hemorrhage,edema,and disintegration of lamina propria in the experimental rats.The indicators of intestinal mucosal injury and intestinal inflammatory factors were also significantly increased when compared with the blank control group,and significant differences were among the groups with increment of shock intensity(P<0.05).Conclusion Exposure to very cold environment combined with abdominal blast injury increases mortality rate in rats,manifested by elevated serological indicators and intestinal inflammatory factors,as well as varying severities of intestinal wall edema and submucosal bleeding.Furthermore,the severity of the injury is positively related to the impact intensity,with worsened as the impact intensity increasing.
7.Fluorescence Method for Determination of Metolazone and Valsartan in Human Serum and Urine:A Comparison from Zero-order to Second-order Calibration Method
Zi-Wei DING ; Hai-Long WU ; Xiao-Zhi WANG ; Tong WANG ; Hao-Ran LIU
Chinese Journal of Analytical Chemistry 2025;53(2):224-234
A second-order calibration method combined with excitation-emission matrix(EEM)fluorescence spectroscopy was presented for simultaneous quantitative analysis of two anti-hypertensive drugs,metolazone(MET)and valsartan(VAL),in human serum and urine,and the quantitative results were compared with the results obtained by zero-and first-order calibration methods.The results indicated that the methods based on zero-and first-order calibration were inadequate for accurately quantifying the components of interest in cases where severe spectral overlap and unknown interferences coexisted.However,it was possible to obtain satisfactory results with the second-order calibration method based on alternating normalization-weighted error(ANWE)algorithm because of its strong"mathematical separation",even when the fluorescence spectra of the target analytes and unknown interferents considerably overlapped.Correlation coefficients for both analytes were greater than 0.99,with mean recoveries of 104.9%±5.7%and 107.8%±9.2%for MET and VAL in human serum,and 103.7%±8.9%and 94.7%±3.8%in human urine,respectively.In addition,the sensitivity,selectivity,limit of detection,limit of quantification,repeatability,and reproducibility of the proposed second-order calibration method were thoroughly examined.All results indicated that the established method was capable of achieving simultaneous and accurate quantification of MET and VAL in human body fluids,which was expected to be applied to analysis of both drugs in clinical settings.
8.Gas Chromatography-Infrared Spectroscopy Assisted Gas Chromatography-Mass Spectrometry for Identification of Alkyl Phosphonate Isomers
Mei-Qi ZHAO ; Yu-Long LIU ; Qin LIU ; Wei YOU ; Jian-Feng WU ; Hai-Xia WU ; Jia CHEN ; Jian-Wei XIE
Chinese Journal of Analytical Chemistry 2025;53(2):269-277
Organophosphorus nerve agents are the most threatening chemical warfare agents and terrorist agents.The number of nerve agents and their related chemicals involved in the verification of Chemical Weapon Convention(CWC)exceeds ten million,with the majority being isomers.Accurate structural identification of these chemicals has always been one of the challenges in CWC related verification analysis.In this work,a total of 17 kinds of alkyl phosphonate isomers and structural analogs from 5 groups were designed and synthesized,and then analyzed by gas chromatography-mass spectrometry(GC-MS)and gas chromatography-infrared spectroscopy(GC-FTIR).The spectra of isomers or structural analogs obtained from two techniques as well as the structural information provided therein were compared and analyzed.The results showed that for isomers or structural analogs with similar MS spectra,FTIR spectra could provided more structural fingerprint information of compounds and had advantages in confirming structures.Combined with the excellent separation ability of GC,GC-FTIR can be used to assist GC-MS in the structural confirmation of alkyl phosphates,achieving rapid and accurate identification of isomers or structural analogues.
9.Development of A Low Field Ion Extraction System for Time-of-Flight Secondary Ion Mass Spectrometry
De-Ze WANG ; Chen-Xin WU ; Yi CHEN ; Fu-Xin DU ; Lei HUA ; Hai-Yang LI ; Jian-Hua WANG ; Ping CHEN
Chinese Journal of Analytical Chemistry 2025;53(7):1072-1081
Time-of-flight secondary ion mass spectrometer(TOF-SIMS)is a highly sensitive surface analysis instrument with high spatial resolution.Traditional TOF-SIMS instruments for sample targets use high field extraction methods.Although the ion collection efficiency is high,it is prone to issues such as low-energy ion beam defocusing,sample morphology sensitivity,and organic molecule ion dissociation.This study aimed to develope an efficient low-field ion extraction system suitable for TOF-SIMS with a continuous beam source.The SIMION simulation software was used to construct a model of the secondary ion optical extraction system.The key factors affecting the extraction efficiency were studied,and the structural parameters of the extraction cone were optimized.Using an indium target as the sample,an experimental test of the performance of the ion extraction system was carried out on the TOF-SIMS instrument.The influences of the voltages of the ion extraction cone and the single lens on the ion extraction efficiency were consistent with the simulation results.By adopting the technology of deflection and coaxial dynamic compensation,the imaging field of view of the ion extraction system was increased to 500 μm×500 μm.The energy window of the ion extraction system reached 10 eV,and the large imaging depth of field of 400 μm was achieved.In the test of a 5 mg/L cholesterol thin film sample,the signal-to-noise ratio of the characteristic peak[M-OH]+reached 4453.The results showed that this low-field secondary ion extraction system effectively improved the performance of the continuous beam TOF-SIMS instrument.
10.Determination of 71 Kinds of Per-and Polyfluoroalkyl Substances in Eckloniae Thallus by QuEChERS-Liquid Chromatography-Tandem Mass Spectrometry
Dan-Rui TANG ; Jing SUN ; Ling CAO ; Dan-Yi JIANG ; Hai-Wei SHI ; Lu-Lu WU
Chinese Journal of Analytical Chemistry 2025;53(7):1177-1185,中插9-中插25
A QuEChERS cleanup-ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)method was established for simultaneous determination of traditional and emerging 71 kinds of per-and polyfluoroalkyl substances(PFAS)in Chinese herbal medicine Eckloniae Thallus.The extraction solvent employed here was 0.2%formic acid-acetonitrile with sodium chloride-anhydrous sodium sulfate(3:1,m/m)as salting-out agent,and the purification was carried out using graphitized carbon black and octadecyl-bonded silica as adsorbents.The sample separation was carried out on a Horizon C18 chromatographic column(150 mm×2.1 mm,1.6 μm)by gradient elution with 2.5 mmol/L ammonium acetate aqueous solution(containing 2.5 mmol/L acetic acid)and acetonitrile as the mobile phases.The flow rate was set at 0.4 mL/min,with an injection volume of 5 μL.The chromatographic separation of each target compound and internal standard substance could be achieved within 15 min.An electrospray ion source was utilized for simultaneous scanning of positive and negative ions under the scheduled multiple reaction monitoring(sMRM)mode,and the internal standard method was used for quantitative analysis.The results of method validations showed that the 71 kinds of PFAS had good linearity,with a correlation coefficient(r)greater than 0.997,spiked recoveries of 76.2%?122.0%and relative standard deviations(RSDs)of 5.5%?14.8%.The limits of detection were in the range of 0.3-60 ng/kg and the limits of quantification were in the range of 0.8-199 ng/kg.The developed method was used for detection of PFAS in 14 batches of Eckloniae Thallus samples,and a total of 19 kinds of PFAS were detected.The findings indicated that PFAS residues were commonly present in Eckloniae Thallus,with perfluorocarboxylic acids(PFCAs)exhibiting the highest concentrations.The method was simple,robust and efficient in preparation,sensitive in detection with high throughput,and suitable for monitoring residual PFAS compounds,including both ionic and neutral in food-medicine homology samples such as Eckloniae Thallus.

Result Analysis
Print
Save
E-mail